Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
REPAIR/ REPLACEMENT TO LEAKAGE SEEPAGE ROOF TREATMENT, PLASTERING AND MISC WORK AT AOR OF AGE B/R-V UNDER GE (MCTE) MHOW
2026_MES_799605_1
GE(MCTE)/MHOW/61(T) OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (MCTE) Mhow
As per Tender Document
10 documents required · 10 mandatory
₹500
GE (MCTE) Mhow
₹60,000
20 Nov 2026
20 Nov 2026
12 Dec 2026
20 Nov 2026
10 Dec 2026
4 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for taking down existing waterproof treatment of tar felt of any description from roof surface and removing rubbish to a distance not exec 100 mtrs complete all as specified and directed. | 3,000 | Sqm | 100 | ₹3,00,000 |
| 2 | M&L for PCC 25mm thick (1:2:4) type B0 using 12.50mm graded stone aggregate mixed with integral waterproof chemicals mixed in proportion of 200ML/50KG cement as in padding on roof surface for correcting/ making proper slope on roof/ chajja and roof kerbs/ benching complete all as specified and directed. | 130 | Sqm | 101 | ₹13,130 |
| 3 | M&L for Cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed; set jointed neat cement slurry as on roof surface incl cut and polished etc incl 15mm thick cement plaster in CM 1:4, complete all as specified and directed. | 160 | Sqm | 102 | ₹16,320 |
| 4 | Identify the cracks and construction joints, honeycomb areas in slabs/ beams/ columns, shall be chased open into 'U' groove shape and sealed with High strength, fiber based cementitious mortar, Fosroc Renderoc SP40. Providing and fixing 6-8mm dia nozzle along the joints and honeycomb areas after proper surface preparation. The injection of conbextra EP10 through the nozzle till the refusal of the grouting materials complete all as specified and directed. | 120 | RM | 103 | ₹12,360 |
| 5 | Supply & providing water proofing roof treatment with polymeric standard water proofing membrane, having 10 years gurantee for water tightness complete all as specified and described as under:-
(a) Preparation of RCC roof surface and applying one coat of polymeric modified bitumen 85/25 @ 1.2Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/sqm including cleaning surface all as per manufaturer's specification complete all as specified and directed.
(b) Supply & providing water proofing with 3mm thick APP polymeric proofing membrane of 3Kg/Sqm consisting of 100micron HMHDPE film centre core including coating the surface with compatible primer and torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed.
(c) Aluminium bituminous paint @1.10 Kg/Sqm shall be applied over the APP membrane surface.
Note:- The work of water proofing treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. | 2,700 | Sqm | 104 | ₹2,80,800 |
| 6 | M&L for water proofing on roof/parapert with the following steps:
Step I : Surface Preparation:
All loose and de-bonded concrete/ screed, loose particles, dirt & should be removed. Roof substrate must be pressure-washed with water with, a minimum working pressure of 1,400 psi is to be used to and/or remove all dirt, dust, chalking and waster products. Remove algae,mold by using bleach solution or biowash.
Step II : Surface Repair:
Concrete roof screed more than 0.50mm and not giving hollow sound, should be cut and widenin V shape with mechanical cutter in the size (10mm W x 6mm D). Apply a coat of (Dr. Fixit Pidiprime A/ Equivalent make) on the well-prepared groove; allow the coat to dry for 30 minutes before application of (Dr. Fixit PU/ equivalent) seal and withsuitable gun. Allow sealant to cure a minimum 72 hours.
Step III : Screed Repair:
Remove loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jetto remove dirt and loose particles. Brush apply abondcoat of (Dr. Fixit Pidicrete URP mix/ equivalent) in the ratio of 1:1 (URP 1: Cement 1) by volume to makeit lump free slurry when applied on in the pre wet surface. Laid to fall roofscreed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10%/ equivalent byweight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water. Level the repair mortar and finish with trowel. Moist cure should bedone for 7days. Air cure screed for 7days, before application of roof top coatcoating system.
Step IV : Rain water outlets treatment
Hacking and chipping the surface around the rainwater drain outlet up to 25mm in depth. Apply bond coat of Dr.Fixit Pidicrete URP/ equivalent in the ratio of 1:1 (URP 1: Cement 1) by volume over the corners and pipe insert outlet gaps. Filling the gaps around drain mouth with (PMM) polymer modified mortar mixed with Dr. Fixit Pidicrete URP 10%/ equivalent by weight of cement in the ratio of 1:3. Providing & fixing 100mm width 45gsm glass fiber mesh all around the periphery of drain mouth of rainwater outlet sand wiched with Dr. Fixit Roof seal Classic/ equivalent. Apply the second coat of Dr. Fixit Roof seal Classic/ equivalent with an interval if 5-6 hoursall over the rain water outlet. | 300 | Sqm | 105 | ₹31,500 |
| 7 | M&L for cutting/ making grooves/ opening to existing tile/ kota stones joints including cleaning the joints completely using high pressure air blower and providing & applying Nitotile EPW or equivalent hygienic, stain-resistant, with a high degree of resistance to chemical attack, abrasion and impact. Nitotile EPW is a grouting material of highest quality that provides aesthetic effect and durability, it perfectly prevents stains, spillage chemical attack to filled joints of tiles & stones (size of joints -2/3/4mm width x thickness of tiles). Compressive strength (ASTM 579)> 75 N/mm2 (7 days),Shrinkage % (ASTM D 955) < 0.1%,Tensile strength (BS 6319) >10 N/mm2 (7 days), Pot life @ 27oC 45 mins. Maximum & Light Foot traffic 24 hrs. | 1,000 | RM | 106 | ₹1,06,000 |
| 8 | M&L for repair to sunken floor by provide water proofing treatment to sunken floor surfaces of RCC slab by the following specifications as specified and directed.
(a) Demolition of old sunken surfaces complete and cleaniong of all loose particles and apply cement slurry @3.00 kg/ sqm on old surfaces by brushing.
(b) Provide PCC 1: 1.5:3 type A with using 12.5mm graded stone aggregate in slope of average thickness 50mm on sunken floor slab mixed with and including integral water proofing compound manufactured by Dr FIXIT or equivalent as approved, finish the surface even & smooth without using extra cement.
(c) Rendering 15mm thick in CM 1:3 mixed with & including integral water proofing compound on sunken floor and sides of (Vertical surface) sunken portion.
(d) After laying of all sewage/ plumbing pipes with fixtures in position, apply two coats of polymeric based chemical pidifin 2k by pidilite as per manufactures instructions over bottom and sides of sunken portion upto 600mm height, complete all as specified and directed.
(e) Fill the sunken floor with PCC 1:5:10 type E-2 using stone/ brick aggregate. (h) Fixing of 40mm dia CPVC pipe connecting upto bathroom outlet pipe shall be provided to drain out seepage water if any.
(j) Testing of sunken as per specification mentioned in SSR Part-I/ P.S. | 30 | Sqm | 107 | ₹3,210 |
| 9 | M&L for Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6 complete all as specified and directed. | 35 | Sqm | 108 | ₹3,780 |
| 10 | M&L for Glazed Coloured ceramic tiles (textured and designed as required) in vertical surfaces size 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick backing coat in CM 1:3 complete all as specified and directed. | 145 | Sqm | 109 | ₹15,805 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_897139.xls
BOQ • 0.47 MB
TD61T.pdf
Tender Documents • 0.77 MB
PS-61T.pdf
Tender Documents • 0.45 MB
Make61T.pdf
Tender Documents • 0.44 MB
Undertaking61T.pdf
Additional Documents • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .