Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H8₹35.4 L−₹5.6 L (13.6%)Accepted-AOC ANURAGPUR PO PANAGARH BAZAR DIST BURDWAN WEST BENGAL 713 148 | PANAGARH BAZAR | BURDWAN | WEST BENGAL | 713148 | H8 | Accepted-AOC Contract awarded to M/s Unique Enterprises being lowest bidder | |
| 2 | H1₹41.0 LRejected-Finance VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | H1 | Rejected-Finance Higher rate quoted than H8 | |
| 3 | H2₹39.8 L−₹1.2 L (2.93%)Rejected-Finance VILLAGE PO BUD BUD DIST BURDWAN WB PS BUD BUD PIN 713403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | H2 | Rejected-Finance Higher rate quoted than H8 | |
| 4 | H3₹38.6 L−₹2.4 L (5.84%)Rejected-Finance | H3 | Rejected-Finance Higher rate quoted than H8 | |
| 5 | H4₹38.3 L−₹2.7 L (6.52%)Rejected-Finance | H4 | Rejected-Finance Higher rate quoted than H8 |
| Sl No | Description | Qty | Unit | UNIQUE ENTERPRISE H8 | Jaibalaji Enterprise H7 | MS ROYAL CONSTRUCTION INDEX NO 158 2010 BKP H6 | M/S SEHGAL CONSTRUCTION H3 | NATIONAL CONSTRUCTION CO H1 | S.P.S. SUPPLIERS H5 | M/S DYNAMIC INDIA (PROJECT) CONSTRUCTION H4 | rahul enterprise H2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor hearth or wall tilling including cement mortar bedding, removing rubbish off the premises complete all as specified and directed. | 320 | Sqm | 15 ₹4,800 Lowest | 20 ₹6,400 | 22 ₹7,040 | 35 ₹11,200 | 45 ₹14,400 | 25 ₹8,000 | 30 ₹9,600 | 40 ₹12,800 |
| 2.00 | Demolition of cement concrete (un-reinforced) not exceeding 15 cm thickness of any description and in any position not otherwise specifically provided forcomplete all as specified and directed. | 48 | Cum | 319 ₹15,312 Lowest | 322 ₹15,456 | 350 ₹16,800 | 380 ₹18,240 | 420 ₹20,160 | 352 ₹16,896 | 360 ₹17,280 | 400 ₹19,200 |
| 3.00 | M&L for 100 mm thick PCC 1:2:4, type B1, (using 20 mm graded crushed stone aggregates) as in sub base for receiving floor finish with or with out nominal reinforcement all as specified and directed. Reinforcement will be measured and paid seperately. | 384 | Sqm | 711 ₹2,73,024 Lowest | 725 ₹2,78,400 | 750 ₹2,88,000 | 800 ₹3,07,200 | 850 ₹3,26,400 | 762 ₹2,92,608 | 780 ₹2,99,520 | 820 ₹3,14,880 |
| 4.00 | M&L out door Vitrified parking tile of size 60 x 60 cmx 10 mm thick tiles of approved size,set ,jointed and pointed using with grey cement and pigment in floors, pavings etc including the setting and jointing in neat cement plaster or slurry 0.3 kg/sqm over 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as per specification complete all as specified and directed. | 64 | Sqm | 1,580 ₹1,01,120 Lowest | 1,592 ₹1,01,888 | 1,600 ₹1,02,400 | 1,600 ₹1,02,400 | 1,650 ₹1,05,600 | 1,620 ₹1,03,680 | 1,655 ₹1,05,920 | 1,620 ₹1,03,680 |
| 5.00 | M&L Non Skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in floors etc , over & including 15 mm thick cement mortar (1:6) screed etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified. | 320 | Sqm | 1,420 ₹4,54,400 | 1,428 ₹4,56,960 | 1,450 ₹4,64,000 | 1,400 ₹4,48,000 Lowest | 1,450 ₹4,64,000 | 1,440 ₹4,60,800 | 1,445 ₹4,62,400 | 1,420 ₹4,54,400 |
| 6.00 | M&L for non skid ceramic tiles coloured 7 to 8 mm thick(square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in vertical surfaces such as skirting etc, set and jointed with neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tiles over and including 10mm thick screed in cement mortar (1:4) complete, all as specified complete all as specified and directed. | 15 | Sqm | 1,400 ₹21,000 Lowest | 1,428 ₹21,420 | 1,450 ₹21,750 | 1,430 ₹21,450 | 1,450 ₹21,750 | 1,440 ₹21,600 | 1,450 ₹21,750 | 1,420 ₹21,300 |
| 7.00 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. | 4 | Cum | 316 ₹1,264 Lowest | 322 ₹1,288 | 350 ₹1,400 | 400 ₹1,600 | 450 ₹1,800 | 345 ₹1,380 | 350 ₹1,400 | 420 ₹1,680 |
| 8.00 | M&L for fly ash brick straight or curved on plan exc 6 mtr mean redious built in CM 1:6 ,including demolition of brick work built in cement mortar including all quoins, arches, pillar etc all as specified and directed. | 9 | Cum | 7,500 ₹67,500 Lowest | 7,550 ₹67,950 | 7,600 ₹68,400 | 8,000 ₹72,000 | 8,200 ₹73,800 | 7,525 ₹67,725 | 7,610 ₹68,490 | 8,100 ₹72,900 |
| 9.00 | M&L for RCC 1:1.5:3 type A1 (20 mm graded crushed stone aggregate) nominal mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete as directed. | 1.9 | Cum | 7,456 ₹14,166.4 Lowest | 7,500 ₹14,250 | 7,600 ₹14,440 | 7,700 ₹14,630 | 8,200 ₹15,580 | 7,525 ₹14,297.5 | 7,625 ₹14,487.5 | 8,000 ₹15,200 |
| 10.00 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter | 7.5 | Sqm | 419 ₹3,142.5 Lowest | 450 ₹3,375 | 466 ₹3,495 | 525 ₹3,937.5 | 550 ₹4,125 | 465 ₹3,487.5 | 500 ₹3,750 | 530 ₹3,975 |
Tender Value
₹39.8 L
EMD Value
₹79,600
Closing Date
26 Mar 2026, 6:00 pmClosed
GE PANNGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DISTT- BURDWAN, STATE-WEST BENGAL PIN-713420
All as per BOQ
2026_MES_755479_1
8500-542/E8
Open Tender
Civil Works
Works
180 days
PANNGARH
As per tender documents
6 documents required · 6 mandatory
₹500
GE Panagarh
₹79,600
31 Mar 2026
7 Mar 2026
27 Mar 2026
7 Mar 2026
26 Mar 2026
20 Mar 2026
Dismantling floor hearth or wall tilling including cement mortar bedding, removing rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (un-reinforced) not exceeding 15 cm thickness of any description and in any position not otherwise specifically provided forcomplete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4, type B1, (using 20 mm graded crushed stone aggregates) as in sub base for receiving floor finish with or with out nominal reinforcement all as specified and directed. Reinforcement will be measured and paid seperately.
M&L out door Vitrified parking tile of size 60 x 60 cmx 10 mm thick tiles of approved size,set ,jointed and pointed using with grey cement and pigment in floors, pavings etc including the setting and jointing in neat cement plaster or slurry 0.3 kg/sqm over 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as per specification complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in floors etc , over & including 15 mm thick cement mortar (1:6) screed etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified.
M&L for non skid ceramic tiles coloured 7 to 8 mm thick(square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in vertical surfaces such as skirting etc, set and jointed with neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tiles over and including 10mm thick screed in cement mortar (1:4) complete, all as specified complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
M&L for fly ash brick straight or curved on plan exc 6 mtr mean redious built in CM 1:6 ,including demolition of brick work built in cement mortar including all quoins, arches, pillar etc all as specified and directed.
M&L for RCC 1:1.5:3 type A1 (20 mm graded crushed stone aggregate) nominal mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete as directed.
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M & L for TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers and binders complete all as specified and directed.
S&F mild steel ladders ; farmed balusters, walk ways, railngs,conforming to grade Fe 410-0 etc complete all as specified.
M&L for preparing of new steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone walls and ceiling ,chajja, landing etc including racking of joints hacking for key scrubbing down with water etc complete all as specified.
M&L for prepartion of old surface and applying two coats of Super Latex (Sika or equivalent) @ 80gm per sqm per coat in the ratio of 1:1.5:5 (latex : water : cement) over internal/external of brick/concrete surface after cleaning and washing the surface by wire brush and plenty of water The entire surface shall be washed throughly with plenty of water and then allowed to dry complete all as specified and as directed. Note:- The entire process to be executed through authorised applicator.
M&L for Rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete surfaces finished fair and even, mixed wth water proofing compound admixture (if directed) as per manufacturer's instruction, complete all as specified and directed. Note :- WPC will measuered and paid separatly under relevant item of schedule.
Supply only integral water proofing compound, complete all as specified and directed.
M&L for 15 mm thick cement plaster in cement mortar (1:6) as on walls, finished fair and even complete all as specified and directed.
M&L Rendering 5 mm thick on fair faces of concrete surfaces, finished fair and even on ceiling/chajja/pillar in cement mortar (1:3), complete all as specified. complete all as specified and directed.
Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. over and including a coat of primer and 1.0 mm thick white wall care putty (premium quality) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified and directed.
M&L for applying three coats of white washing including preparation of new or previously untreated surfaces of ceiling complete all as specified and directed.
Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including a coat of 1.5 mm thick white wall care putty (premium quality) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified and directed.
Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm ) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified and directed.
M&L for preparing of new plastered surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of plastic emulsion paint over a coat of primer complete all as specified and as directed.
Taking down chowkhats or frame not exceeding 1.5 Sq. m each with shutter(s) (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhats or frame exceeding 1.5 Sq. m but not exceeding 4 Sq. m each with shutter(s) (without taking off shutters from the frame),complete all as specified and directed.
S&F Powder coated aluminium (miimum thickness of powder coating 50 micron) work for doors, windows, ventilators frame and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per the directions of Engineer-in-Charge
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-chargeher for openable/sliding shuttters) including all necessary fittings as directed
M & L for Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as specified and as directed.
S&F Sheet glass 4.8 mm thick, ordinary quality & glazing with oil putty in square but n.exc 0.5 sq.m in each pane complete all as specified and as directed.
S&F Sheet glass 4.8 mm thick, ordinary quality & glazing with oil putty in square but exc 0.5 sq.m in each pane complete all as specified and as directed.
S&F brass 4-levers mortice lock, vertical type , size 100mm complete all as spcified and as directed.
S&F in repair Aluminium (extruded section) body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg complete all as specified and as directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M & L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ howkhat of size 50x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
S & F 35mm thick Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size c mprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
Dismantling of Asbestos cement (Corrugated, semi corrugated, etc.) sheet in roof covering Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof in roof coverings complete all as specified and directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified any height Mtr height including all necessary scaffolding and safety measures complete all as specified and directed
Dismantling of wall or ceiling borads of any thickness including cover fillet complete all as specified and as directed.
S&F anodised aluminium snap grid of size 605 x 605 mm frame work for false ceiling snap grid frame including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete with and including 6 mm thick non asbestos fibrecement designer building boards fixed or laid/ inserted to Aluminium frame work with screw fixed in ceiling flat or sloping i complete all as specified.
M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand as in plinth protection complete all as specified.
M&L for PCC 1:3:6 type C1 using 20mm garded stone aggregate as in surface channel all as specified and directed.
M&L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.
M&L for repair to crack portion with jacktting technuque, taking down existing plaster up to brick wall surface of min 200 mm wide, cleaning to loose particles on surface of brick work along the length of crack and filling the gap/crack area with PCC 1:1.5:3 type A0 using 12.5 mm aggregate up to brick surface and inserting the welded mesh of size 25 x 25x 2 mm dia along the crack on both side of the wall surface fixed with, drilling holes 10 mm dia on either side of the crack by means of drilling machine through out the full width of the wall @ 25 cm c/c and insert 8/10 mm dia rod in the drilled holes, welded with horizontal rod to with hold the welded mesh and applying grit plaster 1:1:2 using 4 mm and down aggregate finished even and smooth without using extra cement complete all as specified and directed. (Note: Reinforcement and welded mesh deemed to be included in the quoted rates )
M&L green Marble work 16 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrana Adanga complete all as specified and as directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.® complete all as specified and directed.
Taking down carefully point wiring for one light, socket or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall, ceiling etc including seperating serviceabel light fittings, switches etc and keeping in safe custody for reuse and removal of unserviceable materials from site complete all as specified and directed.
M & L for concealed point wiring for fan/light point controlled by one one way switch complete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour) and connected to common earth dolly including sunken in GI terminal box 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets ect. Note : a) Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
All as per BOQ item No 50.00 here-in-before but for one power pointt using by 2.50 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 2.50 sq mm conductor for earth continuity (Green Colour) , on independent board ( but Not below the switch board of light points in the same vertical plane).
All as per item No 50.00 above but for one 6 pin multi purpose 5/6 Amps socket outlet on the same board with other switches.
All as per BOQ item No 50.00 here-in-before but for one power pointt using by 4.00 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 4.00 sq mm conductor for earth continuity (Green Colour) , on independent board ( but Not below the switch board of light points in the same vertical plane).
Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified.
Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
S&F socket outlets 2 in 1, 5 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed .( For Same Board only)
Supply and fixed switch socket combination 5 in 1 , 6 pin , (5/16 Amps ) flush type controlled by one switch complete all as specified.
Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply & fix stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified.
Supply and fix Decorative wall light, fixture made up of polycarbonate suitable for 9W LED lamp including Bulb of LED 9W B22 base complete all specified and directed.
Supply and fixing in repairs ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) (Old U/s ceiling fan to be deposited in MES Store Yard)
Supply and fixing for concealed type sub main wiring with two run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. including one run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC conduit, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
Supply and fixing for concealed type sub main wiring with two run of 6.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. including one run of 6.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC conduit, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
S & F in repair LED street lights nominal power 35 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S&F in repairs LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note (i) Make of batten and LED tube lamp should be of same make.
S&F recess mounting luminaire (PANEL LIGHTING) with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling Fixture size: (LxW) in (600 x 600) mm LED 36 Watt with CRCA powder coated housing (white after phosphochromate treatment) High efficiency long life LED package in integral module with lumen efficacy of >120 lm/W and viewing angle of 120° to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per IS:15885 Part 2/Sec 13. operational voltage of 170 volts to 270 volts, frequency of 50 Hz, protection grade IP 20, CRI greater than or equal to 80%, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, including taking down old unserviceable complete all as specified & directed:
S&F in repairs VTPN distribution board with provision for 4 pole MCCB up to 160A as incomer with three phase and single phase (TP/SP) MCB outgoing with and including insulated busbar (tinned electrolytic copper) arrangement, shrouded neutral bar and earth bars, Top and bottom removable gland plates with knockouts, 4 way, Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.
Supply and fix MCCB 4 pole , 415 volts of capacity 63 Amps with breaking capacity of 16 KA fixed thermal and fixed magnatic setting including necessary connection complete all as specified and as directed.
Supply and fixed MCB SPN 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Supply and fixed MCB SP 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 15 mm dia GI pipe (medium grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protectionh GI pipe of 15mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire including protection pipe, from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
Supply and fixed D clamp of strip size 25x6 mm with suitable washer,nuts, bolts in any shape or size as indicated or directed including making hook for hanging ceiling fan and inclusive of one primer coat ,one under coat, one finish coat of paint complete for hanging of ceiling fan all as specified and as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
PS542.pdf
Tender Documents • 1.30 MB
BOQ_846197.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .