Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.0 L+₹4.4 L (11.2%)Rejected-Finance C 52 ADG NEI GUWAHATI PRIME APARTMENT FLAT NO 403 GS ROAD CHRISTAN BASTI AMRABATI PATH DISPUR GUWAHATI ASSAM 781005 | GUWAHATI | KAMRUP METROPOLITAN | ASSAM | 781005 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹48.5 L+₹9.0 L (22.7%)Rejected-Finance MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹49.5 L+₹10.0 L (25.2%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NARANGI
GE Narangi C/O 99 APO Guwahati
PROVN OF CERTAIN LBW REVENUE WORKS AT VARIOUS UNITS AND SPL REPAIRS TO BLDG NO T15 AT OLD SIG COY UNDER GE NARANGI.
2020_MES_341045_2
8532/NAR/E8
Open Tender
Civil Works
Works
180 days
GE NARANGI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NARANGI
₹90,000
Yes
27 Jul 2020
21 May 2020
16 Jun 2020
21 May 2020
12 Jun 2020
29 May 2020
60 days
Amount
SCHEDULE 'A' PART-I
Taking down cement plaster on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed
Demolition of brick work, built in cement mortar, including all quoins, arches, pillars including coping etc. complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings in roof or wall covering complete all as specified and as directed.
Dismantling timber scantling under 40 Sqcm in section in fillets, rails, rafter, purlins, post, boarding etc fixed with nails / screw etc complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as specified and as directed.
Taking down roof trusses, coupling rafters of clear span above 4 m & upto 8 m for renewal of any defective members (timber renewed to be measured separately) and reassembling, housing and fixing trusses etc. after repairs including tightening up wedges, cotters bolts etc. complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Taking down chowkats or frames with shutters area exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified and as directed.
Taking down chowkats or frame with shutters area not exceeding 1.5 Sqm each (without taking off shutters from frame) complete all as specified and as directed.
Taking down shutter of any description area exc 1 Sqm but not exc 2 Sqm each complete and refixing in the same opening including shortening height to fit above floor if required complete all as specified and as directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep in soft / loose soil complete all as specified and as directed.
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc 50 m and making good surface in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
Removing excavated soil to distance exc 50 mtr and not exc 250 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed.
Supply and spread clean dry river sand in cable trenches as in cable cushioning including hand punning complete all as specified and as directed. Note : Punned thickness only shall be measured and paid.
M & L for hard core with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed
M & L for plain cement concrete 1:4:8, type D2, (using 40 mm grade stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M & L for plain cement concrete 1:3:6, type C2, (using 40 mm graded stone aggregate) as in surface channel or drain including necessary form work complete all as specified and as directed.
M & L for RCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in lintel band etc including all necessary form work complete all as specified and as directed.
M & L for RCC 1:2:4, (using 20 mm graded stone aggregate ) as in ramp for washing of vehicles complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed.
M & L for brick work with sub class B bricks old size (locally available best quality) straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M & L for half brick work with sub class 'B' bricks old size (locally available best quality) straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and as directed.
M & L for sub class ‘B’ old size, well burnt brick, laid flat in trenches over the cable with length of brick perpendicular to length of cable for protection of LT cable complete all as specified and as directed.
M & L for Cutting chases, pinning in for concealed conduit wiring in brick walls and making good to facings where with cement mortar 1:3 etc, cutting not exc 10 cm girth complete all as specified and as directed.
Use & waste of formwork to edges of concrete ramp exc. 5 but not exc 10 cm wide for fair finished surface of concrete complete all as specified and as directed.
Use & waste of form work to soffits of suspended roof slabs not exceeding 200 mm thick (Horizontal or sloping) rough finished surface of concrete complete all as specified and as directed.
Use & waste of form work to chajja and similar work for fair finished surface of concrete complete all as specified and as directed.
M & L for second class hard wood in scantlings clean sawn timber in framed work complete all as specified and as directed.
S & F second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S & F 35 mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, guaze etc (with sash bar) dividing into square, edges of framing, plain, chamfered or rounded, mitred beads for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and as directed.
S & F 30 mm thick second class hard wood glazed and skeleton window or ventilator shutters, open rebated and prepared to receive glass, guaze, etc., divided in to squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered size of member as per SSR part I Section 8 Clause No. 8.24 (b) complete all as specified and as directed.
S & F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F 150 mm long aluminium anodised barrel tower bolts of extruded sections complete all as specified and as directed.
S & F 100 mm long aluminium anodised barrel tower bolts of extruded sections complete all as specified and as directed.
S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
S & F 100 mm size butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
S & F 75 mm size butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
S & F 150 mm long extruded aluminium alloy handles fabricated type anodised complete all as specified and as directed.
S & F 100 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or aluminum wire staples complete all as specified and directed.
S & F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 completed all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bendings spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mmm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealled) not less than 0.9 mm dia in stirrups, spacers and binders complete all as specified and as directed.
S & F mild steel framed work as in doors or gates of angle or other section such as angles, flat iron , MS plain sheets with gusset plates, rails, braces, hold fasts, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings inclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing completed all as specified and as directed.
S & F rolled mild steel work in tubular trusses including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to IS 1161-1998 complete all as specified and as directed.
S & F expendad metal of weight not exc 4 kg per Sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and as directed.
S & F mild steel windows and ventilator fixed type complete with glazing bars dovetailed of welded ready for fixing wire mesh / glass pane complete all as specified and as directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any approved colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any approved colour having tensile strength of 550 Mpa as in ridge / flusing board of width or girth not less than 610 mm complete all as specified and as directed.
S & F 6 mm thick Asbestos cement corrugated or semi corrugated sheet with side lap, fixed with 'L' or 'J' type cranked hook, bolts, nuts & washers etc. complete all as specified and as directed.
Fixing only 6 mm thick Asbestos cement corrugated or semi corngated sheet with side lap, fixed with 'L' or 'J' type cranked bolts complete all as specified and as directed.
S & F 6 mm thick Asbestos cement two piece adjustable serrated ridge corrugated or semi corrugated sheet with side lap, fixed with 'L' or 'J' type cranked hook, bolts, nuts & washers complete all as specified and as directed. Make: Rhino/Everest/Charminar
M & L for suspended false ceiling using E-grid (exposed ceiling suspension system) of grid size 600 x 600 mm with main runner 38 mm x 24 mm and wall angle 24 mm x 24 mm using 4 mm thick Non Asbestos fiber cement designer board (E-Board classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c, the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjucent wall, flush fitting 1220 mm cross tee to be interlocked between main runners @ 610 mm c/c so as to form 600 x 600 mm grid including painting with two coats of oil bound distemper over a coat of primer before installing it on the grid complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring 20 - 25 mm thick, laid and jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20 mm thick cement screed bed in cement mortar 1:4 complete all as specified and as directed.
M & L for Kota stone slab 20 - 25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick cement screed in cement mortar 1:4, laid in gray cement slurry, jointed & pointed in white cement with pigmement to match the shade of slab complete all as specified and as directed.
M & L for 100 mm thick plain cement concrete 1:2:4, type B2, (using 40 mm graded stone aggregate) as in floor, including finishing the surface of cement concrete by brooming complete all as specified and as directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C2, (using 40 mm graded stone aggregate) as in plinth protection, finished fair and smooth without using extra cement including provision of joints 10 mm wide x 30 mm deep and filling with bitumen mastic joint filling at every 2.4 m length and at corners complete all as specified and as directed.
M & L for 100 mm thick, plain cement concrete 1:4:8, type D2, (using 40mm graded stone aggregate) as in sub base, floor etc. complete all as specified and as directed.
M & L for 40 mm thick plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) in flooring including finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
M & L for forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade `A' complete all as specified and directed.
M & L for forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, on fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement (or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specifed and directed by Engineer-in-Charge. Note : Water proofing compound to be measured and paid separately as "Supply only"
M & L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
M & L for preparation of newly plastered or unplastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M & L for complete removal of existing treatment of old painted plastered or unplastered surfaces of walls, applying thin coat of wall care putty and applying two coats of oil bound distemper over one coat of alkali resitant primer complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of cement based paint including one coat of alkali resistant primer complete all as specified and as directed.
M & L for complete removal of existing treatment of old painted plastered or unplastered surfaces of walls, applying thin layer of wall care putty and applying two coats of cement based paint complete all as specified and as directed.
S & F 3 mm thick sheet glass, ordinary quality and glazing with oil putty / wooden beads in square not exceeding 0.50 Sqm in each pane complete all as specified and as directed.
M & L for preparation of new wooden surface of wood of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M & L for preparation of old wooden surface of wood of any description, not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S & F joint with rubber or fibre board gasket for flanged pipe fittings of 450 mm dia complete all as specified and as directed.
Cutting of existing CI / DI pipes of 450 mm bore and reducing to required length for insertion of new tee, branches (fittings) etc complete all as specified and as directed.
S & F of CI fittings flanged socket, distance plate etc., complete all as specified and as directed.
S & F GI tubing 15 mm bore medium grade ISI marked to wall / celling or laid in floors including complete fittings all as specified and as directed.
S & F GI tubing 25 mm bore medium grade ISI marked laid in trenches including all fittings complete all as specified and directed.
S & F GI tubing 50 mm bore medium grade ISI marked to wall / celling or laid in floors including complete fittings all as specified and as directed.
M & L for cutting, screwing existing steel tubing of bore 50mm dia for alterations or addition necessarily done in position without taking down all as specified and directed.
M & L for cutting, screwing existing steel tubing of bore 15mm dia for alterations or addition necessarily done in position without taking down all as specified and directed. Note: Making hole for inserting steel tubing on wall is included in quoted rate.
S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed.
S & F bib taps 15 mm dia cast copper alloy chromium plated, fancy type with crutch or butterfly handles screwed down for iron pipe or for brass ferrule complete all as specified and as directed.
M &L for stop valves 15mm dia cast copper alloy, fancy type chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and directed.
S & F gun metal gate valve to be fit in 25 mm dia pipe with iron wheel screwed both end for iron pipe and fixed complete all as specified and directed.
S & F gun metal globe or gate valves 50 mm with iron wheel head screwed both end for iron pipe and fixed complete all as specified and as directed.
Taking down carefully aluminium / copper point wiring for light / fan / socket / bell or power point including taking down concealed conduit if any, all fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unheathed FRLS cable, 1100 volts grade IS -694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) in and including PVC condiut concealed and also including sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers for One light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per serial item No 89 here-in-before but One socket outlet 3 pin 5 Amp on independent board complete all as specified and as directed.
All as per serial item No 89 here-in-before but one 3 pin socket outlet 5 amps on the same board with other switches complete all as specified and as directed.
All as per serial item No 89 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable for 6 pin 15 Amp socket outlet on independent board and earth continuity wire with 2.5 sqmm cable complete all as specified and as directed.
M & L for cast Iron / pressed steel terminal boxes 60 mm deep of size 150 mm X 75 mm reactanglar for mounting, switches, sockets, fan regulator, etc. with 3 mm thick plastic laminated sheet cover phenolic cover flush in wall complete all as specified and as directed.
S & F lamp holder ,PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S & F switch, Piano type, 5 Amp, 240 Volts single pole one way (ISI marked) complete all as specified and as directed.
S & F Socket outlet 2 in 1, 3 Pin 5 Amp Flush type 240 volts complete all as specified and as directed.
S & F switch socket combination 2 in 1, 5 Amp flush type complete all as specified and as directed.
S & F switch socket combination, 5 in 1, 5A / 16A amp flush type complete all as specified and as directed.
S & F ceiling rose, 3 phase / PVC / polycarbonate, isolated body complete all as specified and as directed.
S & F electronic stepped type electronic fan regulator, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs, factory made, sheet steel distribution boards, double door, protection class IP-42, SPN 8 Ways suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar, complete all as specified and as directed.
M & L for sub main wiring with two runs (P-N) of single core 4.0 Sqmm (nominal area) FR PVC insulated and unsheathed copper conductor cable 1100 volts grade having multi-stranded copper conductor with earthing cable of FR PVC insulated and unsheathed multi-stranded copper conductor green colour of size 4.0 sqmm single core as earth continuity wire drawn through adequate size PVC non-metallic conduit complete all as specified and as directed. Note : Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm earth continuity conductor and one run of PVC conduit shall be measured as one run length.
Taking down old unserviceable sub main wiring and M&L for Sub main wiring with two runs of 6 Sqmm size main cable of single core PVC insulated but unsheathed FRLS cable size with multi standed copper conductors, 1100 volts grade, IS-694 marked with the one run of 6 Sqmm size of earth continuity conductor of similar type cable all drawn through and including suitable size PVC conduit and fittings/accessories all fixed to the surface of wall/ceiling complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 4 core laid in trenches /floor or fixed on wall / pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
S & F LED box type fitting pre-wired including LED tube 1 x 20 W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed. Make:- Jaguar Model-LGLZ01X020XC/ LGLZ01X020XN/LGLZ01X020XW or equivalent model of make Philips /GE/Crompton
S & F in repairs, decorative hexagonal bulk head LED luminaire 10 Watt, 6000 K with IP 66 Protection Model HEXAFT10WLED857SSYMBOPC of Make Havells or equivalent model of make Philips /GE/Crompton
S & F MCBs, SPN 40 to 63 Amps, 10 KA , IS / IEC 60898-12002 marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as directed. Make:- Legrand/Havells/ Schnider
S & F MCBs, SP 6 to 32 Amps, 10 KA , IS/IEC 60898-12002 marked fixing in DBs (DBs catered separately in this Schedule) Make:- ABB/Legrand/Havells/ Schnider
Supply, fixing and testing of Storage type water heater of capacity 25 Litres , five star rated, 230V ,maximum power consumption -2kW, polymer protective coating technology for inner container and titanium enamelled heating element vertical wall mounting complete with smart bath logic function all accessories and PVC connection pipe 15mm bore 450mm long 2 Nos for hot and cold water supply, complete all as specified and directed Make:- Racold Model : Eterno 2 or Equivalent from Havells or Cromption Greaves
S & F car washing system 3 Phase ,50Hz , operating voltage 415 Volt of capacity 3HP having triple plunger washer for high pressure washing, direct driven , positive suction , and motor speed 1440 rpm base mouting including necessary PCC 1:2:4 type B-2 in foundation, suitable size nuts, bolt washer and foot valve strainer complete all as specified and directed. Make : ATS Elgi ,Model: HL 03 045 or equivalemt make as approved by GE.
S & F heavy duty hose pipe of size 20 mm complete all as specified and directed.
S & F high pressure nozzle of size 20 mm complete all as specified and directed.
S & F PVC insulated and PVC round sheathed copper conductor multistranded flexible 4 Sqmm 3 core complete all as specified and as directed.
S & F sheet metal enclosure of thickness 2 mm with all electrical connection to be fixed on wall including following accessories complete all as specified and as directed. (a) MCB 4P 32 Amps ,C curve, 10kA breaking capacity- 01 Nos (b) MCB 3P 32 Amps, C Curve , 10kA breaking capacity-01 Nos © VAF +PF meter of accuracy CI-1 , flush type , input voltage measurement range 50-520 VAC (P-P)- 01 Nos (d) Direct-on-line starter, 415V,50Hz, 3-Ph ,with single phase protection having max motor output 10HP and relay current range (9-15)A - 01 Nos. (e) Indoor tape insulated ring type low tension CT 50/5A- 03 Nos (f) LED indicator for RYB - 01 Set
Supplying, installing testing and commissioning of bulk type Woltman water meter, having removal mechanism, horizontal interferential multjet type with magnetic drive and dry dial suitable for ambient 50 dgree Celsius temperature duly sealed against tempering complete with flanges at both ends suitable for 450 mm dia pipe, (size of meters not less than 400 mm dia) complete all as specified and as directed. Note : (i) The bulk water meter shall be suitable for water, minimum, maximum and transitional flow conforming to IS 2373 or ISO - 4064 as applicable and shall be installed so as to have laminar flow. (ii) Pressure rating (maximum working pressure 16 Kg per sqcm) suitable for forward and reverse flow. (iii) The cost of cutting existing pipe, welding flanges, excavation, fittings. (i.e, tapers, sockets etc) will be measured and paid separately. (v) Metering accuracy shall be ± 2%. (vi) Guarantee period shall be 36 months. (vii) Manufacturers test certificate duly signed by a Govt recognized test lab shall be submitted by contractor.
S & F open wall type submersible pump set of capacity 3 HP / 2.2 kw horizontal type discharge 590 lpm at 18 mtr head of size 65 x 50 mm with electric driven, AC 3 phase, 415 V, 50 Hz, complete all as specified and as directed. Make : Crompton / KSB/ Kirloskar
S & F DOL starter starter suitable for 3 HP, AC-3 duty, 415V, 50 Hz, 3 Ph, relay range 15.5 - 8 A complete all as specified and as directed. Make : Havells, car Part No CS 90947 or equivalent in BHC / C & S
S & F PVC insulated three core submersible flat cable with copper conductor 1100V confirming to IS 694/1990 of 4 Sqmm size complete all as specified and as directed.
M & L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm, buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
M & L for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected to copper strip 20 X 3 mm as earth lead by means of bolts nuts, check nuts and washers of brass and as shown in electrical plate No 3 connected to earth test point including necessary excavation any type of soil, RCC chamber cover plate, wire mess, funnel, test point, 20 mm dia GI pipe light grade for protection pipe and watering etc complete and testing on completion. Note : (i) Copper strip upto 7.5 Rm will be included in the item rate .
M.P.SUPPLY
M/S Bharat Construction
M/S SHARMA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .