Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.5 L+₹3.2 L (10.5%)Rejected-Finance HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹34.5 L+₹4.2 L (13.7%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹37.0 L+₹6.7 L (22.0%)Rejected-Finance RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹38.4 L
EMD Value
₹76,700
Closing Date
22 Nov 2021, 6:00 pmClosed
GE NARANGI
GE Narangi C/O 99 APO
SPECIAL REPAIR TO BLDG NO 115 AND 116 AT TRANSIT FACILITY PROVN OF STORE ROOM AND PROVN OF WATER COOLER UNDER GE NARANGI
2021_MES_483878_1
8701/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE NARANGI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NARANGI
₹76,700
Yes
14 Dec 2021
25 Oct 2021
25 Nov 2021
25 Oct 2021
22 Nov 2021
8 Nov 2021
Amount
M&L surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.complete all as specified and directed.
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface complete all as specified & as directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified & as directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 ltrs of emulsion per square meter of vertical surface (Area of the sub structure in contract with backfill to be measured) complete all as specified and as directed.
M&L for treating the soil along the external perimeter of building at the rate of 2.25 litres of emulsion per square metre of perimeter of wall complete all as specified & as directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & as directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed to true surface complete all as specified and directed.
M&L hardcore of gauge n exc. 63mm with broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L hardcore of gauge exceeding 63mm not exc. 100mm with broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.complete all as specified and directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M & L for 20 mm thick cement concrete 1:2:4, type B-0 as in damp proof course (DPC) to horizontal or vertical surfaces in cement mortar 1:2 with WPC as per manufacturer's instruction including necessary form work complete all as specified and as directed.
M&L for Precast reinforced cement concrete type B-0 1:2:4 ( 12.5mm graded aggregate) in door and window frames, any size , single or double rebated, including arrangemenrt for fixing of hinges complete all as specified as directed.
M&L for RCC 1:2:4 type B1(20mm graded stone aggregate) nominal mix as in Slabs supported on walls beams and columns in floors,roofs,landings, balconies,canopies,deck slabs and in shelves and the like etc complete all as specified as directed.
M/L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works, not exceeding 200mm thick ( Horizontal or sloping) complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.
M & L for mild steel chimney bars ( straight or camber), bearing bars, tounges or water bars for window frames, window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc and similar articles conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for mild steel TMT bars 6 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of brick /stone massonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
All as per item No. 23 above but except bricks. (Serviceable bricks obtained from demolition shall be reused).
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4, type B0 (using 12.5mm graded stone aggregate) as in roof surfaces , chajjas finished the surface fair and even including all necessary form work complete all as specified and as directed.
M & L for PCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in benching , coping, haunching between roof and wall or parapet wall, between chajjas and wall etc. finished fair and even including neccessary form work complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish not exceeding 100 mtr distance from starting point. (ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 with mixing of WPC and surface finished fare and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm.
M&L for 75mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 75mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) complete all as specified and directed.
M&L for 100mm thick PCC type B-2, 1:2:4 (40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for providing 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection. Plinth protection shall be laid in alternate bays n exc 2 sqm, 10 mm thick joints shall be provided, joint shall be filled with bitumen mastic, bitumen mastic shall comprises of 1 part of hot bitumen 85/25 and 3 parts of sand all by weight finished cement concrete surface even and fair without using extra cement complete all as specified and as directed.
S&F pre painted galvalume aluminum and zinc alloy coating with GI based corrugated steel sheet 0.50 mm thick of a colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F pre painted galvalume aluminum and zinc alloy coating with GI based plain steel sheet 0.50 mm thick of a colour having tensile strength of 550 Mpa as in ridges fixed with self tapping screws complete all as specified and directed.
S&F in repair suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner shall not be placed at more than 450mm from the adjacent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & as directed.
Taking down roof trusses, coupled rafters or trussed beams of clear span above 8.00 metres and upto 12.00 metres complete all as specified & as directed.
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound to be measured and paid separately as "Supply only".
Supply only integral water proofing compound complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of old treated surfaces on walls and sanding the surfaces till smooth finish is obtained and applying one coat of alkali resistant primer and two coats of oil bound distemper complete all as specified and directed.
M&L for complete removal of old treated surfaces on walls and sanding the surfaces till smooth finish is obtained and applying one coat of alkali resistant primer and two coats of cement base paint complete all as specified and directed.
M & L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and applying two coats of creosote complete all as specified and directed.
M&L Preparing surfaces of wood and wood based materials,steel/metal surface of any description and girth not other wise described and treating small articles such as stop covers gully gratings,holdfast ends of posts, backs of chowkats,with tar or coal tar black paint etc,area tarred not exc 0.1 sqm each complete all as specified & as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each including builders hardware complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware complete all as specified and as directed.
M&L 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F 30 mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
S&F second class hardwood 35mm thick plain framed panelled shutter ( any number of panels) with panels of timber flat on both sides ( feather edged) or of veneered particle board medium density wood particle board with commercial face veneers suppplied and fitted to the chowkats complete all as specified and directed.
S&F factory made steel windows with side hung shutters glazed, both side openable ( outside glazed window and inside fly proof window) including projecting type hinges with steel handle , and steel peg stay complete with glazing bars dovetailed or welded with 12mm dia square bars or round bar of approved design welded to steel window frame complete all as specified & as directed.
S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (with out sash bar), edges of framing with plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed.
S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (with out sash bar), edges of framing with plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed.
S&F PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tube for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stills and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ scaled to the stiles and rails with suitable PVC Sheet beading and jointed together with solvent cement as per drawings and specifications as catered in SSR Part – II 2020.
S&F 1.25mm thick pressed steel frame of size 125x60mm for doors/windows with single rebates including necessary fixing lugs, hinges, lock strike plates, filling in PCC !:3:6 type C-0 in hollow portion etc. complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240 with one shop coat of red oxide zinc chrome primer paint complete all as specified and directed.
S&F Rolled mild steel roof trusses ( framed) trussed purlins, crane gantries, rails and fastenings and heavy brackets framing ( Beam, tee, angle, channel or flat section) including distace pieces, cleats etc confirming to Fe 410-W ( Gde E-250 Quality A)complete all as specified & as directed.
S&FMild steel framed work such as grills,gratings,etc.with ends of bars shouldered and/or riveted,or forged into spikes,framed guard bars, barred iron doors,ladders, framed balusters, walk ways,railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165.
S&Fmild steel flat iron 25x3mm as in hold fast etc.
S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm in size extruded aluminium handles, fabricated type, anodised complete all as specified and directed.
S&F 100mm in size extruded aluminium handles, fabricated type, anodised complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and directed.
S&F butt hinges 100 mm long extruded aluminium alloy with galvanised mild steel hinge pin anodised complete all as directed.
S&F butt hinges 75 mm long extruded aluminium alloy with galvanised mild steel hinge pin anodised complete all as directed.
S&F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples complete all as specified and as directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane complete all as specified and directed.
Demolition of stone slabs and tiles of any description and thickness in floors, approns etc. complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4, type B0 (using 12.5mm graded stone aggregate) as in wearing course to receive top layer complete all as specified and as directed.
Polishing only to old kota stone flooring to the entire satisfaction of Eng In Charge complete all as specified and directed.
M&L for 20-25mm thick Kota stone slab flooring laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300mmx200mmx 6mm to 7mm /350mmx250mmx7m/450mmx350mmx7mm thick, set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as skirting, dados and risers to steps over and including 10 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for 20mm thick granite ( any type) machine cut ,as in steps, jambs, pillars, window cills, cookong platforms and the like laid over cement screed of 15mm thick in CM 1:4 including pointing in white cement 1:2 using marble dust with admixtures of pigments match the shade of granite stone including rubbing and polishing complete all as specified and as directed.
M&L coloured Non-skid ceramic tiles 7 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surfaces over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old surfaces of steel and steel based surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint r complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel and steel based surfaces of any description, not otherwise described not exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel and steel based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
Taking up or down 15 mm bore GI tubing from trenches / wall including all fittings segregated, cleaning and stacking the pipe for reuse at site if required complete all as specified and as directed. Note : Excavation and earthwork if any shall be included in the quoted rate
S&F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing only old serviceable 15 mm bore Steel tubing and connections as obtained from taking up/down old steel tubing including provision of new fittings in new or old position to walls,ceiling, flooring etc. complete all as specified and as directed.
Taking up or down 20 mm bore GI tubing from trenches / wall including all fittings segregated, cleaning and stacking the pipe for reuse at site if required complete all as specified and as directed.
S & F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing only old serviceable 15 mm bore Steel tubing and connections as obtained from taking up/down old steel tubing including provision of new fittings in new or old position to walls,ceiling, flooring etc. complete all as specified and as directed.
S&F in repair stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe.
S & F in repair 20mm bore, gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for union complete all as specified and directed.
S & F 15mm bore, gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repairs Bib taps 15mm dia fancy type cast copper alloy chromium plated, with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as directed.
S&F 500 litres capacity rotational moulded polye-thylene water storage tanks triple layer ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with and including 20 mm bore dia -ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed.
S&F 1000 litres capacity rotational moulded polye-thylene water storage tanks triple layer ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with and including 20 mm bore dia -ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc including dismantling of old tank of any description complete all as specified and directed.
S & F in repairs, vitreous china wash down water closet (padestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for padestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed.
S&F in repairs PVC low level flushing cistern 10 litres capacity with inlet ball valve, float and handles including brackets complete all as specified and directed.
S&F in repair CP swivel shower rose of 125 mm dia and suitable for fixing 15 mm bore iron pipe all as specified and directed.
S&Fgrating doom 125mmdia with waste hole of PTMT ( Minimum weight 40 gms) complete all as specified and directed.
S&F tubular towel Rail of 20mm dia and 60cm in length, D shaped, with brass chromium plated brackets complete all as specified and as directed.
S&F in repairs vitreous china soap tray embedded in wall white of approximate size 160x160x90mm complete all as specified and directed.
S&F in repairs 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall or in floor as in waste/soil pipe etc complete all as specified and directed
S&F 110 mm dia PVC (SWR) bends of any radius complete all as specified and directed.
S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
Taking down carefully aluminium/ copper point wiring for light/fan/ socket/bell or power point incl. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete removing materials to store for keeping in safe custody site or handed over to contractor as schedule of credit and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including concealed in PVC rigid conduit on walls/ceiling, and also including sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for One light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item No 109 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 109 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item No 109 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F switch piano, flush type single pole one way 5 Amps 240 volt complete all as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as directed.
S&F switch socket combination outlet , 2-in-1, 5 Amp flush type complete all as directed.
S&F switch socket combination multipurpose, 5 in 1, , 5 & 16 Amp flush type complete all as directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as directed.
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring complete all as specified and directed. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit shall be measured as one unit.
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit shall be measured as one unit.
S&Fin repair regal batten for LED Tube rod pre-wired including LED tube double sided 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on 2 no. of PVC block complete all as directed. (Make:- Havells, Model No: REGALBATTENT8UPTO1X22WDSBSWH+CRSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Bajaj / Philips / GE / Crompton)
S&F regal batten for LED Tube rod pre-wired including LED tube double sided 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on 2 no. of PVC block complete all as directed. (Make:- Havells, Model No: REGALBATTENT8UPTO1X22WDSBSWH+CRSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Bajaj / Philips / GE / Crompton)
S&F in repairs LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no of PVC block ccomplete as specified and directed.(Make:- Jaguar Model No. LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XW or Havells Model No. LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Crompton)
S&F in repairs LED recess mount downlighter 18 W with pressure die cast aluminium heat sink and PC diffuser in white powder coated finish with integrated driver. complete as specified and directed. (Make: Havells Model EDGEPRO, Cat No. EDGEPRORDDLR 18W LED 857S or equivalent of crompton/Bajaj/Philips)
Supply and fixing in repairs building security light bracket made of GI pipe 40 mm bore medium grade (bend to shape), 2.00 metre long and fixed with Ms flat iron clamp(clamp shall be 40 x 5mm), nuts, bolts and washers on pole complete all as specified and directed.
Supply and fixing in repair building security liminaires WSPD 48 Watts epoxy powder coated pressure die cast aluminium housing with weather proof gasket for LEDs and control gear compartments, pressure die cast aluminium frame with heat resistant toughened clear glass fixed with SS screws. CRee LED/Equivalent colour temp-5700 K +/-300 K lens , IP-66, lumen efficiancy >100, lm/w. surge protection, 4 KV internal ( built in) with twin core conductor complete all as specified and directed including testing on completeion. Make: Havells Cat No. ENDURAPEARNEOSL48WLED757SASYTOPC or equivalent in Philips/WIPRO/CG.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including demolition of old earthing complete all as specified and directed.
Taking down ceiling /wall / exhaust fans of any sweep carefully and and transporting from any location to MES E/M store yard and back after repairing and refixing in position duly painted with one coat of synthetic enamelled paint by spraying including filling cavities with filler connecting up after neccessary repair as directed. complete all as specified and directed.
S&F in replacement MCB DB, double door sheet metal enclosure SPN 8 way with 200 A rated bus bar complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCB DB, double door sheet metal enclosure SPN 8 way with 200 A rated bus bar complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in replacement MCCB DB, IP-43, double door sheet metal enclosure VTPN 4 way with 250 Amps rated copper bus bar 415 volt complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repair MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA, C-series marked fixing in DBs (DBs catered separately in this Schedule) (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA, C-series marked fixing in DBs (DBs catered separately in this Schedule) (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repair MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repair MCB Tripple pole & neutral 40 to 63 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F ceiling fan complete with blades, down rod, electronic regulator and accessories, 230 V , 1200mm sweep with minmum air delievery 210CFM with service value 6.00 BEE five star rated with bushless direct current motor ( BLDC) complete all as specified and directed. (Make Usha/Havells/ Orient)
Supply, install , commissioning and testing water cooler electric driven ( single phase) having approx storage capacity of 80 Litres and nominal cooling capacity of 40 litres per hour complete.Make Usha Model SS 40/80 NC or equivalent in Bluestar
S&F Electronic type Voltage stabiliser for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 130V to 280V with output voltage stabilized at 200-240 V with accuracy of 2.0% current carrying capacity of 4 Amps suitable for water cooler of capacity 40/80 litres with atleast 05 years warrenty complete all as specified and directed. Make V-Guard VG100 or equivalent.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
M/L cutting chases , pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,etc. and making good , cutting exceeding 10cm but not exceeding 20 cm girth complete all as specified and directed.
S&F GI tubing 25mm dia light grade for cable protection and fixing to existing pole with mild steel flat iron clamp of size 25x3mm including nuts bolts etc complete all as specified and directed.
M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and as directed.
LAXMI CONSTRUCTION
M/s Dhani Enterprise
M/s SHARMA BUILDERS & ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .