Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
7 Sept 2020, 11:30 amClosed
EX. ENGINEER (E AND M) W-S (SOUTH-WEST)
D BLOCK OHT OPP DESU COLONY JANAKPURI NEW DELHI-58
Renovation of LT Panel and allied works at various BPS under the Command area of CT-5 Dwarka Sub-city.
2020_DJB_194062_11
N.I.T. No. 05 (2020-21)/ E.E.(EandM) WS- SW
Open Tender
Civil Works
Works
45 days
OFFICE OF THE EX. ENGINEER (E AND M) W-S (SOUTH-WE
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB EMD Ac No. 50448339804
₹14,000
23 Sept 2020
31 Aug 2020
7 Sept 2020
31 Aug 2020
7 Sept 2020
31 Aug 2020
Renovation of LT Panel at Sec 17 Pkt A, Sec 16B Pkt 2 and Sec 16 B Pkt 3:- Dismantling of damaged components from the existing panel ,removing of damaged control wire etc.
Replacement of the following components in panel complete with control wiring ,fitting of MS base frame for fitting of the components, Cutting door for fixing of components as required, complete cleaning, servicing of the panel ,checking of tightness of the hard wares, contacts parts etc. Testing & commissioning of the panel on load at site.
MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz,250Amp. Make L&T/Siemens/Schineder/DJB approved makes.
MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz,200Amp. Make L&T/Siemens/Schineder/DJB approved makes.
MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz,100-125Amp. Make L&T/Siemens/Schineder/DJB approved makes.
MCB Triple pole 63Amp. Make L&T/Havells/Schineder/ DJB approved makes.
Capacitors 415V unit of 15Kvar Make: Epcos/ DJB approved makes.
Digital Amp. Meter. -Make AE/L&T
Digital Volt Meter0-500V -Make AE/L&T
Current Transformer200/5 Make AE /Advance
Current Transformer100/5 Make AE /Advance
Power contactor 220V 3phase140Amp. Make:-L&T/siemens/Schineder/ DJB approved makes.
Power contactor 220V 3phase110Amp. Make:-L&T/siemens/Schineder/ DJB approved makes.
Power contactor 220V 3phase70Amp. Make:-L&T/siemens/Schineder/ DJB approved makes.
Over load relay 66-110 Amp. Make L&T/siemens/Schineder
Indicating lights LED type RYB & On/OFF. Make : L&T /Havells
Replacement of LT Panel at Sec 13 Pkt A:-Fabrication of Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated, floor mounted type, dust& vermin proof, outward opening of door, lockable doors having hidden hinges locking system inside the panel and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide protection .The each compartment of the fabricated LT panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipment’s of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. The control wiring of the panel will be done with flexible copper wires of 1.5sq mm and each wire will be terminating with a copper ferule crimped, panel size 1600X1200X400mm. Having following components of approved make.
MCCB 415V, FP 3phase High breaking capacity 50KA 50Hz,200Amp with spreader - Make L&T/Havells/DJB approved makes.
MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,100Amp with spreader - Make L&T/Havells/DJB approved makes.
MCB Single pole 6Amp. Make L&T/Havells/DJB approved makes.
MCB Triple pole 63Amp. Make L&T/Havells/DJB approved makes.
MCB Triple pole 20Amp. Make L&T/Havells/DJB approved makes.
Power capacitors 415V unit of 15Kvar Make: Epcos/L&T//DJB approved makes.
Over load relay 36-60Amp.Make: L&T/Siemens/DJB approved makes.
Over load relay 6-10 Make: L&T/Siemens/DJB approved makes.
Digital Amp. Meter Make AE/L&T/DJB approved makes.
Digital Volt Meter0-500V -Make AE/L&T/DJB approved makes.
Motor protection Relay Make: L&T/Siemens/DJB approved makes.
Power contactor 220V 3phase70Amp. MakeL&T/Siemens/DJB approved makes.
Power contactor 220V 3phase18Amp. MakeL&T/Siemens/DJB approved makes.
Star delta timer on delay make: L&T/Siemens/DJB approved makes.
Indicating lights LED type RYB & On/OFF (dia. 16 mm). Make : L&T /Havells
Current Transformer200/5, rated burden in VA 15. Make AE /Advance/DJB approved makes.
Current Transformer100/5, rated burden in VA 15. Make AE /Advance/DJB approved makes.
Current Transformer30/5Make AE /Advance/DJB approved makes.
On load change over switch 200Amp. Open execution type Make:L&T/Havells//DJB approved makes.
Dismantling of the existing old damaged panel & starter, removing of cable connection & shifting the same from site
Loading, unloading by crane & heavy labour & cartage up to site
Re-dressing/Laying & making end termination of both incoming &out going side of cable with brass compressed cable gland, thimbling on removable cable gland plate
Installation fixing of new panel with all electrical and mechanical connection with proper thumbing tapping & connection of cable with motor. Making foundation with M.S. angle & channel, grouting and required civil work for proper foundation
Testing & commissioning of the panel & other accessories with relevant IS as follow: - Check equipment’s specification, Continuity and ear thing , MCCB mechanism and alignment, Meggaring of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth, All functional tests, Checking for all tightness of nuts and bolts, Alignments of doors etc., interlocking tests
HYDROCON ENGINEERS
Raj Engineering Co.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .