Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.0 LAccepted-AOC PRATAPBAGAN | ₹69.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹69.0 LRejected-Finance | ₹69.0 L | L2 | Rejected-Finance Rate quoted above Lowest bidder |
| 3 | L3₹69.0 LRejected-Finance | ₹69.0 L | L3 | Rejected-Finance Rate quoted above Lowest bidder |
| 4 | L4₹69.0 LRejected-Finance GORABARI P O JAGADALLA BANKURA 722146 | BANKURA | BANKURA | WEST BENGAL | 722146 | ₹69.0 L | L4 | Rejected-Finance Rate quoted above Lowest bidder |
Tender Value
₹69.0 L
EMD Value
₹1.4 L
Closing Date
16 Jan 2026, 12:40 pmClosed
Executive Engineer (AM)
OFFICE OF THE EXECUTIVE ENGINEER (AGRI - MECHANICAL) BANKURA (AGRI - MECHANICAL) DIVISION, ADMINISTRATIVE BUILDING PRANABANANDA SARANI, P.O. KENDUADIHI, DIST. BANKURA
Installation of New Electrified Pirabakra Major RLI project, Block- Khatra Block, Mouza- Pirabakra, GP- Baidyanathpur, JL No- 113, Plot No- 364 , in Bankura District Under Bankura-II (A-M) Sub-Division Under Bankura(A-M) Division Under Core Sector
2025_WRDD_979244_1
WBWRIDDEEAM/BANeNIT33/CS/25-26
Open Tender
Project Work
120 days
EE AM BANKURA AM DIV
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.4 L
9 Feb 2026
30 Dec 2025
19 Jan 2026
30 Dec 2025
16 Jan 2026
30 Dec 2025
Campaigning in the command area of New Major RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.
Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges
Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C etc.
Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting )
Meeting and onsite demonstration for operation & maintenance of one New Major RLI , water manangement and mode of collection of water tax, building of corpus fund etc
IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 2 and SL - 4
Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.
Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period
MATERIAL Rigid P.V.C. pipes with one loose coupler for every 6.0 mtr. Length and solvent cement accordingly to technical specification as per I.S.No. 4985/2000 with latest amendments and duly I.S.I. certification marked & CIPET tested. 315 mm.dia Class-I (0.25 MPA) ( 90 meter P.V.C Pipe Supply from Departmental store)
200 mm.dia Class-I (0.25 MPA) with Coupler ( 270 meter P.V.C Pipe Supply from Departmental store)
140 mm.dia Class-I (0.25 MPA) with Coupler ( 660 meter P.V.C Pipe Supply from Departmental store)
140 mm.dia Class-II (0.25 MPA) with Coupler
Rigid P.V.C. Accessories of Class-II (0.4 MPA) according to Technical specification as per relevant IS Code with latest amendment & duly I.S.I. certification marked & CIPET tested. 315 mm.dia F.T.P. with Metallic flange
200 mm.dia F.T.P. with Metallic flange
160 mm.dia F.T.P. with Metallic flange
200 mm.dia 60̊ Bend
200 mm.dia 90̊ Bend
140 mm.dia 600 Bend
140 mm.dia 900 Bend
200 x 140 mm.dia Reducer
160 x 140 mm.dia Reducer
200 mm.dia Equal Tee
140 mm.dia Equal Tee
200 mm.dia End Cap, class-III
140 mm.dia End Cap
315 mm.dia Extra Coupler
200 mm.dia Extra Coupler
160 mm dia Extra Coupler
140 mm.dia Extra Coupler
MS ACESSORIES:-150 mm.dia C.I Sluice Valve (ISI Marked IS-14846)
150 mm.dia Alfa Alfa Valve (Nipple Type as per IS 210)
150 mm.dia 900 G.I Bend(Both end flanged ISI Marked IS 1239)
150 mm.dia 900 (with priming) G.I Bend(Both end flanged ISI Marked IS 1239)
150 mm.dia MS Tail Piece One end Flanged other end grooved.
150 mm.dia non return valve
GI Set for quadruped (For Major RLI Scheme) All Material ISI Marked
Nuts & Bolts :- 20 mm x 80 mm
20 mm x 100 mm
16 mm x 80 mm
16 mm x 65 mm
16 mm x 50 mm
Foundation Bolt :- For Distrubution Chamber (20 mm.dia x 375 mm.long)
For Motor driven Pump Sets (12 Nos.)
Compresed Asbestos fibre jointing for Quadruped Set (for raised surface of Flange as per IS-6392/71) 500 mm.dia (Table-5)
Solvent cement conforming to I.S. No. 14128/94 with latest amendments, Medium Bodies.
Rubber Insertion, duly, reinforced 5 mm.thick 2 plies as per I.S.No.-6392 with latest amendments.300 mm.dia (Table-17)
300 mm.dia (Table-11)
300 mm.dia (Table-5)
200 mm.dia (Table-11)
200 mm.dia (Table-5)
150 mm.dia (Table-17)
150 mm.dia (Table-5)
125 mm.dia (Table-17)
80 mm.dia (Table-17)
150 mm.dia Foot Valve Lather Washer
150 mm dia C.I Combined tail Piece Both side Grooved
150 mm.dia MS hose clamp with long nut & bolt
Wooden Sleeper 6" x 4" x 5' Long
(ELECTRICAL ITEMS ) Supply of Electromotor Pumping set with a suitable centrifugal water pump having capacity 200cub-meter/hr. discharge at 24m.head with UPI 125/30 A Pump.The Motor shall be designed for operation at 415Volt.(=10%) 3 phase 50 CPS (=5%).AC supply 1450 RPM.The motor shall be TEFC Shall be conforming to IS 7538 or 325 with latest amendments thereof The pump shall be horizontal single stage split casting conforming to IS 6595 or 5120 with latest amendments thereof.pump should be directly coupled with motor and mounted on a common fabricated MS Base frame with latrst amendments
Supply of 200Amp. Main Switch Complete for 25 HP Motors (Switch Fuse Unit TPN ISI Markes IS-60947)
Supply of 63 Amp Main Switch Complete for 25 HP Motors (Switch Fuse Unit TPN ISI Markes IS-60947)
Supply of 16 Amp Main Switch Complete for25 HP Motors (Switch Fuse Unit TPN ISI Markes IS-60947)
3 Phase Electro Magnetic Star Delta starter For 25 H.P Motor (Motor Controller IS -60947) (BCH make)
Supply of 200 Amp Busbar Chamber
Supply of wooden pannel board of size 6ft. X 4ft. X 1 inch. with 6 Nos. M.S. clamp for Pump House wall mounting
Tools kit comprising Slide wrench set 12" long, Ring wrench set, Side spanner set, Screw Driver 1' long, Hammer 500 Gram, Electrical Tester, Combind Pliers, Funnel 8" etc.
Pump House Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. (considering 50 mm clearence)
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering. For PUMP HOUSE
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steel (SAIL/ TATA/RINL)
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete. a) In foundation & plinth.
b) In superstructure ground floor
Plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor. (a) 15 mm thick (1:6) proportion.
b) 20 mm thick with 1:6 cement mortar.
c) 10 mm thick with 1:4 cement mortar.
25 mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg/sq. Mtr. and up to 16 Kg/sq. mtr.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete A) UPVC Pipes:(i) 75 mm. Dia
B) UPVC Fittings:a) Plain Tee (i) 75 mm. Dia
C) Bend 87.5 degree (i) 75 mm. Dia
Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation. (Payment to be made on the basis of measurement of finished quantity of work)
Priming one coat on timber, plastered surface with synthetic enamel/oil boud primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white) (b) On steel surface (Normal gloss).Two coats (with any shade except white).
White washing including cleaning and smoothening surface thoroughly (5 parts of stone lime and 1 part of shell lime should be used in finishing coat) all floor b) Three coats
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. ii) b) Two coats
Supply Fitting fixing of best quality lock & key for door off Godrej make
Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.
Carriage charge (4%) on every item from Sl. no-68 to 93 Carriage except Item No-68,87
WTA:- Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.
Earthwork in excavation of field trenches as per designed section & alignment for laying of pipe lines(PVC,RCC,ACP etc.) upto a depth of 1500 mm in all sorts of soil including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom as required complete.
Laying of P.v.C. pipes of different diameters within field trenches in curve /straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge.a) 315 mm dia
b) 200 mm dia
c) 140 mm dia
Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand.
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity.
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity.
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-In-Charge.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steelI. SAIL/ TATA/RINL (i)For foundation Blocks of Water Distribution System .
Brick work with Ist class brick in cement mortar (1 : 6) . (a) In foundation and plinth.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster.
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. Complete.
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i) 150 mm. dia. ERW pipe.
Fitting and fixing of M.S. / G.I. / C.I.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. a) 150 mm dia sluice valve.
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Major RLI Scheme. (Rate inclusive of transportation from departmental store to work site)
Labour charges for fitting, fixing 150 mm. Dia. Alfa-Alfa valve with 140 mm. dia.P.V.C. pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C.End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC.
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-inCharge.
Carriage charge (4% ) on every item from Sl. no-95 to 116 excluding Sl. No-95,96 & 100,116
INTERNAL WIRING Fitting of wooden pannel board of size 6ft. X 4ft. X 1 inch. with M.S. clamp on the wall of pump house and made necessary arrangment for fitting fixing the following elctrical equipment including 2 coat of pantigof app.quality as per direction of E.I.C.
Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall 63 Amps On angle iron frame
Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall 200 Amps On angle iron frame
Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto- Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical cables. iii) Star-Delta / Auto-Transformer Starter (Above 15 HP upto 25 HP)
Fixing only MS sheet metal busbar Chamber on angle iron frame on wall. 4 bars, 200 Amps.
Meter loop connection with 1.1 K.v. Gr. 3% core 14 core 10 Sqmm to 50 Sq mm. p.v.C.! XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter to incomming TPN Main Switch 1 Terminal. (Brand: Gloster/Havells/Finolex) d) For MAJOR RLI Scheme i) 50 Sqmm 3.5 Core Aluminium Cable
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) (i) 4Cx 25 sqmm Copper cable conforming to IS 694 in [ 100/200 A TPN switch to Bus-bar]
(ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]
(iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (ISI-Medium quality) [ Star-Delta Motor starter to Motor]
Supplying & fixing bulk head light fitting(Havells Make) on wall / Ceilling incl. S&F suitable 100 watts lamp complete with glass wire-guard and holder.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface] (a) Average run 5 mtr
Connecting the equipments to earth busbar including S & F G (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (a) Solid GI wire (iii) No. 8 SWG
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Supply & Fixing EI danger board on wall 20cm x 30cm ( 8" x 12" )
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Add GST @18% for the item No (68 to 133) on 1283862.34
cess 1% on for the item No (68 to 134) on 1514957.56
Quotation chagre (including Supervision Charge & Security Deposite)
ENERGISATION OF RLI PCC POLE 8MTR. LONG
MS CHANNEL 100 X 50 X6 mm
MS. CHANNEL 75X40X6 mm
MS. ANGLE 65X65X6 mm
MS. ANGLE 50X50X6 mm
MS. FLAT 65X6 mm
HT STAY SET completed
HT GUY INSULATOR
STAY WIRE 7/10SWG
LT STAY SET completed
LT GUY INSULATOR
STAY WIRE 7/12 SWG
G.I EARTH SPIKE
G.I WIRE 5MM
11KV POLY PIN INSULATOR
11KV POLY DISC INSULATOR
11KV HARD WERE FITTING
12KV ISOLATOR SET COMPLETE
ACSR 50 SQ.MM
PVC CABLE 50 SQ.4C.
DTR 63 KVA
11KV V BRACKET
11KV TOP ADOPTOR
D IRON CLAMP
SHACKLE INSULATOR
LT KIOSK 63 KVA
GI TURN BUCKLE
SURVEY OF 11 KV LINE
ERECTION OF SINGLE PCC POLE 8MTR.LONG WITH FITTINGS
ERECTION OF DOUBLE PCC POLE 8 MTR WITH FITTINGS
ERECTION OF5/5 ON DOUBLE PCC POLE 8 MTR WITH FITTINGS
ERECTION OF HT STAY SET COMPLETE
ERECTION OF EARTHING COMPLETE
FIXING OF 11 KV PIN INSULATOR
FIXING OF 11 KV DISC INSULATOR
FIXING OF TEE OFF BRACKET ON SINGLE PCC POLE
STRINGING & SAGGING OF 50 SQ.ACSR(3 WIRE )
ERECTION OF 63 KVA DTR COMPLETE
FIXING OF L A SET COMPLETE
FIXING OF ISOLATOR SET 11 KV COMPLETE
SUPPLY & EARTHING OF LA & OTHER ACCESSORIES TO BE DONE
SUPPLY & EARTHING FOR NEUTRAL POINT OF DTR COMPLETE
FIXING OF LT KIOSK BOX COMPLETE
ERECTION OF SINGLE PCC POLE 8MTR.LONG WITHOUT FITTINGS
ERECTION OF LT STAY SET COMPLETE
FIXING OF LT BRACKET ON SINGLE PCC POLE
FIXING OF SHACKLE INSULATOR
FIXING OF 3 PHASE S/C. WORK COMPLETE
Add Sundries @ 5% on item no (137 to 164) materials cost i.e. 5% of Rs. 996500.91
Add GST @ 18% on item no (165 to 185) LABOUR cost i.e. 18% of Rs. 165636.30
Add CESS @ 1% on item no (165 to 186) AND SL NO 187 Total cost i.e. 1% of Rs. 245275.87
Please Enable Macros to View BoQ information
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.24 MB
Tendernotice_2.pdf
PDF • 0.83 MB
Tendernotice_3.pdf
PDF • 0.11 MB
BOQ_2389281.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid