| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹17.4 L+₹8,509.55 (0.49%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | L3₹17.9 L+₹59,042.42 (3.40%)Rejected-AOC | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 4 | L4₹18.0 L+₹64,059.19 (3.69%)Rejected-AOC | L4 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 5 | L5₹19.9 L+₹2.5 L (14.6%)Rejected-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L5 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
17 Jan 2024, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
REPAIRS MAINTENANCE WELDING PAINTING LETTERING SERVICES TO EXISTING LT PANELS FEEDER PILLAR BOXES POLES AND ALLIED ITEMS AT INS RAJALI ARAKKONAM
2023_MES_633521_1
8331E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer M NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹40,000
Yes
5 Feb 2024
19 Dec 2023
19 Jan 2024
19 Dec 2023
17 Jan 2024
3 Jan 2024
Amount
Material and labour for cleaning and preparation of old painted surfaces and painting with one coat of aluminium paint on LT steel tubular poles upto 9 mtr height and including clamps and street light brackets complete all as specified and as directed.
Material and labour for cleaning and preparation of old painted surfaces and painting with one coat of aluminium paint on LT steel tubular poles upto 11 Mtr height and including clamps and street light brackets complete all as specified and as directed.
Material and labour for writing pole number on any type of pole, painted with thick paint, bold and solid with white colour letters over black colour circular base complete all as specified and as directed .
Supply and fix for MCB SP 240V, 10KA 'C' curve 5 To 32 Amp Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed.
Material and labour for following MCCBs with adjustable thermal and fixed magnetic setting of ICS = 100% ICU and including additions / altertions to existing MCCB places of the panel for properly fixing in the panel boards/ outdoor feeder boxes etc., located at various locations, reconnecting In/ Out going bus bar or cable connections with suitable rating / size lugs, extended terminals as per site requirement including taking down old unserviceable/ burned MCCB and making good disturbed panel surfaces complete all as specified and as directed.
MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
MCCB 250 Amps, 36 KA 3 pole
MCCB 200 Amps, 36 KA 4 pole
MCCB 160 Amps, 36 KA 4 pole
MCCB 125 Amps, 16 KA 3 pole
MCCB 100 Amps, 16 KA 3 pole
Material and labour for four pole power contactors 80 Amp MCX 13 including additions / altertions to existing contactor places of the panel for properly fixing in the panel boards/ outdoor feeder boxes etc, located at various locations, reconnecting In/ Out going bus bar or cable connections with suitable rating / size lugs, extended terminals as per site requirement including taking down old unserviceable/ burned contactor and making good disturbed panel surfaces complete all as specified and as directed .
Material and labour for removing of existing loop cable from under ground, after rectificattion of fault /damaged cable portion and rearrange the cable to same existing location with proper connections including lugs, nuts, bolts including PCC works etc., complete all as specified and as directed.
Supply,Fixing and Testing LED street light luminaire fitting of not less than 60 Watt, Luminaire fitting of not less than IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Note:(i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. (ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer.
Material and labour for LED 170 wattage flood lights luminaire fitting of not less than IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 4 Kv input and 10 KV out put complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed.
Material and labour for LED 210 watt flood lights luminaire fitting of not less than IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 4 Kv input and 10 KV out put complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed.
Material and labour for LED 100 wattage flood lights luminaire fitting of not less than IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 4 Kv input and 10 KV out put complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces complete all as specified and directed.
Material and labour for LED post top lantern 40 wattage fitting of IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 4 Kv input and 10 KV out put complete including taking down the old unserviceable/damaged post top lantern fittings and making good disturbed surfaces complete all as specified and directed.
Material and labour for LED bollard with opal crystal difuser 9 watt of IP rating 65 protection comprises of Pressure die cast Aluminium housing powder coated and making good disturbed surfaces complete all as specified and directed.
Material and labour for LED spike light 9 watt 230v 50 Hz of IP rating 65 protection comprises of high quality tuoghened glass diffusers and making good disturbed surfaces complete all as specified and directed.
Material and labour for LED red colour Obstruction twin light 9 watt 230v 50 Hz of IP 65 protection comprises of Pressure die cast Aluminium housing powder coated and making good disturbed surfaces complete all as specified and directed.
Demolition and dismantling of concrete of any description standalone solar street light pole foundation, coping etc., complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) for foundation of pipe fame of any size complete all as specified and as directed
Material and labour for PCC for coping round/ cylindrical type for existing poles whereever necessary, 1:3:6 type C-1 (Using 20mm graded stone aggregate) complete all as specified and as directed.
Supply and lay pipe galvanised iron tubing light grade of 40 mm dia in trenches/under road or floor/on wall / near pole/panel etc all as per site requirement complete all as specified and directed.
Supply, Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 65 fabricated by CPRI certified panel manufacturer including suitable terminal TPN 10 KA SMC Connector ( for 3 Phase Cable Line IN & OUT) and provision of dimrail for mounting 3 Nos MCB SP including S&F 01 No MCB 20 Amp SP C curve canopy weather proof, hinged door with allen key pad side locking system for fixing on PCC / Steel Poles in and including necessary MS Clamps of suitable shape and size with nut, bolts and washers as per site requirement incl taking down unserviceable junction box complete all as specified and directed by Engineer-in-charge. Note - (1) The cost deemed to be included in the quoted rate for reconnecting Old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect where ever required as per site requirement complete all as specified and directed.
Taking down corroded sign board of frame MS pipe with MS sheet of various sizes from the existing position of different location complete including making good the disturbed surface to match with the existing surfaces of the area in all respect complete all as specified and as directed.
Supply, fabricate and polishing stainless steel board stand or frame work with following dia SS heavy pipe (SS 304 Grade) as per site requirement for fixing ACP (Aluminium Compost Panel) of various sizes duly lettered with nuts, bolts or screws or any other suitable arrangement on frame properly complete all as specified and as directed Note: Earth work PCC work and ACP sheet shall be measured and paid separately under relevant schedule item here-in-after.
50mm dia
20mm dia
Supply and fix 3mm thick ACP sign board sheet of various sizes with all required items of work including writing details of installation/ mechinary details etc with both side or one side vinyl pasting on radium sticker letters/ sketch within the SS frame or wall complete all as specified and as directed. Note: SS stand and frame whereever necessary shall be measured and paid seperately under relevant schedule Item here-in-before.
Supply, fabricate and fixing SS Ball of dia not less than 50mm on SS stand complete all as specified and as directed.
Material and labour for painting to existing LT feeder pillar box/panel boards after preparing/ scraping the surface with emery sheet in all respect for making smooth surface including painting with two coat of exterior enamel paint water proof suitable for existing LT feeder pillar box/panel board surfaces including writing in coming and out going details as per site requirement and as specified complete all as specified and as directed. Note: White washing to copping/pedestal of LT feeder pillar box / panel board shall be measured and paid separately.
Material and labour for welding works to existing LT feeder pillar box/panel board doors including removing broken hinges and supply and fixing new heavy duty hinges as per existing type and qty including writing in coming and out going details as per site requirement and painting with synthetic enamel paint over redoxide on the welded surfaces to make good the disturbed surface and match with existing tint complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor 6 sq. mm two core complete all as directed by Engineer-in-charge.
Taking down 16 and 25 sqmm cable of any type and make complete all as specified and directed.
Supply & laying for 16 sqmm 4 core XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor for replacement of un serviceable portion of cable,connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel/joints/poles including testing complete all as specified and directed.
Supply & laying for 25 sqmm 4 core XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor for replacement of un serviceable portion of cable,connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel/joints/poles including testing complete all as specified and directed.
Relaying of serviceable cable of size 16 sqmm 4 core complete all as specified and directed.
Relaying of serviceable cable of size 25 sqmm 4 core complete all as specified and directed.
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for taking up / laying cable etc and getting out for soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as specified and directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Relaying of reusable bricks as obtained from item ser No 33 .00 here-in-before complete all as specified and directed.
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and directed.
Spreading riddled earth as obtained from item No. 33.00 here-in-before in cable trenches all as specified and directed.
Taking down unserviceable LED light fittings of any watt and type from existing position on pole/ wall/ tower/gate, complete for and including repair and refixing in existing position after repair all as specified and as directed Note: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as ‘ Supply only’ under relavent item here-in-after ii) Labour cost for replacing spare parts,removing unserviceable parts, dismantling light fitting and refixing are deemed to be included in the quoted rate.
Supply only oudoor drivers and SPD following wattage for flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement all as specified and directed.
Out door type drivers suitable for 30 watts to 75 LED lights.
Out door type drivers suitable for 120 t0 200 watts LED lights.
Surge protection devices not less than 5 KV suitable for LED light fittings up to 75 watts.
Surge protection devices SRPS-HP-5 K -440 suitable for LED light fittings 75 watts to 150 watts.
SHRI S SANTHAKUMAR
N SRINIVASAN
Green Ray Technologies
rc enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .