Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹34.1 L+₹31,140.63 (0.92%)Rejected-Finance MIRZAPUR MUMTAZ NAGAR AYODHYA AYODHYA UTTAR PRADESH 224001 | AYODHYA | UTTAR PRADESH | 224001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹39.0 L+₹5.2 L (15.4%)Rejected-Finance 0 DHANA TEJA BARARI DHANA TEJA MATHURA MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | L3 | Rejected-Finance L3 |
Tender Value
₹34.9 L
EMD Value
₹34,860
Closing Date
24 Mar 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer EWC Ayodhya
Office Of Superintending Engineer EWC Ayodhya
26/SE/EWC/AYO/2020-21
2021_MVVNL_570616_1
26/SE/EWC/AYO/2020-21
Open Tender
Electrical Works
Item Wise
90 days
amethi
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER ELECTRICITY WORKS CIRCLE
₹34,860
30 Mar 2021
19 Mar 2021
25 Mar 2021
19 Mar 2021
24 Mar 2021
19 Mar 2021
180 days
Amount
Safe Loading, Carriage and then safe unloading of the following material from Store Centres Under the jurisdiction of EEESD Ayodhya to dump site proper stacking.
STP 11.0 Mtr. Long
PCC 9.0 Mtr Long
33 KV Pin Insulator
V Type channel cross arm 100x50x60
M.S. Top Channel 125x65 mm 3200 mm
Cost of ACSR Dog Conductor
M.S. Angle 65x65x6 mm Bracing, 4300 mm
11 KV Disc insulator B & S Type
Stay wire 7/8 swg
33 KV Single Feeder Control pannel
C.T O/D 33 KV CTR 200/100/1-1A
M.S Angle for Guarding Angle 65x65x6 mm 3500 mm long
G.I. Wire 6 SWG for earthing
G.I. Wire 8 SWG for guarding
33 KV 3x300 sq mm XLPE Cable
33 KV Outdoor End Termination Kit for 3x300 sq mm XLPE Cable
34 KV S/T jointing Kit for 3x300 sq mm XLPE Cable
33 KV VCB 800 A,750 MVA
33 KV line Isolator
33 KV Lighting Arrestor Isolator
M.S. Channel 125x65 (for Structures )
M.S. Angle 75x75x6 (for Structures )
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Channel Cross Arm, as per norms. (Contractor shall provide 3 Nos. 33 KV G.I. Pin, necessary clamps, F-brackets, Nut - Bolts, Washers etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 no Channel Cross Arm, as per norms. (Contractor shall provide 3 Nos. 33 KV G.I. Pin, necessary clamps, F-brackets, Nut - Bolts, Washers etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm, 6 No. Disc. Fitting , Bracing angle 1 set., Disc insulator 24 No. and 3 No. Pin insulator as per norms. (Contractor shall provide 3 No G.I. Pin, E- Bracket 3 No., necessary clamps, Disc Fitting, Nut - Bolts etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectioal Double pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Top channel of 125x65x6 mm size 3200 mm, Disc Fitting 6 No., Bracing angle 1set. ,Disc insulator 24 No. and 3 No. Pin insulator as per norms. (Contractor shall provide 3 No. G.I. Pin, E- Bracket 3 No., necessary clamps, Disc Fitting, Nut - Bolts etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Four pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 4 No. Top channel of 125x65x6 mm size 3200 mm, Disc Fitting 6 No. Bracing angle 4 set, 24 No. 11 kv disc insulator B &S , Pin insulator 09 No. as per norms. (Contractor shall provide 9 No G.I. Pin, E- Bracket 3 No., necessary clamps, Disc Fitting, F-clamp , Nut - Bolts etc. )
Erection of single stud pole support on PCC Pole 9.0 Mtr long with fixing of necessary clamps and other accessories required for erection. (Contractor shall provide necessary clamps, Nut - Bolts, Washers etc)
Erection of single stud pole support on STP Pole 11 Mtr long with fixing of necessary clamps and other accessories required for erection. (Contractor shall provide necessary clamps, Nut - Bolts, Washers etc)
Fabrication & Erection of exposure Dead End Double pole on 11 Mtr. STP support with fitting of supply and mounting of necessary clamps and other accessories like 01 No. top channel 125x65x6 mm size 3200 mm, Bracing Angle 1 set, 11 kv disc insulator 12 No. and 3 No. disc fitting as per RESPO Norms. (Contractor shall provide 03 No. Disc fitting ,Neccessary clamps ,Nuts & Bolts etc.)
Cradle Guarding of 33 KV line at road crossing, 11 KV line crossing, canal/telephone line crossing by fixing Guarding Angle 65x65x6 mm, 3500 mm at double pole and 2600 mm long at single pole by stringing and sagging of 3 No. G.I.wire with lacing and tightening with mounting. (Contractor shall provide Necessary clamps for fitting of guarding angle and 3 No. Eye Bolt 12x110 mm etc.)
Nozeling and grouting of stay at sectional pole and extra stay sets at angle locations (All the civil material and stay set, stay clamp will be arranged by the contractor except stay wire)
Earthing of Pole STP/PCC by 6 SWG Wire by providing and fixing of 20 mm dia' earthing rod 2.550 Mtr. long as per norms complete in all respect. (Contractor shall provide all the material Like Earthing rod, 6 swg wire, Earthing clamps and nut & bolt etc.)
Stringing, sagging, binding and Jumpering of ACSR Dog conductor. 3 Phase of 33 KV Line including fixing, mounting of P.G.clamp suitable for Dog Conductor at sectional point. (Contractor shall provide necessary PG clamps etc)
Line Isolator Structure Fabrication of isolator structures 3.5 mtr in height as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.9 x 0.3 Mtr providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with runner of isolator in proper allingment level and plumb. Both plinths of the Isolator structure shall be properly finished with smoothening of edges and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs (All the civil & other materials will be supplied by the contractor Except steel).
Laying & Dressing of 3x300 sq. mm XLPE Cable underground Double Circuit. Laying of double circuit 3x300 sq .mm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required materials, as 1st class Bricks, Stone slabs and fine sand. Providing 150 mm fine sand cusion beneath, and 150 mm sand cusion above the cable. The cable shall be duly protected by Bricks, sand and stone slab. The inter axial spacing between two cables should be in between 0.25 to 0.04 M. After laying the cable refilling and ramming of the left out soil,closing the trench and leveling.
Installation of Heat Shrinkable Type cable jointing kits of following types/sizes for 33 XLPE Cable.
(a) Fixing of 33 KV 3x300 sq. mm Straight Through joints. (jointing kit supplied by dept.)
(b) Fixing of 33 KV 3x300 sq. mm Outdoor End Terminations (jointing kit supplied by dept.)
Lightening Arrestor Structure Fabrication & Erection of Lightening Arrestor as per drawing No. RES 39 Digging of 2 No. Pits of size 1.075 x 0.3 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC (cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr x 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allingment level and plumb. Both plinths of the structure shall be properly finished with champering of edges and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs through connect L.A as per norms (All civil & other materials will be supplied by the contractor Except steel as channel & angle).
Installation of Line Isolators Assembling and installation of line isolator on the Isolator structure, adjusting of opening mechanism in proper alignment so as to ensured smooth operation of the same. In case of line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
Installation of Lightening Arrestors Assembling and installation/ mounting of 03 Nos.Lightening Arrestors on the L.A. structure complete and making earth connection ( Separate ) and line connections for L.A. The work includes fabrication for proper fixing if required.
Cable stand Structure Fabrication & erection of 33 KV Cable Stand made of 02 No. M.S chanel 125x65x6 mm 3 Mtr. Jointed to each other by M.S Channel horizontally and also jointed to each other by means of 05 No. M.S Strip 50x6 mm of size 150 mm long each by welding at actual distance interval as per norms. And grouting in block of 300x300x700 completely providing 02 no. cable clamps also and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs. (All the materials will be arranged by the contractor such that clamps nut bolts and civil materials except M.S channel.)
Fencing of switchyard Fabrication of switchyard fencing with wire mesh 10 SWG (37x50 mm) as per drawing along with fabrication of one no. gate made of M.S Angle, M.S Channel, M.S Flat togetherwith locking arrangement, its installation including the cost of civil materials, angle 50x50x6 mm.
Toe Wall boundry Construction of Toe wall around the outdoor switchyard of the S/S of size 0.75 Mt.At Base and 0.23 Mt. at top as per RESPO norms by 1st class bricks in the ratio 1:6, Base concreting of the wall to be done in ratio 1:6:12 and plaster 12 mm thick in ratio 1:4.
Plinth For VCB Construction of plinth of size (2.0x1.5x0.9 (Mtr.) suitable for errection of super structure for 33 kv VCB including grouting of Anchor bolts in proper allignment and level. Scope of works includes excavation of foundation base concreting in CC 1:6:12 (cement,fine sand and bricks ballast) 1st class bricks work in cement mortor of ratio 1:4 CC in ratio 1:4:8 and RCC works in ratio 1:2:4 (cement, coarse sand and stone grit of 20 mm gauge) as per drawing
Installation of 33 KV VCB Installation of 33 KV 750 MVA 800 Amp VCB on 33 KV VCB structure along with earthing by G.I. strip 50x6 mm size with main earth mat of Switchyards complete in all respect including commissioning & testing.
Fabrication & Errection of CT Structure & Its Installation Fabrication of CT Structure as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.3 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr X 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allignment level and plumb. Plinths of all the structure shall be properly finished with champering of edges etc. Installation of 3 Nos CTs of ratio 200/100/1A on the CTs structure. The work includes fabrication for proper fixing if required and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs. (All the material will be supplied by the contractor except Steel Section and 03 No. CT)
Construction of control cable trench of 300 mm wide and 300 mm deep with MS strip at an interval of 0.5 mtr. With brick work 1:4:8 in foundation 12 mm thick plaster of 1:4 cement coarse sand for finishing along with MS Angle running on both edges of the trench. (All the material will be supplied by the contractor)
Supply & Laying of 4x2.5 sq.mm. Sq. control cable from power T/F to controle board in the cable trench/ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
Supply & Laying of 2x2.5 sq.mm. Sq. control cable from power T/F to controle board in the Cable trench/ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
Construction of trench cover of 600 mm long and 75 mm thick for cable trench Including cost of material, labour and T&P. (All the material will be supplied by the contractor)
High Pressure testing to which 33 KV Line & cable to be stand for duration of 5 minutes after completion of Laying, Stringing, sagging, binding and Jumpering of ACSR Dog conductor. ( Testing equipment will be arranged by the contractor)
Hoisting of 33 KV Cable on existing/erected support with provision of MS Pipe 150 mm dia 3 mtr long suitable for 3x300 sq mm cable fixing of proper support and its clamping, providing long barral lugs 6 nos and P.G. Clamps & "Y" shape jumpering properly and 02 nos. supporting angle 65X65X6, 2240 mm long and making connection including supply of jumpering cable ,mounting clamps as per RESSPO Norms. (All material will be supplied by the contractor like M.S Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65X65X6, 2240 mm and jumpering cable suitable for 33 KV jumper).
Painting of All Structures with one coat of ready mixed primer and 2 coats of AL.Paint of good quality including cost of material, Labour and T&P complete in all respect. (Contractor shall provide all materials)
Grouting of following structure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
11 Mtr ST Poles
9.0 Mtr PCC pole
Supply and fixing of a stone pad of size 300x300x75 mm at PCC/STP Bottom of the pit ( Contractor shall provide all materials)
Fabrication, Erection and grouting of route marker and marking 33 KV line by painting after grooving on the stone. (Contractor shall provide all materials)
Installation of 33 KV Single feeder control pannel Shifting carefully and safely installaltion 33 KV Single feeder control pannel in control room including grouting ,commissioning and testing control circuit. Its earthing by 35x6 mm G.I strip as per procedure with earth mat also.
Fixing of barbed wire on pole Supply and fixing of barbed wire on the pole above 2750 mm ground level. Barbed wire wrapped for a distance of 0.9 mtr. with a pitch of 13.mm at a height. (All materials supplied by the contractor)
Fixing of Danger board . Supply and fitting of Danger board of size 250x200x2 mm 3650 mm above ground level as per Respo norms.RESPO Drawing No-55
Painting of poles Painting of 11 Mtr S.T. pole with one coat of red oxide, two coats of enamel paint ISI mark. (All required material will be supplied by the contractor)
Hindustan Electric Work
M/s S.K. Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .