Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹38.0 L+₹4.1 L (11.9%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Nov 2022, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIRS MAINTENANCE AND REPLACEMENT OF SUMMER APPLIANCES AC PLANT AND DESERT COOLER AT CQA A PTL SQAE NAI UNDER AGE EM II IN GE CENTRAL KIRKEE
2022_MES_559640_1
8699/E8 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
CENTRAL area
Class D Category b(i) and c(i)
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹90,000
Yes
27 Nov 2022
25 Oct 2022
21 Nov 2022
25 Oct 2022
19 Nov 2022
7 Nov 2022
25 Oct 2022 - 5 Nov 2022
Amount
Material and labour for copper piping 5/8" (18/20 gauges) with necessary fittings such as elbow bends sockets and tee's , clamps and supports on walls and ground complete all as specified and as directed..
Material and labour for copper piping 1/2" with necessary fittings such as elbow bends sockets and tee's , clamps and supports on walls and ground all as specified and as directed..
Material and labour for copper piping 1/4" with necessary fittings such as elbow bends sockets and tee's , clamps and supports on walls and ground all as specified and as directed.
Material and labour for copper piping 5/8" superlone insulation with necessary fitting such as elbow bends sockets and tee's, clamps and supports on wall and grounds all as specified and as directed.
Material and labour for copper piping 1/2" superlone insulation with necessary fittings such as elbow bends sockets and tee's , clamps and supports on walls and ground all as specified and as directed..
Material and Labour for Copper piping 1/4" superlone insulation with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds all as specified and as directed..
Labour for shifting of split type air conditioner and fixing of air conditioner all as per directed by Engr-In-charge.
Material and labour for core cutting/drilling/chases cutting of wall up to 18 inch suitable for split type AC as per site requirment all as per directed by Engr-In-Charge.
Disconnecting split/window type AC (Outdoor+Indoor unit) 1.5/2 TR electrically/mechanically and lowering to the ground fixed in any position for servicing / repairing / overhauling /cleaning, and cleaning filters, checking of electrical wiring, cleaning of dust by blower and washing with washing soda including replacement of unserviceable, burnt out spare parts to make it fully functional, after repairs and re-installation and testing on full load complete to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. NOTE :- Item replaced will be measured and paid separately.
Material and labour for cleaning gas system of split AC /window type AC with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( Refrigerant R-22) including brazing/testing and commissioning complete of size 1.5/2 Ton capacity.
Material and labour for cleaning gas system of split AC/Window type AC with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( Refrigerant R-32) including brazing/testing and commissioning complete of size 1.5/2 Ton capacity.
Material and labour for cleaning of gas system of the water cooler/ refrigerator with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( R-134) including brazing/testing and commissioning complete of capacity 40/80/100/120 ltrs complete all as specified and as directed..
Material and labour for replacement of unserviceble & damaged burnt blower motor/fan motor Window/Split AC of capacity 1/6 HP complete all as specified and as directed..
All as per Sl Item No. 13 above but suitable for 1/4 HP capacitor complete all as specified and as directed.
Material and labour for replacement of unserviceble & damaged burnt blower motor/fan motor of Water cooler of capacity 1/8 HP complete all as specified and as directed.
All as per Sl Item No. 15 above but suitable for 1/3 HP capacitor complete all as specified and as directed.
All as per Sl Item No. 15 above but suitable for 1/2 HP capacitor complete all as specified and as directed.
Disconnecting Water cooler of 60/40/80/100/120 Ltr electrically/mechanically for repairing/overhauling/cleaning, checking of electrical wiring, cleaning of dust by blower including replacement of unserviceable, burnt out spare parts such as relays thermostates etc to make it fully functional, after repair and re-installation and testing on completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. NOTE :- Item replaced will be measured and paid separately.
Supply and fix micro processor printed circuit board complete suitable for split type AC of 1.5/2 TR as suitable for existing make/model and capacity 1.5/2 Ton complete all as specified and as directed..
Disconnecting and taking out old defective hermetically sealed compressor unit as required for AC/water coller/refrigerator and Material and labour for fixing new compressor (new sealed unit only) with nut bolt, washer antivibrating bush , brazing work, pressure testing for leakage, vaccumnsing and gas charging etc of capacity 1.5 TR for window/Split AC of the existing makes complete all as specified and as directed. MAKE :- Voltas/Hitachi/Emersion/Carrier /Shriram (Techmesh) .
All as per Sl Item No. 20 above but of capacity 2 TR for window/split AC
All as per Sl Item No. 20 above but suitable for Water cooler of capacity 40ltrs.
All as per Sl Item No. 20 above but suitable for Water cooler of capacity 60ltrs.
All as per Sl Item No. 20 above but suitable for Water cooler of capacity 80ltrs.
All as per Sl Item No. 20 above but suitable for Water cooler of capacity 100/120ltrs.
Supply and fix in replacement thermostate suitable for water cooler/ refrigerator/ AC of any type and any model complete all as specified and as directed.
Material and labour for replacement of overload protection relay for window AC, water cooler and refrigerator of make and model as per existing complete all as specified and as directed.
Material and labour for replacement of starting relay for window A/C water cooler & refrigaretor of make and model as per existing complete all as specified and as directed.
Supply and fix in replacement of running capacitor 10 MFD complete all as specified and as directed.
Supply and fix in replacement of running capacitor 25 MFD complete all as specified and as directed.
Supply and fix in replacement of running capacitor 36 MFD complete all as specified and as directed.
Supply and fix in replacement of running capacitor 40/45 MFD complete all as specified and as directed.
Supply and fix in replacement of starting capacitor 60 MFD complete all as specified and as directed.
Supply and fix in replacement of starting capacitor 80/100 MFD complete all as specified and as directed.
Supply and fix in replacement of starting capacitor 120 MFD complete all as specified and as directed.
Supply and fix in replacement of PVC float valve for water cooler of size 15mm dia complete all as specified and as directed.
Supply and fix in replacement of drier filtter for AC/water cooler/refrigerator.
Supply and fix in replacement of capillary tubing of any size not less than 0.5 mtr for AC/Water cooler/refrigerator complete all as specified and as directed.
Supply and fix for PVC drain pipe suitable for water cooler outlet of any capacity complete all as specified and as directed.
Supply and fix in replacement 3 pin plug top of capacity 15 Amps complete all as specified and as directed.
Supply and fix of copper condenser unit assembly for window AC with all accessories complete of capacity 1.5/2 ton complete all as specified and as directed.
Supply and fix in replacement of suction valve for split AC of any capacity complete all as specified and as directed.
Supply and fix for PVC drain pipe suitable for split AC out let of 1.5T/2.T capacity complete all as specified and as directed.
Supply and fix in replacment of discharge valve for split AC of any capacity complete all as specified and as directed.
Supply and fix in replacement of rubber gasket for lid top of any size for water coolers complete all as specified and as directed.
Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for refrigirators with bushes, sleeves, washers nut and bolt for Compressor foundation legs, relay terminal cover clips and including cutting, brazing, leak detection, charging refrigerent and commissioning testing for 165 - 200 ltr capacity complete all as specified and as directed.
Disconnecting electric conections, removing / transporting the un serviceable water cooler of capacity 40 ltrs to 120 Ltrs to workshop for painting work which includes removing the existing deteriorated / rusted body for paint by scrapping and filling of cavaties with filler spray, denting/ welding, patch work with existing size of MS sheet and painting the body with synthetic enamel paint with two coats over a coat of redoxide primer and marking the SM/MES No (of reqd size and shape) with black paint complete all as specified for as directed by Engr-in-Charge.
Material and labour for dismantling of existing unservicebale voltage stablizer for repairs with replacement of relays electronic voltage sensor circut and meter, micro switch, indication light RC filters and other connected items for making functional and rewinding of unserviceable transformer with super enameled copper wire of appropriate size, varnishing assembling and testing completeof capacity 2 KVA to 5 KVA upto satisfactory function of any capacity all as specified and as directed. by Engr- in-Charge.
Supply and fix of heavy duty air conditioner outdoor unit stand / brackets with complete accessorise for windows / split type AC of capacity of 1.5/2 Ton complete with grouting nut bolts all as specified and as directed by Engr-in-charge .
Supply and fix in replacement of copper condenser unit assembly for outdoor unit with all accessories suitable for split AC of capacity 1.5/2 ton complete all as specified and as directed.
Dismantling of old split type air conditioner indoor unit and Supply , installation and testing Indoor unit of split type air conditioner complete with cordless remote control and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 Ton with wall mounted fixing plate suitable size incl brazing work for fixing existing site complete all as specified and as directed. MAKE :- Voltas / LG / Blue star
Disconnecting and taking down unserviceable/damage outdoor unit cover of split air conditioner of capacity 1.5 Ton and dismantaling of compressor ,condenser unit,wiring,fan motor from outdoor cover and Supply and fix new outdoor cover with replacement of unserviceable spare parts such as capacitor ,control wiring and refixing compressor ,condenser unit,wiring,fan motor to make it fully functional, after repair and re-installation as per existing and testing on completion to the entire satisfaction of Engr-in-Charge. NOTE :- Items as declared unservicable by Engineer in charge shall be measured and paid separately.
Supply and fix sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 4 sq.mm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness of suitable size including all fixing accessories, and 4 sq.mm PVC insulated stranded copper conductor cable as earth wire connected to earth dolly complete all as specified and as directed. NOTE :- Both running cables including earth wire including one run PVC conduit pipe shall be measured & paid for as single length.
Supply and fix sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 6 sq.mm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness of suitable size including all fixing accessories, and 6 sq.mm PVC insulated stranded copper conductor cable as earth wire connected to earth dolly complete all as specified and as directed. NOTE :- Both running cables including earth wire including one run of PVC conduit pipe shall be measured & paid for as single length.
Supply and fix of MCB's 240V conforming to IS of rating 6A to 32A SP, ' C' Series, 10 KA breaking capacity complete all as specified and as directed.
Supply and fix sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earth plug and socket complete with one no MCB SP, 20 Amps, 230 volts complete all as specified and as directed.
Supply and fix in repairs first aid box at E/M installations to keep the first aid items i.e. tube of bernol, bandage, one small snizer, bandage etc, the box made out of GI sheet of 18 gauge of size 30 cm X 25 cm x 20 cm with openable window & writing letters "FIRST AID" with thick red paint and fixed on wall at height not less than 2 mtr complete all as specified and as directed by Engineer- In- Charge.
Supply and fix in repairs CI Pot Strainer/ Y Stainer with matching flanges, gasket, hardware of 150 mm bore all as specified and directed.
Supply and fix in repairs installation informatory boards at E/M installation to display the technical details i.e.(type of AC plant, capacity, design condition, date of installation, Installed by, compressor type, Compressor motor, Condensor motor, AHU motor, cooling tower motor, AHU motor and if chilled water type chiller motor) of AC plant made out of 3mm thick aluminium composite panel (ACP) fully covered with white/green/blue (as required) Retro Reflective sheeting of Nikkalite Brand Ultralie (UL) grade with using pressure sensitive adhesive and Retro Reflective cut out border and messages in the sensitive adhesive, size of the board 150 cm x 120 cm fixed on wall above 1.2 mtr above ground level with & including proper fixing arragement complete all as specified and directed. NOTE :- Technical details as per direction of Engr-in-charge.
Disconnecting water connections to the condenser of package/central A/C plant of following capacity by dismantling the both end cover of condenser. Descaling the condenser of compressors with dilute sulphuric acid , flushing/cleaning with brush and water, re-fixing the side cover with new gasket nut / bolts and detect leakage all as specified and directed by Engr-in-Charge. NOTE :- Dilute sulphuric acid for descaling is deemed to be included in the quoted rates.
Material and Labour for Servicing/Cleaning of FRP cooling tower of 100 TR by dismantling top cover, fan with fan motor and removing the honey comb frills. Cleaning of base tray & frills, pot strainer etc. servicing of fan motor with changing of bearings and greesing refixing the fan, frill & top cover testing commissioning complete all as directed by Engr-in-charge. NOTE :- Spares as required during the servicing and repairs as declared unservicable by Engr in charge shall be mesured and paid under relavant items of this schdule.
Disconnecting/Isolating the compressor of make :- Voltas 05060S model from the system by putting plates to the suction and discharge valve opening of the compressor. Dismantling the compressor completely by taking down the crank shaft. Removing unserviceable internal parts cleaning overhauling complete replacement of worn out parts such as suction reed, discharge reed, cylinder liners, loading/unloading system of compressor, washers, nut bolts, gaskets shaft seal, "O" rings, cutting, metalizing, grinding, balancing the crank shaft and reassembling the compressor including changing the compressor oil, leak testing with nitrogen, repairing leakages and charging R-22, gas, testing/comissioning complete for following compressor make Accel sabro/Kirloskar, complete all as directed by engineer in charge. Note : Spare parts , R-22 gas, compressor oil and nitrogen gas shall be measured and paid separately under respective items.
Supply and fix in replacement of following spares for compressor all as specified and directed . a) Piston MAKE :- Voltas 05060S model.
b) Piston ring
c) Pisotn pin
d) Shaft seal assembly
e) Discharge valve reeds
f) Loading Unloading Frame
g) Main bearing Bush
h) CR bearing
j) Gasket set for 05060S
m) Aluminium washer set
n) Oil pump assembly
o) Oil ring
p) O Ring set
q) Solenoid valve for loading & unloading
r) Split pin
s) Sunction valve reed
t) Thrust collor
u) Oil filter
v) Cylinder liner
w) Oil drain valve
x) Bushing for connecting rod
Supply and fix nitrogen gas for leak testing of central & package A/C plants all as directed by Engineer in charge.
Supply and fix of R-22 Gas in central & package A/C plants all as directed by Engineer in charge.
Supply and fix compressor oil suitable to air conditioning plants compressor and taking out old dirty compressor oil, cleaning the crank case and oil filter as specified and directed by Engineer in charge
Supply and fix in replacement of defective brassomatic pressure release valve of suitable size for 300 PSI refrigerent gas pressure complete all as specified and as directed.
Supply and fix in replacement of over load relays type MN relay range 14-23 A complete all as specified and as directed. MAKE :- L&T or equvilant to BCH/SIMENS
Supply and fix in replacement of over load relays type MN relay range 24-40 A complete all as specified and as directed. MAKE :- L & T or equvilant to BCH/SIMENS
Supply and fix MCCB 63 Amps 25KA, TP (ICS=100%ICU) with adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and as directed. MAKE :- L&T or equvilant to ABB/Legrand
Supply and fix MCCB 100 Amps 36KA, TP (ICS=100%ICU) with adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and as directed. MAKE :- L&T or equvilant to ABB/Legrand
Supply and fix MCCB 125 Amps 36KA, TP (ICS=100%ICU) with adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and as directed . MAKE :- L&T or equvilant to ABB/Legrand
Supply and fix MCCB 200 Amps 36KA, TP (ICS=100%ICU) with adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and as directed . MAKE :- L&T or equvilant to ABB/Legrand
Supply and fix MCCB 200 Amps 36KA, FP (ICS=100%ICU) with adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and as directed . MAKE :- L&T or equvilant to ABB/Legrand
Supply and fix MCCB 250 Amps 36KA, FP (ICS=100%ICU) with adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete. MAKE:- L & T or equvilant to ABB/Legrand. NOTE for Sl Item No 18.00 to 23.00 - (i) All cable connections should be done with Supply and fixing suitable size lugs/thimble etc. (ii) Any addition / alteration to sheet metal enclosure existing panel for fixing of MCCBs and removal of old un serviceable switch gear is deemed to be included in the rates quoted rate..
Supply and fix in replacement of following spares for central AC plant :- (a) Indicating lamps RYB - 01 Set
(b) 'V' belt of size / No A 1052 LP/A 40 MAKE:- Fenner
(c) 'V' belt of size / No A 925 Lp/A 35 MAKE:- Fenner
(d) Power contactors ML A2 MAKE :- L&T or equvalant to Simens/BCH
(e) Power contactors MNX 12 MAKE :- L&T or equvalant to Simens/BCH
(f) Power contactors MNX 18 MAKE :- L&T or equvalant to Simens/BCH
(g) Power contactors MNX 45 MAKE :- L&T or equvalant to Simens/BCH
(h) Power contactors MNX 70 MAKE :- L&T or equvalant to Simens/BCH
Labour only for detection of leakage and repairing of central type AC Plant of capacity 100 TR capacity by leak testing, leak repairing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results complete all as specified and as directed. NOTE :- Nitrogen gas and refrigerant will be measured and paid separately.
Dismantling of Air Handling Unit of any capacity with complete accessories such as cooling coil, air filters, blower motor, blower / drum, blower shaft, side panels, and wall opening if required etc including removing of electric connection and dismantling of pipe work of any size and type by using gas cutter or Electric cutter complete all as specified and as directed .
Re-assembling/Refixing the complete Air Handling Unit of any capacity after carring out cleaning, servicing to cooling coil, blower & filters by using CTC solution including remetling, fine grinding blower shaft and hardening balancing, realignment to AHU shaft, replacing unserviceable blower fins, replacing bearings 2 Nos including inlet out let pipe welding,all electric connections and leak testing by using nitrozen gas and testing and commissioning all as specified and as directed by Engr-in- Charge
Supply and fix Cast Iron sluice valves class PN 1.6 of size 150mm dia (6") including gasket, nut bolts, handle with cuting of CI pipe fabrication work as per site requirment & including removal of un serviceable sluice valves complete all as specified and directed Engr-in-Charge.
Supply and fix Cast Iron sluice valves class PN 1.6 of size 100mm dia (4") incl gasket , nut bolts,handle with cuting of CI pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
Supply and fix Cast Iron sluice valves class PN 1.6 of size 80mm dia (3") incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and as directed Engr-in-Charge.
Taking out unserviceable liquid line valve/discharge line valve from refrigerant line of different size/type for necessary replacement all as directed including cutting / welding of existing pipe line complete all as specified and as directed.
Supply and fix liquid line valve/discharge line valve as per existing including providing Gasket/Teflon/bushing to both side sheet, suitable for 40 mm dia pipe line including brazing/welding, fixing all as specified and as directed .
Supply and fix liquid line valve/discharge line valve as per existing including providing Gasket/Teflon/bushing to both side sheet, suitable for 25 mm dia pipe line including brazing/welding, fixing all as specified and as directed .
Supply and fix liquid line valve / discharge line valve as per existing including providing Gasket/Teflon/bushing to both side sheet, suitable for 20 mm dia pipe line including brazing/welding, fixing all as specified and as directed .
Supply and fix thermostate expansion valve of suitable size for 100TR capacity air conditioning plants including taking down the unserviceble valve complete all as specified and as directed .
Supply and fix water pressure gauge 0-7 Kg/Sqm including taking down the unserviceble gauge complete all as specified and as directed .
Supply and fix refrgerant pressure gauge 30 to 150 PSI including taking down the unserviceble gauge complete all as specified and as directed .
Supply and fix in replacement of pressure release valve of condensor 3/8" BSP threaded suitable for 300 PSI complete all as specified and as directed .
Supply and Fix in replacement of DB/WB thermometer wall mounted with the facility of RH readings.
Taking down carefully and overhauling of monoblock pump set by disconnecting the pump from foundation and pipe line, dismantling of shaft from the pump, replacing the unserviceable worn out bearing, gland packing, seal and bushing and assembling after repairs complete testing for the pump of capacity 7.5 HP to 10 HP complete all as specified and as directed .
Material and labour in replacement of 50mm bore GI pipe medium grade incl all fittings and acessories complete all as specified and as directed .
Material and labour in replacement of 40mm bore GI pipe medium grade incl all fittings and acessories complete all as specified and as directed .
Material and labour in replacement of 25mm bore GI pipe medium grade incl all fittings and acessories complete all as specified and as directed .
Material and labour in replacement of 20mm bore GI pipe medium grade incl all fittings and acessories complete all as specified and as directed .
Supply and fix gate valves (brass insert) of 50 mm bore, ISI marked, heavy duty including taking down old one complete all as specified and as directed .
Supply and fix gate valves (brass insert) of 40 mm bore, ISI marked, heavy duty including taking down old one complete all as specified and as directed .
Supply and fix gate valves (brass insert) of 25 mm bore, ISI marked, heavy duty incl taking down old one complete all as specified and as directed .
Supply and fix gate valves (Brass Insert) of 20 mm bore, ISI marked, heavy duty including taking down old one complete all as specified and as directed .
Supply and fix float valve/ball type assembly complete of size 20 mm size dia complete all as specified and as directed .
Painting of CI/GI/MS pipes of air / water distribution of size 100 / 80 mm dia along with side supports complete with two coats of synthetic enamel paint all as per colour code and as directed by Engr-in-Charge.
Material and labour painting to cooling tower inside and outside with one coat of primer and one coat of epoxy paint of approved colour including scrapping out the old paint complete all as specified and and as directed by Engr-In-charge.
Material and labour for preparation of surfaces for painting of compressor unit of capacity up to 100 TR with motor, one coat of synthetic enamel paint including painting to suction line, discharge line, liquid line, guard base foundation etc. all as specified and as directed.
Material and labour for rolled mild steel as in brackets, frames supports, channels and stands of type as required at site made out of angle iron, flat or strip of grade Fe-410-S of any size as per site requirement for PGI air duct etc complete all as specified and as directed by Engr-in-charge .
Supply and fix double knitted polymer fabric HDPE fresh air filter of sizes 610 x 610 x 50 mm, washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coats of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, box/flanged type, aluminium spacer etc, all as specified by engr-in-charge.
Supply, laying, commissioning and testing XLPE insulated, armoured heavy duty electric cable aluminium conductor, 1100 volt cross sectional area 70 sq.mm 3.5 core including removing unserviceable/old cable complete all as specified and as directed. MAKE :- Polycab/Finolex /Paragaon/Havells
Supply, laying, commissioning and testing XLPE insulated, armoured heavy duty electric cable aluminium conductor, 1100 volt cross sectional area 50 sq.mm 3.5 core including removing unserviceable/old cable complete all as specified and as directed. MAKE :- Polycab/Finolex /Paragaon/Havells
Supply, laying, commissioning and testing XLPE insulated, armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 35 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed. MAKE:- Polycab/Finolex /Paragaon/Havells
Supply, laying, commissioning and testing XLPE insulated, armoured heavy duty electric cable aluminium conductor, 1100 volt cross sectional area 25 sq.mm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed. MAKE :- Polycab/Finolex /Paragaon/Havells
Supply, laying, commissioning and testing XLPE insulated, armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 16 Sqmm 4 core incl removing unserviceable/old cable complete all as specified and as directed. MAKE :- Polycab/Finolex /Paragaon/Havells
Supply, laying, commissioning and testing XLPE insulated, armoured heavy duty electric cable aluminium conductor, 1100 volt cross sectional area 6 sq.mm 3 core incl removing unserviceable/old cable complete all as specified and as directed. MAKE :- Polycab/Finolex /Paragaon/Havells
Material and Labour for disconnection / dismantling of electric motor 3 Phase, 415 volts, from installation & transporting to workshop for rewinding, taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 7.5 HP to 12.5 HP all as specified and directed.
Material and Labour for for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding, taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 40 HP to 60 HP all as specified and directed.
Material and labour for fabrication and installation of glow sign board (640 cm x 91cm x 25cm) made of flex / acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having with intenal tube light fitting arrangement to open the flex / acrylic board and suitable for mounting on wall/ gate complete all as directed by engr-in-charge. NOTE :- The cost of fabrication and welding work is included in the quoated rate .
Material and labour for fabrication and installation of Sign board (240 cm x 91cm x 25 cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having arrangement to open the flex/Acrylic board and suitable for mounting on wall complete all as directed by engr-in-charge. NOTE :- The cost of Fabrication and welding work is included in the quoated rate .
Supply and fix of hony comb frills of FRP cooling tower of any capacity by dismantling top and bottom honey comb frills size of frill as per site requirment, testing commissioning complete all as directed by Engr-in-charge. NOTE :- The cost all required material is included in the quoted rate .
Supply and fix Mild steel pipe heavy grade of 100 mm dia with all fitting laid in floors and fixed to walls and ceilings etc of sizes as shown complete all as specified and directed by Engr-in-charge
Supply and fix Mild steel pipe heavy grade of 80 mm dia with all fitting laid in floors and fixed to walls and ceilings etc of sizes as shown complete all as specified and directed by Engr-in-charge
Material and labour for removal of thermocoal insulation along with cement concrete carefully & scrubbing of old MS pipe of any size and applying two coats of anti corrosive paint complete all as specified and as directed by Engr-in-charge
Material and labour for insulation of MS pipes of any size with Nitrile rubber insulation of 25mm thick with and applying bituminous compound complete all as specified and as directed by Engr-in-charge
Material and labour for fibre glass cloth at nitrile rubber insulation on any size of pipe Complete all as specified and as directed by Eng-in-Charge.
Material and labour for insulation of MS pipes of any size with cladding of 26 SWG aluminium cladding sheet complete with all bends, fittings all as specified and as directed by Engr-in-charge.
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .