Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹1.6 Cr AT PO RAMPUR DUMRA P MARANCHI PATNA 803301 | ₹1.6 Cr |
Tender Value
₹1.8 Cr
EMD Value
₹1.8 L
Closing Date
15 Nov 2023, 11:00 amClosed
Package No. SAM-010-NHM, Construction of Integrated Public Health Lab (IPHL) at DHH Sambalpur, Odisha
NBCC/ODISHA/SBG/NHM/NIT/23-24/63
NBCC/ODISHA/SBG/NHM/NIT/23-24/63
Open Tender-Domestic
Civil Works General
Sambalpur, Odisha
₹11,800
₹1.8 L
8 Jan 2024
31 Oct 2023
15 Nov 2023
15 Nov 2023
24 Nov 2023
5 Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand : 8 stone agregate
40mm nominal size) as levelling course in floor and plinth including tempering, curring, Cum 108.21 4140.40 448053.00
shuttering etc. complete all depth and height.
6 Providing and laying plain cement concrete 1:2:4 (1 cement: 2 sand: 4 stone
aggregate 12mm nominal size) as levelling course in foundation and plinth etc.
including tempering, curring, shuttering etc.complete all depth and height.
Ground Floor Cum 37.69 5853.70 220644.73
7 First class Fly ash Brick masonry using bricks of size 25 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with
ordinary Portland slag cement(PSC) and screened & washed sand for mortar after
immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth
including splays cutting, circular moulding, corbelling, chamfering and similar such type
of works, watering and curing etc. including cost, conveyance, loading, unloading,
royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required
for the works etc. complete in all respect as directed by the Engineer-in-Charge.
8 Fly Ash. brick masonry of size 25 cm. x 12 cm. x 8 cm. having crushing strength not
less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade
cement and screened & washed sand for mortar after immersing the bricks for 6 (Six)
hours in water before use in Superstructure including splays cutting, circular
moulding, corbelling, chamfering and similar such type of works, watering and curing
etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials,
cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all
respect as directed by the Engineer-in-charge
Ground floor Cum 116.95 4344.00 508046.37
Terrace floor Cum 30.72 4942.90 151868.27
9 Half brick work with Fly Ash brick masonry in cement mortar (1:4) in super structure
having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular moulding chamfering and corbelling and similar
such type of works with all necessary projections watering and curing after immersing
the bricks in water at least for six hours before use including cost, conveyance, royalties
and taxes of all materials with all labour,labour cess and T & P required for the work
complete in all respect as per direction of Engineer-in-Charge.
Ground floor Cum 14.05 4540.60 63789.43
10 Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per
approved designs and drawings having a minimum compressive strength (in work test)
250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken
granite stone chips and screened and washed sharp sand for mortar of approved quality
from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % )
to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting,
lowering, laying and compaction concrete by using vibrators, watering and curing for 28
days, centering and shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing grooves or beads wherever
necessary including cost, conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the work etc. complete in
all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of
M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting,
bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
b) Column up to plinth Cum 19.06 11132.40 212162.54
c) Plinth Beam Cum 19.20 5519.40 105988.10
d) Column above plinth Cum 16.10 11132.40 179198.03
e) Column up to Roof Beam Lvl. :- Cum 13.93 12451.000 173395.45
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
e) Column up to Roof Beam Lvl. :- Cum 5.90 14029.000 82771.10
11 Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL
(VIZAG) make including bending, binding, welding and joining if necessary and tying
the grills and placing in position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or
tor steel and binding wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors (Linear measurement will be taken and
quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor
steel only. Wastage if any, including weight of binding wire will not be considered for
measurement) etc. complete as per specification & direction of Engineer-in-charge.
Ground floor Qntl 354.97 8765.70 3111547.30
Terrace Floor Qntl 17.43 8816.70 153631.33
12 12mm cement plaster to out side of brick surfaces with cement mortar of mix 1:6 (1
cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all
floors and all heights.
Ground floor Sqm 142.98 145.30 20775.05
Terrace floor Sqm 249.64 157.10 39217.94
13 16mm cement plaster to inside of brick surfaces with cement mortar of mix 1:6 (1
cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all
floors and all heights.
Ground floor Sqm 1099.72 207.60 228300.93
Terrace floor Sqm 33.95 218.00 7401.72
14 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with
cement mortar of mix 1:4 (1 cement : 4 coarse sand) including necessary scaffolding,
curing etc. all complete at all floors and all heights.
Ground floor Sqm 259.23 161.20 41788.30
Terrace floor Sqm 12.89 169.40 2183.73
15 Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of
approved make in floors laid on 20 mm thick cement mortar (1:4) (1 cement :
4 course sand) and filling joints with slurry including cost of all materials, labour T&P
etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-
Ground floor Sqm 25.65 2202.60 56492.95
16 Supplying, fitting & fixing of Granite Tiles of minimum Above 0.10 Sqm & up to 0.4 sqm
(10mm. thick) of approved make in dadoes laid on 12 mm thick cement mortar (1:3)
(1 cement : 3 course sand) and filling joints with slurry including cost of all materials,
labour T&P etc. required for the work all complete incl. rubbing as per direction of the
Engineer-in-charge.
Ground floor Sqm 28.97 1621.80 46976.51
17 Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm Glaze vertified
floor tiles of matt finish with veilcraft (VC ) shield( Scratch free/stain free) with water
absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B
Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling
joints with white cement of approved quality including cost of all materials, labour T&P
etc. required for the work all complete as per direction of the Engineer-in-charge.
Ground floor Sqm 231.46 1217.70 281846.54
18 Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm Glaze vertified
floor tiles of matt finish with veilcraft (VC ) shield( Scratch free/stain free) with water
absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B
Ib). laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with
slurry mixed with pigment to match the shades of the tiles etc. complete including cost
of all materials, labour T&P etc. required for the work all complete as per direction of the
Engineer-in-charge.
Ground floor Sqm 32.29 1322.10 42696.10
19 Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring in toilets using
Digital matching anti-skid ceramic floor tile (having minimum thickness 7 mm to 8 mm
& size 300 mm x 300 mm ) confirming to I.S 13755 of approved quility and shade on
20mm thick ded of cement morter of mix (1:4) laid in proper slope and gradient with
screened & washed sharp river sand for mortar and grouted with neat white cement
slurry, joining the anti-skid ceramic floor tiles with neat white cement slurry, mixed with
required (tiles are to be immersed in the water for required time before use) quantities
of pigments of approved marks to match the shades of the anti-skid ceramic floor tiles if
required including cost, conveyance, loading, unloading, stacking, royalties of all
material, cost of all labour , sundries, T&P required for the work , watering,complete in
all respect as per specification excluding GST aas per specification as directed by
Engineer-in-charge
Ground floor Sqm 27.77 1017.90 28271.69
20 Supplying, fitting & fixing of 300mm x 600mm Germ free Glaze Ceramic wall tiles
having thickness 6.5mm to 7.0 mm confirming to IS 13753 in dadoes, skirting
and risers of steps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course
sand) jointed with slurry mixed with pigment to match the shades of the tiles etc.
complete including cost of all materials, labour T&P etc. required for the work all
complete as per direction of the Engineer-in-charge
Ground floor Sqm 80.65 1240.80 100070.52
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
21 Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm
thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry
including cost of all materials, labour T&P etc required for the work all complete as per
direction of the Engineer-in-charge
Ground floor Sqm 22.34 498.60 11139.76
22 Providing and fixing seasoned sal wood work in frames at any locations including doors,
windows,cupboard, clerestory and other frames fixing in position including cost of
hinges, M.S. flat (30mm x 6mm) hold fasts lugs or dash fasteners of required dia and
length as per drawing / specification, at all floors and all heights.
Ground floor Cum 0.18 53421.80 9515.13
23 Factory made 30mm/32mm flush door shutter (Laminates both side of frame) with all
labour, iron fittings, and wooden hinged cleats etc fitted and fixed complete in all
Ground floor Sqm 33.35 3617.30 120636.96
24 Supplying and fixing of Anodisied 15 microns / Powder coated 50-60 microns approved
colour aluminium 50mm Casement series door cum fixed Unit with suitable
aluminium extrued profiles. the system should design to accommadate 5mm clear
Toughen glass 50% and 50% 4MM ACP. the rate inclusive of hardwares like
antilift,roller, espag lock cum handle,epdm gaskets, felt along with all accessories etc
complete. the gap between the wall and window will be filled with silicon weather
sealent in the outer side.Casement Door Outer frame ( 50*46 mm SERIES) Sash - 78.5
* 58 mm ) + Mullion 66 * 50mm + Beeding 35.5 *25.5 mm) Make - WINPLUS+ /
Ground floor Sqm 7.97 8999.00 71727.12
25 Factory made FRP( Altematly called GRP) door frame of size 75mm x 100mm
fabricated using E - glass chopped strand mat (CSM) U.V stabilised inopathalic Gel coat
and impregnated with inopathalic resin The thickness of the GRP skins shall not be less
then 2.0 mm . The door frame consists of four segments which are provided with plug in
socket arrrangement in-situ-in mould. The segments are plugged in and are joined
together by means of srew. The GRP frame shall be provided with wooden reinforcement
on six locations for high srew holding capacity for fixing metalic hold fast and shall be
consolidated by filling with medium density foam / plaster of paris with fibre
reinforcement , six number of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast
shall be provided with the frame. The material and process for manufacturing the finish
of door frame shall conform to RV-TIFAC composites Design centre's standards and
specifications . The finish of door frame will be plain colour white /Ivory/Beige/Light
grey / Golden brown / Mahogany/ Teak wood /sand stone Champagne/Pastel blue or any
other colour using high quality pigment complete in all respect as per specification and
direction of the Engineer in Charge. etc. complete
26 Factory made GIRID FRP or called GRP sandwich composite door shutter of 32mm thick
laminated with two GRP skin with good grain finish fabricated using UV stabilised
isoppthalic gel coat and one layer of 450 gsm E-glass chopped strand mat (CSM)
impregnated with ortopathilic resin The thickness of the skins shall not be less than
1.50mm . Expanded polysryne ( EPS) structural foam panel of 29 mm tickness and a
density of 20kg/cu.mts shall be used as core material wooden reinforcements made of
sesasoned sal wood block of cross section not less than 28mm x 32mm and also
necessary sal wood reinforcements for fitting the metal fittings such as lower bolts
,aldrops, handles etc. shall be provided . A structural adhesive compatible with
(EPS)foam shall be used for bending the core material. the sal wood reinforcements and
the skin The material and process for manufactuing te door shutter shall conform to RV -
TIFAC components design centre's standards and specification and the door shutters
tested in conformation to IS 4020-1998. The Finish of door shutter will be plain colour
as per specification and direction of the Engineer in Charge. etc. complete
27 Providing and fixing factory made 2.5 track KOMMERLING uPVC white colour sliding
window with bugmesh comprising of uPVC multi-chambered frame having section Frame
88mm x 49mm, Window sash: 37mm x 61mm, Bugmesh sash: 58mm x 32mm made
out of lead free green profiles with corners fusion welded, fully reinforced with
Galvanized steel 1.5 mm. The windows profile should fulfill the requirements of Viny
2010. The physical properties of the profiles like Vicat softening temperature, density,
tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity
should be tested in accordance with ASTM/DIN-ISO standards and the thermal
conductivity as per IS standards. The window comprising of uPVC extruded glazing
beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing
frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws
etc. After fixing frame the gap between frame and adjacent finished wall shall be filled
with weather proof silicon sealant over backer rod of required size. The sash will be
fitted with 5mm clear glass ( Toughen ). Make - KOMMERLING / FENESTA / RIHAU
Ground floor Sqm 30.71 8611.00 264443.81
Terrace floor Sqm 2.33 8611.00 20034.39
28 Supplying and Fixing of M.S. Grills, M.S.Doors, M.S. Gate etc including
cost,conveyance of all materials,priming,and labour for fitting fixing etc.complete as per
the instruction of Engineer-in-Charge
Ground floor Kg 876.09 120.00 105131.32
Terrace floor Kg 122.73 120.00 14727.74
29 Priming one coat with wall cement primer (water bound) to make an even finished
surface in all floors and heights to wall surface of approved make and shade including
sand papering, applying putty wherever necessary & cost of scaffolding, staging charges
with cost, conveyance, taxes of all materials, cost of all labour,labour cess T&P etc.
complete as per the direction of the Engineer-in-charge.
Ground floor Sqm 1501.93 62.80 94321.11
Terrace floor Sqm 296.48 65.90 19538.07
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
30 Painting two coats with approved anti-fungal weather seal paints (ISI) of approved
colour, shade on wall surface over a coat of wall primer(ISI) water bound including sand
papering, polishing the surface, cost, conveyances of all materials and cost of all
labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-
Ground floor Sqm 142.98 77.00 11009.49
Terrace floor Sqm 249.64 82.70 20644.96
31 Finishing plastered surfaces of walls with cement based wall putty (Water based) of
approved make and finishing the surface smooth and even by sand papering to receive
painting in walls, at all heights with staging wherever necessary with cost, conveyance,
taxes of all materials, cost of all labour,labourcess, all T&P etc. required for the work
complete in all respect as per the direction of the Engineer-in-charge.
Ground floor Sqm 1401.26 68.60 96126.44
Terrace floor Sqm 296.48 68.60 20338.57
32 Painting two coats with approved plastic emulsion paint over a coat of wall primer of
make Dulux / Berger / Asian to inside surface of walls finished with Acrylic Wall putty
(water based) of make (Birla / JK) and finished smooth & even surface to receive
painting using roller to the final coat including cost of scaffolding staging charges with
cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc.
complete for all floors as per specification & direction of the Engineer-in-charge.
Note :- Sample of Paint & Primer shall be approved before procurement and use.
Ground floor Sqm 1158.95 83.50 96772.33
Terrace floor Sqm 46.84 86.90 4070.72
33 Painting two coats with approved Enamel Paint on wood work over a coat of Wood
Primer in Ground Floor
Ground floor Sqm 50.36 204.20 10283.82
34 Painting two coats with approved Enamel Paint on Steel work in Ground Floor
Ground floor Sqm 46.85 143.20 6709.62
Terrace floor Sqm 2.39 150.50 360.21
35 Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm
dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @
0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows
in stair case as per approved design and specification, buffing, polishing etc with cost,
conveyance, taxes, all materials, labour, T&P etc. required for the complete in all
Ground floor Kg 70.98 290.30 20604.95
36 2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard
granite crusher broken chips on new work in Ground Floor
Terrace floor Sqm 271.48 361.50 98140.02
TOTAL AMOUNT OF CIVIL WORKS 1,35,52,163.85
TOTAL AMOUNT OF CIVIL WORKS 1,35,52,163.85
1 Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china
water closet (European pattern) with seat cover (solid) and Cistern of approved make in
all floor including supply of sutaible bracket, PVC wall plug and Brass screws etc. all NOS 9.00 6070.86 54637.78
complete including cost, taxes and conveyance as per specification all complete as per
direction of Engineer-in-charge.
2 Supply all materials and labour for fitting and fixing of following size white glazed
vitreous china Under counter wash hand basin of approved make in all floor of approved
quality including cutting the walls & floor and making good the damages with cement NOS 4.00 5449.83 21799.32
concrete etc. including all taxes, duties, transportation etc. all complete as per direction
3 Supply all materials and labour for fitting and fixing of following size Half Pedestal wash
hand basin of approved make in all floor of approved quality including cutting the walls
& floor and making good the damages with cement concrete etc. including all taxes, NOS 3.00 6444.81 19334.42
duties, transportation etc. all complete as per direction of EIC.
4 Supplying all materials, labour, T&P and fixing with labour ,T&P as per specification , the
following Brass/ CP (Hindware) / G.M. fittings at appropriate locations to thr pipe lines at
all floors and at all heights, of approved make confirming to relevent IS specification .
etc complete in all respect.
(a) Health Faucet ABS SS braided hose 1.2 m with CP hook. NOS 9.00 2149.02 19341.14
(b) Two-way Bibcock with wall Flange.
15 mm nominal bore NOS 9.00 2766.16 24895.40
(c) 15mm dia pillar cock . NOS 7.00 2589.16 18124.09
(d) 15mm dia Angle Stop cock with Wall Flange. NOS 18.00 1768.82
Jaquar/Hindware)
(e) 15mm dia Concealed Stop cock with Wall Flange. NOS 3.00 1321.72 3965.15 )
( Make: Hindware/Jaquar
(f) Providing and fixing 700x500 mm beveled edge mirror of superior glass (of approved
quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.
brass screws and washers
Rectangular shape 700x500 mm NOS 7.00 1835.49 12848.43
(g) C.P. Soap Dish holder. NOS 11.00 1821.33 20034.63
(h) 32 mm C.P. Bottle Trap 32mm with 250 & 190 mm Long Wall Connection pipe & wall
Flange (As per Cat no.-ALD-769L250X190 of No. 7.00 2183.00 15281.00
Jaquar) (Make: Jaquar/Hindware)
(i) 32mm dia C.P.waste coupling 32mm SS (Full Threaded) No. 7.00 649.00 4543.00
(j) Providing and fixing towel ring 178 mm dia with brackets fixed to wooden cleats with CP
brass screws with concealed fittings arrangement of approved quality. No. 5.00 2047.30 10236.50
5 Fitting and fixing Water purifier for drinking (with rate of recovery ratio more than 60-
65%). water inlet and drain out connections complete in all respects similar to NOS 2.00 177000.00 354000.00
Aquaguard or similar approved make - (Make - Ion Exchange)in each floor.
6 Floor drain 160x160 mm dia stainless steel grating NOS 12.00 274.11 3289.37
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
7 Supplying all materials, labour & T&P for fitting and fixing of following sizes of white
glazed vitreous china flat back half stall urinal basin confirming to specification of
approved make as per IS-2556 with ISI mark in all floor along with supply & fixing of
necessary component parts like pair of C.I./M.S. bracket including connection from
water supply pipe with all taxes, duties, transportation etc. all complete as per
specification & direction of the Engineer-in-charge.
a) Flat back half stall urinal . (male urinal) Set 2.83 14460.78 40926.74
8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes IS 15778,SDR-13.50
having thermal stability for hot & cold water supply, including all CPVC plain & brass
threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting
chases and making good the same including testing of joints complete as per direction
of Engineer in Charge.
20mm dia CPVC Pipe
Ground Floor meter 9.43 343.97 3245.00
1st Floor meter 9.43 352.23 3322.92
25mm dia CPVC Pipe 0.00 0.00 0.00
Ground Floor meter 5.66 434.95 2461.97
1st Floor meter 5.66 444.39 2515.40
32mm dia CPVC Pipe 0.00 0.00 0.00
Ground Floor meter 20.75 686.76 14253.51
9 Supply, Fixing, jointing, testing and commissioning of uPVC SWR pipe type B (SWR)
pipes(SCH-80) for Soil - waste & Kitchen waste pipe cut to required lengths including
all necessary fittings and specials such as bends, junctions offsets, access pieces.
100mm dia UPVC Pipe RM 47.17 766.53 36156.98
75mm dia UPVC Pipe RM 49.06 515.78 25302.32
10 Supplying all materials,labour and T&P for fitting and fixing of following dia UPVC Rain
water pipes and fittings along with fixing to wall complete in all respect.
(i) 100 mm diameter. meter 14.15 766.53 10847.09
12 Providing, fixing, jointing and testing PP mineral filled low noise level Soil & Waste
piping system as per BS EN 1451, SN4-S16, with minimum density for pipes and fittings
1.4 gm/cm3. Pipes and fittings made from Polypropylene-M (mineral reinforced) and
available from 50 – 160 mm with push fit SBR type rubber ring sockets for easy
installation. Pipes should have 3 layer design. Should have hot water resistance up 95ºC
for short term loading (90ºC for long term loading). Piping system should have chemical
resistance of pH 2-12. Fittings should have swept design from 75-160mm and depth
gauge for proper fittings against thermal expansion and contraction, should have top
marking at every 15° intervals in angular rotation for better alignment. Piping system
includes all required fittings & accessories such as coupler, bend, tee, Y, reducer, access
pipe, multi floor traps, Nahni trap with extension piece etc. for conveying soil, waste &
rainwater purpose in floors, ceiling suspended, or on walls, with leak proof joints etc.
Setting the pipe in 1:2:4 CC in case of concealed plumbing, wall chasing, holes,
supporting, clamping, covering back with chicken mesh & plaster and making the wall
good as per approved shop drawing. Testing as per tender specifications/EIC.
13 Providing all materials, labour, T&P for fitting & fixing of following Bronze Ball Valves
confirming to IS-778 with ISI mark in all floor & fixing with the pipes after cutting the
pipes to required shape & size including wastage etc. of following nominal diameter, all
complete including testing the joints with required water pressure.The cost inclusive of
all taxes,duties,transportation scaffolding etc. all complete as per specification and
direction of Engineer-in-charge..
a) 25mm dia ball valve No. 5.66 583.86 3304.89
b) 32mm dia ball valve No. 3.77 932.67 3519.52
14 Providing all materials labour, T&P for making grooves in bricks/stone masonary walls
vertically or horizontally up to required depth and width in all floor for laying of pipes
and fittings up to 50mm dia, testing the joints with required water pressure and making
good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and Mtr. 28.30 187.97 5320.02
finished smooth with cement morter (1:4) to original shape including cost of materials,
curing, conveyance, taxes of all materials etc. all complete as per specification &
direction of EIC.
15 Providing all labour,T&P for cutting holes in bricks or stone masonry wall for taking
pipes in all floors and making good the damages with cement concrete 1:2:4 finished
smooth with CP 1:4 to original shape including cost of all materials, curing,
conveyance, taxes, duties etc. all complete as per specification & direction of Engineer-
a) For 25mm to 110mm dia pipe to pass in 250mm thick wall No. 30.00 53.34 1600.08
16 Providing all labour,T&P and cutting holes in RCC chajja/roof/floor for taking pipes
through and making good the damages with supply of all required materials etc. No. 15.00 189.51 2842.62
complete as per the direction of the Engineer-in-charge.
17 Square Gully trap 110mm (IP) No. 5.00 807.12 4035.60
1 Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting
out the excavated soil, and then returning the soil as required, in layers not exceeding
20 cm in depth, including consolidating each deposited layer by ramming, watering, etc.
and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of
Pipes, cables etc, not exceeding 80 mm dia. meter 33.02 80.24 2649.43
2 Providing and fixing to wall or celling and floor rigid CPVC pipes class IV (8 kgf/cm2)
class II (6kgf/cm2) conforming to IS: 4985/2000 AND Pipe fittings of the following
nominal bore with clamp including making good the wall,ceilling and floor all complete
as per specification and direction of Engineer-in-charge.
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
3 Supplying all materials, labour, T&P, fitting & fixing of different size bourden type
pressure gauge(16 kg/cm2). including cost, conveyance & taxes of all materials, T&P
etc. all complete as per P.H. specification and as per the direction of the Engineer-in-
4 Providing and fixing C.I. double acting air valve of approved quality
with bolts, nuts, rubber insertions etc. complete (The tail pieces,
tapers etc if required will be paid separately) :
5 Supply installation, Testing & Commissioning of Horizontal Multi Stage Monoblock
Centrifugal pumps with CI with CED Coated Suction & Discharge Casing, SS 304-
Impellers, SS 304-Shaft, SS 304-Intermediate Casing. Pump shoule come with 380-
415V, 50Hz, 2 Pole, IP 55 Enclosure Class, Class F insulated 0.6 KW (0.8 HP) Motor.
Pump controller suitable for 2 Pumps (1W+1S) with LCD screen displays, phase loss
protection (incoiming as well as for outgoing), Individual pump overload protection,
individual pump under voltage protection, dryrunning protection without installing any
float switch, memory function when power off and during recovery, visual and audio
alarm for fault prompt, auto manual switch and pump should operate based on the sump
water level and both pump should run together for high level. Panel should come with 3
Nos Float switch to work as per the OHT water level.(Make-grundfos,kirloskar,luby or
Per Pump Flow Rate-5 M3/hr (1W+1S)
i 2000ltr (Drinking water) Nos. 2.00 36580.00 73160.00
ii 5000ltr (Drinking water) Nos. 1.00 91450.00 91450.00
UNDER GROUND WATER TANK
1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)
including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m,
as directed by Engineer-incharge.
B) From 1.5M to 3.0M Depth CUM 28.30 341.92 9676.89
2 Filling at all depth with available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each CUM 10.15 130.86 1328.37
deposited layer by ramming and watering complete (lead upto 100m) as directed by the
Engineer-In-charge.
4 Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand : 8 stone agregate
40mm nominal size) as levelling course in floor and plinth including tempering, curring, CUM 1.13 4885.67 5530.95
shuttering etc. complete all depth and height.
5 Brick work with non modular fly ash lime bricks (FALG Bricks) conforming to IS:12894,
class designation 10 average compressive strength in super structure above plinth level
up to floor V level in :
Cement mortar 1:6 (1 cement : 6 Coarse sand) CUM 5.59 4758.82 26600.02
6 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site
of laying , excluding the cost of centering, shuttering finishing and reinforcement,
including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/
retard setting of concrete, improve workability without impairing strength and durability
as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).placing in proper position.
7 Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL
(VIZAG) make including bending, binding, welding and joining if necessary and tying
the grills and placing in position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or
tor steel and binding wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors (Linear measurement will be taken and
quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor
steel only. Wastage if any, including weight of binding wire will not be considered for
measurement) etc. complete as per specification & direction of Engineer-in-charge.
Thermo-Mechanically Treated bars
Beyond 1.50mtr Depth QTL 18.03 10343.53 186453.51
8 Providing and applying two component high performance polymer modifed cementitious
waterproofing coating, Dr.Fixit Fastflex of Pidilite or approved equivalent having
minimum elongation of 120% , shore A hardness of 60 as per ASTM D 2240 and food
grade certification by CFTRI applied @2Kg/sqm in two coats, including reinforcing the
coating with 45gsm glass fibre mesh between the coats at all corners and change in
directions. The coating shall be applied on the entire horizontal and 300mm above the
FFL on the vertical surface as per manufacturer's recommendation. The system includes
base preparation of cleaning, brushing and removal of flacky materials, grouting the SQM 22.64 601.80 13625.66
porous area with cementitious grout, sealing the minor cracks, proper coving between
slab and wall junctions and pre-wetting the surface to attain SSD condition before
application of the waterproofing coating, followed by the application of waterproof
coating. The waterproofing system should be applied directly by the manufacturer with
10 years of insurance backed system warranty against leakage.
Mode of measurement will be actual area treated
9 12mm thick cement plaster (1 : 4) over brick
work with cement punning . in Ground Floor
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
10 16mm cement plaster to inside of brick surfaces with cement mortar of mix 1:6 (1
cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all SQM 19.86 244.97 4864.69
floors and all heights.
11 12mm cement plaster to out side of brick surfaces with cement mortar of mix 1:6 (1
cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all SQM 24.01 171.45 4116.11
floors and all heights.
12 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with
cement mortar of mix 1:4 (1 cement : 4 coarse sand) including necessary scaffolding, SQM 8.49 188.80 1603.02
curing etc. all complete at all floors and all heights.
13 Supplying and Fixing of M.S. Grills, M.S.Doors, M.S. Gate etc including cost,conveyance
of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of kg 104.36 118.00 12314.86
Engineer-in-Charge
14 Supplying and fixing 900mm dia SFRC cover without frame for manhole including cost of
all materials, T&P, labour etc complete as per direction of Engineer-in-charge. NOS 1.89 3304.00 6233.96
15 M.S Panneled Door single leaf shutter with M.S frame including frame made out of M.S
angle and panel shutter with C.R sheet
16 Providing & Applying priming coat with Cement primer of approved brand and
manufacture on plaster surface as per the instruction of Engineer-In-Charge at all sqm 52.36 71.98 3768.59
elevations including all material & labour complete.
17 Providing and applying to outside walls with two or more coats of Anti-Fungal Weather
coat water proofing paint including scaffolding and cleaning the surface before
application of approved colour and manufacture as per specification, instruction of sqm 24.01 168.98 4056.62
Engineer-In-Charge at all elevations including all material labour complete.
18 Preparing surface and painting at all height with two or more coats of interior Plastic
Emulsion "Royale Shyne" of Asian Paints or equivalent of approved shade as per the
instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. sqm 28.35 96.05 2722.98
including interior wall primer & providing scaffolding, cleaning, curing and supply of all
materials and labour complete as per drawing, design and direction of
Architect/Engineer-In-Charge.
19 Providing & Painting with synthetic enamel paint of approved brand Asian / Berger
make (Apex Ultima quality) and manufacture on concrete /Steel work (Grill and Gate) as sqm 2.09 168.98 352.70
per the instruction of Engineer-In-Charge at all elevations including all material & labour
20 2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard
granite crusher broken chips
1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting
out the excavated soil and disposal of surplus excavated soil as directed, within a lead of
B) From 1.5M to 3.0M Depth CUM 15.31 341.92 5233.14
2 Filling at all depth with available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each CUM 11.92 130.86 1559.83
deposited layer by ramming and watering complete (lead upto 100m) as directed by the
Engineer-In-charge.
3 Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete. CUM 1.90 601.33 1144.30
CEMENT CONCRETE
4 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural
sources : 8 graded stone aggregate 40 mm nominal size CUM 1.90 4885.67 9297.18
derived from natural sources)
5 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site
of laying , excluding the cost of centering, shuttering finishing and reinforcement,
including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/
retard setting of concrete, improve workability without impairing strength and durability
as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).
All works upto plinth level
6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more. QTL 14.44 10343.53 149319.43
7 Providing and applying two component high performance polymer modifed cementitious
waterproofing coating, Dr.Fixit Fastflex of Pidilite or approved equivalent having
minimum elongation of 120% , shore A hardness of 60 as per ASTM D 2240 and food
grade certification by CFTRI applied @2Kg/sqm in two coats, including reinforcing the
coating with 45gsm glass fibre mesh between the coats at all corners and change in
directions. The coating shall be applied on the entire horizontal and 300mm above the
FFL on the vertical surface as per manufacturer's recommendation. The system includes
base preparation of cleaning, brushing and removal of flacky materials, grouting the SQM 30.42 601.80 18309.48
porous area with cementitious grout, sealing the minor cracks, proper coving between
slab and wall junctions and pre-wetting the surface to attain SSD condition before
application of the waterproofing coating, followed by the application of waterproof
coating. The waterproofing system should be applied directly by the manufacturer with
10 years of insurance backed system warranty against leakage.
Mode of measurement will be actual area treated
8 12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand) SQM 40.19 194.23 7805.77
9 Neat cement punning. SQM 40.19 80.00 3215.26
10 Supplying and fixing 900mm dia SFRC cover without frame for manhole including cost of
all materials, T&P, labour etc complete as per direction of Engineer-in-charge. NOS 2.00 3398.40 6796.80
11 2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard
granite crusher broken chips
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
INSPECTION CHAMBER
1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting
out the excavated soil and disposal of surplus excavated soil as directed, within a lead of
2 Filling at all depth with available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each CUM 12.10 130.86 1583.21
deposited layer by ramming and watering complete (lead upto 100m) as directed by the
Engineer-In-charge.
3 Supplying and filling sand in foundation and over areas including watering, ramming,
consolidating and dressing, labours, tools, taxes etc. all complete as per the CUM 1.21 601.33 726.13
specification and direction of Engineer-In-Charge.
4 Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand : 8 stone agregate
40mm nominal size) as levelling course in floor and plinth including tempering, curring, CUM 1.21 4885.67 5899.68
shuttering etc. complete all depth and height.
5 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site
of laying , excluding the cost of centering, shuttering finishing and reinforcement,
including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/
retard setting of concrete, improve workability without impairing strength and durability
as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).
All works upto plinth level
6 Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL
(VIZAG) make including bending, binding, welding and joining if necessary and tying
the grills and placing in position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or
tor steel and binding wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors (Linear measurement will be taken and
quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor
steel only. Wastage if any, including weight of binding wire will not be considered for
measurement) etc. complete as per specification & direction of Engineer-in-charge.
7 12mm cement plaster to out side of brick surfaces with cement mortar of mix 1:4 (1
cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all
floors and all heights.
1:4 (1 cement: 4 fine sand) SQM 9.43 194.23 1832.34
8 Neat cement punning. SQM 9.43 27.38 258.26
9 2.5 cm thick A.S Flooring in C.C (1:2:4) including punning using 12 mm size C.B hard
granite chips with cost of all labour & other materials etc complete.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
1 including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting
out the excavated soil and disposal of surplus excavated soil as directed, within a lead of
All kinds of soil
Supplying and filling in plinth with sand under floors, including watering, ramming,
2 consolidating and dressing complete.
peripherial wall foundation cum 0.50 601.33 303.11
Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand : 8 stone agregate
40mm nominal size) as levelling course in floor and plinth including tempering, curring,
shuttering etc. complete all depth and height.
peripherial wall foundation cum 0.50 4885.67 2462.70
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10
average compressive strength in super structure above plinth level up to floor V level in
Cement mortar 1:6 (1 cement : 6 coarse sand) cum 2.259401887 5080.608 11479.14
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site
of laying , excluding the cost of centering, shuttering finishing and reinforcement,
including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/
retard setting of concrete, improve workability without impairing strength and durability
as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).placing in proper position.
All works upto plinth level
soak way galerry
Ded. Man hole cum 0.19 11186.16 2085.44
Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL
(VIZAG) make including bending, binding, welding and joining if necessary and tying
the grills and placing in position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or
tor steel and binding wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors (Linear measurement will be taken and
quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor
steel only. Wastage if any, including weight of binding wire will not be considered for
measurement) etc. complete as per specification & direction of Engineer-in-charge.
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
Thermo-Mechanically Treated bars
well sink with top and bottom cover of min 50 mm thk with cementing Khoa filling etc
1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting
out the excavated soil and disposal of surplus excavated soil as directed, within a lead of
A) Upto 1.5 M Depth CUM 3.14 235.53 739.36
2 Filling at all depth with available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each
deposited layer by ramming and watering complete (lead upto 100m) as directed by the
Engineer-In-charge.
3 Supplying and filling sand in foundation and over areas including watering, ramming,
consolidating and dressing, labours, tools, taxes etc. all complete as per the CUM 0.57 601.33 343.21
specification and direction of Engineer-In-Charge.
Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand : 8 stone agregate 40mm 0.57 4885.67
size) as levelling 2788.52
course in floor and plinth including tempering,
5 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site
of laying , excluding the cost of centering, shuttering finishing and reinforcement,
including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/
retard setting of concrete, improve workability without impairing strength and durability
as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).
All works upto plinth level
6 Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL
(VIZAG) make including bending, binding, welding and joining if necessary and tying
the grills and placing in position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or
tor steel and binding wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors (Linear measurement will be taken and
quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor
steel only. Wastage if any, including weight of binding wire will not be considered for
measurement) etc. complete as per specification & direction of Engineer-in-charge.
7 12mm cement plaster to out side of brick surfaces with cement mortar of mix 1:4 (1
cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all
floors and all heights.
1:4 (1 cement: 4 fine sand) SQM 4.72 194.23 916.17
8 Neat cement punning. SQM 4.72 27.38 129.13
9 2.5 cm thick A.S Flooring in C.C (1:2:4) including punning using 12 mm size C.B hard
granite chips with cost of all labour & other materials etc complete.
SWERAGE PIPE LINE TRENCH
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting cum 29.71698113 235.528 6999.18
out the excavated soil and disposal of surplus excavated soil as directed, within a lead of
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Supplying and filling sand in foundation and over areas including watering, ramming,
consolidating and dressing, labours, tools, taxes etc. all complete as per the
specification and direction of Engineer-In-Charge.
Sand filling in drain trench cum 2.55 601.33 1531.68
Supplying and filling in for CC lining 75 mm all arround on PVC pipes and base along
with Jamuna sand under floors, including watering, ramming, consolidating and
dressing complete.
CC lining in drain pipes @ A(0.0490-0.00785)
Extra CC lining in drain IC chambers @ 10% extra cum 3.14 884.17 2780.27
1 Supplying all materials, labour, T&P and construction man hole chamber of the
following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed,
1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel
inside and benching with cement concrete (1:2:4) using 12mm size h.g
chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing
(1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC
man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity
around the chamber including watering, curing, conveyance of all materials to worksite,
payment of royalty, taxes etc all complete as per approved specification and direction of
the Engineer in charge
Inside size 910mm x 910mm x 910mm NOS 5.00 17419.16 87095.80
TOTAL AMOUNT OF PLUMBING WORKS 22,01,995.68
TOTAL AMOUNT OF PLUMBING WORKS 22,01,995.68
A INTERNAL ELECTRICAL WORKS
1 Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI marked with 20 mm dia
PVC flexible non metallic conduit FRLS type ISI marked ) switch ISI marked , and
ceiling rose ISI marked Make- Anchor/Havells of modular type G.I box with
metallic cover plate (both side) (anti bactorial & flame retradant type) d of suitable
size, modular box with 1.5 sq. Mm FRLSH PVC insulated single core multistandard
copper conductor as earth wire including all accessories and connection as per direction
of Engineer -in -Charge.
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
b) Group control of point in Recessed wirring to light point/ fan point/ exhaust fan point/
call bell point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI
marked 20 mm dia PVC flexible non metallic conduit FRLS
type ISI marked switch ISI marked , and ceiling rose ISI marked of modular type
G.I box with metallic cover plate (both side)(anti bactorial & falme retradant type), of Nos 15 1,211.86 18,177.90
suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard
copper conductor as earth wire including all accessories and connection as per direction
of Engineer -in -Charge.
c) Supplying ,fixing of 6A Plug on the same board in existing switch board with complete
fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame Nos 25 227.74 5,693.50
retradant type)) & other required accessories of ISI marked as approved as per
direction of Engg. -in -Charge.
d) Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A
switch & socket(modular type)( (anti bactorial & flame retradant type)) with
suitable size modular box & cover(anti bactorial & falme retradant type) including Nos 50 599.44 29,972.00
supplying of all required accessories of ISI marked as approved as per direction of
engg-in-charge...
e) Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of
16A switch & socket(modular type)((anti bactorial & flame retradant type)) with
suitable size modular box & cover(anti bactorial & falme retradant type) including Nos 40 761.10 30,444.00
supplying of all required accessories of ISI marked as approved as per direction of
engg-in-charge..
f) Supplying,fixing of 2x6A+1X1 6A Plug on the separate board with complete fitting by
01 no of 16A+2 no 6A switch & socket(modular type) ( (anti bactorial & falme
retradant type) with suitable size modular box & metallic cover plate (both side)(anti Nos 10 1,629.58 16,295.80
bactorial & falme retradant type)including supplying of all required accessories of ISI
marked as approved as per direction of engg-in-charge.
g) Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by
01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & falme
retradant type) with suitable size modular box & metallic cover plate (both side)(anti Nos 2 2,323.42 4,646.84
bactorial & falme retradant type)including supplying of all required accessories of ISI
marked as approved as per direction of engg-in-charge..
2 Receass wiring for circuit/submain wiring with the following mentioned size PVC
FRLSH/LSZH insulated, copper conductor, single core cable ) or equievalant reputed
make A catagory ISI marked as approved, in recessed PVC conduit Heavy duty FRLS
of mentioned size ISI marked as approved) as required as per direction of Engg.-in- - -
Charge. Ncessary test report & Warrnaty certificate to be submitted to the department
for genuinity of product & to avail free after sales service within warranty period for
acceptance of materials
a) 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single
core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic Mtr 211 154.58 32,616.38
heavy duty flexible conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
b) 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single
core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic Mtr 278 171.10 47,565.80
heavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH
c) 4 nos single core 2.5 sq. mm copper wire for phase and neutral and 02 nos of
single core 2.5 sq. mm copper wire for earth continuty conductor .in 25 mm dia non Mtr 445 310.34 1,38,101.30
metallic heavy duty flexible conduit(LDB to LSB/5A SOCKET) (4X2.5+2X2.5)
d) 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single
core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic
heavy duty flexible conduit .(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT Mtr 112 192.34 21,542.08
CONTROL TO CORRIDOOR POINT/DG PANEL ESSENTIAL LOAD) (2X4+1X1.5)
e) 4 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single
core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic Mtr 111 289.10 32,090.10
heavy duty flexible conduit.(PDB to PSB/GAYSER. POINT/AC POINT/DG PANEL ACCL TO
EACH QTR ESSENTIAL LOAD) (4X4+2X2.5)
f) 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single
core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic Mtr 78 228.92 17,855.76
heavy duty flexible conduit .(LFDB TO LBDB) (2X6+1X2.5)
g) 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single
core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic Mtr 40 343.38 13,735.20
heavy duty flexible conduit.(LFDB TO LBDB/power unit/point) (4X6+2X2.5)
h) 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single
core 4 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic Mtr 40 493.24 19,729.60
heavy duty flexible conduit .(LFDB TO FLOOR PANEL TO TPN BDB light ) (4X10+2X4)
i) 4 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single
core 10 sq. mm copper wire for earth continuty conductor in 40 mm dia non metallic Mtr 66 746.94 49,298.04
heavy duty flexible conduit.(FLOOR PANEL TO TPN BDB power) (4X16+2X10)
3 Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole
and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel
enclosure, on surface or in recess, with chained metal cover for the socket outlet, and Nos 14 726.88 10,176.32
complete with connections, testing and commissioning etc. as required as per direction
of Engg.-in-Charge.. .
4 Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole
and earth metal enclosed plug top along with 32 amps. C-series, TP MCB, in sheet steel
enclosure, on surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required as per direction
of Engg.-in-Charge.. . .All the Components should be warrantied for a replacement Nos 2 5,128.28 10,256.56
period of 5 years against defects with ncessary test report & Warrnaty certificate to be
submitted to the department for genuinity of product & to avail free aftersales service
within warranty period for acceptance of materials.
5 Supplying and fixing following size/ modules, GI box along with modular base & metallic
cover plate (both side)(anti bactorial type) plate for modular switches in recess etc as - -
required as per direction of Engg.-in-Charge. MAKE-
b) 1 moudle(75mmx75mm) Nos 10 259.60 2,596.00
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
6 Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked
along with accessories in surface/recess including cutting the wall and making good the - -
same in case of recessed conduit as required as per direction of Engg.-in-Charge
7 Supply and fixing modular type indicator on the existing switch box/cover . Equievalant
higher model of make or equievalant reputed make & model A catagory ISI marked as
approved as required as per direction of Engg.-in-Charge.All the Components should be
warrantied for a replacement period of 5 years against defects with ncessary test Nos 21 126.26 2,651.46
report & Warrnaty certificate to be submitted to the department for genuinity of product
& to avail free aftersales service within warranty period for acceptance of materials.
8 Supplying and installation of AC starter Modular type, or equievalant reputed make &
model A catagory ISI marked as approved coil voltage-415 Volt A.C. & O/L range of 9-
14A range on mod Box of suitable size including modular coveras required as per
direction of Engg.-in-Charge .All the Components should be warrantied for a Nos 14 730.42 10,225.88
replacement period of 5 years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product & to avail free
aftersales service within warranty period for acceptance of materials.
9 Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.
.as required as per direction of Engg.-in-Charge.All the Components should be
warrantied for a replacement period of 5 years against defects with ncessary test Nos 4 241.90 967.60
report & Warrnaty certificate to be submitted to the department for genuinity of product
& to avail free aftersales service within warranty period for acceptance of materials.
15 S/F of Bakelite angle holder/batten holder (make- or equievalant reputed make A
catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of
ceiling rose as per direction of Engg.-in-Charge .All the Components should be
warrantied for a replacement period of 5 years against defects with ncessary test EACH 16 71.98 1,151.68
report & Warrnaty certificate to be submitted to the department for genuinity of product
& to avail free aftersales service within warranty period for acceptance of materials.
16 Supplying,fixing of Blanking plate(modular type)( (anti bactorial & flame retradant
type)) in existing switch box(anti bactorial & flame retradant type) including supplying Nos 16 49.56 792.96
of all required accessories of ISI marked as approved as per direction of engg-in-
B Sub-Head II (Light fitting Fixture & Fan) - -
1 Supplying, installation, of exhaust fan of heavy duty 300 mm sweep of exhaust fan in
the existing wall, including fixing & conntection as required as per direction of Engg.-in- Nos 5 3,683.96 18,419.80
Charge. Replacement Warranty will be 5 years.
2 Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with
louvers of exhaust fan in the existing wall, including fixing & conntection .as required as Nos 3 4,334.14 13,002.42
per direction of Engg.-in-Charge. Replacement Warranty will be 5 years.
3 Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour
ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq
mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Nos 12 2,607.80 31,293.60
Regulator) as required as per direction of Engg.-in-Charge.Replacement Warranty will be
4 Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour
ceiling fan ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq
mm PVC insulated, copper conductor, single core cable etc. as required as per direction Nos 30 2,505.14 75,154.20
of Engg.-in-Charge,Replacement Warranty will be 5 years.. .(With fan Regulator)
5 Supplying and fixing of Energy efficient Recess mounted LED luminaire made up
of CRCA powder coated sheet steel housing of 595 X 595 mm x 70 mm size with of
not more than 25W and system lumens output not less than 3250 lumens (130 lm/ wt)
with diffusers for better light transmission and pure effect with High luminous flux LEDs
for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less
than 10%,internal surge protection of 3 KV, complete with Non integrated isolated
electronic driver (protects the output /secondary side from any disturbance on the input No 40 3158.86 1,26,354.40
/ primary side ensuring safe operation)and all other accessories suitable for operation
on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required
as per direction of Engg.-in-Charge (Make: Panasonic/LT/Trilux /Philips/Wipro or
equievalant reputed make & model A catagory ISI marked as approved.) . The luminaire
must be Replacement Warranty will be 5 years.
6 Supplying and fixing of Energy efficient recessed mounted LED luminaire made
up of CRCA powder coated housing, Top opening clean room LED luminaire of 600 X
600 x 65 mm size with of 45 W and system lumens output not less than 4500 lumens ,
IP65 ,dust free & zero maintenance , anti glare high transmittance PMMA diffuser ,
operating volatge range 150-265 V, high performance potentiometric electronic driver
for zero maintenance , 2.5 KV internal urge protection, L70 B 50: 50,000 hrs., CRI not
less than 80, CCT of 5700-6500 degree K, THD less than 10%,,IP 65 protection
complete with all other accessories suitable for operation on 230 V, 50 Hz supply as
required as per direction of Engg.-in-Charge. (Make:Panasonic /PHILIPS/ Wipro or
equievalant reputed make & model A catagory ISI marked as approved ) .The luminaire
should be Replacement Warranty will be 5 years. .Each CLEAN ROOM FITTING FOR
7 Supplying and fixing of Energy efficient surface mounted square shape 20 W LED
luminaire of dimension of 225x 225 x 35 mm consists of white powder coated , die-
cast Alluminium housing with high quality frosted diffuser for glare-free uniform
lighting distribution with wattage not more than 20 watt and lumen output of 1500
lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with
electronic driver, internal surge protection of 2.5 KV , L70 B50: 30000 hrs (2 yrs Nos 80 1791.24 1,43,299.20
warranty) and all other accessories suitable for operation on 220 V to 240 V supply as
required as per direction of Engg.-in-Charge. ( Make : Panasonic
/Trilux/Osram/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI
marked as approved).The luminaire should be Replacement Warranty will be 5 years
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
8 Supplying and fixing of Energy efficient recess mounted LED luminaire with white
powder coated ,pressure die-cast Al housing ,with high transmititivity,non-yellowing
PMMA diffuser, with wattage not more than 20 watt and lumen output not less than
2600 Lumen ( 130 lumens/watt ) of size 595 x595 x 70 mm , ,CRI not less than 80,CCT
of 5700-6500 degree K,THD less than 10%, with Non integrated isolated driver
(protects the output /secondary side from any disturbance on the input / primary side
ensuring safe operation), all other accessories , life : 50,000 burning hours (5 years
warranty) , Internal surge protection of 3 KV suitable for operation on 230 V, 50 Hz
supply as required as per direction of Engg.-in-Charge. ( Make : Panasonic / LT
/Wipro/PHILIPS or equievalant reputed make & model A catagory ISI marked as
approved.) The luminaire should be Replacement Warranty will be 5 years.
9 SITC of energy efficient LED tube light fittings with decorative alluminium batten and
LED tube light having power rating not more than 20 watt and lumen output not less
than 2200 lumen complete with electronic driver and all other accessories with diffuser
having 5 years warranty i/c connection etc as required as per direction of Engg.-in- Nos 12 940.46 11,285.52
Charge. (Similar to Panasonic/PHILIPS/LT/wipro or equievalant reputed make &
model A catagory ISI marked as approved.). The luminaire should be Replacement
Warranty will be 5 years .
10 SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High
optically efficient diffuser,above wash basin complete with all accessoriesetc. directly
on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, Nos 6 863.76 5,182.56
single core cable and earthing etc. as required as per direction of Engg.-in-Charge.
. )The luminaire should be Replacement Warranty will be 5 years
11 SITC of IP 20 Non-integral flexible LED strip light,High optically efficient diffuser,, 4000K
with 12 w/mtr @ 5Mtr pool with Driver extra as required as per direction of Engg.-in- Nos 2 1792.42 3,584.84
Charge ( Make : Panasonic The luminaire should be Replacement Warranty will be 5
12 Supplying and fixing of small focus light for small monuments as 30W , 5700 K required
as per direction of Engg.-in-Charge Make : )The luminaire should be Replacement Nos 4 3307.54 13,230.16
Warranty will be 5 years
13 Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy
gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge
(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less
shall be ignored)of ISI mark as approved.
c) BDBS,DB,AC DB,FLOOR PANELS,MCBS - -
1 Supplying and fixing of following mentioned way, three pole/single pole and neutral,
sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC
61439-3,integrated door earthing system offering additional safety to the user,High
quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the
DB should be properly pre-treated with 7 tank process and duly powder coated,
phosphatized with powder coated finish, on surface/recess, complete with terminal - -
blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned
copper busbar, neutral busbar, earth bar, din bar. or equievalant reputed make & model
A catagory ISI marked as approved. as per direction of Engg.-in-Charge. The
Distribution boards should be Replacement Warranty will be 5 years
a) 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for
Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with Nos 4 2,558.24 10,232.96
neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet,
IP43-IK09 with metal door
b) Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution
board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar,
earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder Nos 4 2,249.08 8,996.32
painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator)
c) 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)
d) 8 Way(8+24) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for
Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with
neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, Nos 1 3,188.36 3,188.36
IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD)
2 Supplying and fixing 20 amps rating, 240 volts, C series, Double poles MCB ofn the
existing MCB DB complete with connections as per direction of Engg.-in-Charge. The
MCB should be Replacement Warranty will be 5 years .MCB should have the fault Nos 2 392.94 785.88
indication system in different colour for ON, OFF & TRIP condition or Mid trip position for
Trip conditions for easier identification of fault.Warranty on MCB is 5 years.
3 Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of
or equievalant reputed make & model A catagory ISI marked as approved. the existing
MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB
should be Replacement Warranty will be 5 years.MCB should have the fault indication Nos 200 155.76 31,152.00
system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip
conditions for easier identification of fault.Warranty on MCB is 5 years.
4 Supplying and fixing 40 Amps rating, TPN, 415 volts, RCCB,300mA .Make-Equievalant
higher model of in the existing MCB DB complete with connections, testing and
commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC)AC Nos 4 2,650.28 10,601.12
ODU CONTROLLER). The RCCB should be Replacement Warranty will be 5 years
5 Supplying and fixing 25Amps DP 240 volts, RCCB,300mA in the existing MCB DB
complete with connections as per direction of Engg.-in-Charge. The RCCB should be Nos 4 1,991.84 7,967.36
Replacement Warranty will be 5 years
6 Supplying and fixing 40Amps DP 240 volts, RCCB,300mA in the existing MCB DB
complete with connections as per direction of Engg.-in-Charge. The RCCB should be Nos 2 2,272.68 4,545.36
Replacement Warranty will be 5 years
7 Supplying and fixing 63Amps DP 240 volts, RCCB,300mA in the existing MCB DB
complete with connections as per direction of Engg.-in-Charge.The RCCB should be Nos 2 2,619.60 5,239.20
Replacement Warranty will be 5 years
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
8 Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA or equievalant reputed make
& model A catagory ISI marked as approved in the existing MCB DB in the existing MCB
DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC Nos 5 3,116.38 15,581.90
ODU, 8 way TPN BDB IC).The RCCB should be Replacement Warranty will be 5 years
d) (Earthing) INSTALLATION - -
1 S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked
including accessories and providing masonary with cover plate having loccking
arrangement and watering pipe etc (WITH charcoal and salt) as required as per Nos 2 16,398.46 32,796.92
direction of Engg.-in-Charge. The entire earthing system should be Replacement
Warranty will be 5 years
2 S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class
B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat /
wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign
soil, water pouring arrangements, brick masonary enclosure on top with removable RCC Nos 2 2,954.72 5,909.44
cover complete with labour for excavation of pit in all kinds of soil & rock as required
and as per direction of Engineer-in-charge.The entire earthing system should be
Replacement Warranty will be 5 years
3 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as
required.as per direction of Engg.-in-Charge.
4 Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections
etc. as required as per direction of Engg.-in-Charge.
5 Supplying and making brick massonary pedastal with extra super structure including
cement plastering etc as required as per direction of Engg.-in-Charge. Mtr 1 3,197.80 3,197.80
e) CABLING AND END TERMINATION MAIN AREA - -
1 Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL.
conductor power cable of 1.1 KV grade d of following size cables as per direction of
Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the - -
department for genuinity of product & to avail free after sales service within warranty
period for acceptance of materials
a) 3.5core x 240 sq mm ( TO MAIN PANEL ) Mtr 88 1,303.43 1,14,701.66
b) 3.5core x 120 sq mm ( DG PANEL1 RUNS ) Mtr 88 703.07 61,869.95
1.1 Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL.
conductor power cable of 1.1 KV grade of following size cables as per direction of
Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the - -
department for genuinity of product & to avail free after sales service within warranty
period for acceptance of materials
a) 3.5core x 95 sq mm ( FOR FDB 1F,2F, POWER ) Mtr 21 560.87 11,778.18
b) 4core x 16 sq mm (FDB LIGHT 1 RUN UPTO 1F ) Mtr 15 171.82 2,577.30
c) 4 core x 4 sq mm (for small power) Mtr 19 103.69 1,970.05
d) 3.5core x 35 sq mm (To FDB LIGHT / power BDB/UPS PANEL,separate panel for OT
2 LAYING OF CABLE - -
2.1 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not
exceeding 25 SQ. MM direct in ground in the trench in one horizental formation Mtr 12 153.40 1,840.80
including excavation ,sand coushing protection covering and refilling the trench etc as
required as per direction of Engg.-in -charge.
2.2 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding
25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one
horizental formation including excavation ,sand coushing protection covering and Mtr 51 171.10 8,726.10
refilling the trench etc as required as per direction of Engg.-in -charge.
2.3 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding
120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one
horizental formation including excavation ,sand coushing protection covering and Mtr 45 189.98 8,549.10
refilling the trench etc as required as per direction of Engg.-in -charge.
2.4 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not
exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per Mtr 25 49.56 1,239.00
direction of Engg.-in -charge.
2.5 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding
25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as Mtr 22 68.44 1,505.68
required as per direction of Engg.-in -charge.
2.6 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not
exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. Mtr 22 54.28 1,194.16
2.7 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding
25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as Mtr 20 54.28 1,085.60
required as per direction of Engg.-in -charge.
2.8 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not
exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction Mtr 26 95.58 2,485.08
of Engg.-in -charge.
2.9 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not
exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as Mtr 20 151.04 3,020.80
required as per direction of Engg.-in -charge.
2.10 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not
exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as Mtr 8 154.58 1,236.64
required as per direction of Engg.-in -charge.
3 Supplying and making end termination with brass compression gland and aluminium
lugs for following mentioned size cable.as per direction of Engg.-in-Charge. - -
b) 4 core x16sq mm Nos 4 231.28 925.12
4 Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete
with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in- - -
5 Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground
complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.- - -
f) PANELS - -
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
MAIN CONTROL PANEL AT GF - -
1 S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for
both light and power circuit) made out by 2mm CRCA steel sheet duly derusted &
painted by siemens gray powder cote paint is designed as G.A drawing as per direction Set 1 3,18,520.94 3,18,520.94
of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 5
years & compelete test certificate must be submitted along with panel board including
component list.
In commer-1-01 number of 400A 4P Icu=100%Ics,0, LSIG MCCB with micro
processor based release Electrical locking for normal & DG (make- - -
ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)(HVAC & MEDICAL
EQUIPEMENT)(200 KVA TRANSFORMER)
In commer-2-01 number of 250A 4P Icu=100%Ics, 0 LSIG MCCB with micro
processor based release with adjustable overload from 36%-100% & Electrical
locking for normal & DG (make-ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI - -
marked) along with 01 no of 200A 4P onload changeover switch (125 KVA DG
Busbar-1&2 04 numbers of 500Amps Aluminium busbar with 1A/SQ.MM current carring
capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size - -
DMC insulator. (for outgoing)
Out going- 08 numbers of 63A 4P MCB (make- Legrand or equivalent reputed make
ISI marked)BDB P/AC,(timer panel & water supply management,,FIRE,WTP,STP & GF - -
Out going- 5 numbers of 125A 4P Icu=50%Ics, LSIG MCCB withTMR based release
with adjustable overload (make- LEGRAND/Schneider/ABB/Siemens, ISI - -
marked)(FLOOR RAW POWER PANEL ,SPARE,DG PANEL OF OT COMPLEX & CT,AC )
Out going- 6 numbers of 32A 4P MCB ((make-ABB/Siemens/SCHNEIDER/L&T/Legrand,
ISI marked)(LIGHT SUPPLY)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 02 set of digital type multifunction meter with CT for
voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data. - -
(iii) 4 nos of 65kA SP VSD WITH 32A SP MCB - -
FDB LIGHT AT 1F - -
2 S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for
both light and power circuit) made out by 2mm CRCA steel sheet duly derusted &
painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN
CONNECTED LOAD) BUILDING LIGHT)as per direction of Engg.-in-Charge. Set 1 29,528.32 29,528.32
Warrentee period of replacement of panel & accessories must be 5 years &
compelete test certificate must be submitted along with panel board including
component list.
In commer- 01 no 63A 4P MCB 10kA,C series with on/off trip indication Light
load for each floor. ( Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/
Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) - -
/ABB(Equivalant model)or equievalant make with proper model ISI marked)
Busbar- 04 numbers of 63Amps,50kA Electrolytic copper busbar duly sleeved by color
coded PVC sleeve & supported by suitable size DMC insulator.
Out going- 06 nos 32A 2P MCB 10kA,C series UPS Light load for each area UBDB. (
Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant - -
model)/Panasonic(Equivalant model) /ABB(Equivalant model)or equievalant make with
proper model ISI marked)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of 0-60Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or
equievalant make & model)
(iii) 01 set of 0-500 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
FDB RAW POWER AT 1F,2F , OT COMPLEX AREA ALONG WITH DOCTORS ROOM
3 S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for
both light and power circuit) made out by 2mm CRCA steel sheet duly derusted &
painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN
CONNECTED LOAD) BUILDING POWER/AC)as per direction of Engg.-in-Charge. Set 1 1,01,782.08 1,01,782.08
Warrentee period of replacement of panel & accessories must be 5 years &
compelete test certificate must be submitted along with panel board including
component list.
In commer- 01 no 125A 4P MCCB 25kA, with ROM & S. Link. (make-
ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)(Icu=100%Ics)with - -
shunt trip.with axulary for BMS or equievalant make.
Busbar- 04 numbers of 125Amps,50kA Electrolytic copper busbar duly sleeved by color
coded PVC sleeve & supported by suitable size DMC insulator.
Digitally signed by Rakesh
Sl.no. Description of Items UNIT QNTY RATE AMOUNT Rs.
Out going- 04 nos 63A 4P MCB 10kA,C series for power BDB. ( Make-LEGRAND-
Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant - -
model)/Panasonic(Equivalant model) /ABB(Equivalant model)or equievalant make with
proper model ISI marked)
Out going- 02 nos 32A 4P MCB 10kA,C series forExtra power BDB. ( Make-LEGRAND-
Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant - -
model)/Panasonic(Equivalant model) /ABB(Equivalant model)or equievalant make with
proper model ISI marked)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make &
UPS PANEL FOR EMERGENCY(COMMON & CRITICAL) - -
4 S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for
both light and power circuit) made out by 2mm CRCA steel sheet duly derusted &
painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN
CONNECTED LOAD) BUILDING EMERGENCY LIGHT)as per direction of Engg.-in- Set 1 66,397.42 66,397.42
Charge. Warrentee period of replacement of panel & accessories must be 5
years & compelete test certificate must be submitted along with panel board
including component list.
In commer- 01 numbers of 63 Amps 4P MCB.(make-
ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)(Icu=50% Isc) with shunt trip - -
& axulary for BMS & mechnical inter locking for one incommer source to other.
Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded
PVC sleeve & supported by suitable size DMC insulator.
Out going- 04 nos 32A 2P MCB UPS Light load for each floor. - -
Out going- 03 nos 32A 4P MCB OT/ICU POWER/OT MACHINE OR Bed head panel
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of 0-100Amps Ammeter Digital type & CTS.(DIGITAL) - -
(iii) 01 set of 0-500 voltmeter Digital type.(DIGITAL) - -
CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER -
1 HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON STEEL WIRE MESH CABLE
TRAYS with internal dimensions of size 54mm(H) x 200mm(W), of Cablofil make or
equievalant reputed make & model A catogory, ISI marked as approved .The Load
bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span
of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH mtrs 12 702.10 8,425.20
REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of
Engg.-in-Charge. Warrentee period oftray must be 5 years & compelete test certificate
must be submitted .
2 HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON STEEL WIRE MESH CABLE
TRAYS with internal dimensions of size 54mm(H) x 300mm(W), of Cablofil make
or equievalant reputed make & model A catogory, ISI marked as approved .The Load
bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span
of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH mtrs 14 814.20 11,398.80
REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of
Engg.-in-Charge. Warrentee period oftray must be 5 years & compelete test certificate
must be submitted .
3 HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON STEEL WIRE MESH CABLE
TRAYS with internal dimensions of size 54mm(H) x 400mm(W), of Cablofil make or
equievalant reputed make & model A catogory, ISI marked as approved .The Load
bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span
of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH mtrs 12 1,077.34 12,928.08
REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of
Engg.-in-Charge. Warrentee period oftray must be 5 years & compelete test certificate
must be submitted .
4 GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH JUNCTION with
internal dimensions of size 38mm(H) x 225mm(W), of reputed make ISI marked as
approved .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED mtrs 16 2,102.76 33,644.16
JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge.(3
COMPARTMENT TOTAL 54 MM HEIGHT,
TOTAL INTERNAL ELECTRICAL AMOUNT 24,01,298.05
GRAND TOTAL AMOUNT 1,81,55,457.58
GRAND TOTAL AMOUNT 1,81,55,457.58
Digitally signed by Rakesh
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-63.pdf
Tender Document
BOQ_IPHL.pdf
Tender Document
GCC with upto date amendments.pdf
Tender Document
3b SCC.pdf
Tender Document
14 Scope of Work.pdf
Tender Document
8 Milestone.pdf
Tender Document
LIST OF MAKES.pdf
Tender Document
Drawings_IPHL.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .