MAHENDER SINGH
Municipal Corporation Faridabad
Redevelopment of Adarsh Nagar, Faridabad with Defect liability period of two years and including maintenance for 5 years under Smart City Mission. Recall
2026_HRY_514560_1
20267B92D33F B631 495C 8632 903B5177FC6E284ULB
Open Tender
Civil Works
Works
60 days
Faridabad (MC)
2 documents required · 2 mandatory
₹15,000
₹4.1 L
Yes
11 Apr 2026
11 Apr 2026
22 Apr 2026
11 Apr 2026
21 Apr 2026
11 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and fixing of reinforced Ferro-Cement drain covers designed for `A` class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc Standard Size 1500x600mm (125mm thick) for span 701 to 1200mm | - | Sqm | - | - |
| 2 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 25 mm dia. nominal bore | - | Metre | - | - |
| 3 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia. nominal bore | - | Metre | - | - |
| 4 | MAIN CUBICAL PANEL / STREET LIGHT CONTROL PANELP/F testing and commissioning of kiosk type weather proof out door
main cubical panel size 750 mm X 1250 mm X 500 mm (app.) made
out of 14 gauge MS sheet front and back both side openable duly
hinged door with locking arrangement by providing both side held
draft and all required hard wares. The cubical should be dust and
vermin proof followed by coat of zimpholite primer and finally two
coats of enamal gray paint. The cubical should be mounted with
hard ware on angle iron frame size 50 X 50 X 6 mm and 1500 legs
duly painted framed be grouted 750 mm below ground level with
cement concrete 1:3:6 in 1000 X 500 X 600 mm and providing brick
masonary along angle iron frame above G.L. They shall be in two
section comprising as follows:
(i) Providing and Fixing 415 V ,TP combination double break HRC
switch fuse unit .100 Amp. rating for incoming supply with HRC fuse
100 Amp rating and of BCH/LandT/EE/ Siemens/ ABB make.
(ii) Providing fixing timer switch TSQ 100 series 240 Volts, and full
running service standred mounting with base of L and T or equivalent
make including the cost of contactor 63 amp. 50 Hz. 440/400 volt.
(iii) P/F open busbars 25mmX3mm of required length duly covered
by heat shrinkable sleeves with busbar supporters
(iv) Provision for residual current operated 63 Amp. 1 Pole ELCB of
30MA to 300 MA sensitively as required including making
connections etc.(EE/Load stop make)
(v) P/F 2 Nos. 415 Volts TPN combination double break switch fuse
unit,63 Amp. Rating with HRC fuses (EE/mds/ SCHNEIDER
bch/Siemens )for outgoing cable and making connection etc. also to
have a provision for two nos. above switchs.
(vi) P/F of 3 nos. RYB phase indicator resitance type complete with
lamp
P/F of HT danger plate of size 200 X 150 mm made of aluminium
sheet 20 gauge.
(vii) P/F cable glands double compression type and Al. lugs duly
crimped for incoming cable and out going Cables.
(viii) Providing 2 Nos. earth terminals including lugs and H/W duly
inter connected with 8 SWG copper wire .
(ix)Inter connection of main busbar to each out going switch and
cable terminal shall be with 4 sqmm PVC copper conductor duly
crimped with AL lugs.
(x) Cable termination shall be fixed at backside of the panel with
H/W and spring washers
(xi) Light control switch with photo senser complete unit as required | - | Each | - | - |
| 5 | P/ F IP-65/ IP-66 protected street light luminaries on
existing bracket. Fixture made from powder coated
single piece pressure die cast aluminum housing with
heat dissipation fins on housing with high power LEDs .
Diffuser / glass cover for ensuring IP-65 protection for
lamp and control gear compartment, system lumen
output of 100 lum/watt high power LED. Integrated
driver shall be high efficiency having efficiency more
than 85 % and in compliance to IEC standards. System
life of 50000 burning hours with 70 % of initial lumens
maintained. Fixture shall be in CE compliance.
LED street light fixture 80-90 watt | - | Each | - | - |
| 6 | Supply and erection of Octagonal pole of following
length and dimension as per table-3 with base plate on
the cement concrete foundation of M-15 /M-20 grade
(1:1.5:3) with the help of anchor bolts of grade 6.8 (IS
1367 P III ). The pole shall be made of S-355JO grade
steel sheet , folded lengthwise to obtained Octagonal
shape, having single longitudinal seam weld and hot
dipped galvanised internally and externally in accordance
with IS 2629. The pole shall have a weatherproof flush
door and locking arrangements. The complete work
shall be supervised and certified by the manufacturers
for satisfactory supply, erection, testing and
commissioning. Single arm overhang | - | Each | - | - |
| 7 | Supply and installation of maintenance free Earthing with all alied material | - | Nos. | - | - |
| 8 | Supply and erection of 25 mm x 6 mm 9 mtr for earthing Wt. 10.80 Kg (Tata/ Sail make) | - | Nos. | - | - |
| 9 | Erection of G.I. Wire
GI Strip 25x6mm 9 mtr for earthing | - | Nos. | - | - |
| 10 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required | - | per | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
BOQ_593390.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .