Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 CrAccepted-Finance | ₹33.6 Cr | L1 | Accepted-Finance Qualified L1 |
| 2 | L2₹33.7 CrRejected-Finance THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹33.7 Cr | L2 | Rejected-Finance Not L1 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | OMKAR CONSTRUCTION AND BUILDSURE PRIVATE LIMITED L1 | Shubham EPC Private Limited L2 |
|---|---|---|---|---|---|
| 1.00 | CIVIL WORK
Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. | 4,500 | One Square Metre | 7.24 ₹32,580 | 7.43 ₹33,435 |
| 2.00 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means.. | 420.89 | One Cubic Metre | 249.7 ₹1.1 L | 256.24 ₹1.1 L |
| 3.00 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 metre) by Mechanical Means.. | 2,618.22 | One Cubic Metre | 273.79 ₹7.2 L | 273.82 ₹7.2 L |
| 4.00 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 to 3.0 metre) by Mechanical Means. | 250.58 | One Cubic Metre | 342.56 ₹85,838.68 | 354.5 ₹88,830.61 |
| 5.00 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 meters beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/ murum, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 metre to 3.0 metre) by Mechanical Means. | 603.05 | One Cubic Metre | 632.1 ₹3.8 L | 648.65 ₹3.9 L |
| 6.00 | Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift 1.5 To 3 metre) by Mechanical Means. | 131.26 | One Cubic Metre | 1,576.57 ₹2.1 L | 1,617.84 ₹2.1 L |
| 7.00 | Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. | 1,326.57 | One Cubic Metre | 144.77 ₹1.9 L | 149.82 ₹2.0 L |
| 8.00 | Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete. | 652.86 | One Cubic Metre | 1,347.22 ₹8.8 L | 1,394.2 ₹9.1 L |
| 9.00 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete. | 1,188.68 | One Cubic Metre | 2,623.96 ₹31.2 L | 2,715.46 ₹32.3 L |
| 10.00 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. | 2,582.27 | One Square Metre | 129.08 ₹3.3 L | 130.21 ₹3.4 L |
Tender Value
₹32.7 Cr
EMD Value
₹16.4 L
Closing Date
26 Feb 2026, 6:00 pmClosed
Executive Engineer, Public Works Division, Pune 1.
Executive Engineer, Public Works Division, Pune 1.
61-1 - Construction of Administrative Building at Yerawada, for State Consumer Forum, Sub Divisional Officer Pune and Haveli and Legal Meterology Department Pune (Including Electrical Work)
2026_PWDRP_1276745_1
E-Tender Notice No. 61 for 2025-2026
Open Tender
Civil Works - Buildings
720 days
Yerawada Pune.
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
₹16.4 L
Chief Engineer, Public Work Region, Pune.
24 Mar 2026
11 Feb 2026
27 Feb 2026
11 Feb 2026
26 Feb 2026
11 Feb 2026
18 Feb 2026
CIVIL WORK Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means..
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 metre) by Mechanical Means..
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 to 3.0 metre) by Mechanical Means.
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 meters beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/ murum, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 metre to 3.0 metre) by Mechanical Means.
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift 1.5 To 3 metre) by Mechanical Means.
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete.
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete.
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standared 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 centimetre diametre about 30 -60 centimetre deep at 15 centimetre centre to centre as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix- 10 of trap metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying in situ/ Ready Mix cement concrete Mix-25 of trap metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisitionenabled Concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisitionenabled Concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisitionenabled Concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisitionenabled Concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-15 of trap metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed). With fine aggregate (Crushed sand V.S.I. Grade). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying in situ cement concrete M-30 with tremix treatment for 200 millimetre thickness for Concrete Road including laying plastic sheet of 125 micron with groove cutting of 4 millimetre wide and 20 millimetre deep, with necessary refilling with bitumen (excluding reinforcement) with course and fine agreegates (Natural sand/ Vertical shaft impact (VSI) sand finely washed crushed sand) etc. complete.
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted /bolted / welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimetre thick Mild Steel sheet fan hook box of size 180 x 100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diameter round headed screws together with 12 millimetre diameter Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 45 centimetre wide steel ladder of 40 millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diameter mild steel bar for water tank including fixing it in (1:2:4) Mix-15 cement concrete block 60 centimetre x 30 centimetre x 30 centimetre and painting the ladder complete. Fifth Floor
Providing and fixing mild steel grill work for windows, ventilators 20 kilogramme per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing mild steel grill railing 20 kilogramme per square metre with teak wood hand rail of size 75 millimetre x 60 millimetre and sill of 75 millimetre .x 25 millimetre and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing uncoursed rubble masonary of trap stones in cement mortar 1:6 in foundations and plinth of inner walls/in plinth of external walls including bailing out water manually, striking joints on exposed faces and watering complete.
Providing second class Burnt Brick masonry with conventional /Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering complete.
Providing Autoclaved Areated Concrete block masonary of Ecolite or equivalent make conforming to IS:2185(Part 3)- 1984 in extra fine jointing mortor of fixoblock of UltraTech or equivalent in superstructure including striking joints, racking out joints watering and scaffolding complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing Autoclaved Areated Concrete block masonary of Ecolite or equivalent make conforming to IS:2185(Part 3)- 1984 in extra fine jointing mortor of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, racking out joints watering and scaffolding complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimetre thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying Two coats of wall care Putty of 2 millimetre thickness for plastered surface and 5-6 millimetre thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete for plastered walls/ceiling 2 millimetre. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimetre thickness on previously finished plastered surface, including Plaster Groove 6 millimetre thickness or Tape Grooves 35 to 45 millimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete.
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing for basement or under Plinth (Ground) Floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimetre thick Cement mortar 1:3 with conceal, setcrete (RMW), Algaeproof or other alike water proofing liquids, raking of joints upto 35 millimetre depth,filling the joints with 6 millimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete).
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underPlinth (Ground) Floor including filling the gap of 25 millimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 millimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete).
Providing water proof bedding for flooring of bath and water closet, 25 millimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1 kilogramme per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogramme per bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogramme per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 kilogramme per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre x 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Ground Floor
First Floor
Fourth Floor
Fifth Floor
Waterproofing Treatment to new terrace by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112 millimetre thick brick bat coba covered with 20 millimetre mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non- toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kilogram bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50Kilogrambag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, Stilt Floor
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old/ new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces Excluding Primer Coat complete. Stilt Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying two coats of lead/ zinc base oil paint/ bituminous paint of approved colour and shade to new wood work and fiber boards including preparing the surface, knotting, scaffolding if necessary, excluding primer coat etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying of hot applied thermoplastic compound 2.50 millimetre thick including reflectorizing glass beads at 250 grams per square metre area, thickness of 2.50 millimetre is exclusive of surface applied glass beads as per Indian Road Congress:35. The finished surface to be level, uniform and free from streaks and holes complete. Stilt Floor
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Ground Floor
Providing and laying vitrified mirror/ glossy finish tiles for Flooring of decorative type having size 590 millimetre to 605 millimetre x 590 millimetre to 605 millimetre of 8 to 10 millimetre thickness and confirming to Indian Standard 15622: 2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Stilt Floor
Providing and laying vitrified mirror / glossy finish tiles for Skirting having size 590 millimetre to 605 millimetre x 590 millimetre to 605 millimetre of 8 to 10 millimetre thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying vitrified matt fininsh tiles for flooring having size 590 millimetre to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing machine cut both side mirror polished 18 millimetre to 20 millimetre thick telephone black granite/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone partition with rounding the edges etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
"Providing and laying Vitrified tiles (Matt and Antiskid Finish) in floor in 600 millimetre x 1200 millimetre sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shades, laid on 20 millimetre thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etcetra. The tiles must be cut with the zero chipping diameter mono cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily as directed by engineer-in-charge. Rate as per CPublic Works Department item no. 11.41A 3.2 pg No. 644 Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and preparing kitchen otta up to 75 centimetre width, made up from 30 millimetre thick and 75 centimetre high vertical support for kadppa at 1 metre center to center of 25 millimetre thick both side polished kadappa middle shelf and bottom of 20 millimetre thick one side polished kadappa with facia patti of 20 x 50 millimetre kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. Fifth Floor
Providing and fixing 40 millimetre diameter and 1.5 millimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 900 millimetre high S.S. 304 Grade Stainless steel railing with 40 millimetre diameter and 1.5 millimetre thick at top, 40 millimetre diameter and 1.5 millimetre thick vertical supports spaced at 1.5 m center to center and 8 millimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of overall size 1.50 metre x 2.40 metre or as specified with aluminium door frame of powder coated section 101.60 x 44.75 millimetre , 3.18 millimetre thick and shutter compr Indian Standard Institute ng of powder coated section having bottom and lock rail of size 150 millimetre x 44.5 millimetre , 2.90 millimetre thick top rails 47.62 x 44.45 millimetre , 3.18 millimetre thick, vertical style 47.62 x 44.45 millimetre , 3.00 millimetre thick and for shutter plain glass panes 5 millimetre thick for top panels and 12 millimetre thick both side laminated phenol bonded particle board panels for bottom panels, Indian Standard I. mark, heavy duty, Hydraulic floor spring of 150 kilogramme capacity, having heavy duty concealed lock, necessary beeding, glazing clips, Poly Venyl Chloride gaskets, 250 millimetre length tower bolts, 150 millimetre diameter m. pad handle, as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipments. Stilt Floor
Ground Floor
Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing fibre glass reinforced polyster door shutter 30 millimetre thick as per IS 14856 (2000) (reaffirmed 2006 ) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, complete. Stilt Floor
Ground Floor
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 millimetre x 40 millimetre x 5 millimetre with oil painting complete. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Door Frame: Supplying & Fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 kg/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Shutter : Supplying & Fixing of 55 millimetre thick asbestos free 'TUFWUD' brand - 3 criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 kg/cum) frame work of 100x32 millimetre with 32 millimetre thick infill of ceramic fiber (density 128 kilogramme per cubic metre), vermaculite mix faced with 3 millimetre Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing factory made door/Window frames of required colour made with wood Polymer composite (WPC) extuded internal ribbed sections conforming to American Society for testing and materials (ASTM) in regard with density, tensile strength, flexural strength, Izod impact, water absorption and screw withdrawal strength with wall thickness of 5mm (+/1mm) and with frames having mitred joints at each corner, joined together by two nos. of 10 x 8 mm & 40 mm long Poly vinyl chloride dovetail keys including hard wood piece support along the full vertical and horizontal length in rebate portion hole for fixing hinges and fixtures and the frames fixed to Walls/columns with 15 mm long dash fasteners/holdfasts (dash fasteners/holdfasts to be paid separately) etc. complete as per the direction of Engineer in charge,For Profile size of 100 x 50 millimetre with 32 x 12 millimetre rebate. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing factory made door/Window frames of required colour made with wood Polymer composite (WPC) extuded internal ribbed sections conforming to American Society for testing and materials (ASTM) in regard with density, tensile strength, flexural strength, Izod impact, water absorption and screw withdrawal strength with wall thickness of 5mm (+/1mm) and with frames having mitred joints at each corner, joined together by two nos. of 10 x 8 mm & 40 mm long Poly vinyl chloride dovetail keys including hard wood piece support along the full vertical and horizontal length in rebate portion hole for fixing hinges and fixtures and the frames fixed to Walls/columns with 15 mm long dash fasteners/holdfasts (dash fasteners/holdfasts to be paid separately) etc. complete as per the direction of Engineer in charge,with prior approval of concerned Superitending Engineer. For Profile size of 125 x 50 millimetre with 38 x 12 millimetre rebate. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter (35 millimetre thick) of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder and rice husk/bagasse husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kilogramme per cubic metre and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm², modulus of elasticity 2000 N/mm², resistance to spread of flame of Class A category with property of being termite/borer proof, weather/moisture proof, vermin retardant and long with required fixtures of required size with necessary full body threaded star headed counter sunk S.S. screws, all as per direction of Engineer-In-Charge (Note stainless steel butt hinges and necessary stainless steel screws shall be paid separately). Rate as per CPublic Works Department Item No. 26.67.2 pg No. 1664 Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
DOOR ( Both side Laminated ) - : Providing & Fixing 44 millimetre thick both side Laminated Door made up of 18 millimetre thick plywood frame covered with 12 millimetre thick plywood both side of the frame to get required thickness as per architectural design & drawing of CENTURY MAKE COMMERCIAL PLY BWR GRADE (ISI-303) or equivalent make with both side 1.00 millimetre thick laminate of ROYAL TOUCh or equivalent make confirming to {ISi 2046) with grove, finish with 43 x 10 millimetre BTC lipping & 8 millimetre float glass strip as per drawing is fitted by BTC 20x10 millimetre moulding including all materials brass screw, brass hinges {125 x 12 millimetre ) ENOX make mortice lock, door stopper, antitermite treatment to plywood, two oats melamine polish to moulding and lipping, labour charges as directed by lncharge etc. complete Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 millimetre at weight 0.637 kilogramme per running metre with window frame bottom track section 92 x 31.75 x 1.30 millimetre at weight 1.070 kilogramme per running metre. Top and side track section 92 x 31.75 x 1.30 millimetre at weight 0.933 kilogramme per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimetre at weight 0.417 kilogramme per running metre Inter locking section 40 x 18 x 1.10 millimetre at weight 0.469 kilogramme per running metre and handle and top section 40 x 18 x 1.25 millimetre at weight o.417 kilogramme per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position aluminium fixed window fully glazed of any size with Powder Coating as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 millimetre thick clear float glass etc. complete. Ground Floor
Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position (as per I.S.1868:1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 millimetre at weight 0.547 kilogramme per running metre and window frame bottom track section 61.85 x 31.75 x 1.20 millimetre at weight 0.695 kilogramme per running metre, Top and side track section 61.85 x 31.75 x 1.30 millimetre at weight 0.659 kilogramme per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimetre at weight 0.417 kilogramme per running metre. Inter locking section 40 x 18 x 1.10 millimetre at weight 0.469 kilogramme per running metre and handle section 40 x 18 x 1.25 millimetre at weight 0.417 kilogramme per running metre and top section 40 x 18 x 1.25 millimetre at weight 0.417 kilogramme per running metre . As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass with all required screws and nuts etc, complete with colour Anodising without box. Ground Floor
Providing and fixing in position (as per 1868:1982) aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 millimetre at weight 0.637 kilogramme per running metre with window frame bottom track section 92 x 31.75 x 1.30 millimetre at weight 1.070 kilogramme per running metre . Top and side track section 92 x 31.75 x 1.30 millimetre at weight 0.933 kilogramme per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimetre at weight 0.417 kilogramme per running metre. Inter locking section 40 x 18 x 1.10 millimetre at weight 0.469 kilogramme per running metre and handle and top section 40 x 18 x 1.25 millimetre at weight o.417 kilogramme per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete with colour Anodising with box. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position Colour Anodized aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 millimetre thick clear float glass etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing of factory made Fixed Window (Big Series) frame of size 67 x 62 millimetre & Mullion (if required) of size 67 x78 mm. (White Colour) comprising ultra Poly vinyl chloride multi-chambered frame, Sash, & Mullion with wall thickness of 2.3 mm (+-0.2 mm ), duly reinforced with galvanised iron section 1.5 mm, wherever required. ultra Poly vinyl chloride window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below- S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of ultra Poly vinyl chloride glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. ultra Poly vinyl chloride Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing of factory made ultra Poly vinyl chloride casement Window (Big Series) frame of size 67 x 62 mm & Sash / Mullion of size 67 x 78 millimetre (White Colour) comprising ultra Poly vinyl chloride multi-chambered frame, Sash, & Mullion with wall thickness of 2.3 millimetre (+-0.2 millimetre ), duly reinforced with galvanised iron section 1.5 millimetre , wherever required. ultra Poly vinyl chloride window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below- S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of ultra Poly vinyl chloride glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. ultra Poly vinyl chloride Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 millimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimetre maximum center to center distance of 600 millimetre perimeter channel and intermediate channels at maximum center to center distance 1200 millimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 millimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and Fixing of Armstrong OR equivalent GI Lay in Plain metal ceiling consisting of 600 x 600 millimetre Lay in tiles of pre coated galvanized steel in 0.5 millimetre thickness in Global white color tile to be laid on Armstrong or equivalent grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimetre and 600 millimetre Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600 x 600 millimetre Lay in tiles of pre coated galvanized steel in 0.5 millimetre thickness in Global white color tile to be laid on grid systems with 15 millimetre wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimetre and 600 millimetre Cross Tees.products approved as per GRIHA and BS 476. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and Fixing of Armstrong OR equivalent Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled Tegular) Edge Tiles With Armstrong or equivalent 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 99 percent ,NRC 0.5, Light Reflectance ≥85 percent.Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 16 millimetre , with Recycled content of 35 percent. The tile shall be laid on precoated Galvanised Iron channel height 32 with 15 millimetre wide T - section flanges colour white having rotary stitching and XL2 CLIP on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 32 millimetre and a load carrying capacity of 7.57 kilogramme e per square metre and pull out stength of minimum 100 kilogramme . The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system of Armstrong OR equivalent make. The Tile and Grid system used together should carry a 10 year warranty.approved as per GRIHA and BS 476 Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing sky light in Reinforced Cement Concrete roof including frame made of Mild Steel angle 50 x 50 x 6 millimetre with hold fast, sheet glass 12 millimetre thick, Chicken mesh 24 gauge with all accessories and required fixtures and fastening fitting including painting etc. complete. Fifth Floor
Providing and fixing 12 milllimetre thick toughen glass and edge polish as shown in the drawings or as directed, including all necessary fittings like Upper glazing profile, bottom locking glazing profile, standard gasket for profile locking Gasket 12 milllimetre , close soft central 180 weather seal for glass edges as per drawings having glass fixing sections at all sides concealed in partitions etc complete as directed by Engineer -IN-Charge gaps between glass panels should be filled by clear silicon weather proofing sealant EPDM gaskets, handles all necessary fasteners and accessories complete as directed by Engineer-in-Charge" Second Floor
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign Fifth Floor
Providing and laying in trenches 15 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary excavation, fittings, refilling trenches. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and laying in trenches 20 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary excavation, fittings, refilling trenches. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and laying in trenches 25 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary excavation, fittings, refilling trenches. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and laying in trenches 32 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary excavation, fittings, refilling trenches. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and laying in trenches 40 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary excavation, fittings, refilling trenches. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and laying in trenches 50 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary excavation, fittings, refilling trenches. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and laying in trenches 50 millimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogramme es per metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and fixing 50 millimetre diameter water meter with non return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [ without chamber ]
Providing and fixing reinforced cement concrete Medium duty (140 kilogramme ) cover of size 60 centimeter x 45 centimeter with frame over inspection chamber complete.
Providing, constructing and fixing 250 millimetre diameter Inspection Chamber made up of Unplasticised Poly Venyl Chloride material of thickness 3.5 millimetre and height of 259 millimetre with inlet and outlet of 110 millimetre diameter with 75 millimetre diameter 'U' Trap, Ultra shaft pipe of Unplasticised Poly Venyl Chloride material having height of 470 millimetre and fixing Ultra 250 millimetre diameter Unplasticised Poly Venyl Chloride cover and frame in 150 millimetre thick in Cement Concrete 1:2:4, having crushed sand bed of 100 millimetre thick of size 550 millimetre diameter including excavation and refilling the sides of chamber by crushed sand cushioning 150 millimetre thickness, connecting all required Unplasticised Poly Venyl Chloride fittings with rubber lubricant complete.
Providing, constructing and fixing 450 millimetre diameter Inspection Chamber made up of Polypropylene/ polyethylene material of thickness 3.5 millimetre and height of 388 millimetre with 160 or 200 millimetre main inlet(s) outlet and 110 and/ or 160 millimetre branch inlets, with 450 millimetre diameter Ultra shaft pipe of HDPE material having height of 460 millimetre , having Reinforced Cement Concrete cover and frame fixing in 150 millimetre thick in Cement Concrete 1:2:4, having crushed sand bed of 150 millimetre thick of size 750 millimetre diameter including excavation and refilling the sides of chamber by sand crushed cushioning 150 millimetre thickness, connecting all required Unplasticised Poly Venyl Chloride fittings with rubber lubricant complete.
Providing, constructing and fixing 600 millimetre diameter Inspection chamber made up of Polypropylene/ polyethylene material having 315 millimetre diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 millimetre and 200 millimetre pipes having thickness of 5 millimetre and 600 millimetre in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 millimetre having Reinforced Cement Concrete cover and frame fixing in 150 millimetre thick in Cement Concrete 1:2:4, having crushed sand bed of 150 millimetre thick of size 750 millimetre diameter including excavation and refilling the sides of chamber by sand crushed cushioning 150 millimetre thickness, connecting all required Unplasticised Poly Venyl Chloride fittings with rubber lubricant complete.
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying 100 millimetre diameter salt glazed stoneware pipe including fitings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 150 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 225 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying cement concrete pipe of Indian Standard 458:2003 non pressure-2 class of 450 millimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 complete.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogramme with frame etc. complete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogramme with frame etc. complete.
Providing and constructing Brick Masonry inspection trap Chamber 90 centimetre x 45 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels/ half round glazed stoneware pipe channel, salt glazed stoneware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and outside, fixed in cement concrete with Reinforced cement concrete cover medium duty 140 kilogramme etc. complete.
Providing and fixing 40 millimetre . diameter Ball cock medium type with Poly Venyl Chloride float including sockets and necessary fittings and tested as per municipal requirements complete. Stilt Floor
Fifth Floor
Providing and fixing High Density Polymer container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters. Fifth Floor
Providing and fixing Chromium plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing Crome Plated Angular stop cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing Crome Plated sink cock with raised J shaped swinging casted spout of approved make including necessary sockets/union nut etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing Chromium plated a 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing European type white glazed earthenware water closet pan with Unplasticised Poly Venyl Chloride seat and lid with chromium plated brass hinges and rubber buffers including Unplasticised Poly Venyl Chloride and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 millimetre diameter Unplasticised Poly Venyl Chloride flush pipe with fittings and clamps, 20 millimetre diameter Unplasticised Poly Venyl Chloride overflow pipe, mosquito proof couplings Galvanised Iron chain and pulley, with water Jet and fitting including cutting and making good to the walls and floors testing complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing white wash basin with half pedestal of size 515 millimetre x 615 millimetre x 460 millimetre including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 millimetre size with pillar cock, Chromium platedAngular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 millimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32 millimetre diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providng and fixing stainless steel sink of size 600 x 510 x 200 millimetre of Nirali or equivalent make including coupling, outlet pipe, elbow and other necessary fitting, finishing complete. Fifth Floor
Providing and fixing Orissa type white glazed earthenware 575 millimetre water closet pan including 'S' trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories complete. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing half turn 25 millimetre diameter gunmetal flushing cock including all accessories complete. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 75 millimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 100 millimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 15 cm rigid Poly Venyl Chloride Nahani trap including Poly Venyl Chloride grating, bend, connecting piece of Unplasticised Poly Venyl Chloride pipe up to the outside face of wall, making the good damaged surface and testing complete. ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing on walls / ceiling / floor 20 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing on walls / ceiling / floor 25 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing on walls / ceiling / floor 32 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing on walls / ceiling / floor 50 millimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and making Indian Standard Institute Mark ferrule connection of 20 millimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and making Indian Standard Institute Mark ferrule connection of 25 millimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and making Indian Standard Institute Mark ferrule connection of 32 millimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing screw down for 20 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing screw down for 25 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing screw down for 32 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing screw down for 40 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. ultra Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 450 millimetre x 550 millimetre size superior type Belgium mirror with 16 millimetre diameter nickel plated towel rod complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 90 centimetre x 60 centimetre Granite plate engraving 10 centimetre height letter, figures including painting the letters/ figures with approved colour and shade complete.
Providing and fixing lightening conductor system compr Indian Standard Institute ng of errecting Air-Termination consisting of tubular copper rod of 25 millimetre diameter 1.2 millimetre think with multiple points head 1.2 metre long (Heavy Duty) welded or clamped to Galvanised Iron pipe pole, B Grade 50 millimetre diameter of required length with mild steel round base plate of 25 centimetre diameter and 10 millimetre thick at bottom, embeded in cement concrete block of 1:3:6 foundation of size 45 centimetre diameter x 45 centimetre in height and providing earthing with copper earth plate of size 60x60x0.30 centimetres with cadimium plated nut bolts to fix earthing strips burried in specially prepared earth pit 1.5 metre below ground level with 40 kilogramme charcoal and salts with altrernate layers of charcoal and salt and Galvanised Iron pipe 40 millimetre diameter and of 2 metre length burried in earth up to earthing plate remaining portion above ground level for watering and refilling complete.
Providing and fixing copper strip 25 millimetre wide and 3 millimetre thick for lightening conductor including fixing with screws required scaffolding complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and Fixing Accessible Wayfinding and navigation signage systems - Providing and fixing in location as diected by Engineer in Charge, accessible modular wayfinding and navigational signage system comprising of ADA and Harmonised Guidelines compliant sigange and wayfinding elements, in multilingual, tactile and braille format. Sigange systems to be designed for entire building / complex under consideration
Full Height Partitions in Glass finish - Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thick Non Toughened Glass on both side. With all the Joints in the partitions covered with Poly vinyl chloride extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying in place 300mm x 300mm x 9.8mm vitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Supply and installation of cubicles of width and depth as perAthena Lite- SS Series Cubicles- Std Sizes (W x D x H): 900 mm x 1550 mm x 2105 mm, (Height is including 100 mm gap from bottom, Door Width- 600 mm specifications/ site drawings). Cubicle height to be 2105 mm. Made from solid grade compact high pressure laminate as per IS:2046 and EN-438 manufactured under high specific pressure > 5 MPa and temperature >120°C, All doors will be of single colour and made of 12 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminium grade 6063 T5-50 micron epoxy powder coated for surface protection, Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section,Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.etc complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Design, supply, fabrication and fixing of SS, non glare Signage board (2 ft. x 2 ft.- 1 no.) for the accessible parking, as per the approved design and make, having 1.2mm thick SS non glare base plate and Grade 2/ Grade 1 Braille (raised dots)to be etched/ engraved and be raised 0.5mm above base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/ engraved and signage to be installed at a height of 2100mm from the ground level using a post of MS hollow square section (50mm x 50mm) as per the installation procedure specified by the manufacturer and as per accessibility standards and up to the satisfaction of the engineer in charge.
Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6"x 9" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in place 300 millimetre x 300 millimetre x 3 millimetre polyurethane stick on tactile directional tiles and warning tiles having beveled edges and of the approved brand, make and colour and conforming to ISO 23599: 2012 inside the building on all floors in corridors, lobbies , level differences as per accessibility standards and to be installed as per the installation instructions given by the manufacturer using butyl rubber adhesive and the hardware specified by the manufacturer, as per the direction of the engineer in charge complete. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
AluminIum Cladding: Providing and fixing AluminIum Jali Laser cut of 2 millimetre thickness with pure polyester Matt finish exterior grade UV resistant powder coating. The jali to be fixed to the sub framing using self drilling screws which shall not be visible in the elevation. The sub framing to be anchored to the main building using Anchor fasteners. Test report to be submitted for structural stability of the system for its self weight and wind load of 120kmph. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on site. Work shall be carried our including all lead and lifts Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97% of standard proctor density etc. complete (Material obtained from Other sources).
Supplying hard murum at the road site including conveying and stacking complete.
Spreading the hard murum for side width complete.
Compacting the hard murum side widths including laying in layers on each side with power roller including artificial watering complete.
Providing and casting in situ or precast tapering Reinforced Cement Concrete Mix-20 Mountable type Kerb without gutter (as per IRC:86-1983) embedded 125 millimetre below ground level over Mix-10 Plain Cement Concrete finished neatly with Cement Mortar 1:2, setting the same in Cement Mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant.
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 to 20 kilogramme per square metre..)
Providing coursed rubble masonry second sort of trap stones in cement mortar 1:6 in superstructure including raking out joints where plastering is to be done and striking joints when no plastering is to be done on the inside, watering scaffolding.
Providing 38 cm thick Composite masonary with 23 centimeter thick ashlar fine tooled /close punched/chisel dressed masonary of trap/granite/ quartzite/gneiss stones of size (0.40m (L) x 0.15m (H) and minimum thickness of 0.23m) in cement mortar 1: 6 in superstructure including striking joints watering and scaffolding complete for facing and 15 centimeter thick Autoclaved Areated Concrete Blocks of Ecolite or equivalent mech. of size {600xl50xl50)mm in masonry in extra fine jointing mortar of fixoblock of UltraTech or equivalent for backing including 2mm sunk pointing nessesary through stone and proper interlocking as shown in drawing, in superstructure including striking joints, raking out joints, watering etc. Complete. Specification: As Directed by Engineer In Charge.
Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 22 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with a pull-out load of min. 21000N (21KN) tested as per
Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.
Providing and applying a base coat comprising of 1 kilogramme Polydee-MC and 1 kilogramme fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A: 1 B) Antibactorial food grade coating inside drinking watertank in two coats with time interval of minimum 8 hours covering 7 years guarantee on Court Fee Stamp Paper of Rs.100/- etc complete.
Providing and laying ceramic tiles having size 30 centimetre x 30 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 millimetre thick compacted bed of fine fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60 millimetre thick cement concrete paver block of M-35 grade concrete with approved colour and design & pattern.
Providing and fixing in position (as per I.S.1868:1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 millimetre at weight 0.547 kilogramme per running metre and window frame bottom track section 61.85 x 31.75 x 1.20 millimetre at weight 0.695 kilogramme per running metre.Top and side track section 61.85 x 31.75 x 1.30 millimetre at weight 0.659 kilogramme per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimetre at weight 0.417 kilogramme per running metre. Inter locking section 40 x 18 x 1.10 millimetre at weight 0.469 kilogramme per running metre and handle section 40 x 18 x 1.25 millimetre at weight 0.417 kilogramme per running metre and top section 40 x 18 x 1.25 millimetre at weight 0.417 kilogramme per running metre As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass with all required screws and nuts etc, complete with powder coating without box.
Providing and installing Bio Digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30 percent): -33.33 percent Percentage of polyester resin: - 66.67 percent, Water absorption (as per ASTM):-0.30 percent, Flammability as per ASTM, Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45, Izod impact strength:-65KJ/M2, Heat defection/distort temperature:-65deg C, Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Poly vinyl chloride : -100mm Outlet pipe size rigid Poly vinyl chloride :-80mm, Gas outlet rigid Poly vinyl chloride with Valve: 20mm, Bacteria immobilization Poly vinyl chloride mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below Up to 400 user size (5mx2.0mx1.5m), Capacity of Biodigester:-15000 liters, Area of top, bottom and side walls: - 41.00 sq.m, Area of partition walls: 12.00sq.m, Total weight of FRP: - 678.80 kg, Bacteria inoculums quantity: - 5200 liters, Minimum thickness of side walls / top and bottom: 8mm, Number of inside partitions: - 4, Minimum thickness of partition wall: 4 millimetre
Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer.
RWH - Recharge Pit Providing and constructing recharge pit of 2.0 metre deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated Poly vinyl chloride casing pipe wrapped around with netlon mesh including 300 millimetre thick sidefilling around outside of RCC rings (annular space) with 40 millimetre size boulders including filling of recharge pit up to 0.5m depth with 25-75 millimetre clean washed gravels from bottom up followed by 0.5m depth of 10-25 millimetre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, Poly vinyl chloride rungs, Poly vinyl chloride end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Boring/drilling bore well of 300 millimetre dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90 metre depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized Poly vinyl chloride medium well-casing pipe of 150 millimetre dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge.
Preparation of Instant Lawn in 100 Sq. mtr area (Depth 20.00 cm) incuding excavation for a depth of 20 cms, removing excavated material up toadistance of 50 mtrs, Filling fresh garden soil / silt & manure in excavated area of depth 20cms. Mixing garden soil/silt & manure thoroughly well, watering previous night., Providing on site well established (free from weeds /disease etc.) ready to fix lawn turf in slabs/ rolls of required variety , Planting required plant species; lawn grass including Maintenance of Newly Developed lawn (Instant Lawn) Area for first 30 days etc. complete as directed
Preparation of Shrubbery (Depth 30.00 cm) incuding excavation for a depth of 30 cms, removing excavated material up toadistance of 50 mtrs, Filling fresh garden soil / silt & manure in excavated area of depth 30cms. Mixing garden soil/silt & manure thoroughly well, watering previous night., Providing on site required variety of shrubs as directed , Planting required plant species; lawn grass including Maintenance of Newly Developed shrubs Area for first 30 days etc. complete as directed
Plantation of Trees (1 m to 2 m) incuding excavation of pit size 0.60 x 0.60 x 0.60 m removing excavated material up to a distance of 50 mtrs, Filling fresh garden soil / silt & manure in excavated area , Mixing garden soil/silt & manure thoroughly well, watering previous night., Providing on site required variety of Trees (plant height 1 to 2 m) as directed , Planting required plant species; including Maintenance of Newly planted trees for first 30 days etc. complete as directed
Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 & 18 millimetre Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 600 millimetre center to center on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish etc., as per Architectural & Acoustical Design & Instructions & Complete in all aspects. .including all materials labour,finishing etc. complete. Ground Floor
First Floor
Third Floor
Fourth Floor
Providing and fixing Table of Size 1500 x 600 x 750 millimetre Top made from 25 millimetre Prelaminated Particle board. All edges are covered by 2 millimetre thick Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimetre both side prelaminated particle boards.All edges are covered by 0.8mm Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. millimetre with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 millimetre Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. thick Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. thick Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine. Ground Floor
Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing & Arrangemnt of High Back Chair, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery. Ground Floor
First Floor
Second Floor
Third Floor
Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (kgs): 66 (Kg) Seating Capacity: Five Seat Ground Floor
First Floor
Second Floor
Third Floor
Providing And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing & Fixing of TILE BASED Aluminum partition system of 1800/1200 mm ht. made of 60mm thick aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/ exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look.Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thick , and prelaminated partical board lower tiles in laminate finish of 9 millimetre. thick on both the sides. Ground Floor
Second Floor
Third Floor
Providing & Fixing of Table @ 1800L x 900 D x 750 HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with Poly vinyl chloride edge band as per drawing. Ground Floor
First Floor
Second Floor
Third Floor
Providing & Fixing of PEDESTAL @ 420 L x 450 D x 650 HT to be made out of Complete Membrane consist of three Drawers as per drawing. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H to be made out of Membrane Finish (2 Openable Shutter & 3 Drawer Pedestal in between) as per drawing. Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing Table of Size 1200 x 600 x 750 millimetre Top: made from 25 millimetre Prelaminated Particle board. All edges are covered by 2 millimetre . thick Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimetre both side prelaminated particle boards.All edges are covered by 0.8mm Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Double Faced Mobile Unit for Compactor 2150 millimetre H x 2745 millimetre W x 900 millimetre D - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimetre thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 kgs. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000 millimetre x 200 millimetre x 60 millimetre DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing & arrangemnt of high back chair - tilt mechanism with multilocking, high density cushion on seat composite leather with metallic silver finish base and arms with P.U.castors gaslift for height adjustment. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 millimetre thick & Top in 2 millimetre thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Providing & Fixing in position, Acoustical Ceiling made from Gypsum Plain Panels on approved heavy duty galvanised iron frame ceiling channels at 450 mm center to center, & intermediate channels not more than 1200 mm center to center, along with ply wood forms suspended with Hangers from Roof, in front of 1000 Gsm synthetic wool 50 mm thick, with Paint, including cost of required Cut-Outs, decorative mouldings / finishing-items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc. complete. Ground Floor
Second Floor
Third Floor
Fourth Floor
Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7 millimetre thick CRCA & Shutter in 1.2 millimetre thick CRCA with glass pannel in Powder coating finish as per drawing. First Floor
Providing and fixing Table of Size 1350 x 600 x 750 mm. Top made from 25 millimetre Prelaminated Particle board. All edges are covered by 2 millimetre thick Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, First Floor
Providing and fixing Single Faced Mobile Unit for Compactor 2150 millimetre H x 2745 millimetre W x 457 millimetre D - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimetre thick MS Sheet Size of Channel 25 millimetre x 100 millimetre x 45 millimetre GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 millimetre thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 kgs. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). First Floor
Second Floor
Providing and Fixing Bed Side Table of size 400LX 400DX 415H. The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2 millimetre thick Poly vinyl chloride edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2 millimetre thick Poly vinyl chloride edge Banding Ground Floor
WITNESS BOX - Providing and fixing witness box of size 1.20 m x 2.4 m x 0.15m with vertical and horizontal and sloping surfaces made in 0.018m thick commercial BWR Plywood with the hand rail made up ofT.W. section of {0.06m x 0.07m)and balusters of size 0.065m X 0.065m X 0.80m, with vertical supports to horizontal and sloping surfaces at edges and in middle in 0.018m thick commercial plywood. The exterior surfaces of the plywood box must be finished in 1mm thick decorative laminate and internal surfaces should be finished in 0.8 mm thick white laminate and BTC patti edging including all necessary labour, lift, material, equipment as per directed by architect and engineer incharge etc, complete. Ground Floor
First Floor
Third Floor
TWO SEATER SOFA Providing and fixing Frame In Hardwood fully Cushioned In Seat & Back, with arms. Stainless Steel Legs at the base. Two Seater Sofa - 1350 millimetre W x 2 750 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve-Seat 550 millimetre , as per the sample approved by Architect, etc complete as directed by Engineer In Charge. Ground Floor
Second Floor
Third Floor
THREE SEATER SOFA Providing and fixing Frame In Hardwood fully Cushioned in Seat & Back, with arms. Stainless Steel Legs at the base. Three Seater Sofa - 1950 millimetre W x 750 millimetre D x 750 mm H Armrest 150 mm with Curve Seat 550 millimetre , as per the sample approved by Architect, etc complete as directed by Engineer In Charge Ground Floor
First Floor
SINGLE SEATER SOFA Providing and fixing Frame In Hardwood fully Cushioned In Seat & Back, with arms. Stainless Steel frame/Legs at thebase. Single Seater Sofa of dimentions 840 millimetre W x 850mmD x 750mmH Armrest 150mm with Curve-Seat 550 millimetre , as per the sample approved by Architect, etc complete as directed by Engineer In Charge. FORUM LEGS, SQUARE PIPE,REGULAR POWDER COAT FINISH, FORUM END SOFA LH SUPERSTRUCTURE,\N\N AST FAB FORUM END SOFA RH SUPERSTRUCTURE.WW AST FAB Ground Floor
CONFERENCE TABLE Providing and fixing conference room table of size 5.0 metre x 1.2 metre, having height of 750 mm as shown In drawing made up of 12 millimetre / 19 millimetre thick plywood Conforming to ISl-303 , The top shall be finished with veneer, all the support Plywood Conforming to ISI 303 19 millimetre thick face finished with white laminate, as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and melamine polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer-In-Charge. Ground Floor
Second Floor
Third Floor
DINING TABLE SET Providing and fixing Cafe table in "Square" shape of required size 900x900 as shown in drawing made up of 12 millimetre / 19 millimetre thick plywood/Prelam boards conforming to IS1-303, Square Cafe Table with BSL Top of 25 millimetre thick & Round finished with Side Edges finished with Poly vinyl chloride Edge banding, 18 Frame in S. Steel / M.S of 60mm dia Centre Pipe supported by 4 legs of 45 millimetre T pipes, fitted on M.S.bracket. Sizes:- 900 millimetre x 900 millimetre Squareetc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and polishing 2 coat to all surface etc. complete as directed bv Engineer -ln-Charge Fifth Floor
DINING CHAIR Providing and placing injection molded Polypropylene without handle chair of size 450 millimetre x 560millimetre and height 815 millimetre made up of 20 primarily of 7/16" diameter steel rod with fire retardant power coating, injection molded Polypropylene seat and back etc. complete as per drawing and image and as directed by Engineer-In- Charge. Fifth Floor
FULL HEIGHT PARTITION: Providing and fixing full height partion of 90 millimetre (hick, made In Plywood 0.018m thick and clear glass panels 0.006 metre thick and Teakwood frames, The Transom section of 0.110 metre x 0.065 metre and Mullion section of 0.065m x 0.110m thick to be used for main frame of plywood panels, section of size 0.065m x 0.040m to be used for sub frames. The Glass panels fixed into the frame and supported with mouuldings of size 0.025 metre x 0.025 metre finished in melamine polish, the plywood is finished with 0.004 metre thick Veneer finished in melamine polish, top portion left open for ventilation as per drawing and directed by architect and engineer incharge. Ground Floor
First Floor
Third Floor
Judges Chair- Providing and fixing Judges Chair (0.6 metre x 0.6 metre x 1.15 metre ) made up of teakwood beam and legs of size 0.06m x 0.06 metre with the seat and back rest made in 0.018 metre thick plywood of the approved make finished in 4mm thick veneer of the approved make all natural wooden surfaces polished in melamine polish and provided with antitermite treatment. The legs must have horizontal braces ofT.W. members of size 0.025 metre x 0.025 metre , the hand rest also made up of Teakwood members of size 0.060 metre x 0.060 metre including all labour, leads, lift, as per drawings, as directed by architect and engineer incharge, etc. complete. Ground Floor
First Floor
JUDGES TABLE - Providing and fixing Table at court hall having size 3.86 metre x 0.80 metre and Height 0.80 metre made up of 18 mm thick Century make commertial ply BWR grade (IS-303) frame work with all side covered with 1.00 millimetre thick Laminate and inside with 0.80 millimetre thick white laminate, Drawers shall make in 12 millimetre thick plywood with laminate inside shall be provided, necessory Fevicol, Anti termiete treatment, Nalis, Abro tape, Drawer Channel 24", S.S. Handle 4", S.S. Hinges 3" x 1" x 1", Lock Drawer, Ball Catch S.S., Cable Manger etc. complete as per drawing and design. As diected by Engineer in charge. Ground Floor
First Floor
LAWYERS TABLE - Providing and fixing Lawyers Table at court hall having size (2.S metreX 0.75 metreX0.85 metre) made up of 18 mm thick approved make commertial ply BWR grade (IS-303) including exposed surface covered with 1.00 millimetre thick Laminate externally and inside with 0.80 millimetre thick white laminate, all lipping finish with melamine polish as to match laminate colour. Supported on teakwood frame of legs and frames of Cross section 0.065 metre x 0.065 metre with anti-termite treatment and melamine polish finish etc. complete as per drawing and design. As diected by Architect or Engineer in charge, etc complete. Ground Floor
First Floor
Second Floor
Third Floor
Full Storage Cabinate Providing and fixing "Rectangular" Shaped Full storage cabinate of sizes 1800 millimetre x 600 millimetre x 2100 millimetre as shown in drawing, made up of 12 millimetre / 19 millimetre thick plywood conforming to ISl-303, 4 door storage unit with both side laminates & all side edge bending in, all the support, horizantal members made of plywood, 19mm t,hick finished with external laminate, inlernai surfaces finished with 0.8 millimetre thick internal laminate, including shutters and drawers with telescopic sliders of required sizes, handles , hinges, lock, knobs, magnet etc as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
CORNER WORKSTATION 1360 x 1350 x 600 x1200mm height. (CLUSTER OF 1) Providing and fixing of workstations System 50 millimetre thick Tile Base Partition System at 1200 millimetre height, 1st Module with Prelam particle board Tile, 2nd Module Pin-up, Marxer & Fabric Tile, Electrical connection below the worktop on Raceway & Skirting Level, Table Top considered in 25 mm thick prelam particle board finish with Poly vinyl chloride lipping 2mm thick having height 727 millimetre from Ground Level,Understructure with Prelam Gable Ends with Brackets and Retum Prelam Combo Storage having size750X400x 727 millimetre etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
WRITING DESK -Providing and fixing Writing desk having size (0.53 metre x 0.46 metre x 0.30 metre) made up of 18 mm thick Century make commertial ply BWR grade (IS-303) including exposed surface covered with 1.00 millimetre thick Laminate Front side design as per detail drawing, inside 0.8 millimetre thick white laminate with necessary hardware, labour including Anti-termiete treatment etc. complete. as per drawing and design. As diected by Engineer in charge. Ground Floor
First Floor
Third Floor
Fourth Floor
RECEPTION TABLE Providing and fixing table In "Rectangular" shape of size 2.4 metre x 0.750 metre having height of750/1050 millimetre & side cablnate/Pedestal 0.7metre x0.55 metre x0.70 metre deep as shown in drawing 12 millimetre / 19 millimetre thick plywood conforming to ISI -303 , The 50mm thick top of made up of 19+19mm Ply fitted to 50x12 millimetre teak wood frame on either sides shall be finished with veneer to top and edge, 50mm thick section made up from ply for hand rest with frame finished with white uni-core laminate, 19mm/12mm thick ply for drawer externally finished with grey laminate, & internally finished with white laminate, all the support,horizantel members of plywood, 19mm thick conforming to ISI -303 finished with veneer/ internal surfaces finished with 0.8 millimetre thick internal laminate/External Laminates as shown in drawings, powder coated Aluminium skirting at bottom matching to Veneer/ white uni-core laminate with veneer ,including provision for cable manager, raceways for cables and wires, ply foot rest finished with veneer, Including shutters and drawers with telescopic sliders of required sizes, hinges, handles, tock , magnet, cable manager, knobs, including pasting,screwings, cutting, jointing, finishing etc. as shown in the drawing and antitermite treatment to all plywoods and melamine polishing 2 coat to all veneer and wooden surface etc. complete as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Library Storage - Providing and fixing Library Storage having size 0.83 metre (length) x 0.43 metre (width) and Height 3.90 metre made up of 18 millimetre thick Century make commertial ply BWR grade (15-303) frame work with all side covered with 1.00 millimetre thick Laminate and inside with 0.80 millimetre thick white laminate, Shelfs shall make in 18 millimetre thick plywood with laminate inside shall be provided, 5mm thick clear glass provided on door, necessary Fevicol, Anti termiete treatment, Nalis, Abro tape, S.S. Handle 6", S.S. Hinges 5" x 1" x 1", labours, etc. complete as per drawing and design. As diected by Engineer in charge. First Floor
Notice Board - Providing and fixing Notice board having depth 0.13 metre made up of 18 millimetre ,thick Century make commertial ply BWR grade (IS-303) as per Architectural Design and Drawings and finish with all exposed surface covered with 1.00 mm thick Laminate and inside surface finish with trench polish including 12mm soft wood on 18mm ply glued and bolted with 8mm thick clear glass with lock etc. complete as per drawing and design. As diected by Engineer in charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
PAINTINGS IN SQM Providing And Fixing In Position Various Type And Size Of Paintings In All Suites/ Areas, From Recognised Artists. Including The Materials Of Painting Like Canvas, Colours, Design, Frames Etc, Complete To Be Displayed In All Respect On The Areas Allotted, On Stretched Canvas, As Per The Sizes And Designs Approved By The Principal Architect To All The Involved Artists Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
TV UNIT 1800X350X300 Providing and fixing TV Unit of size 1.8 metre x 0.350 metre having height of 300 millimetre as shown in drawing made up of 19+19 mm thick plywood conforming to ISI 303, The top shall be finished with veneer, all the support Plywood Conforming to ISl-303 19mm thick finished with white laminate, internal surfaces finished 0.8 mm thick internal laminate, including provision for cable manager, raceways for cables and wires,includlng shutters, handles, lock, hinges, cable manager, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete as directed by Engineer -ln-Charge. Ground Floor
First Floor
Curtains/Blinds MAC - BLACKOUT TORINO TR 5408 Providing and fixing Curtains/Blinds MAC - BLACKOUT TORINO TR 5408 for windows, Including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
GRACIA BGR5606 for windows, Including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
CURTAIN MAC - Zebrano NS-73 Providing and fixing Curtains/Blinds MAC -Zebrano NS-73 for windows, Including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
ELECRICAL WORK Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete.
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories.
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing and erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc .
Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation on with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP
Supplying, installing, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type multi stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete as per specification no. FF-MFP/JP
Supplying, installing, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type single/multi stage centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation on with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/BP
Supplying, installing, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v 50Hz AC supply diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding residential silencer instruments and protection as per standard specification stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/DP
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern PN16 pressure rating SS screen end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern PN16 pressure rating screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV
Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV
Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia for supplying water in fire tank complete as per specification no. FF-FA/FMC
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, installing, testing and commissioning of heat detector with combination ROR and Fixed Temp. complete as per specification no. FF-FAS/HD
Supplying, installing, testing and commissioning of optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD
Supplying, installing, testing and commissioning of manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP
Supplying, installing, testing and commissioning of hooters having high (100dB 1m) and low (94dB 1m) volume setting group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR
Supplying, installing, testing and commissioning of FRLS XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of 16 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories 16x2 Character LCD Display provision for zone wise contact and beep sound alarm suitable to operate on 120-220 V AC 0 - 49 Deg C 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler 15 mm (½ ) dia. NBCM Body chrome finished 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.
Supplying, erecting, testing and commissioning of vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Supplying and erecting ISI mark GI pipe 50 mm. dia ‘C” class position with accessories complete. Specification no. CW-PLB/GP.
Supplying & installation auto glow (Viewing upto 15 mtr length) fire signages viz fir hydrant Fir Ex inguishers Fire Exit Fire door Fire house box ect. Size of 300x100 mm
Supplying & installation auto glow (Viewing upto 15 mtr length) fire signages viz fir hydrant Fir Ex inguishers Fire Exit Fire door Fire house box ect. Size of 450x150 mm(NCSR)
Supplying & installing auto glow (Viewing upto 15 Mtr length) fire signages viz Fire Hydrant Fire Extinguishers Fire Exit Fire Door Fire Hose Box etc. Size of 600 X 200 mm
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Providing Round bottom fire bucket of 9 Litres capacity as per IS 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark on provided stand/ wall hook complete.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
61_1.pdf
Tender Documents • 8.88 MB
BOQ_2196988.xls
BOQ • 1.26 MB
Drawings.rar
Other Document • 7.35 MB
Download all tender documents and submit your bid