Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.5 LAccepted-AOC 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L1 | Accepted-AOC Accepted for award of contract | |
| 2 | L2₹58.4 L+₹8.5 L (17.1%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹61.7 L+₹11.8 L (23.8%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹62.4 L+₹12.5 L (25.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹69.3 L+₹19.5 L (39.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | KULBHUSHAN AGGARWAL L6 | MAMTA ENTERPRISES L2 | KEWAL SONS L7 | Ashoka Engineers L4 | PROACH ASSOCIATES BUILDERS & ENGINEERS L5 | ANIKET TRADERS L3 | Mahajan Construction Co L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar box any type and capacity including all control switches, fitting and fixtures from different location as directed by the Engr-in-Charge. | 16 | Each Job | 100 ₹1,600 Lowest | 200 ₹3,200 | 500 ₹8,000 | 200 ₹3,200 | 500 ₹8,000 | 500 ₹8,000 | 200 ₹3,200 |
| 2.00 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 System complete suitable for 3 phase 4 wire 415 Volt, 50 Hz. comprising of the following :- | 2 | Each Job | 1,62,000 ₹3,24,000 | 1,05,000 ₹2,10,000 | 99,000 ₹1,98,000 | 1,46,000 ₹2,92,000 | 1,18,000 ₹2,36,000 | 1,35,000 ₹2,70,000 | 85,000 ₹1,70,000 Lowest |
| 2.01a) Aluminium bus bar 600 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set (b) Incoming MCCB 400 Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos. (c) Outgoing MCCB 160 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA, with double break contacts with spreader and phase barrier complete all as directed. -1 Nos. (d) Outgoing MCCB 100 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA, with double break contacts with spreader and phase barrier complete all as directed. -2 Nos (e) Outgoing MCCB 63 Amps 4 pole 415 Volts AC with thermal magnetic 16 KA, with double break contacts with spreader and phase barrier complete all as directed. - 2 Nos f) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. g) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No h) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three. j) CT Coils of suitable ratio-01 Set. Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid Aluminium conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu. | ||||||||||
| 3.00 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93
system complete suitable for 3 phase 4 wire 415 Volt, 50 Hzcomprising of the following :- | 1 | Each Job | 1,20,000 ₹1,20,000 | 99,000 ₹99,000 | 99,000 ₹99,000 | 1,08,000 ₹1,08,000 | 99,000 ₹99,000 | 1,29,000 ₹1,29,000 | 71,678 ₹71,678 Lowest |
| 3.01a) Aluminium bus bar 300 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set (b) Incoming MCCB 200 Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos. (c) Outgoing MCCB 100 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA, with double break contacts with spreader and phase barrier complete all as directed. -1 Nos (d) Outgoing MCCB 63 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA, with double break contacts with spreader and phase barrier complete all as directed. -3 Nos (e) Outgoing MCB 32 Amps 2 pole AC with thermal magnetic 10 KA, with double break contacts with spreader and phase barrier complete all as directed. - 3 Nos f) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. g) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No h) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three. j) CT Coils of suitable ratio-01 Set. Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid Aluminium conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu. | ||||||||||
| 4.00 | Supply, Installation and Fixing LT 250A Bus Bar Feeder Pillar shall be OEM made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54 in accordance with IEC 60529 and Color code RAL 7032 completely dyed in mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal size should be not less than 590mm x 800mm x 220 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have shall be equipped with GRP handle lock with Manual outer locking and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Feeder Pillar with MCCB 250A FP 36KA - 1 No. Panel mounted on suitable MS Angle Stand and TPN Aluminium Bus-bar with Heat Shrinkable Sleeves of capacity 400 Amp, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed . | 4 | Each Job | 91,000 ₹3,64,000 | 59,000 ₹2,36,000 | 65,000 ₹2,60,000 | 46,500 ₹1,86,000 | 49,000 ₹1,96,000 | 30,000 ₹1,20,000 | 18,500 ₹74,000 Lowest |
| 5.00 | Supply, Installation and Fixing LT Bus Bar Feeder Pillar 300A shall be OEM made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54 in accordance with IEC 60529 and Color code RAL 7032 completely dyed in mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal size should be not less than 590mm x 800mm x 220 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. he Panel box shall have shall be equipped with GRP handle lock with Manual outer locking and the provision to insert various type of locking cylinders provided to avoid unauthorized access. . RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Feeder Pillar with MCCB 200A FP 25KA - 1 No. Panel mounted on suitable MS Angle Stand and copper Bus-bar with Heat Shrinkable Sleeves of capacity 300 Amp, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed . | 5 | Each Job | 81,000 ₹4,05,000 | 56,000 ₹2,80,000 | 60,000 ₹3,00,000 | 39,500 ₹1,97,500 | 65,000 ₹3,25,000 | 28,000 ₹1,40,000 | 18,000 ₹90,000 Lowest |
| 6.00 | Supply, Installation and Fixing LT Bus Bar Feeder Pillar 200A shall be OEM made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54 in accordance with IEC 60529 and Color code RAL 7032 completely dyed in mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal size should be not less than 590mm x 800mm x 220 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. he Panel box shall have shall be equipped with GRP handle lock with Manual outer locking and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Feeder Pillar with MCCB 160A FP 25KA - 1 No. Panel mounted on suitable MS Angle Stand and copper Bus-bar with Heat Shrinkable Sleeves of capacity 200 Amp, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed . | 12 | Each Job | 75,000 ₹9,00,000 | 37,000 ₹4,44,000 | 58,000 ₹6,96,000 | 34,000 ₹4,08,000 | 40,000 ₹4,80,000 | 27,000 ₹3,24,000 | 14,500 ₹1,74,000 Lowest |
| 7.00 | Supply, Installation and Fixing LT Bus Bar Feeder Pillar 100A shall be OEM made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54 in accordance with IEC 60529 and Color code RAL 7032 completely dyed in mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal size should be not less than 590mm x 800mm x 220 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. he Panel box shall have shall be equipped with GRP handle lock with Manual outer locking and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Feeder Pillar with MCCB 100A FP 16KA - 1 No. Panel mounted on suitable MS Angle Stand and Copper Bus-bar with Heat Shrinkable Sleeves of capacity 150 Amp, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed . | 4 | Each Job | 70,000 ₹2,80,000 | 39,000 ₹1,56,000 | 58,000 ₹2,32,000 | 28,500 ₹1,14,000 | 38,000 ₹1,52,000 | 25,000 ₹1,00,000 | 14,000 ₹56,000 Lowest |
| 8.00 | Supply & fixing GI tubing light grade 80 mm bore on poles, under floors, road crossing etc all as reqd at site and as directed by Eng-in-Charge | 48 | RM | 420 ₹20,160 | 600 ₹28,800 | 700 ₹33,600 | 500 ₹24,000 | 550 ₹26,400 | 400 ₹19,200 Lowest | 480 ₹23,040 |
Tender Value
₹67.7 L
EMD Value
₹1.3 L
Closing Date
25 Sept 2025, 6:00 pmClosed
K YASHVIR SINGH
HQ CWE AF JAMMU, AIR FORCE STATION JAMMU
SPECIAL REPAIR/REPLACEMENT OF EM EQUIPMENT HT/LT CABLES AND ALLIED WORKS AT AF STATION JAMMU UNDER GE (AF) JAMMU
2025_MES_724666_2
CA NO CWEAF-18/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAMMU
As per NIT and Tender Documents
8 documents required · 8 mandatory
₹1,000
GE AF Jammu
₹1.3 L
Yes
10 Apr 2026
4 Sept 2025
27 Sept 2025
4 Sept 2025
25 Sept 2025
11 Sept 2025
stage.html
html • 0.06 MB
technical_816405.pdf
techsummary_816405.pdf
finance_816405.pdf
BOQ Comparative Chart
xlsx
finsummary_816405.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDERDOCUMENT18CALL2ND.pdf
Tender Documents • 1.13 MB
BOQ_816405.xls
BOQ • 12.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .