Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAdmitted-Finance | ₹7.9 L | L1 | Admitted-Finance |
| 2 | L2₹11.0 LAdmitted-Finance | ₹11.0 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SSD Traders L1 | Yogini Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Laminar Air Flow specifications For culture analysis, Bacteriological and Biological applications
1. Type Horizontal Laminar Air flow Bench
2. UV System 250mm, 10-15W UV Lamp 975 Las
3. UV Tin: 1.99 Math-eff
4. Air Velocity: 0.45 m/s (90 fpm +- 20)
5. Noise level <(><<)>58dBA
6. Filtration HEPA 99.999% @0.3um +pre filter
7. Control LED Display with Microprocessor Control
8. Safity Alarms Filbert Replacement and Maintenance
9. Sockets: 2 Waterproof Power Sockets
10. Body Material Electro- galvanized steel with antimicrobial epoxy
-polyester cooting
11. Work Table 1.2 mm (180) SS 304
12. Extend Size (WxDxH) 1035x617 x 950 x617 x 450 mm
13. Iternal Size (WxDxH): 935538 x 550 mm
14. Work Surface Height 750 mm (Adjustable 660-940 mm)
15. Calibration 150-17025
installation & commissioning included Make Scientech/Patsio/Eutech | 1 | Nos | 1,10,000 ₹1.1 L | 1,28,800 ₹1.3 L |
| 2.00 | Compact Dry-Ready to use media Plates
for E-coli and Coliform
Make Tansha/ Himedia | 5,000 | Nos | 85 ₹4.3 L | 120 ₹6 L |
| 3.00 | Digital Thermo Hygrometer | 2 | Nos | 8,000 ₹16,000 | 10,550 ₹21,100 |
| 4.00 | Conductivity/ TDS/ Salinity meter
1. Measuring Range for Conductivity 0-200 us/cm,0-2000
us/cml-20ms/cm;0-500ms/cm
2. Measuring Range for TDS-6-200mg/150-2000mg/1;0-20g/1:0-500g/1.
3. Measuring Range for Salinity-0-70 (after IOT).
4. Measuring Range for Temperature -10-100°C.
5. Resilution:0.1"us, lus, 0.01ms,0.1ms, 0.1°C
6. Accuracy, I digit, -0.5% of the measuring range T(°C)+-0.1 (5-50°C)
7. Temprature Consumption; Automatic with NTC 30k Ohm or Fixed
temperature.
8. Connectors; 8-pol sensor socket, 4-pol USB interface socket.
9. Calibration; Direct input, temperature offset, single-point,
Automatic.
Make-Systronics/Merck/Eutech | 1 | Nos | 1,12,620 ₹1.1 L | 1,18,000 ₹1.2 L |
| 5.00 | Extran MA 02 Neutral Labolene | 4 | Nos | 1,280 ₹5,120 | 2,500 ₹10,000 |
| 6.00 | PH paper tester | 200 | Nos | 249 ₹49,800 | 380 ₹76,000 |
| 7.00 | H2S vial bacteria test vial | 200 | Nos | 25 ₹5,000 | 38 ₹7,600 |
| 8.00 | O-Tolidine reagent Pack of 500 ml | 60 | Nos | 380 ₹22,800 | 1,300 ₹78,000 |
| 9.00 | Field test kit | 20 | Nos | 1,800 ₹36,000 | 2,500 ₹50,000 |
| 10.00 | Sodium bicorbonate (Pack of 5 Kg) | 5 | Nos | 1,204 ₹6,020 | 1,510 ₹7,550 |
Tender Value
₹7.9 L
EMD Value
₹7,884
Closing Date
11 Feb 2026, 5:30 pmClosed
Executive Engineer
Shyamlla Hills, Bhopal
Supply and installation of Laminar air flow, Incubator, Conductivity meter and consumables for microbiological test of water in laboratory of Water testing laboratory SMGD Water Treatment plant, Arera Hills Bhopal.
2026_UAD_478547_1
2025101562
Open Tender
Miscellaneous Works
60 days
Bhopal
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹7,884
1 Apr 2026
27 Jan 2026
12 Feb 2026
27 Jan 2026
11 Feb 2026
29 Jan 2026
Laminar Air Flow specifications For culture analysis, Bacteriological and Biological applications 1. Type Horizontal Laminar Air flow Bench 2. UV System 250mm, 10-15W UV Lamp 975 Las 3. UV Tin: 1.99 Math-eff 4. Air Velocity: 0.45 m/s (90 fpm +- 20) 5. Noise level <(><<)>58dBA 6. Filtration HEPA 99.999% @0.3um +pre filter 7. Control LED Display with Microprocessor Control 8. Safity Alarms Filbert Replacement and Maintenance 9. Sockets: 2 Waterproof Power Sockets 10. Body Material Electro- galvanized steel with antimicrobial epoxy -polyester cooting 11. Work Table 1.2 mm (180) SS 304 12. Extend Size (WxDxH) 1035x617 x 950 x617 x 450 mm 13. Iternal Size (WxDxH): 935538 x 550 mm 14. Work Surface Height 750 mm (Adjustable 660-940 mm) 15. Calibration 150-17025 installation & commissioning included Make Scientech/Patsio/Eutech
Compact Dry-Ready to use media Plates for E-coli and Coliform Make Tansha/ Himedia
Digital Thermo Hygrometer
Conductivity/ TDS/ Salinity meter 1. Measuring Range for Conductivity 0-200 us/cm,0-2000 us/cml-20ms/cm;0-500ms/cm 2. Measuring Range for TDS-6-200mg/150-2000mg/1;0-20g/1:0-500g/1. 3. Measuring Range for Salinity-0-70 (after IOT). 4. Measuring Range for Temperature -10-100°C. 5. Resilution:0.1"us, lus, 0.01ms,0.1ms, 0.1°C 6. Accuracy, I digit, -0.5% of the measuring range T(°C)+-0.1 (5-50°C) 7. Temprature Consumption; Automatic with NTC 30k Ohm or Fixed temperature. 8. Connectors; 8-pol sensor socket, 4-pol USB interface socket. 9. Calibration; Direct input, temperature offset, single-point, Automatic. Make-Systronics/Merck/Eutech
Extran MA 02 Neutral Labolene
PH paper tester
H2S vial bacteria test vial
O-Tolidine reagent Pack of 500 ml
Field test kit
Sodium bicorbonate (Pack of 5 Kg)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TenderDoc_19A.pdf
Tender Documents • 0.50 MB
BOQ_562443.xls
BOQ • 0.40 MB
AffidavitORGdetail.pdf
Additional Documents • 0.32 MB
Download all tender documents and submit your bid