Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 CrAccepted-AOC | ₹12.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹12.7 CrRejected-AOC | ₹12.7 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹12.8 CrRejected-AOC | ₹12.8 Cr | L3 | Rejected-AOC L4 |
| 4 | L4₹13.6 CrRejected-AOC A 703 KOLDONGRI SOCIETY PARSIWADA SAHAR ROAD ANDHERI EAST MUMBAI 400099 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400099 | ₹13.6 Cr | L4 | Rejected-AOC L3 |
| 5 | L5₹16.3 CrRejected-AOC | ₹16.3 Cr | L5 | Rejected-AOC L5 |
Tender Value
₹12.9 Cr
EMD Value
₹22.9 L
Closing Date
22 Oct 2019, 2:00 pmClosed
The Executive Engineer, PWD, WD-I, Daman.
The Executive Engineer, PWD, WD-I, Fort Area, Daman.
Providing furniture, false ceiling and other allied works for Govt. Engineering College, Varkund, Nani Daman.
2019_DAMAN_508_1
Tender Notice No.31/2019-20
Open Tender
Civil Works
270 days
Nani Daman.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
The Executive Engineer, PWD, WD-I, Daman.
₹22.9 L
The Executive Engineer, PWD, WD-I, Daman.
30 Mar 2020
12 Sept 2019
22 Oct 2019
12 Sept 2019
22 Oct 2019
12 Sept 2019
24 Sept 2019
Amount
Civil work
FURNITURE - A CASH COUNTER TABLE SIZE:-2700X800X750MM Top 25mm thick MDF with 1mm thick laminate side and modesty 18mm thick mdf with 1mm thick laminate finish.Front L Top&front made of 25mm thick MDF with 1mm thick laminate.Two drawer Unit - 400x450x675mm made of Top,side,drawer front and shutter 18mm thick mdf with 1mm thick laminate finish.drawer run on meta box and shutter hanging on auto hinges with lock..All edge pvc finish.Keyboard,cpu trolly etc all necessary hardware included as per design given by the architect and approved by the engineer in charge
BACK UNIT Top 25mm thick MDF with 1mm thick laminate side and Shelf 18mm thick mdf with 1mm thick laminate finish.shutter hanging on auto hinges with lock.All edge pvc finish.all necessary hardware included.Back unit 450mmD as per design given by the architect and approved by the engineer in charge
Providing and supplying Executive highback chair of Center tilt mechanism, size of chair W-725 X D 700 X H 1145/1240, seat height with permanent contract mechanism with 360 degrees swivel mechanism for adapts to shifts posture. The chair include pneumatic seat height adjustment, tilt adjustment for back and also with two pair of caster PU UpholsteryCentre Tilt Mechanism Dual tone Handles with wood and Aluminium for Elegant look Aluminium Star Base Nylon Casters. 5 legged revolving molded nylon chair base with good quality of PU castors. as per design given by the architect and approved by the engineer in charge
Providing and supplying Mesh Back high chair size W 660 X D 620 X 1135/1235 H with fabric upholestery on Pu Foam Seat, Adjustable head rest and arm rest, adjustable lumbor support, self adjutable mechanism with 4 locking position with nylon caster and star base, nylon star base for extra load carrying capacity, The chair include pneumatic seat height adjustment, tilt adjustment for back and also with two pair of caster, as per design given by the architect and approved by the engineer in charge
Providing and supplying visitor chair size of W-550 X 605 D X 788 H , SS Tubular frame and legs with diameter of 16 mm, arm rest made of PVC for extra support and comfort, seat and back made of PVC upholestered. provide special interlock facility with nylon cap footcap as per design given by the architect and approved by the engineer in charge VISITOR CHAIR
Providing and supplying visitor chair size of W-507 X 570 D X 755 H, SS Tubular frame and legs with diameter of 16 mm, seat and back made of PVC upholestered. provide special interlock facility with nylon cap footcap as per design given by the architect and approved by the engineer in charge VISITOR CHAIR
CHAIR-COMPUTER/LIBRARY PLY SEAT WITH CUSHION PVC MOLDED BACK REST WITHOUT ARMS, BOTTOM MADE FROM 25 MM PIPE AND 16 SWG (STANDARD WIRE GAUGE) OR OVAL PIPE OF SUITABLE CROSS SECTION, POWDER COATING as per design given by the architect and approved by the engineer in charge
Providing and supplying cafeteria chair injection-moulded polypropylene shell, no armrest, 4-leg chair 19mm tubular steel with silver epoxy frame. Shell moulded in tough recyclable polypropylene, available in various colour. It features laumbar-supporting profile & flexes comfortably as you lean back. Applications both indoors & outdoors, size of chair 450 W X 587 D X 805 H as per design given by the architect and approved by the engineer in charge
OUTER AREA CAFÉ TABLE SIZE:-1500X1500X750MM Top 25mm thick MDF with 1mm thick laminate finis.Under structure made of 50x50x1.6mm thick MS sq pipe powder coated finish. as per design given by the architect and approved by the engineer in charge
Providing and supplying Bar stool size of W-510 X D-510 X H 865-1075, Seat made of Hard PVC upholestered with with PU foam, the stool include gas lift height adjustment, 210 mm stroke gas lift for height adjustment, under structure made of MS chrome, wider base to provide good support as per design given by the architect and approved by the engineer in charge
FACULTY TABLE SIZE:-1200X600X750MM Top & leg 36 mm thick MDF NAIL curvica with laminate finish. and modesty of 18 mm thick MDF with 1mm thick laminate and backing 0.8mm thick laminate finish.Pvc beading will be provided on periphery.MDU SIZE:-400 X 450 X 650mm top and side 18 mm thick MDF 1mm laminate with pvc edge bidding finish drawer made of 18 mm thick mdf with bullnoze curvica laminate finish with lock,all nessary heardwear includead. as per design given by the architect and approved by the engineer in charge
WHITE BOARD SIZE:-2400X1200MM Ultra Plus Boards Triple coated steel surface with a top coat of acrylic resin over a galvanized steel base.urface smooth & glossy with good surface hardness.Resists scratches.Fixing screw, anchor plugs, pen trays provided.Easy fixing new plastic hanging bracketsEasy fixing metal corners also provided.Accepts Magnets as per design given by the architect and approved by the engineer in charge
LABORATRY TABLE:-1500X1000X900MM Top 18mm made of Commercial ply Under structure made of 50x50x1.6mm thick MS sq pipe powder coated finish with all necessary hardware included. as per design given by the architect and approved by the engineer in charge
LABORATRY TABLE:-1500X1000X900MM Top 18mm thick granite table top.Under structure made of 50x50x1.6mm thick MS sq pipe powder coated finish with all necessary hardware included. as per design given by the architect and approved by the engineer in charge
LABORATRY TABLE:-1500X1500X900MM 18mm thick granite table top. under steucture Welded cabinet body should be of flush face construction with intersection of vertical and horizontal members like LH and RH side panel along with front horizontal channel, back panel and bottom panel. It should be relocated anywhere easily as it is an independent unit. Cabinet should be of square non-sharp edge construction. Doors should be assembled with SS-304 hinge assembly. Removable back panel should be provided to easily access the service lines running behind the cabinet benches. Intermediate horizontal channels should be provided between door and drawer. Shelf should be eight bend panel with 20mm height. Drawer tray should be of single piece construction. Drawer should be well supported on LH and RH ball slide suspension system. Steel door and drawer front is of double wall construction with sound dampening material filled inside. Doors should be easily removable and hinges should be easily replaceable. Knee space panel should be in 22 gauge construction. Storage Units to be of the Suspended Type Dimensions: W=1500mm, D = 750mm, H = 750 mm. Configurations: 2 Shutters 1 Drawer MOC: MSCRCA: IS – 513 (1994), Thickness: LH/RH side panels, shutter front, Bottom panel, Top front, Drawer separator, shelf, Alignment channel should be of 1.2mm thk. Removable Back panel, Shutter cover, Fr. Rack strip, Top cover panel should be of 0.8mmthk. Finish: Powder coating pure epoxy, thickness 40-50 microns. Handle: Anodized Aluminum Recessed-Type, CTC: 160.0mm. Lock: Units have a locking facility with 180° and 10 lever cam lock mechanism (except for sink and corner unit). Hinge: Knuckle-butt type SS Hinge. Screw: SS304. Shutter should be of twin-type construction with sound dampening effect using profeel. Shutter cover should be equipped with Bump on for sound dampening. Ball Slide: 500mm Length (required only for drawer unit). Shutter should have provision of roller catch. cabinet work is executed as per intruction of engineer incharge. Front clear installed area should be measerd and paid as per design given by the architect and approved by the engineer in charge
LAB STOOL Round Top 300 dia 18mm thick MDF with 1mm thick laminate with 38mm dia round pipe powder coated finish. 650mm ht of stool. as per design given by the architect and approved by the engineer in charge
GLASS STORAGE (450MM DEPTH) Top 25mm thick MDF with 1mm thick laminate finish.Side shlef shutter made of 18mm thick mdf with 1mm thick laminate finish.4mm thick glass in shutter with crank stopper and lock.Back 8mm thick mdf with 1mm thick laminate finish. All edge pvc finish with all necessary hardware included. as per design given by the architect and approved by the engineer in charge
FULL HT.STORAGE (450MM DEPTH) Top 25mm thick MDF with 1mm thick laminate finish.Side shelf shutter made of 18mm thick mdf with 1mm thick laminate finish.Back 8mm thick mdf with 1mm thick laminate finish.crank stopper and lock.All edge pvc finish with all necessary hardware included.
WALL BENCH WITH STORAGE(750MM DEPTH) 18mm thick granite table top. under steucture Welded cabinet body should be of flush face construction with intersection of vertical and horizontal members like LH and RH side panel along with front horizontal channel, back panel and bottom panel. It should be relocated anywhere easily as it is an independent unit. Cabinet should be of square non-sharp edge construction. Doors should be assembled with SS-304 hinge assembly. Removable back panel should be provided to easily access the service lines running behind the cabinet benches. Intermediate horizontal channels should be provided between door and drawer. Shelf should be eight bend panel with 20mm height. Drawer tray should be of single piece construction. Drawer should be well supported on LH and RH ball slide suspension system. Steel door and drawer front is of double wall construction with sound dampening material filled inside. Doors should be easily removable and hinges should be easily replaceable. Knee space panel should be in 22 gauge construction. Storage Units to be of the Suspended Type Dimensions: W=1000mm, D = 750mm, H = 750 mm. Configurations: 2 Shutters 1 Drawer MOC: MSCRCA: IS – 513 (1994), Thickness: LH/RH side panels, shutter front, Bottom panel, Top front, Drawer separator, shelf, Alignment channel should be of 1.2mm thk. Removable Back panel, Shutter cover, Fr. Rack strip, Top cover panel should be of 0.8mmthk. Finish: Powder coating pure epoxy, thickness 40-50 microns. Handle: Anodized Aluminum Recessed-Type, CTC: 160.0mm. Lock: Units have a locking facility with 180° and 10 lever cam lock mechanism (except for sink and corner unit). Hinge: Knuckle-butt type SS Hinge. Screw: SS304. Shutter should be of twin-type construction with sound dampening effect using profeel. Shutter cover should be equipped with Bump on for sound dampening. Ball Slide: 500mm Length (required only for drawer unit). Shutter should have provision of roller catch. cabinet work is executed as per intruction of engineer incharge. Front clear installed area should be measerd and paid as per design given by the architect and approved by the engineer in charge
WALL BENCH WITH STORAGE(600 MM DEPTH) 18mm thick granite table top. under steucture Welded cabinet body should be of flush face construction with intersection of vertical and horizontal members like LH and RH side panel along with front horizontal channel, back panel and bottom panel. It should be relocated anywhere easily as it is an independent unit. Cabinet should be of square non-sharp edge construction. Doors should be assembled with SS-304 hinge assembly. Removable back panel should be provided to easily access the service lines running behind the cabinet benches. Intermediate horizontal channels should be provided between door and drawer. Shelf should be eight bend panel with 20mm height. Drawer tray should be of single piece construction. Drawer should be well supported on LH and RH ball slide suspension system. Steel door and drawer front is of double wall construction with sound dampening material filled inside. Doors should be easily removable and hinges should be easily replaceable. Knee space panel should be in 22 gauge construction. Storage Units to be of the Suspended Type Dimensions: W=1166mm, D = 600mm, H = 750 mm. Configurations: 2 Shutters 1 Drawer MOC: MSCRCA: IS – 513 (1994), Thickness: LH/RH side panels, shutter front, Bottom panel, Top front, Drawer separator, shelf, Alignment channel should be of 1.2mm thk. Removable Back panel, Shutter cover, Fr. Rack strip, Top cover panel should be of 0.8mmthk. Finish: Powder coating pure epoxy, thickness 40-50 microns. Handle: Anodized Aluminum Recessed-Type, CTC: 160.0mm. Lock: Units have a locking facility with 180° and 10 lever cam lock mechanism (except for sink and corner unit). Hinge: Knuckle-butt type SS Hinge. Screw: SS304. Shutter should be of twin-type construction with sound dampening effect using profeel. Shutter cover should be equipped with Bump on for sound dampening. Ball Slide: 500mm Length (required only for drawer unit). Shutter should have provision of roller catch. electrical duck on top with 2 socket and 2 switch.cabinet work is executed as per intruction of engineer incharge. Front clear installed area should be measerd and paid as per design given by the architect and approved by the engineer in charge
WALL BENCH WITH STORAGE(900MM DEPTH) 18mm thick granite table top. under steucture Welded cabinet body should be of flush face construction with intersection of vertical and horizontal members like LH and RH side panel along with front horizontal channel, back panel and bottom panel. It should be relocated anywhere easily as it is an independent unit. Cabinet should be of square non-sharp edge construction. Doors should be assembled with SS-304 hinge assembly. Removable back panel should be provided to easily access the service lines running behind the cabinet benches. Intermediate horizontal channels should be provided between door and drawer. Shelf should be eight bend panel with 20mm height. Drawer tray should be of single piece construction. Drawer should be well supported on LH and RH ball slide suspension system. Steel door and drawer front is of double wall construction with sound dampening material filled inside. Doors should be easily removable and hinges should be easily replaceable. Knee space panel should be in 22 gauge construction. Storage Units to be of the Suspended Type Dimensions: W=1800mm, D = 900mm, H = 750 mm. Configurations: 2 Shutters 1 Drawer MOC: MSCRCA: IS – 513 (1994), Thickness: LH/RH side panels, shutter front, Bottom panel, Top front, Drawer separator, shelf, Alignment channel should be of 1.2mm thk. Removable Back panel, Shutter cover, Fr. Rack strip, Top cover panel should be of 0.8mmthk. Finish: Powder coating pure epoxy, thickness 40-50 microns. Handle: Anodized Aluminum Recessed-Type, CTC: 160.0mm. Lock: Units have a locking facility with 180° and 10 lever cam lock mechanism (except for sink and corner unit). Hinge: Knuckle-butt type SS Hinge. Screw: SS304. Shutter should be of twin-type construction with sound dampening effect using profeel. Shutter cover should be equipped with Bump on for sound dampening. Ball Slide: 500mm Length (required only for drawer unit). Shutter should have provision of roller catch. electrical duck on top with 2 socket and 2 switch.cabinet work is executed as per intruction of engineer incharge. Front clear installed area should be measerd and paid as per design given by the architect and approved by the engineer in charge
STAGE 150MM HEIGHT Stage made of 18+18mm thick MR grad plywood vertical and horizontal support coverd with 18mm thick mr grad plywood with 1mm thick laminate / 1mm thick pvc carpet. as per design given by the architect and approved by the engineer in charge
TUTORIAL ROOM CHAIRFIX CHAIR Providing and supplying Half tablet size of chair 550 W X 605 D X 788 H, Frame and legs should be made of 1mm thk tube with diameter of 16mm stainless steel, ARM REST made of PU, seat and back made of PVC Upholstred on 12 mm plywood covered with PU Foam, PVC 16 GAUGE CRC WITH INSERT SUPORT POWDER COATED PIPE FRAME STRUCTURE (with writing ped.) Writing pad made of Pre laminated ply board with PVC Edge banding. writing pad diamension 4440 W X 260 D X 17.2 H in mm, Chair height- mm, Back cover height mm, Seat height mm, Seat dim WxD, outer dim WxD as per design given by the architect and approved by the engineer in charge
COMPUTER TABLE SIZE:-1200X600X750MM Linear workstation Height of Partition- 450mm: Considred with Non Framed fabric magnetic in 18 mm . Privacy panel 750mmL x450mm HT:: Legs: Open type legs 50mmx50mm : Under structure: Metal powder coated: Table tops is Pre lam 25 mm thick mdf with 1mm thick laminate with PVC lipping; Cable Management: Wire trunking to be provided made up of MS below worktop with clear data power seperation,Round wire manager to be provided on table top , single trunking system to be provided with Electrical panel to take wires into the cable manager. as per design given by the architect and approved by the engineer in charge
RECEPTION TABLE SIZE:-1500X600X750 Top 25mm thick MDF with 1mm thick laminate side and modesty 18mm thick mdf with 1mm thick laminate finish.Front L Top&front made of 25mm thick MDF with 1mm thick laminate.one drawer Unit - 400x450x675mm made of Top,side,drawer front and shutter 18mm thick mdf with 1mm thick laminate finish.drawer run on meta box and shutter hanging on auto hinges with lock..All edge pvc finish.Keyboard,cpu trolly etc all necessary hardware included as per design given by the architect and approved by the engineer in charge
THREE SEATER SOFA - 2100x800x800mm Providing and fixing Sofa sturcture made from 18mm hardply wood supported with maranti Solid wood, back side and curved part Covered with 3mm flexi ply , sofa arm made from 12mm thick hard plywood supported with maranti solid wood . 75mm board & 2.25 mm thick elastic webbing stapling in seat frame at 100mm centre to centre distance, belt fastern in x & y axies of saet, elastic belt elongation 45% tensile strength 350 kg.100mm x 40 density polyurathane block foam covered with 25mm x 32 density super soft plyurathane Foam for soft touch filling in seat.50 mm x 32 density polyurathane bloack foam covered with 25mm x 32 density super soft polyurathne foam for soft touch filling in back.Stiching work done with well known german brand ( Aman / Gurtamen ) Thread. Nylone & polyster thread used as per application.SS 202 Grade used in sofa leg & leg sofa frame with mirror finish look.Aluminum presure die casted leg with mirror finish.wooden leg and frame made from Ghana specail teak wood with melamine finish. ALL SOFA HAVE STANDERD SIZE CUSTMIZATION NOT AVAILABLE as per design given by the architect and approved by the engineer in charge
TWO SEATER SOFA - 1500x800x800mm Providing and fixing Sofa sturcture made from 18mm hardply wood supported with maranti Solid wood, back side and curved part Covered with 3mm flexi ply , sofa arm made from 12mm thick hard plywood supported with maranti solid wood . 75mm board & 2.25 mm thick elastic webbing stapling in seat frame at 100mm centre to centre distance, belt fastern in x & y axies of saet, elastic belt elongation 45% tensile strength 350 kg.100mm x 40 density polyurathane block foam covered with 25mm x 32 density super soft plyurathane Foam for soft touch filling in seat.50 mm x 32 density polyurathane bloack foam covered with 25mm x 32 density super soft polyurathne foam for soft touch filling in back.Stiching work done with well known german brand ( Aman / Gurtamen ) Thread. Nylone & polyster thread used as per application.SS 202 Grade used in sofa leg & leg sofa frame with mirror finish look.Aluminum presure die casted leg with mirror finish.wooden leg and frame made from Ghana specail teak wood with melamine finish. ALL SOFA HAVE STANDERD SIZE CUSTMIZATION NOT AVAILABLE as per design given by the architect and approved by the engineer in charge
CENTER TABLE GLASS should be 1200 (W) x 600(D) x 400 (H), 12mm thick Toughened Glass with understructure having Dia 12mm thick SS 304
CORNER TABLEGLASS should be 525(W) x 525(D) x 400 (H), 12mm thick Toughened Glass with understructure having Dia 12mm thick SS 304 as per design given by the architect and approved by the engineer in charge
FULL HT. SOLID PARTATION Providing and fixing wooden FULL HT. SOLID PARTATION made of framing the skeleton(plywood frame structure)with 18mm + 18mm thick MR grade plywood for vertical and horizontal plywood (patti) both side cover with 6mm thick MR grade plywood for grooving as per design.Fixing properly without any air gap and finishing with seletced 1.00 mm thick laminate Before installation,make hole/face plate for conduit pipes of eletcrical/networking cables with openable stud from partition Including all materials and labour etc.complete as per detail drawing and instruction of engineer-in charge. as per design given by the architect and approved by the engineer in charge
LOW HT. SOLID PARTATION Providing and fixing wooden LOW HT. SOLID PARTATION made of framing the skeleton(plywood frame structure)with 18mm + 18mm thick MR grade plywood for vertical and horizontal plywood (patti) both side cover with 6mm thick MR grade plywood for grooving as per design.Fixing properly without any air gap and finishing with seletced 1.00 mm thick laminate Before installation,make hole/face plate for conduit pipes of eletcrical/networking cables with openable stud from partition Including all materials and labour etc.complete as per design given by the architect and approved by the engineer in charge
STAFF/PA TABLE SIZE:-1500X600X750MM Top & leg 36 mm thick MDF NAIL curvica with laminate finish. and modesty of 18 mm thick MDF with 1mm thick laminate and backing 0.8mm thick laminate finish.Pvc beading will be provided on periphery.MDU SIZE:-400 X 450 X 650mm top and side 18 mm thick MDF 1mm laminate with pvc edge bidding finish drawer made of 18 mm thick mdf with bullnoze curvica laminate finish with lock,all nessary heardwear includead. as per design given by the architect and approved by the engineer in charge
STAFF SIDE TABLE SIZE:-1000X450X750MM Top 36mm thick mdf nail curvica laminate with 2mm thick pvc edge bidding finish.Side,shelf,drawer,shutter18mm thick mdf with 1mm thick pvc edge bidding finish.Back 8mm thick prelam mdf finish.drawer run on meta box & shutter hanging on auto hinges with multi lock and handle etc all necessary hardware included. as per design given by the architect and approved by the engineer in charge
PRINCIPAL TABLE SIZE:-2400X900X750MM Work Table. Size:- 2100x900x760 mm Top & Leg -50mm thick MDF reverse bull nose with Curvica laminate finish. Apron 25 mm thick MDF board with 1 mm laminate finish.Side Table. Size:1200x450x710 mm.Outer body 25 mm thick MDF reverse bull nose with curvica laminate finish.Three drawers and three Openable shutters with 1mm laminate finish. Mobile Drawer Unit. Size:450x550x650 mm Outer body 25 mm thick MDF reverse bull nose with curvica laminate finish.three drawers with 1mm Laminate finish.Back Unit. Size:2100x460x760 mm Outer Body 25 mm thick MDF reverse bull nose with curvica laminate finish.Five Drawer & Five Openable Shutters with 1mm laminate finish. as per design given by the architect and approved by the engineer in charge
H.O.D TABLE SIZE:-2400X900X750MM Top & leg 36 mm thick MDF NAIL curvica with laminate finish. and modesty of 18 mm thick MDF with 1mm thick laminate and backing 0.8mm thick laminate finish.Pvc beading will be provided on periphery.MDU SIZE:-400 X 450 X 650mm top and side 18 mm thick MDF 1mm laminate with pvc edge bidding finish drawer made of 18 mm thick mdf with bullnoze curvica laminate finish with lock,all nessary heardwear includead. as per design given by the architect and approved by the engineer in charge
H.O.D SIDE TABLE SIZE:-1200X450X750MM Top & leg 36 mm thick MDF NAIL curvica with laminate finish. and modesty of 18 mm thick MDF with 1mm thick laminate and backing 0.8mm thick laminate finish.Pvc beading will be provided on periphery.MDU SIZE:-400 X 450 X 650mm top and side 18 mm thick MDF 1mm laminate with pvc edge bidding finish drawer made of 18 mm thick mdf with bullnoze curvica laminate finish with lock,all nessary heardwear includead. as per design given by the architect and approved by the engineer in charge
PANTRY UNDER STORAGE (600 MM DEPTH) pantry storage Drawer and shutter made 18mm thick BWR plywood with 1mm thick laminate finish.Drawer box made of BWR plywood with bothside 1mm thick laminate.shutter haning on auto hinges with nessary hardware included. as per design given by the architect and approved by the engineer in charge
XEROX/PRINTER TABLE SIZE:-2230X600X750MM \Top & leg 36 mm thick MDF NAIL curvica with laminate finish. and modesty of 18 mm thick MDF with 1mm thick laminate and backing 0.8mm thick laminate finish.Pvc beading will be provided on periphery.MDU SIZE:-400 X 450 X 650mm top and side 18 mm thick MDF 1mm laminate with pvc edge bidding finish drawer made of 18 mm thick mdf with bullnoze curvica laminate finish with lock,all nessary heardwear includead. as per design given by the architect and approved by the engineer in charge
CONFERENCE TABLE SIZE:-4000X1500X750MM Top 25mm thick mdf with 1mm laminate.Apron 18mm thick mdf with 1mm thick pvc edge bidding finish. .Under structure made of 50x50x1.6mm thick MS sq pipe powder coated finish.Two Pop up box with vertical cable manager for wireing with all necessary hardware included. as per design given by the architect and approved by the engineer in charge
CLASS ROOM BENCH SIZE:-3080X400X750MM Top 25mm thick mdf with 1mm thick laminate finish with teakwooden edge bidding.Modesty 18mm hick mdf with 1mm thick laminate finish with teakwooden edge bidding.Under structure made of 50x25x1.6mm ms sq pipe with 25x25x1.6mm under top support powder coated finish.provision for grouting of bench having 12mm thick ms plate at base. as per design given by the architect and approved by the engineer in charge
THREE SEATER BENCH SIZE:-1650X400X750MM Top 25mm thick mdf with 1mm thick laminate finish with teakwooden edge bidding.Modesty 18mm hick mdf with 1mm thick laminate finish with teakwooden edge bidding.Under structure made of 50x25x1.6mm ms sq pipe with 25x25x1.6mm under top support powder coated finish.provision for grouting of bench having 12mm thick ms plate at base. as per design given by the architect and approved by the engineer in charge
PODIUM - 750x600x1200 All structure made of 18mm thick mdf with 1mm thick laminate finish.inside two shelf with cable manager for wiring. as per design given by the architect and approved by the engineer in charge
Seat & Back cushioned on Ply, Seat with PU mould, PVC beading L- type is fitted at bottom of seat .The understructure made up of 25 mm dia 2mm thick tubular main frame inserted with 19 mm Dia 1.6 thick pipe, 60 micron powder coated, PU pad on arm rest. as per design given by the architect and approved by the engineer in charge
Namestey Bench-Providing and supplying modules Front/Middle/Rear Desk, A platform based design with self closing seat & desk opening closing System. seater with desk for front module, seater with seat & desk for middle module and seater with seat for rear module A)Understructure: The understructure is made with steel ERW tube section(IS:228) of size 80x40x2.5mm thick with powder coat finish. -Understructure consists of two welded leg assemblies connected by means of welded seat side tube assy and welded desk side tube assy on both sides. -Sturdy anchoring by anchor bolts on to base of 10mm thk plate for proper resting of structure**. -Plastic clad & shoe main clad made of glass filled 30% nylon-6 for covering anchor bolts. B) Side clads: Two side clads made of 35mm thk plt with 2mm thk pvc lipping. Desk side clad made of 18mm thk plt & seat side clad &connecting clad made of 25mm thk plt. C) Desklet: -Desk has opening & closing mechanism by means of desk slider and slider sleeve made of 30% glass filled nylon-6. -Desk comprises of plt desk with aluminium section anodized finish on to sides and TPE rubber on to aluminium section outer side for cushioning effect for desk opening closing. -Desk made of 18mm thk plt fixed with aluminium extrusion on to sides for desk opening closing. D) Seat: Seat has self closing mechanism which will operate by means of spring. -Seat understructure is a combination of welded fabricated structure made of Ø19X2mmthk ERW tube with powder coat finish which is covered by 0.8mm thk sheet metal cover and uphlosterd with moulded foam inside and leatherite cover. -Seat back comprises of ply with moulded foam upho losted inside & leatherite cover. E) Wire carrier: Wire carrier made of 0.8mm thk sheet metal for holding wire passings. F) Switch box: Switch box made of 1.2mm thk sheet metal for switch plate mounting suitable for anchor roma plates. G) Front clad Mounting: Front clad mounting made of 18MM thk plt with sheet metal cover and bracket for holding on to top and mounting box for holding of clad with seat side clad. Product should be Indian Design Mark. as per design given by the architect and approved by the engineer in charge. Providing and Placing 3 Seater Module Front Desk (2044mm Width X 698.5mm Depth X 890mm Height)
Providing and Placing 3 seater Module- Seat with Desk ( 2044mm Width X 1080mm Depth X 890mm Height)
Providing and Placing 3 Seater Module Rear Seat (2044mm Width X 698.5mm Depth X 890mm Height)
Providing and Placing 4 Seater Fronttype Desk Size shall be 2713mm Width X 751mm Depth X 890mm Height
Providing and Fixing 4 Seater Midtype size shall be 2713mm Width X 1080mm Depth X 890mm Height
Providing and Fixing 4 Seater Reartype size shall be 2713mm Width X 751mm Depth X 890mm Height
Providing and fixing Free Standing table metal legs under structure in powder coated. Prelam board duly edge bended. TrendZ Series. as per design given by the architect and approved by the engineer in charge MANTENANCE ROOM TABLE SIZE:-1500X750X750MM
LIBRARY ISSUE/RETURN COUNTER:-3600X600X750/1050MM Top 25mm thick MDF with 1mm thick laminate side and modesty 18mm thick mdf with 1mm thick laminate finish.Front L Top&front made of 25mm thick MDF with 1mm thick laminate.Two drawer Unit - 400x450x675mm made of Top,side,drawer front and shutter 18mm thick mdf with 1mm thick laminate finish.drawer run on meta box and shutter hanging on auto hinges with lock..All edge pvc finish.Keyboard,cpu trolly etc all necessary hardware includedas per design given by the architect and approved by the engineer in charge
LIBRARY ISSUE/RETURN STORAGE Top 25mm thick MDF with 1mm thick laminate side and Shelf 18mm thick mdf with 1mm thick laminate finish.shutter hanging on auto hinges with lock.All edge pvc finish.all necessary hardware included.Back unit 450mmD as per design given by the architect and approved by the engineer in charge
MAGAZINE RACK SIZE:-3000X450X2100M MAll structure made of 18mm thick mdf with 1mm thick laminate with 2mm thick pvc edge bidding finish.upper three shelf sliding openablewith back side storage for book. as per design given by the architect and approved by the engineer in charge
18 DOORS LOCKER SIZE:- 900X450X1950MM Size:1981 x 914 x 483mm Providing and Arranging Eighten steel locker having body made of CRC Steel top,side and back 20 Gauge.Door CRC steel 20 Gauge finished with epoxy polymer powder coating 50 micron thickness made with lockers can be provided locks. All lockers have vantilating louvers for air circulation & label holder for each identification.Including all materials and labour etc.complete as per detail drawing and instruction of engineer-in chargeas per design given by the architect and approved by the engineer in charge
LIBRARIAN TABLE SIZE:-1650X600X750MM Top & leg 36 mm thick MDF NAIL curvica with laminate finish. and modesty of 18 mm thick MDF with 1mm thick laminate and backing 0.8mm thick laminate finish.Pvc beading will be provided on periphery.MDU SIZE:-400 X 450 X 650mm top and side 18 mm thick MDF 1mm laminate with pvc edge bidding finish drawer made of 18 mm thick mdf with bullnoze curvica laminate finish with lock,all nessary heardwear includead. as per design given by the architect and approved by the engineer in charge
OPEN RACK - 900x375x2100 mm Providing supply and arranging Slotted angle book rack Size: 7' Hx 3'L x 1'3"D made of 40x40x2mm thick slotted angle rack having load bearing members made of high strength MS angle with having six shelving 18 Guage CRCA sheet , making seven compartment, three side close with 20 Guage CRCA sheet all the components having powder coating with thoroughly 7 tank anti rust treatment including all necessary fixture, fastners, fittings, labour material machinary etc complete as per design given by the architect and approved by the engineer in charge
LIBRARY READING TABLE SIZE:-2400X1200X750/1200MM (WITH DIVIDER SCREENS) Linear workstation Height of Partition- 450mm: Considred with Non Framed fabric magnetic in 18 mm . Privacy panel 750mmL x450mm HT:: Legs: Open type legs 50mmx50mm : Under structure: Metal powder coated: Table tops is Pre lam 25 mm thick mdf with 1mm thick laminate with PVC lipping; Cable Management: Wire trunking to be provided made up of MS below worktop with clear data power seperation,Round wire manager to be provided on table top , single trunking system to be provided with Electrical panel to take wires into the cable manager. as per design given by the architect and approved by the engineer in charge
LIBRARY READING TABLE SIZE:-1800X1200X750MM (WITH DIVIDER SCREENS) Top 25mm thick MDF with 1mm thick laminate finis.Under structure made of 50x50x1.6mm thick MS sq pipe powder coated finish. as per design given by the architect and approved by the engineer in charge
RECEPTION TABLE SIZE:-1200X600X700MM Top 25mm thick MDF with 1mm thick laminate side and modesty 18mm thick mdf with 1mm thick laminate finish.Front L Top&front made of 25mm thick MDF with 1mm thick laminate.one drawer Unit - 400x450x675mm made of Top,side,drawer front and shutter 18mm thick mdf with 1mm thick laminate finish.drawer run on meta box and shutter hanging on auto hinges with lock..All edge pvc finish.Keyboard,cpu trolly etc all necessary hardware included as per design given by the architect and approved by the engineer in charge
FACULTY DISCUSSION TABLE SIZE:-1800X1000X750MM Top 25mm thick mdf with 1mm laminate.Apron 18mm thick mdf with 1mm thick pvc edge bidding finish. .Under structure made of 50x50x1.6mm thick MS sq pipe powder coated finish one Pop up box with vertical cable manager for wireing with all necessary hardware included.with all necessary hardware included .as per design given by the architect and approved by the engineer in charge
DISCUSSION ROUND TABLE:-1200 DIA X 750 HT.MM Top 25mm thick mdf with 1mm thick laminate 2mm thick pvc edge bidding finish.Under structure made of 90mm thick dia round pipe.12mm thick ms plat with all powder coated structure. as per design given by the architect and approved by the engineer in charge
LIBRARY READING TABLE SIZE:-2400X1200X750/1200MM (WITHOUT DIVIDER SCREENS) Linear workstation Height of Partition- 450mm: Considred with Non Framed fabric magnetic in 18 mm . Privacy panel 750mmL x450mm HT:: Legs: Open type legs 50mmx50mm : Under structure: Metal powder coated: Table tops is Pre lam 25 mm thick mdf with 1mm thick laminate with PVC lipping; Cable Management: Wire trunking to be provided made up of MS below worktop with clear data power seperation,Round wire manager to be provided on table top , single trunking system to be provided with Electrical panel to take wires into the cable manager. as per design given by the architect and approved by the engineer in charge
COMPUTER TABLE SIZE:-900X550X750 Linear workstation Height of Partition- 450mm: Considred with Non Framed fabric magnetic in 18 mm . Privacy panel 750mmL x450mm HT:: Legs: Open type legs 50mmx50mm : Under structure: Metal powder coated: Table tops is Pre lam 25 mm thick mdf with 1mm thick laminate with PVC lipping; Cable Management: Wire trunking to be provided made up of MS below worktop with clear data power seperation,Round wire manager to be provided on table top , single trunking system to be provided with Electrical panel to take wires into the cable manager. as per design given by the architect and approved by the engineer in charge
CLASS ROOM TABLE - 1200x600x750mm Top 25mm thick mdf with 1mm laminate.Apron 18mm thick mdf with 1mm thick pvc edge bidding finish. .Under structure made of 50x50x1.6mm thick MS sq pipe powder coated finish with all necessary hardware included as per design given by the architect and approved by the engineer in charge
DRAFTING TABLE SIZE :-1100X800X900MM Top 25mm thick mr grad plywood with 1mm thick laminate.all edge teakwood melamine polish with bottom side one strip to hold paper.under structure made of 25x25x1.6mm thick ms sq pipe powder coated.150mm adjustable height of top for drafting. as per design given by the architect and approved by the engineer in charge
DRAFTING TABLE STOOL Round Top 300 dia 18mm thick MDF with 1mm thick laminate with 38mm dia round pipe powder coated finish. 650mm ht of stool. as per design given by the architect and approved by the engineer in charge
wooden flooring
Providing and supplying S.S. Perforated Dust Bins of size 230MM Dia X 350mm Ht made from standard manufacturer. as per design given by the architect and approved by the engineer in charge
Providing and fixing name/sign plate of thicness 1.5mm and any size with text and graphics made of stainless steel 316 grade of kich, orchid or equivalent make including fixing with gum etc complete as per design given by the architect and approved by the engineer in charge
Full Height - Partly Glass partitions - 85.mm Series Providing and fixing of full height Partly Glass partition made out of horizontal & vertical aluminum structural sections. Exposed section in annodizing. Partition with 85mm series with 12.mm prelam board sandwich type. Plus 6.mm Clear Float Glass with Single Glass section duly anodised. as per design given by the architect and approved by the engineer in charge
Door Cabin Doors Providing and fixing door made of flush door with both side laminate. All edges are covered with aluminum profile with glass widow in 5mm clear Clear Float glass. Neccesory harware Door Closure of Geze make. Other Handle + Lock Body + Cylinder of Archies or Doorset or TPI + Door Stopper or Equivalent. as per design given by the architect and approved by the engineer in charge
Door jam Cabins Door jam is made of aluminum section duly anodized or powder coated with rubber gasket as per design given by the architect and approved by the engineer in charge
Joinery Post made out of Aluminum Duly Powder coated as per design given by the architect and approved by the engineer in charge
Metal KBD Trey - telescopic Slide with Metal Brackets as per design given by the architect and approved by the engineer in charge
FALSE CEILING WORK Plain gypsum board ceiling: Providing and Fixing 12.5mm Plain gypsum false ceiling Suspension( considering all levels with require all fabrication work and fitting from RCC slab to false ceiling up to 150 to600 mm & The rate shall be consider in sqm for all floors and at all heights ,Offsets whether cove light or fixed gypsum board size up to 100 mm to 1200 mm in the false ceilings including all costs) Providing and fixing Suspended ceiling using Gypsum or equivalent of G. I. Perimeter Channels of size 0.45mm thick having one flange of 20mm and another flange of 30mm and web 27mm along with perimeter of ceiling, screw fixed to brick wall / partitions with the help of nylon sleeves and screws, at min. 600 mm centers. Then suspending G. I. intermediate channel of size 45mm, 0.6mm thick with two flanges of 15mm each from the soffit at 1220mm centers with ceiling angle of width 25mm x 10mm x 0.55mm thick fixed to soffit with G. I. cleat and steel expansion fasteners. Ceiling section of 0.45mm thickness having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm centers. 12.5mm gypsum Plain Board (conforming to IS 2095 part 1 2011) is then screw fixed to ceiling section with 25mm dry wall screwed at 230mm centers. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the edges of the boards with jointing compound, Joint paper tape and two coats of Drywall top coat suitable for Gypsum Board. Cutouts For light fittings, grill diffusers shall be made. Necessary cutting / providing openings in the ceiling for AC fixtures, grills, electrical fittings, or other utility services, hatch openings etc. shall be provided by the Contractor and cost of making such modifications shall be included in the price. No separate charges for cutting / providing opening will be paid. Trap doors with necessary ply frame work to be provided as required at no extra cost.Joints between the two gypsum board, (Board placed staggered) gypsum board and wall will have suitable tape and finishes with plaster of paris so as to have crack free joints. as per design given by the architect and approved by the engineer in charge
Accoustic Grid ceiling : Providing & Fixing of Soft Fibre Acoustical Suspended ( considering all levels with require all fabricataion work and fitiing from RCC slab to false ceiling upto ceilling System with Optra (Bevelled Tegular) Edge Tiles With /approved make 15mm Exposed Grid.The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥85%, Colour White/Black, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW & 74% RW. The tile shall be laid on Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.57 Kgs/M2 with a minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of make.The Tile & Grid system used together should carry a 10 year warranty.INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres.SUSPENSION SYSTEM accessories manufactured. World Industries consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanised spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner.. ( Necessary fabrication with anticorrosive paint work , scaffolding, anchor fasting , bolting hilti or equivalent make with testing certified in scope of contractor). sample mock shall be approved from Architect/Client.work complete as per the instruction of Architect/Client/PMC. Only plan area will be measured for payment any vertical surfaces, drops, cove will included in the same. as per design given by the architect and approved by the engineer in charge
Grid Ceiling: Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled Tegular) Edge Tiles With Armstrong 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on Armstrong Suprafine 38 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 14 Kgs/M2 & minimum pull out strength of 100 Kgs.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. . The Tile & Grid system used together should carry a 30 year warranty. as per design given by the architect and approved by the engineer in charge
Roller Blinds : Providing and fixing blinds as per approved make as per suggested shade & spring drive system with steel ball chain/one touch with speed control action roller blind with end brackets with head rail, components, bottom bar. Fabric : screen classic 5% Fabric value : 465 gsm , Thickness : 0.65 mm Fabric to be as per approved sample. All the work complete as per the detailed drawing , mockup sample and instruction of Architect/EIC.All complete as per approval of designer. The mode of Measurement: The size of the blind will be measured from end to end bracket (Left to Right bracket) height will be measured from top of the pelmet to sill bottom level and clear opening size only there will be not extra payment towered overlapping.& mockup sample approved by the Architect/ EIC. as per design given by the architect and approved by the engineer in charge
Providing and Fixing Armstrong Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architect/ approving engineer, made of a Moisture Resistant fibre board with minimum 595 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 13mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.60. Product should have class 2 fire classification as per BS 476. All certification shall be provided by the manufacturer. The panels shall be mounted on special aluminium splines (keel) using clips provided by Armstrong and as per design given by the architect and approved by the engineer in charge
ELECTRIC - B Internal Wiring Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (d) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (A-1) 4 core 4 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (e) 2 to 4 core 16 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (b) 2 to 4 core 4 Sq. mm
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories.Cat. III
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories.Cat. III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories.Cat. III
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. As desired by Engineer In charge (5) Electronic hum Free four or more steps EME Fan regulator Cat.III
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy & 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing. [ Make shall be approved by Engineer in Charge]
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing.
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with necessary finishing.
Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Bolt & Nuts erected with necessary hook of 10 mm M.S. Round Bar.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box.
Supplying & erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame ABS body with inbuilt lowers & square frame.
WIFI SYSTEM 2-4 GHz & 5-8 GHz (POE) based , controller based, ceiling mounted 5 dbi wide wi-fi point for internet network signal booster
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. As desired by Engineer In charge (8) Modem Jack for Computer Open RJ-45 Cat.III
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction [C] CAT - 6 (FOR WIFI)
Termination of RJ-45 data points & Certification of data points by respected agency
Light Fixtures Supply, Installation, testing and commissioning of recessed mounted down light fixture suitable for 1 X 18 W CFL luminaire along with electronics choke and all other necessary accessories. Eq. to CGL Cat No. LCDE-18-CDL
Supply, Installation, testing and commissioning of recessed mounted down light fixture suitable for 600x600 24W LED square light fixture along with electronics choke and all other necessary accessories. Eq. to CGL Cat No.
Supply, Installation, testing and commissioning of recessed mounted down light fixture suitable for 600x600 36W LED square light fixture along with electronics choke and all other necessary accessories. Eq. to CGL Cat No. LCTLRN-36-FO-CDL
Supply, Installation, testing and commissioning of recessed mounted down light fixture suitable for 600x600 50W LED square light fixture along with electronics choke and all other necessary accessories. Eq. to CGL Cat No. LCTLR-50-FO-CDL
Eco Series (Model No. - 4032) PIR presence detection sensor of range 20.0m dia coverage recessed mounting at height of 2.5 - 3 meter to control 10 A lighting load. Manually programmable for OFF delay time 10 sec - 40 min, Passive photocell Lux Sensing to sense ambient light level. Supply and installation cost for bypass switch/box, conduit and wiring should be included such that in case of failure of sensor should allow light fixture operation by switch. Ref make - Honeywell
Digital type (Model No. - MS 4017) PIR presence detection sensor of range >6.0m dia coverage recessed mounting at height of 2.5 - 3 meter to control 10 A lighting load and additional contactor for AC load control. Manually programmable for OFF delay time 10 sec - 40 min, Passive photocell Lux Sensing to sense ambient light level. Supply and installation cost for bypass switch/box, conduit and wiring should be included such that in case of failure of sensor should allow light fixture operation by switch. Ref make - Honeywell
CCTV Systems Supply, Installation, Testing and Commissioining of 2 MP 1/4" progressive scan CMOS, 1 MP resolutions Dome Camera digital WDR, 3D DNR, IR range, 12V DC +10% ICR, 4MM lense, POE camera. Make: Hikvision - 2CD122P-I3
Supply, Installation, Testing and Commissioining of 2 MP 1/4" progressive scan CMOS, 1 MP resolutions Bullet Camera digital WDR, 3D DNR, IR range, 12V DC +10% ICR, 4MM lense, POE camera. Make: Hikvision - 2CD122P-I3
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction [C] CAT - 6 (FOR CCTV)
Supply of 12 port GIGA POE switch. Netgear.
Supply of 24 port GIGA POE switch. Netgear.
24 port supply of 160 MBPS bit rate input max (up to 8 ch IP video), 2 SATA interfaces, 1U case, 19" Make: Hikvision - DS-7WNI-Q1
8 TB HDD for recording of camera. WD Servelince
4U rack for DVR
Junction box for camera
Supply, Installation, Testing and Connection of 0.9 mm Fiber Optic cable from data switch between buildings laid through raceways/conduits/floor trunks/ground etc. (Rates of raceways/conduits/floor trunks shall be excluded)
Public announcement system Supply, Testing and assembling of 6W recessed mounted speaker with necessary accessories,suitable for indoor applications.
Supply, Testing and assembling of volume controller.
The system should comprise of following items as minimum requirements. Bidder should include any other item required for satisfactory operation of system as per their supply. Supply and laying of the 2c X 0.75 sq mm coper, stranded, shieded cable.
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm
Lift 8 / 10passengers . Ground plus 3 upper floor with Rated Speed of 1.0 m/sec with micro proce/PLC control and ACVVVF. drive, for machine room less - 8 passangers ( extra cost as per annexture 1) OMEGA / TRIO OR EQ.
TIME ATTENDANCE SYSTEM SITC of biometric reader unit with TCP/IP connectivity (thumb impression) for employee attendence with min. 1000 transition capacity.
Supply, Installation, Testing and Commissiong of Time Attendance software (PC based for interfacing and programming) - single user
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction [C] CAT - 6
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm
Providing and fixing air curtain with 21mt/sec air flow of euronics make
ELECTRIC TOTAL SUM - B HVAC - C 4 Way Cassette 2.5 TR VRF Indoor units as 4 way / 2 way / 1 W (Corner) compact Casstte type having galvanized steel plate casing. The unit shall be insulated with sound absorbing thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel flush with the ceiling matching interiors. The unit shall be supplied with direct drive four speed turbo fan, self closing 4 motorized vanes, heat exchanger with Cu Coil and Al fins designed for minimum air flow resistance, insulated drain pan below coil, built in drain pump, drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. The unit shall be complete with pressurized drain pumping mechanism; Compact Cassettes available in Size of 600x600 mm shall be preferred; Balance features as sepcified in Tender
4 Way Cassette 2 TR VRF Indoor units as 4 way / 2 way / 1 W (Corner) compact Casstte type having galvanized steel plate casing. The unit shall be insulated with sound absorbing thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel flush with the ceiling matching interiors. The unit shall be supplied with direct drive four speed turbo fan, self closing 4 motorized vanes, heat exchanger with Cu Coil and Al fins designed for minimum air flow resistance, insulated drain pan below coil, built in drain pump, drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. The unit shall be complete with pressurized drain pumping mechanism; Compact Cassettes available in Size of 600x600 mm shall be preferred; Balance features as sepcified in Tender
Fresh Air Ducting Supply and installation of GI, site fabricated rectangular ducts complying to IS:277 (material withminimum 120 GSM coating) & with TDC/TDF flanges & approved shop layouts, necessary approved make with horizontal trapeeze supports & SS angle based Riser supports complete with Clamps (as directed by site in-charge and as specified) and anchor bolts, supply air collars, guide vanes, splitter dampers, duly painted. Rates to include first dry run for leak detection test including rectification in case of leak; minor civil works including making/breaking of brickwall cutouts as required (Contractor to keep all duct ends covered during installation to prevent ingress of dust and derbis) 24G GI ducting
Ducting Accessories Supply, fabrication, Installation and testing of flexible connections constructed flexible double canvas sleeve in accordance with approved shop drawings for ductables and as per the specifications
Al aerofoil opposed blade Volume control Dampers and PVC Gears for smooth operation for volume control at unit discharge and duct branches
Supply, installation, testing and commissioning of Al Extruded Powder Coated Freshair Grilles with VCD painted in approved shade
Thermal insulation works Thermal insulation of Fresh Air duct with Elastomeric nitrile rubber 40-60 kg/m3 with thermal conditivity < 0.035 W/m°K at an average temperature of 0°C; Fire Propagation compliance as per BS476 Part 6 to meet the Class ‘O’ Fire category (without Al/outer metalic foil); Water vapour permeability shall not exceed 0.017 Perm inch (2.48 x 10-14 Kg/m.s.Pa), applied with Adhesive having VoC value as per IGBC acceptance and the entire process of Application shall be as recommended by Mfr. thickness of insulation as below for duct passing in Non-AC Area above ceiling additionally sealed with 50mm x 3 mm self adhesive NITRILE material tape on top at longitudinal and transverse joints simultaneously; Terrace ambient exposed portion of duct covered with UV protected GC cloth securely pasted over insulation surface 25 mm thick for TFA ducts passing through NonAC Area
200 GSM Glass fibre cloth applied with MFR recommended adhesive on Exposed Insulation for UV/Mechanical protection
OUTDOOR Units Supply, Installation, Testing, Integration, Commissioning with required floor Supports of Compact Air Cooled type Variable Refrigerant Flow Technology outdoor units (designed for cooling / heating modes) as specified; Latest technology Compressors (Inverter or Digital Scroll design), Condenser coil fabricated from Seamless Copper tube & Plate type Al Fins of Multi Row, Axial Flow, upward/side throw condenser fan with motor unit, insulated refrigeration piping; Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Compressor motor Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply and IP 55 protection. Final Configuration brakup of the each ODU modules shall be decided at detailed engineering stage (Total HP remaining same); there shall be no upward revisions in rates on account of same 16 HP Outdoor units designed for integration with the IDUs as per design schedule in configuration
Supply, Installation, Testing, Integration, Commissioning with required floor Supports of Compact Air Cooled type Variable Refrigerant Flow Technology outdoor units (designed for cooling / heating modes) as specified; Latest technology Compressors (Inverter or Digital Scroll design), Condenser coil fabricated from Seamless Copper tube & Plate type Al Fins of Multi Row, Axial Flow, upward/side throw condenser fan with motor unit, insulated refrigeration piping; Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Compressor motor Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply and IP 55 protection. Final Configuration brakup of the each ODU modules shall be decided at detailed engineering stage (Total HP remaining same); there shall be no upward revisions in rates on account of same 14 HP Outdoor units designed for integration with the IDUs as per design schedule in configuration
8 HP TFA System Outdoor units designed for integration with the TFA AHU as per design schedule in configuration
Supply of Imported Branch Distribution Joints for VRF system. ( The Quantity is indicative and shall be included as required by Contractor for their System Requirement at bid stage)
SITC of Seamless heavy gauge Copper piping of following size duly insulated with 13 mm/ 19mm thk. Nitrile Rubber Insulation( As per Specified with K Value of 0.027-0.029 K Cal/Hr.M Deg C at 0-16 Deg C) . Refrigeration piping will have to be taken in the piping rack / Support individually connecting to all indoor units for the respective floors. All necessary supports, fittings, valves & ref. joints and riser fittings where passing via shaft included & where ever required will be included. Exposed piping insulation shall be covered with GC sheet for UV & mechnaical protection; Pipe sizes shall be 1/4";3/8";1/2";5/8"; 3/4"; 7/8"; 1" with 13 mm Thick Insulation; 1 1/8"; 1 1/4"; 1 3/8"; 11/2"; 1 5/8"; 1 3/4"; 1 7/8"; 2" with 19 mm Thick insulation (Sizes as applicable for below Individual circuits) Sizes shall be approved by OEM
For 16 HP Seminar Room VRF System with its associated IDUs (Routing Broadly as per Tender Layout enclosed) including cost of laying on cable tray for pipes running on terrace duly fixtured
For 16 HP Seminar Room VRF System with its associated IDUs (Routing Broadly as per Tender Layout enclosed) including cost of laying on cable tray for pipes running on terrace duly fixtured TFA Unit Refrigerant Piping
For 14 HP Computer Room VRF System with its associated IDUs (Routing Broadly as per Tender Layout enclosed) including cost of laying on cable tray for pipes running on terrace duly fixtured
First charge of Refrigerant R410 / Oil & required consumables complete for all circuits for 16 HP Seminar VRF System
First charge of Refrigerant R410 / Oil & required consumables complete for all circuits for 8 HP SEminar TFA VRF System
First charge of Refrigerant R410 / Oil & required consumables complete for all circuits for 14 HP Computer Room VRF System
Treated Fresh Air Double Skinned AHU Treated Fresh air unit 900 CFM / 50 mm WC Double skinned weather proof unit 43 mm thick PUF eq material AHU complete with Plug Fan / drivepackage / IE-2 motor / duct damper / water proof canvass with zip connection with 6R Deep DX Coil insulated drain pan /vibration isolators/MS base frame 900 CFM Treated Frsh Air Unit
1.5 sq mm 2C shielded non polarity cable (or OEM Manufactured and supplied) Communication Cable between Outdoor Units & Indoor Units laid in Rigid 25 mm PVC conduit with workmanshiplike dressing with proper connectors/clamps complete (Rate to include supply & laying of MS black conduits with due saddling)
VRF System Central Programmable Controller (HMI) designed to control & monitor ODUs and IDUs of this project including complete installation hardware duly programmed and data enriched for providing display of Return Air Temperatures of each VRF treated area / OnOff Trip Status / Command to Turn On/Off individual system as specified; unit shall be provided in wall mouted / table top console cabinet; shall have minimum 200 mm LCD display panel / yearly schedule / power prooprtional distribution function / temperature edit-limitation / history function erected on wall with arrangement to integrate with site fire alarm system Price quoted for Controller shall be for a common centralized controller monitoring/controlling all ODUs of this project and its associated IDUs of this project in a single Unit BEE Approved 3 Star Inverter DX Air Cooled Hiwall Type Split units
Supply installation testing and commissioning of precharged Split units, Split unit shall comprise of indoor unit, Antimould Filter, matching air cooled Inverter Compressor outdoor condensing unit installed on MS painted Frame and vibro-isolators, complete with wired remote control having 5 rmt lead wire; scope to include 10-16A wall mounting MCB, accessories, fixtures on riser pipes in shaft upto terrace; seasoned wood palmet framing on wall for IDU 1.5 TR Inverter split unit
Supply installation testing and commissioning of precharged Split units, Split unit shall comprise of indoor unit, Antimould Filter, matching air cooled Inverter Compressor outdoor condensing unit installed on MS painted Frame and vibro-isolators, complete with wired remote control having 5 rmt lead wire; scope to include 10-16A wall mounting MCB, accessories, fixtures on riser pipes in shaft upto terrace; seasoned wood palmet framing on wall for IDU 2.0 TR Inverter split unit
Copper refrigerant piping insulated with Nitrile Rubber insulation & further covered with GC sheet for UV/mechanical barrier including end to end Control cabling between Indoor and Outdoor units; Piping shall be laid on GI perforated Cable tray/cable ties supported on terrace floor & shaft risers with MS painted clamps for 1.5 TR Split unit
Refrigerant Piping as above for 2 TR Split Unit
Condensate Drain Pump syphon based technology complete with flex piping, tank storage, fixtures accessories
CPVC drain pipe with 6mm nitrile insulation using Mfr recommended adhesives at Joints for Coil Condensate as specified with all required connectors, couplings, drain trap, required bend and fittings, vertically terminated to nearest draip point with adequate slope and supporting and routed as per layout – RMT rates shall include supporting materials/fixtures with drain up down stream side covered with GC Fibre for UV/Mechanical protection 25 mm NB
Flexible Insulated Fibreglass Ducting with supporting hangers and special clipping system 150 mm dia
100 mm dia
080 mm dia
Electrical Works VRF ODU Panel 1 for Seminar Hall: 14G IP56 protected Terrace mount weather proof painted Power Distribution Board with isolator / incomer provision 1 nos. 16 HP & 1 No. 8 HP / 1.5 kW TFA Unit Motor outgoing feeders
VRF ODU Panel 2 for Computer Room: 14G IP56 protected Terrace mount weather proof painted Power Distribution Board with isolator / incomer provision 1 nos. 14 HP Unit Motor outgoing feeders
ODU Breakup as Outgoing feeders is indicative only; final O/G ODU break-up rating and Quantity shall be finally prescribed based on detailed engineering for ODU to meet intended diversities on floor to floor basis at no extra cost; SLD with ratings for the PDB supplied shall be submited by contractor for approval before supply Power Cabling for ODU Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable. 3C X 4MM2
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable. 4C X 16MM2
Supply Installation laying on Cable trays including Ties and fixtures of Flexible FRLS Copper Wire 12 SWG duly insulated for earthing (E)
25x3 MM GI Strip Earthing
Cable Tray Providing and fixing approved make Perforated C type cable tray. Made from CR sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. 150 X 50 X 1.5 mm Thick TOTAL HVAC SYSTEM COST AS PER SCOPE DEFINED WITH 1 YEAR GUARANTEE (DLP) PERIOD Lot items where mentioned shall not be measurable and shall be treated as single lot only MAINTENANCE CONTRACT
Comprehensive Maintenenace Contract including complete materials as required / specified excluding taxes. 1st year after completion of 1 year of DLP
2nd Year =do=
3rd Year =do=
EARTH WORK HVAC TOTAL SUM - C CIVIL - D Excavation for foundation upto1.50 MT depth including sorting out and stacking of useful materials and disposing the excavated stuff up to 50 mt lead ( A ) loose or Soft Soil
Excavation for foundation up to 1.50 MT depth including sorting out and stacking of useful materials and disposing the excaveted stuff upto 50 mt lead (B) Dense or hard soil
CEMENT CONCRETE Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg ) (a) Foundations, footings Bases of columns and the like and Mass concrete.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg ): Columns, pillars, posts and struts up to floor two level. Up to Ground level
Providing and laying cement concrete 1:4:8 (1cement : 4 coarse sand : 8 hand broken stone aggregates 40 mm. nominal size) and curing complete excluding cost of form work in :(a) Foundation and plinth
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg ) (c) Beams, girders and cantilever up to floor For plinth beams
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg )(B) Walls, from top of foundation level upto floor two level
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg ) (c) Beams,Lintels girders and cantilever For basement, ground floor and first floor
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450kg) slab basement,ground floor and first floor
FORMWORK providing and formwork of ordinary timber planking so as give a rough finish including cenering, shuttering and propping etc. height of propping and centering below supprting floor to ceiling not exceeding 4 mt and removal of the same for in sity reinforced concrete and plinth concrate work in (A) Foundations, footing base of column etc. , and mass concrete.
providing and formwork of ordinary timber planking so as give a rough finish including cenering, shuttering and propping etc. height of propping and centering below supprting floor to ceiling not exceeding 4 mt and removal of the same for in sity reinforced concrete and plinth concrate work in (B) flat surface such as soffits of slab, landings and the like (1) floor etc. up to 200 mm in thickness.
providing and formwork of ordinary timber planking so as give a rough finish including cenering, shuttering and propping etc. height of propping and centering below supprting floor to ceiling not exceeding 4 mt and removal of the same for in sity reinforced concrete and plinth concrate work in (C) vertical surface such as wall (any thickness) partitions.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth.
providing and formwork of ordinary timber planking so as give a rough finish including cenering, shuttering and propping etc. height of propping and centering below supprting floor to ceiling not exceeding 4 mt and removal of the same for in sity reinforced concrete and plinth concrate work in (G) column pillars, post and strust. (1) square , rectangular, polygonal in plan
REINFORCEMENT Providing and fixing TMT FE - 500D (Ductile) steel bars reinforcement for rcc work confirming to IS 1789-2008 and of tested quality of TATA, SAIL, JINDAL, ELECTOTHERM or equivalent make including bending, binding and placing in position as per the drawing and instruction of Engineer-in-charge etc completeup for ground floor and first floor
BRICK WORK Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B) Conventional
Providing and fixing masonary work with AAC (autoclaved aerated concrete) blocks 0.23 mt wide, with minimum compressive strength of 3 N/mm2, density of around 575 kg/cu mt and fixing them with ultratech fixobond jointing mortar etc complete as per the instruction given by engineer-in-charge for ground and first floor
DOOR WINDOW Providing and fixing in position partly fixed and partly openable door with single / double shutter and made with standard extruded anodised hollow section of size 100 x 38 mm frame of approved shade and filled with indian wood and shutter made of 35 mm thick water proof flush door of greenlam, everest, kitply or equivalent make with 1 mm thick laminate of royal touche, greenlam, euro or equivalent make of any shade on both the sides with necessary hardware of high grade anticorrosive AISI 316 matt stainless steel of kich or equivalent make like handle (200 mm), dead lock, door stop, stopper, hinges with necessary adhesive (fevicol) with all labour etc complete as per the drawing provided by the architect
Providing and fixing aluminum window, partially openable / partially fixed glass window using main frame jindal #8462, 0.526 kg/m, # 8464, 0.764 kg/m,shutter frame of jindal 8463, 0.760 kg/m and clip, section jindal 8461, 0.286 kg/m with silicon packing & rubber gasket with 5 mm thick toughened glass in shutter and 5mm clear glass (modi float, saint gobain, asahi or eq.) and Imax top hung hinges and AISI 316 GRADE stainless steel handles of KICH or eq., hocking arrangement complete with fixing {VENTILATOR)
PLASTER providing 15mm thick cement plaster in single coat on fair side of brick / concrete wall for interior plastering up to floor two level finished even and smooth in C M 1:4 ( 1 cement 4 coarse sand) including finishing with a flouting coat of neat cement slurry with Niru finish complete. For ground floor and first floor
providing 10mm the cement plaster on ceiling in single coat on fair side of brick / concrete wall for interior plastering up to floor two level finished even and smooth in C M 1:4 ( 1 cement 4 coarse sand) including finishing with a floating coat of neat cement slurry with Niru finish complete. For ceiling ground floor and first floor
20 mm thick sand faced cement plaster on walls upto height 10 meters above ground level consisting of 12 mm thick backing coat of C.M. 1:3 (1-cement: 3-sand) and 8 mm thick finishing coat of C.M. 1:1 (1-cement: 1-sand) etc. complete including all material and labour as directed by Engineer in charge
Providing and applying Stonecrete plaster or equivalent of average thickness 18 mm consisting of 15 mm thick smooth mala plaster in cement mortar 1:3 (1 cement : 3 fine sand), with necessary grooves, curing etc complete for all heights as per the pattern given by the architect and as instructed by the engineer-in-charge
Providing and fixing dry Baleshwar stone clading of minimum 25 mm thickness on wall surface over 15 mm thick cement plaster 1:3 (1 cement : 3 sand) with all grooves and pattern for any size andand fixing the stone with required clamp and grouting it with hilti chemical or equivalent. and filling the grooves with cement grout and as per all the specifications and design given by the Architect and directed by the Engineer-in-charge
FLOORING Providing and laying polished kota stone slab 25mm thick in risers of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. as per the pattern provided by the architect
providing and laying 24" x 24" double glazed vitrifed 8mm thick tiles of approved make, clour and pattern for flooring over 20mm (Average ) base of cement mortar 1:6 (1-cement : 6 coarse sand ) on new surface or fixing on existing flooring by adhesive materials including dismentalling of existing flooring and jointed with colour cement slurry including finished with flush pointing and celaning the surface etc. complete for Light shade
Providing and laying glazed tiles 300 mm x 450/600 mm 6 mm thick in skirting, risers of steps and dado on 10 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with white cement slurry
Providing cement vata (10 cm X 10 cm size) quarter round in Cement Mortar 1:1 including neat cement finishing, watering etc complete
Providing and fixing mirrror polished KANDLA GREY cladding on openings of width 125 mm and thickness minimum 20 mm with top and both exposed edge polished and joining with chemical adhesives of bal, weber or equivalent make after driving holes in stone at 500 mm c/c and screwing and fixing with araldite as per the drawing and as per approved by the Architect.
Providing and fixing storage shelf made from all sides polished kota stone of minimum 25 mm thickness for vertical and horizontal members fixed at about 1.00 mt c/c horizontal distance and about 0.40 mt c/c vertical distance including all labour, cement, groove in wall, kota for fixing, machines etc complete as per the instruction given by the Engineer-in-charge and design given by the Architect
GRILL Providing & fixing M.S. grill for window of required pattern to wooden frames of windows/ brick masonry with necessary M.S. angle, M.S. pipe, M.S. flats and other structural steel at required spacing and frame around square or round bars with round headed bolts and nuts or by screws including cutting welding and fabrications etc. complete as directed, grills design and pattern approved by this office . ( B ) Plain Grill
PAINTING Wall painting (three coats) with one coat of BIRLA WHITE primer & BIRLA WHITE putty & with plastic emulsion paint of Asain royale, ICI velvet touch brand, Berger , Nerolac or equivalent and manufacture on wall surfaces to give an even shade including thouroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
Wall painting (three coats) with one coat of BIRLA WHITE primer & BIRLA WHITE putty & two coats of plastic emulsion paint of Asain royale, ICI velvet touch brand, Berger , Nerolac or equivalent and manufacture on wall surfaces to give an even brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. On ceiling and sloping roofs
Finishing wall with 100 % weather proof paint of Asain - Apex ultima, ICI - Weathershield Max make on wall surface in 2 coats over 1 coat of primer of Asian, ICI make of required shape and even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete
MISCELLANEOUS Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar.
Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work
Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.
providing and drilling various All (rebaring) diameter various mm. depth and fixing various diameter of steel bar with appoxi mortar hilty HY150 or equivivalent with required materials, drilling machine, tools, laboures etc complete. As per the instruction given by the engineer-in-charge
Providing and Core cutting work of various diameter and various size depth with required corecating drill machine, fastners tools, labour and supervision etc complete.
Providing and fixing 60 x 60 cm RIVER FINISHED KOTAH stone 25mm thick flooring of even grade with 100mm high skirting of the same over 20 mm (Average) thick base of cement mortar 1:6 ( 1 cement: 6 coarse sand or L M 1:1.5 laid over and as per approved byt the Architect
Providing and applying anticarrasive treatment with polymer base materials to the steel rainfarcement including descaling the dust and applying the preventive coating of approved make (for the R.C.C. structures near coastal area only) etc complete.
Providing Material and Labour Providing and constructing of 0.80 mt high sandwich type cooking platform made from telephone black granite stone top slab of mimium 18 mm thickness, 25 mm thick both sides polished kota stone horizontal and vertical members, telephone black granite facia with flat edge, 450 X 400 X 165 mm size stainless - steel sink of nirali make including cement, sand, chemical - araldite including all labour, fixing, cutting holes etc. complete. as per drawing given by the Architect and instruction given by Engineer in charge.
CIVIL TOTAL SUM - D Structured Networking system for Approx. 115 Data & 35 Wifi Nodes Unloaded Jack Panel, 24 port, 1U
Cat 6 UTP Single Jack I/O
Cat6 UTP Patch Cords - 1mtr ,LSZH
Cat6 UTP Patch Cords -2mtr LSZH
Dual port faceplate
Surface Mount box
Ethernet switches ( Non - POE ) 48 port 1000Mbps , Min. 2 SFP Slots , Managed , Layer 2 switch
24 port 1000Mbps , Min. 2 SFP Slots , Managed , Layer 2 switch
08 port 1000Mbps , Min. 2 SFP Slots , Managed , Layer 2 switch
1 Gig Single mode SFP Module
Ethernet switches (POE ) For Access Point 24 port 1000Mbps POE , Min. 2 SFP Slots , Managed , Layer 2 switch
08 port 1000Mbps POE , Min. 2 SFP Slots , Managed , Layer 2 switch
NETWORKING SYSTEM TOTAL SUM - E Providing & Supplying BenQ Interactive Flat panel solution of screen size 65 inch, panel type interactive , IPS, TUV certified Flicker free Display, 10 W Blue Light, 6 star Energy , ROHs compliant resolution (pixel) UHD 3840 X 2160 , Brightness 450 nits, contrast ratio 1200 :1, Max Response time (ms) 6 ms or faster, light life 30,000 hrs., panel Bit 10 bit, maximum watt 180 w, stand by watt <0.5w, Technology IR, Touch points android 10 or more & window 20 or more touch response time <15ms/8ms, Touch Accuracy ± 1.0mm, Touch output USB type B, Tempered glass 4mmth , 7H, Internal Speaker 20 W x 2 or higher VGA input , HDMI input (2.0x4) or more with MHL, HDMI output, PC Audio input 3.5mm, line out 3.5mm, RJ 45 port, USB (Type A), USB (Type B), RS 232 input, power switch in built, pen tray in Built, Remote controller, styles 2 or more with in built ambient light sensor, Total turn on time, Internal Temperature Sensor, freeze /blank Screen , any where annotation tool, WPS (Office viewer App), Annotation application in built and free of android, windows or mac as required, wireless 2 way mirroring & collaboration support as directed by Engineer in charge.
Concept Creator
SRISHTI ENTERPRISES
Mahendra and Co
BUCON ENGINEERS AND INFRASTRUCTURE PVT. LTD.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid