| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC AT MQ 49 BODIYA BASTI KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | L1 | Accepted-AOC AOC | |
| 2 | Rejected-Technical MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Rejected as not L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected as not L1 |
Tender Value
Refer Docs
EMD Value
₹3,100
Closing Date
1 Nov 2022, 4:00 pmClosed
Project Engineer (EnM), Kathara Colliery
P.E. (EnM), Office of the PO, Kathara Colliery
Rewiring of internal electrical house wiring, changing of service wire and making of earth pit of DAV teachers quarters Qtr. No B/09, B/10, B/11, B/12 and 1B/68 quarter at staff colony of Kathara Colliery
2022_CCL_260086_1
PO(KTC)/PE(EnM) /E-Tender/2022-23/94
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
P.E. (EnM), Office of the PO, Kathara Colliery
As per NIT
5 documents required · 5 mandatory
₹3,100
31 Jan 2023
21 Oct 2022
2 Nov 2022
22 Oct 2022
1 Nov 2022
22 Oct 2022
22 Oct 2022 - 28 Oct 2022
Amount
Point wiring in PVC conduit, with piano type switch : wiring for light point/fan point/ exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/ Recessed PVC conduit, with piano type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVC insulated Copper conductor single core cable etc. As required. Group ’B’
Circuit sub main wiring in PVC conduit Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC conduit as required (2x1.5 Sq.mm+ 1x1.5 Sq.mm earth wire)
Circuit sub main wiring in PVC conduit: Wiring for c5ircuit/ sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC conduit as required(2x2.5 Sq.mm +1x2.5sqmm earth wire)
Supply and fixing following piono type switch/ socket on the existing switch box/cover including connections etc. as required a) 5/6 Amps. Switch
b) 5/6 Amps socket
c) 15/16 Amps. Switch
d) 15/16 Amps. Socket
Supply & fixing 5 Amps. To 32Amps. Rating 240/415V “C” curve, miniature circuit breaker suitable for Inductive load of following poles in the existing MCB DB complete with connections testing and Commissioning etc. as required.
Supplying & fixing following way, single pole and neutral, sheet steel MCB distribution board, 240V. on surface recess, complete with tined copper bus bar neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required (But without MCB/RCCB/isolator) (2+4way/6way double door)
Supplying & fixing stepped type electronic fan type regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required.
Earthing with G.I. earth plate 600mm x 600mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr. long etc. with charcoal/ coke and salt as required.
Twin core copper wire 2.5Sqmm 1100V
ICDP switch 32Ax240V
Labour charges
Total impact of GST for the purpose of CTC
M/S P. L. CONSTRUCTION
M/S YOGENDRA KUMAR RAWANI
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .