Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹95.0 L+₹9.9 L (11.6%)Rejected-Finance AT POST ARANGAON MEHERABAD TAL DIST AHMEDNAGAR PIN 414006 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414006 | L2 | Rejected-Finance Rate higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
27 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL N K SAH
CWE AF LOHEGAON
ADDN ALTN OF BLDG NO P04 P 05 AND P 06 AT AF STN PUNE UNDER GE AF LOHEGAON
2021_MES_460589_1
81828/E8
Open Tender
Miscellaneous Works
Works
365 days
GE AF LOHEGAON
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE AF LOHEGAON
₹1.7 L
Yes
5 Oct 2021
16 Jul 2021
6 Sept 2021
16 Jul 2021
27 Aug 2021
14 Aug 2021
90 days
Amount
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed by Engr-in- Charge.
M&L for cement concrete M-40 (Design Mix) using 20mm graded aggregate in pavement / hard standing with minimum cement content of 400 kg/cum, thickness of concrete 25cm or less all as specified and directed by Engineer -in- Charge.
M&L for forming contraction ( Dummy) joints, 65mm deep x 10mm wide filled with sealing compound Grade A complete all as specified and directed by Engr - in- Charge.
M&L for providing 75 mm thick PCC (1:3:6) type C2 using 40 mm graded aggregate as Path/Plinth protection finished the surface even & smooth with out using extra cement complete all as specified and directed by Engineer in charge.
M&L for Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm screed bed or bedding layer for floor finishes in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for Double Chaged Vitrified tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm screed bed or bedding layer for floor finishes in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L for 25 MM thick cement concrete type B-1, 1:2:4 ( 20 mm graded aggregate) as in sub base to flooring/path etc, complete all as specified and as directed by Engr-in- Charge.
M&L for 20mm thick Granite (of any colour) stone in cooking platforms/ flooring set and jointed in neat cement slurry including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over 20 mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed by Engr-in- Charge.
Taking down cement or cement lime plaster on brick or stone walls, etc including racking out joints hatching for key, scrubbing down with water etc complete all as specified and as directed by Engr-in- Charge.
M&L for joint free Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in colour cement to match complete all as specified and as directed by Engr-in- Charge.
M&L for 20 mm thick Granite (of any colour) stone machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed by Engr-in- Charge.
M&L for 10mm thick rendering in CM 1:6 on brick or concrete surface as backing coat complete all as specified and directed by Engr-in- Charge.
M&L for 10 mm thick rendering in CM 1:4 on broken chajjas / facia / walls /ceilings etc, area n. exc 3 sqm each patch (in repairs) , includings finishing to match with existing surfaces without using extra cement complete all as specified and directed by Engr-in- Charge.
M&L for 15 mm thick rendering in cement morta 1:6 on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in- Charge.
M&L for applying two coats of oil bound distemper over a coat of primer,over 1mm thick wall care putty on walls including preparation of new or previously untreated surfaces complete all specified and directed by Engr-in- Charge.
M&L for applying two coats of Cement Base Paint over a coat of alkali resistane primer on walls complete all as specified and directed by Engr-in- Charge.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed by Engr-in- Charge.
Demolition of brick work / stone built in cement mortar complete all as specified and directed by Engr-in- Charge.
M&L for brick work with sub-class 'B' bricks, straight or curved on plain to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L for 10 mm thick rendering in cement morta 1:6 on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge.
M&L for Reinforced cement concrete type B1 1:2:4 ( nominal mix) using 20mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelvs concrete 25cm or less all as specified and directed by Engineer -in- Charge.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc complete all as specified and directed by Engineer in charge.
M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floors and roofs not exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10 cm but not 20 cm wide complete all as specified and directed by Engineer in charge.
M & L for MS TMT bars 10mm dia and over as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer in charge.
M & L for MS TMT bars 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders or securing with clips etc complete all as specified and directed by Engineer in charge.
M&L for water proofing treatment with APP based polymeric membrane over 15mm thick plaster on roof with the following courses of treatment :- (a) Complete removal of existing treatment, cleaning & washing the concrete /tiles surface by using wire brush including junction of parapet etc. (b) M&L 15mm thick cement plaster in CM 1:4 using water proofing liquid as per manufacturer instructions over neat cement slurry @ 3kg/Sqm on roof surface. Note: Water proofing liquid /compound will be measured & paid separately. (c) Applying bituminous primer (IS 3384) @ 0.160 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (d) M&L for APP based polymeric membrane minimum weighing 3 kg/Sqm and minimum 3mm thick reinforcement with polyster non woven fabric (wt reinforcement not less than 150gms/sqm) laid in primed surfaced application including preparation and applying two coats of Heat resisting Aluminium paint over APP membrane complete all as specified and directed.
M&L for rendering in two layers on external surfaces first layer 10mm thick in CM 1:6 on fair faces of brick/PCC block or concrete surfaces and second layer ( setting coat / finishing) 5mm thick in CM 1:4 with approved water proofing compound finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge. (Note:- WPC shall be measured and paid seperately)
M&L for 5mm thick rendering in CM 1:4 on ceiling surface complete all as specified and directed by Engr-in- Charge.
Taking down Shutters of any description exc 1 sq. m and not exc 2 sq. m each complete all as specified and as directed by Engr-in- Charge.
Taking down Shutters of any description not exc 1 sq. m each complete all as specified and directed by Engr-in- Charge.
Taking down shutters of size exc 1 sqm and n exc 2 sqm each and refixing in the same opening including necessary adjustment after laying of floor tiles complete all as specified and directed by Engr-in-charge.
S & F 30 mm thick flush shutter water proof BWR grade solid core construction with block board core and ply wood face panel commercial type both sides complete all as specified and as directed by Engr -in - Charge.
S&F for 35mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chowkats complete complete all as specified and as directed by Engr-in-charge.
S&F for 30mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chowkats complete complete all as specified and directed by Engr-in-charge.
Taking down Chowkhats or frames without taking of shutters exc 1.5 sq. m but not exc 4 sq. m each complete all as specified and as directed by Engr-in- Charge.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing complete all as specified and directed by Engr-in- Charge.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of ms tubes for top &bottem rails, ms frame shall be covered with heat moulded plain colour PVC 'C' channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheetfor top rail ,lock rail, &bottem rail, on either side & as gap insert for top rail , panneling of plain colour pvc sheet to be fitted in the ms frame welded /sealed to the stiles & rails with suitable pvc sheet beading, & jointed together with solvent cement suppling & fixing in the frame at site complete all as specified and directed by Engr-in-Charge.
S&F mild steel 100 mm long butt hinges, medium weight cold rolled complete all as specified and directed by Engineer in charge.
S&F 150 mm long aluminum anodised barrel tower bolts of extruded section of size complete all as specified and directed by Engineer in charge.
S&F 125 mm extruded aluminum alloy handles, cast type, anodized complete all as specified and directed by Engineer in charge.
S&F in repairs Powder Coated aluminium frame (any colour) for partitions, doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.(sealing of window/door frames with sillicon gel to avoid rain water entry) complete all as specified and as directed by Engr-in- Charge.
S&F in repairs for Galvanised mild steel wire cloth of 0.56 mm nominal dia of wire & and average width of aperture 1.18 mm fixed with Aluminium beeds for bird proofing of ventillators complete all as specified and directed by Engineer in charge.
S & F in repairs 3mm thick sheet glass glazing with oil putty or wooden beads in squares n. exc 0.5 sqm in each pane complete all as specified and directed by Engineer in charge.
S&F sheet frosted glass 5.5 mm thick and glazing with rubber beading in Square not exc 0.5 Sq.m in each pane complete all as specified and directed by Engr-in- Charge.
M&L MS Framed work of Fe-410- W (GdeE-250) in repairs as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer in charge.
S&F in repairs 300 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer in charge.
M&L for Preparation of new steel surface of any description over 10 Cm in width or girth, not otherwise described applying two coats of synthetic enamel paints over a coat of red oxide zinc primer complete all as specified and directed by Engineer in charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed by Engineer in charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting (PPGL) 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws etc complete all as specified and directed by Engineer in charge.
S&F 0.80mm thick plain Galvansied mild steel sheeting with 275 gm/sqm Zinc coating as in ridge, hip, valley gutters, drip and straight flashing fixed with coach screws & washer in roof etc complete all as specified and directed by Engineer in charge.
S&F wind ties for roof including securing bolts and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer in charge.
S&F in repairs 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two orrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed by Engr-in- Charge..
S & F Mild steel rolled sections as in Columns, Vertical posts etc; fixed with angle cleats or other connecting plates Fe-410- W (Gde E-250) qualityB complete all as specified and directed by Engr-in- Charge.
S&F Mild steel roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe-410 W(Gde E-250) complete all as specified and directed by Engr-in- Charge..
M&L for complete removal of existing treatment and applying two coats of Cement Base Paint over a coat of alkali resistane primer on walls complete all as specified and directed by Engr-in- Charge.
M&L for applying two coats of oil bound distemper over a coat of primer, on walls including preparation of new or previously untreated surfaces complete all specified and directed by Engr-in- Charge.
M&L for applying three coats of white wash including preparation of new or previously untreated on ceilings surfaces complete all specified and directed by Engr-in- Charge.
M&L for running welding in repairs of metal exceeding 9mm but not exc. 20mm thickness complete all specified and directed by Engr-in- Charge.
M&L for precast cement concrete block masnory with soild blocks, exc 10 cm in width with PCC type C1, 1:3:6 ( using 20mm graded stone aggregate) and set in CM (1:6) complete all as specified and directed by Engr - in- Charge.
Demolition of Stone slabs and tiles laid, bedded, pointed in ay mortar of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer in charge.
Machine cut cudappah stone slab 20-25mm thick over 20mm thick cement screed in CM 1:4, base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer in charge.
S&F vitreous china squatting pan of water closet (Orrisa pattern) size 580mm x 440 mm white with integral foot rests complete connection to drain ( outgoing pipe) and to flushing pipe of 32 mm dia and syphonage pipe etc and making good the floor with provn of concrete bedding in repair complete all as specified and as directed by Engr-in- Charge..
S&F PVC valve less syphonic action type, flushing cistern 10 ltrs capacity,low level white with inlet, ball valve float and handle including brackets including 32mm dia PVC flush pipe for low level cistern including all joints fixed in repair complete all as specified and directed by Engr-in- Charge.
S&F in repairs Vitreous China urinals, bowl type min size 420 x 395 x 635mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engr-in- Charge.
S&F, as in repair, vitreous china wash basin, white flat back size 630x 450 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand alongwith 32mm PVC waste pipe and brass chromium plated waste coupling complete all as specified and directed by Engr-in- Charge..
Supply only, 15 mm bore pillar taps fancy type (long neck) cast copper alloy with capstan heads chromium plated screwed down high pressure with or without letter hot or cold with long screwed and shanks and fly nuts screwed for iron pipes complete all as specified and directed by Engineer in charge.
S&F for 15 mm bore stop valves chromium plated fancy type screwed down high pressure with crutch or batterfly handle screwed both ends for iron pipes or for union fixed in repair complete all as specified and as directed by Engr-in- Charge..
S&F in repairs for 15 mm bore CP angle stop valves of high pressure screwed for iron pipe and fixed complete all as specified and directed by Engineer in charge.as specified.
S&F in repairs for 15 mm bore CP push tap any colour high pressure screwed for iron pipe and fixed complete all as specified and directed by Engineer in charge.
S&F for bib tap 15 mm bore of fancy chromioum plated with long shank & cup , screwed down high pressure with crutch or butterfly, screwed both ends for iron pipe or for brass ferrule fixed in repair complete all as specified and as directed by Engr-in- Charge.
S&F 600mm x 450mm bevelled edge mirror with border, 5mm thick glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with cromium plated brass screws and cup washers complete all as specified and as directed by Engr-in- Charge.
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer in charge.
S&F Chromium plated towel rod 600 mm long fixed with and including chromium plated brass screws complete all as specified and directed by Engineer in charge.
S&F LPDE waste pipes of 32mm bore pressure rating 6 Kgf/Sqcm for wash hand basin, all as specified complete all as specified and directed by Engineer in charge.
S&F PVC connection 15mm dia sizes with PTMT nuts of length 450 mm complete all as specified and directed by Engineer in charge.
S&F Chromium plated Liquid soap container fixed with and including Chromium plated brass screws on walls complete all as specified and directed by Engineer in charge.
S&F in repairs High density polythene pipe(HDPE), 50 mm bore of pipes of pressure rating 6 Kgf /Sq cm fixed complete to wall or laid in tranches or floors etc (50 mm bore) incl all fittings complete all as specified and directed by Engineer in charge.
Demolition or breaking up drain pipe ( salt glazed ware, AC, CI, PVC or reinforcement concrete) of any dia etc complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) pipes 75mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) pipes 110mm dia in any length with rubber ring joints fixed to walls/trenches/floors etc complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) bend 110mm dia with access door bends complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) bend 75mm dia with access door bends complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) junction double, (Double T) equal or unequal 110mm Dia with access door bends complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) junction double, (Double T) equal or unequal 75mm Dia with access door bends complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) branch piece double, (Double Y) equal or unequal 110mm Dia with access door bends complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) branch piece double, (Double Y) equal or unequal 75mm Dia with access door bends complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) gully trap 110 mm dia setting and jointing with solvent cement concrete and providing connection upto 1st manhole with PVC pipe complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) P traps in bore 110 mm dia complete all as specified and directed by Engineer in charge.as specified.
S&F grating 150mm dia of Chromium plated for wash basin fixed in repairs complete all as specified and directed by Engineer in charge.as specified.
S&F Mild steel Framed work such as grills, gratings etc with ends of bars shouldered and /or riveted, or forget into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings cable trench cover & water tanks and similar work conforming to Fe 290-Gde-E-165 complete all as specified and as directed by Engr-in- Charge.
S&F in repairs kitchen sinks with drainage board made of stainless steel 1mm thick with plugs, washers and wastes including bedding in CM 1:3 to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engr-in- Charge.
M& L for 2 mm thick epoxy polyurethane flooring over one coat of primer and also rate includes the roughing and grinding of top surface of existing flooring and cleaning and making good for primer and sealant in crack filling complete all as specified and as directed by Engr-in- Charge.
Dismantling of wall and ceiling board ( fibre, pulp, insulation etc) as in ceiling and lining of any gauge or any thickness including cover fillets complete all as specified and directed by Engineer in charge.
M&L for 9mm thick prepainted PU coated Gypsum Board (600 x600mm ) suspended false ceiling including GI powder coated grid work using 32.5mm x 23.5mm x 1.5mm thick main tee 25 mm x 23.5 mm x 1.28 mm cross tee and 25mm x23.5mm x 1.2mm angle fixed to wall for false ceiling including necessary supporting hanger with 6mm dia GI wire and 'J' bolts washer nuts for securing frame work to ceiling, suspended @ 120 cm C/C both ways, size of grid shall be 605 mm x605mm complete all as per manufacture instruction as specified and directed by Engineer in charge.
Taking down chowkats with shutters of any description not exc 1.50 sqm each and removing to or from store complete all as specified and directed by Engr-in-charge.
S&F Powder Coated (any colour) aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws including floor door closer mechanism etc. complete all as specified and as directed by Engr-in- Charge.
S&F Powder Coated (any colour) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.complete all as specified and as directed by Engr-in- Charge.
S&F Powder Coated (any colour) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed by Engr-in- Charge.
S & F in galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width or aperture 1.40mm and fixed with tinned tackles or galvanished wire complete all as specified and as directed by Engr-in- Charge.
S&F in repairs 3mm thick Figured glass, pin head type and glazing with oil putty /or wooden beads in squares n exc 0.50 sq. m in each pane complete all as specified and directed by Engineer in charge.
S&F 5.5mm thick sheet glass glazing with oil putty or wooden/ rubber beads in squares n. exc 0.50 sqm in each pane complete all as specified and directed by Engineer in charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth for foundations, etc or for shafts, wells, manholes, laying of cable etc and getting out in soft /losse soil complete all as specified and directed by Engr-in- Charge.
ditto all as per item No. 102 above but hard / dense soil complete all as specified and directed by Engr-in- Charge.
M&L 300 mm bore RCC pipes class NP-2 laid and jointed complete with collars with new PCC bed complete all as specified and directed by Engr-in-Charge. (Note :- PCC bed shall be measured and paid seperately)
M&L for PCC 1:4:8 type D2 using 40mm graded agg to 300mm bore drain pipes incl packing under and haunching against the sides after they are laid & tested complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm with soil obtained from excavation complete all as specified and as directed by Engr-in- Charge.
Removing excavated soil exc.50.0 mtr but not exceeding 250 mtr and depositing soil where directed at level not exceeding 1.5 mtr above the starting point etc complete all as specified and directed by Engineer in charge.
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for making good the desturbed floor/wall /duct surface or any foundation work as required on site etc complete all as specified and as directed by Engr-in- Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred / stopped ends etc complete all as specified and directed by Engr-in- Charge.
M&L for 10mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces, drain walls & finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge.
M&L precast cement concrete (1:2:4), type B1 using 20 mm graded crushed stone aggregate as in cover slab for Manhole and setting in cement mortar 1:4 including necessary form work complete all as specified and directed by Engineer in charge.
M&L 150mm bore RCC pipes class NP-2 laid and jointed complete with collars with new PCC bed complete all as specified and as directed by Engr-in-Charge. (Note :- PCC bed shall be measured and paid seperately)
M&L for PCC 1:4:8 type D2 using 40mm graded agg to 150mm bore drain pipes incl packing under and haunching against the sides after they are laid & tested complete all as specified and as directed by Engr-in-Charge.
Cutting into existing manholes for connecting nw drains and rendering, cutting out branch channel and making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as 150 mm Bore( Internal diameter ) complete all as specified and as directed by Engr-in- Charge.
S&F for self contained wind power design industrial turbo ventillator 60 cm dia including ball bearing etc on existing roof complete all as per manufacturer instructions with specified and directed by Engr-in- Charge.
Taking up or down 15mm dia GI steel water tubing and connections, including cleaning and refixing the in new or old positions complete all as specified and directed by Engr -in- Charge.
Taking up or down 20mm dia GI steel water tubing and connections, including cleaning and refixing the in new or old positions complete all as specified and directed by Engr -in- Charge.
Taking down the sub main wiring of any dia / sqmm on teak wood batten / PVC conduit GI earth wire complete all as specified and as directed by Engr-in- Charge.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MCB distribution boards SP & TPN with porcelain cutouts etc complete all as specified and as directed by Engr-in- Charge.
Taking down existing tube light fittings and disconnecting connection cable ends complete all as specified and as directed by Engr-in- Charge.
M&L for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and directed by Engr-in- Charge of the following items:-
One light point controlled by one switch.
One Exhaust/Wall mounted /Ceiling point controlled by one regulator/switch
M&L for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping 25mm size with all fittings/fixture etc fixed wall and open recessed type Plastic switch board) made of robust Synthetic material Fire Proof, Anti corrosive & shock proof ISI Marked complete for housing one 15 A Switch / sockets complete all as specified and directed by Engr-in- Charge.
M&L for wiring complete with 2.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 V grade conforming to IS 694 drawn through steel ERW conduit of 25mm ( external) flame proof, heavy grade ISI marked including necessary conduit accessories surface on wall, ceiling etc including sunken type pressed steel terminal boxes with phinolic laminated sheet of approved shade 3mm thick including 1.5mm PVC insulated flame retardent copper conductor as in continous earth wire for One flame proof light point / Fan point controlled by one way metal clad switch complete all as specified and directed by Engr-in- Charge.
M&L for sub main wiring with two runs of single core 2.5 Sq mm FRLS PVC insulated unsheathed multi straned copper conductor 1100 V grade with colour code and one run of 1.5 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable for continous earthing complete in & including PVC casing & caping with all fitting & fixtures complete all as specified and directed by Engr- In- Charge. Note:- Two runs of 2.5Sqmm & one run of 1.5 sqmm copper cable including PVC casing & caping shall be measured and paid as one length.
M&L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 Sq mm ( 22 / 0.3 mm ) single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping all as directed. Note :Two runs of 4.0 Sqmm copper cable, including PVC casing & capping one run of earth wire of 2.5 Sqmm copper cable shall be measured & paid as one length.) complete all as specified and directed by Engr-in- Charge.
M&L for sub main wiring with two runs of single core 6.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures complee all as specified and directed by Engineer-in-charge. (Note:- Two runs of 6.0 & one run of 4.0 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
S&F switch piano flush type 5 A one way complete all as specified and directed by Engr-in- Charge.
S&F switch socket combination multipurpose 3 pin 6/16 Amps complete all as specified and directed by Engr-in- Charge.
S&F ceiling rose surface type bakelite/PVC three terminal 65x50mm complete all as specified and directed by Engr-in- Charge.
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engr-in- Charge.
S&F flame proof flurecent tube light fitting 1 x 36 watt of type FLP - WP made of aluminium alloy LM6 with electronic ballast bipin holders connetor block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable complete all as specified and directed by Engr-in- Charge.
S&F flame proof single phase exhaust fan 305 mm 12" 230 volts, 1440 RPM, fitted with FLP motor 0.25 HP including louver and making hole in existing wall for fixing the fan making good the disturbed surface complete all as specified and directed by Engr-in- Charge.
Taking down the existing highbay light fitting and Supply & fix (in Repalcement) energy saving and environmental friendly robost IP 65 protected LED midbay with PDC housing suitable for ceiling (Surface/Suspended) mount 150 Watt with system efficiency not less than 145 lm/W incl electronic driver fixed in ceiling/ suspended incl making all nacessary arrangement for fixing/hanging and anchering as required on site making electrical connections complete all as specified and directed by Engr-in-Charge.
S&F Air Circulator fans 230 volts single phase oscillating 750 mm sweep suitable for wall mounting complete all as specified and directed by Engr-in-Charge.
S & F industrial wall mounted fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting complete all as specified and directed by Engr-in- Charge.
S&F fans ceiling complete with electronic type regulator and accessories 230 V , 1400 mm sweep complete all as specified and directed by Engr-in- Charge.
S&F wall mounted fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed by Engr-in- Charge.
S&F padestal fans 230 volts single phase oscillating 500mm sweep suitable for wall mounting complete all as specified and directed by Engr-in- Charge.
S&F high quality indoor Surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete all as specified and directed by Engr-in- Charge.
S&F Energy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connections as directed complete all as specified and directed by Engr-in- Charge.
S&F heavy duty exhaust fan 450mm sweep, 1400 RPM, turbo force SP, 230 volts complete all as specified and directed by Engr-in- Charge.
S&F Vertical double door Distribution board TPN 4 way 200 A rated busbar suitable for incoming MCCB and outgoing MCB's including MCCB 100A 4 pole 18 KA-01 Nos complete all as specified and directed by Engr-in- Charge.
S&F sheet metal enclosure MCB DB double door SPN 08 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed by Engr-in- Charge.
S&F sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed by Engr-in- Charge.
S&F sheet metal enclosure MCB DB double door SPN 16 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed by Engr-in- Charge.
S&F sheet metal enclosure MCB DB double door SPN 04 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed by Engr-in- Charge.
S&F MCB SPN 40 Amp, 230 volt 'C' series complete all specified and as directed by Engr-in- Charge.
S&F MCB SP 240 volt 6 to 32 A 'C' series complete all as specified and directed by Engr-in- Charge.
Supply, laying, jointing, testing and commissioning of LT under ground cable 25 Sq mm 4 core, 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles/and steel structure etc as required on site with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified and directed by Engr-in- Charge of the following sizes:-
25 Sqmm x 4 core
16 Sqmm x 4 core
M&L for crushed stone sand cushioning to under ground cable provided with a layer 8 cm before and 10 cm after laying and stretching jointing and testing the cable complete all as specified and directed by Engr-in- Charge.
S&F un reinforced precast concrete cable cover class 1 flat of size250 mm x 150mm x 40mm for cable protection complete all as specified and directed by Engr-in- Charge.
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for making good the desturbed floor/wall /duct surface or any foundation work as required on site etc complete all as specified and directed by Engr-in- Charge.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate for making good the disturbed floor/wall /duct surface or any foundation work as required on site etc complete all as specified and as directed by Engr-in- Charge.
S&F 40mm dia GI steel water tubing medium grade ISI marked laid in trenches or fixed to walls and ceilings or laid in floors, raising height of existing air termination rods with and including making all necessary fixing arrangement on roof/wall of bldg anchoring etc as required on site and all fittings such as bends, elbows,tees, short pieces etc complete all as specified and directed by Engr -in- Charge.
S&F Hot Dip galvanised perforated cable tray and cover of width 100 mm, depth 25 mm and thickness (16 SWG) fabricated from GI sheet GI coupler plate and hardware and all nacessary Vertical or horizontal fixing arrangements as required on site complete all as specified and directed by Engr-in- Charge.
Taking out carefully by disconnecting Electrical / data cables connections from existing panels/DBs of old UG cables or wires of any size and capacity with MS/GI pipes /PVC conduit pipes of any size from existing wall after unscrewing screws, removing clamps and refixing the same properly for good layout on wall / floor by using new clamps and screws of suitable size as requred on site or as to fit in cable trays size and re-connecting all connections properly complete all as specified and directed by Engr-in- Charge.
Taking down ceiling/wall/air circulator /padestal fans any type and size from the site by disconnecting all electrical connection ,and cleaning , rubbing by emery paper , servicing , oiling , greasing incl replacing small parts like bush/bearing etc and applying two coat spray painting complete and refixng on site making all nacessary connecrtion and testing for smooth functioning complete all as specified and directed by Engr-in- Charge.
M&L for spray painting of indoor/outdoor panels any size / any type with two coats of synthetic enamel paint after rubbing with emery paper and one coat of metal primer including cleaning of oils, dust and rust partical of the exisiting fitted matels parts complete including minor repair and welding/ brazing of hinges etc complete all as specified and directed by Engineer-in-Charge.
S&F aluminium strips 25x3 mm on porcelin insulator 15 BMD type 'T' placed not more than 50 cm apart complete all as specified and directed by Engr-in- Charge. ( Note : Porcelain insulators with nuts bolts and Acrews will measured and paid separatly under relavent items)
S&F DMC porcelain insulators of size 20x3 mm T type with nut bolts / screws for fixing of copper/aluminium/GI strips on walls/Roof etc complete all as specified and as directed by Engr-in- Charge.
S&F test point terminal block made out of gun metal or phosphorous bronze size 150x150x75 mm depth drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthetic enamel paint complete all as specified and directed by Engr-in- Charge.
S& F air termination rod single pointed aluminium 12 mm dia & 300 mm long complete all as specified and as directed by Engr-in- Charge.
S&F GI earth strips 32 mm x 6 mm fixed on procelane insulator fixed on wall / roof using cadmium plated Nuts, bolts, washers,screw or laid in tranches complete all as specified and as directed by Engr-in- Charge.
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified and directed by Engr-in- Charge. Note:- (i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost deemed to be quoted rate by Contractor. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum. (iv) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Shifting of Distribution boxes 4/6/8 way from one location to another location as required on site with necessary connection fixing arrangement cutting in walls incl making good the disturbed surface as existing complete all as specified and directed by Engr-in-Charge.
Supply , Installation, Testing and Commissioning of LT Panel indoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following complete all as specified and ditrected by Engr- In- Charge:- Note:- (a) Copper bus bar 200 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b) MCCB FP 125 Amps 16 KA - 01 No for main in coming (c) MCB 40 Amps TPN, 10 KA - 04 Nos (d) MCB 40 Amps SPN, 10 KA - 06 Nos
Supply , Installation, Testing and Commissioning of LT Panel indoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following complete all as specified and ditrected by Engr- In- Charge:- Note:- (a) Copper bus bar 150 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conical type at a maximum interval of 500 mm- 01 Set. (b) MCCB FP 100 Amps 16 KA - 01 No for main in coming (c) MCCB 63 Amps TP, 16 KA - 01 No (d) MCCB 32 Amps TP, 10 KA - 03 Nos
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to including galvanised GI wire 4mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip wire 4mm with GI protection pipe of 20 mm medium grade 7.5 meter long, etc complete all as specified and directed by Engr-in- Charge. Note:- (i) Vendors are bound to get earthing result upto 5 Ohms for each earthing. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum. (iv) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost
M&L for cutting hole of suitable size for exhaust fan of given size and making goof existing wall complete all as specified and directed by Engr -in- Charge.
Smruti Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .