General Manager, Zone-7, U.P. Projects Corporation Ltd. Lucknow. Gomti Barrage, Left Bank, Gomti Nagar Lucknow.
Supply, Installation, Testing and Commissioning of Smoke an Heat Extraction System, Ventilation System, Gas Suppression System at Academic Block Building at Dr. Ram Manohar Lohia Institute of Medical Sciences,Vibhuti Khand,Gomti Nagar, Lucknow(U.P.)
2026_UPPRC_1170657_1
57/UPPCL/GM-7/E-TENDER/2026-27 Dated-15.07.2026
Open Tender
Miscellaneous Works
Percentage
365 days
District-Lucknow (U.P.)
Please refer Tender documents.
2 documents required · 2 mandatory
₹17,700
₹18.1 L
29 Jul 2026
18 Jul 2026
29 Jul 2026
18 Jul 2026
29 Jul 2026
18 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of Smoke & Heat Extraction System, Ventilation System, Gas Suppression System at Academic Block Building at Dr. Ram Manohar Lohia Institute of Medical Sciences, Vibhuti Khand, Gomti Nagar, Lucknow (U.P.) | - | - | - | - |
| 2 | VENTILATION SYSTEM-ANIMAL HOUSE A & B BLOCK | - | - | - | - |
| 3 | Axial Fan for "Exhaust Air (Emergency)" | - | - | - | - |
| 4 | Supply installation, testing and commissioning of single piece long casing (Motor should completely be accommodated inside the fan casing) Vane Axial Fan (multi piece casing are not acceptable) in GSS/MS with powder coated, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE2) H Class insulation for Smoke Exhaust) suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified & Listed on AMCA website (Interpolation of pitch angle shall not be acceptable) and Fan Efficiency Grade ( Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm & Dia 1600 – 5 mm.
All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade.
Fan Casing should be provided with Special Designed Integral Straightening Vanes (Vanes should be integral part of casing, it should not be provided separately as an accessory) to reduced turbulence provide high performance & low noise level. | - | - | - | - |
| 5 | Fans for emergency application Tube axial are to be used.
Sound level for emergency operation it should not exceed 88 Db(A)@ 3 meter (Room condition).Incase of not achieving sound , attenutor has to be added.
Outlet velocity of the fans should not exceed 18 m/s for emergency application. | - | - | - | - |
| 6 | Smoke and heat exhaust fans should be tested and certified for 250 Deg C for 2 hour in accordance to standard 'BSEN12101-3:2015 from TUV SUD PSB Singapore or equivalent internationally recognized fire laboratory | - | - | - | - |
| 7 | Emergency Operation | - | - | - | - |
| 8 | 1500 CFM @25 static pressure | 35 | No. | 42,346.25 | ₹14,82,118.75 |
| 9 | 2500 CFM @25 static pressure | 9 | No. | 55,969.25 | ₹5,03,723.25 |
| 10 | 3000 CFM @25 static pressure | 44 | No. | 61,611.3 | ₹27,10,897.2 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.83 MB
BIDDOC57.pdf
Tender Documents • 23.57 MB
BOQ_2196705.xls
BOQ • 0.55 MB
Cori57.pdf
PDF • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].