| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.0 L+₹1.3 L (6.06%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.2 L+₹3.5 L (16.8%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹27.8 L+₹7.1 L (34.1%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹31.1 L+₹10.4 L (50.3%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹41.6 L
EMD Value
₹83,260
Closing Date
18 Jan 2024, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR MAINTENANCE OF CONTROL WIRING CONTROL PANEL CONNECTED WORKS OF VARIOUS AC PLANTS UNDER GE (U) PM DELHI CANTT-10.
2023_MES_633855_1
GE(U)/PM/D-61/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Delhi Cantt-10
MES contractor enlisted under class D cat b(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class a
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹83,260
Yes
5 Mar 2024
21 Dec 2023
20 Jan 2024
21 Dec 2023
18 Jan 2024
4 Jan 2024
Amount
Supply and fixing in replacement of shock absorbing rubber pads at the bottom of the AHU unit for absorbing shocks and vibrations, heavy duty of suitable size as per ground requirement complete all as speicifed and directed.
Supply and fixing in repair bimetallic thermal overload relay, 9 to 15 Amps complete as specified and directed. (Make -: L&T/Siemens/Legrand/ ABB/ C & S)
Supply and fixing in repair bimetallic thermal overload relay, 14 to 23 Amps complete as specified and directed. (Make -: L&T/Siemens/Legrand/ ABB/ C & S)
Supply and fixing in repair bimetallic thermal overload relay, 20 to 33 Amps complete as specified and directed. (Make -: L&T/Siemens/Legrand/ ABB/ C & S)
Supply and fixing in repair bimetallic thermal overload relay, 24 to 40 Amps complete as specified and directed. (Make -: L&T/Siemens/Legrand/ ABB/ C & S)
Supply and fixing in replacement of multifunction electronic timer ( 0 to 60 Sec) type Series 525 complete all as speicifed and directed. (Make:- Siemens/ L&T/ ABB)
Material and Labour for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed. (Make ;- Tata/ Jindal/ Sail)
Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-32 including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. (Make :- L&T/Siemens/ ABB/ C & S)
Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-25 including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. (Make :- L&T/Siemens/ ABB/ C & S)
Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-18 including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. (Make :- L&T/Siemens/ ABB/ C & S)
Supply and fixing in replacement over load relay 30-50 Amps complete all as specified and directed. (Make -: L&T/Siemens/Legrand/ ABB/ C & S)
Supply & fixing in replacement brass terminals of follwing ways complete all as specified and directed .
(h) Timer Micron Series - 01 No. (i) Single Phase Preventer - 01 No. (Make :- L&T/ Siemens/ Legrand/ ABB/ C&S) (j) Push button Start/Stop with Elements - 02 Nos, (k) Aux. Blocks 1 No+1 Nc - 1 Set. (Make :- Universal/ Switchgear/ Dvepl/ PSC/ GM & G/ ITE Gurgaon/ Neptune/ Hensel/ Indo Asain/ Standard/ Hevells/ C&S Electric/ Bhandari/ Shalabh/ Adhunik Switchgear/ HPL/ Seepl/ ABB/ L&T/ Siemens)
(h) Timer Micron Series - 01 No. (i) Single Phase Preventer - 01 No. (Make :- L&T/ Siemens/ Legrand/ ABB/ C&S) (j) Push button Start/Stop with Elements - 02 Nos, (k) Aux. Blocks 1 No+1 Nc - 1 Set. (Make :- Universal/ Switchgear/ Dvepl/ PSC/ GM & G/ ITE Gurgaon/ Neptune/ Hensel/ Indo Asain/ Standard/ Hevells/ C&S Electric/ Bhandari/ Shalabh/ Adhunik Switchgear/ HPL/ Seepl/ ABB/ L&T/ Siemens)
(h) Timer Micron Series - 01 No. (i) Single Phase Preventer - 01 No. (Make :- L&T/ Siemens/ Legrand/ ABB/ C&S) (j) Push button Start/Stop with Elements - 02 Nos, (k) Aux. Blocks 1 No+1 Nc - 1 Set. (Make :- Universal/ Switchgear/ Dvepl/ PSC/ GM & G/ ITE Gurgaon/ Neptune/ Hensel/ Indo Asain/ Standard/ Hevells/ C&S Electric/ Bhandari/ Shalabh/ Adhunik Switchgear/ HPL/ Seepl/ ABB/ L&T/ Siemens)
(h) Timer Micron Series - 01 No. (i) Single Phase Preventer - 01 No. (Make :- L&T/ Siemens/ Legrand/ ABB/ C&S) (j) Push button Start/Stop with Elements - 02 Nos, (k) Aux. Blocks 1 No+1 Nc - 1 Set. (Make :- Universal/ Switchgear/ Dvepl/ PSC/ GM & G/ ITE Gurgaon/ Neptune/ Hensel/ Indo Asain/ Standard/ Hevells/ C&S Electric/ Bhandari/ Shalabh/ Adhunik Switchgear/ HPL/ Seepl/ ABB/ L&T/ Siemens)
Material and labour for control wiring with 6 core X 1.5 sqmm sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 complete all as specified and directed (Make :- Finolex/ Havells /Polycab)
Supply & fixing in replacement single phasing preventer type VSP2 complete all as specified and directed. (Make:- Minilec/ L&T/ Siemens/Legrand/ ABB/ C & S)
Supply, Laying, jointing and testing of under electric cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed. (Make :- RR Kabel/ KEI/ Polycab/ Hevells/ Finolex)
4 core 10 Sqmm
4 core 16 Sqmm
4 core 25 Sqmm
3.5 core 35 Sqmm
3.5 core 50 Sqmm
3.5 core 70 Sqmm
3.5 core 95 Sqmm
Material and labour for control wiring with 4 core X 4 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed. (Make :- Finolex/ Havells/ Polycab) (PVC Conduct :- Finolex/ Suprenle/ Presto Plast)
Material and labour for control wiring with 4 core X 6sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 40 mm dia as per IS 694 complete all as specified and directed (Make :- Finolex/ Havells/ Polycab) (PVC Conduct :- Finolex/ Suprenle/ Presto Plast)
Material and labour for control wiring with 2 core X 1.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed. (Make :- Finolex/ Havells/ Polycab) (PVC Conduct :- Finolex/ Suprenle/ Presto Plast)
Material and labour for control wiring with 2 core X 2.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed (Make :- Finolex/Havells/Polycab) (PVC Conduct :- Finolex/ Suprenle/ Presto Plast)
Supply and fixing in replacement indicator lamp assembly complete LED type suitable for the existing system supply voltage 230V / 440V AC complete all as specified and directed. (Make:- MIMIC CONTROL/ GE CONTROLS / RR MICRO / L&T / SIEMENS/ BCH/ SCHNEIDER)
Supply and fixing in replacement Galvanised iron strip 32X6 mm as earth continuity conductor including fixing arrangement on suitable size insulator complete all as directed.
Material and labour earthing complete with GI plate electrode of size 600 x 600 x 6 mm thick bured directly in ground vertically at a depth not less 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 1.5 cm thick packed layer of charcoal of dust and common salt filling in alternate layers and making electrode connection by using GI strip of size 32X6 (up to 7 meter GI strip included) mm by means of bolts nuts check nuts and washers made of brass and earth strip protected by light grade 40 mm dia GI Pipe upto test point and connected to main switch board are main controlled board with provision of GI pipe medium grade 20mm bore for watering including funnel wire mass RCC pit cover and PCC Chamber pit with 1:2: 4 type C2 (including excavation earth work) all as specified and shown on plate No 5 of SSR Part-1.
Supply, install, testing and commissioning in replacement of Duct insulation with 25mm thick Nitrile Rubber insulation of class "o" fire retardant with Mechanical protection over insulation with fiber glass cloth & UV paint (for exposed duct) for Ducts installed outside, (exposed to sunlight) complete all as specified and directed.
Supply and fixing in repair MCB TP 63 Amps, capacity 10 KA, C curve including taking down old unsv one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply and fixing in repair MCB TP 40 Amps, capacity 10 KA, C curve including taking down old unsv one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 4 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and directed . (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 4 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 4 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 4 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 200 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed . (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 250 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply, Installation , Testing and commissioning in repair of perfabricated type cable tray of size 45mm wide x 50mm x 1.6mm fabricated out of perforated hot dip galvanized sheet of minimum 1.6mm thick with 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed.
All as per Item No.40.00 above but of size 75mm wide x50mm x 1.6mm complete all as specified and as directed.
All as per Item No.40.00 above but of size 150mm wide x50mm x 1.6mm complete all as specified and as directed.
Supplyand fixing in replacement rubber mat LT 1.1KV volt grade 1mtrx 2mtr x 10mm
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed .
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 35 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 75 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 95 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 120 Sqmm complete all as specified and directed.
Supply & fixing in replacement copper lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed.
Supply & fixing in replacement copper lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed.
Supply & fixing in replacement copper lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed.
Material and labour for maintenance of AHU supply panel / feeder pillar/LT panel indoor/outdoor type including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends fresh and supply and crimping new thimbles/lugs and fixing the cable on bus bar/MCCB/Main switch/MCB including providing new nut bolts and washer if required greasing the doors of feeder pillar/LT panel outdoor/indoor type complete all as specified & directed.
Material & Labour for providing and fixing sign boards of stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement
Supply and fixing Retro Reflective Sign Board of Material Acrylic, Feature having, High Visibility,Weather Resistant,WaterProof Type Micro Prismaticshall be fixed on sign boards stainless steel with blue color in backgound and letters in white colour as directed and specified and as directed.
Material and labour for servicing of Steel rolling shutters with gear operated type with bevel gear box and crank handle as specified including changing of top cover, anchoring rod,gear of required size with applying one coat of primer and paint complete all as specified and directed.
Material and labour in replacement Steel rolling shutters, without ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type having Thickness of laths in 1.00 mm as specified and diected .
Material and labour for insulation of variable sizes Chilled water pipe with insulating with closed cell Nitrile Rubber insulation of 25mm thickness and of density 40-42 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C. Nitrile insulation shall be apllied after pressure testing of pipe line and shall be fixed with OEM recomended Rubber based adhesive. The chilled water pipe line shall be finnaly wrapped with 7 milli fiber glass cloth and finally apply two coats of UV paint matching with building colour or as per Engr-in-charge.
Supply and fixing in replacement of Fountain light F-18 A, 24 V, 3 W, Ballast - RGB, type of material SS-304 of model equivalent to as per existing complete all as specified and directed.
Supply and fixing in replacement of Cable 1.5 Sqmm, 3 Core of (Make :- Finolex/ Havells/ Polycab)
Supply and fixing in replacement of Anlge adjustable stand for light (SS 304)
Supply and fixing in replacement of water proof jointing kit of under water cables.
Supply and fixing in replacement of VFD of follwoing capacity motor with technical specifications as under:- Input Phase:- Three Phase 380 V-480 V AC Input Frequency:- 50 Hz - 60 Hz Body Material :- PLASTIC IP -20 Chassis Display :- Digital Application:- MOTOR Motor RPM:- 1440 RPM Input Type Digital Input Output Phase Three Phase
2 HP Motor VFD
3 HP Motor VFD
5 HP Motor VFD
7.5 HP Motor VFD
10 HP Motor VFD
15 Hp Motor VFD
Material and labour for rectification, maintenance of addressable zones, searching the faults, up/down loading software of main control panel at wardec and reprogramming entire system and testing by authorized Technical Engineer of OEM complete all as directed by Engr-in-charge. and including Inspection, testing and commissioning of complete fire alarm system installed done by authrized OEM of Honywell manufacturer only all as required complete all as specified and directed.
Supply, fixing, commissioning and testing of automatic Floating Sensitivity type Analog addressable Acclimate Photo thermal smoke detector with mounting based LED, Address Switch from 01-159 , to programme the detectors, complete as required. (In Changing Environment Area) ul- 7th edition including taking down old unserviceable one complete all as specified and directed. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
Supply, fixing, commissioning and testing of analog addressable Rate of Rise Cum Fixed temperature detector with mounting based LED, Address Switch from 01-159 , to programme the detectors complete as required. Ul- 7th edition including taking down old unserviceable one complete all as specified and directed. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
Supply,fixing,testing and commissioning of addressable type fault for isolating module shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model) including taking down old unserviceable one complete all as specified and directed. (Make: - NOTIFIER GST/APPOLO/ EDWARD/HONYWELL).
Supply, installing, testing and commissioning in replacement factory made and tested LT Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic copper bus bars TPN of capacity 200 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 2.00 mm thick CRCA mild steel sheet and mild steel & Mounting Channel frame work made out of 75 mm ), front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:-
OUTGOINGS :- (i) MCCB 125 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 01 Nos. (Make :- Havells/ ABB/ L&T/ Siemens/ Legrand) (ii) MCCB 100 Amps 16 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 02 Nos. (Make :- Havells/ ABB/ L&T/ Siemens/ Legrand) Star Delta Starter 20 HP Each having the following :- ( AHU 32000 CFM ) - 02 Nos. (a) MCCB Motor Duty 63A 50 KA 3 Pole C Curve- 01 No (b) Contactor 50 A TP (Main & Delta) - 02 Nos (Make :- Havells/ C&S/ Eelctric/ HPL) (c) Contactor 25 A TP (Star) - 01 No. (Make :- Havells/ C&S/ Eelctric/ HPL) (d) Bi Metal Over Load relay 14-23 A - 01 No. (Make :- L&T/Siemens/ ABB/ C&S) (e) Star delta timer Micron Series - 01 No. (f) Digital Amp Meter (0-30A) - 01 No. (g) CT 30/5A - 01 No. (h) Single Phase Preventer - 01 No. (Make :- L&T/ Siemens/ Legrand/ ABB/ C&S) (i) Push button Start/Stop with Elements - 02 Nos, (j) On, Off, Trip indicating Lights LED type 220 V AC- 1 Set. (Set of three). (k) Aux. Blocks 1 No+1 Nc - 1 Set. (Make :- Universal/ Switchgear/ Dvepl/ PSC/ GM & G/ ITE Gurgaon/ Neptune/ Hensel/ Indo Asain/ Standard/ Hevells/ C&S Electric/ Bhandari/ Shalabh/ Adhunik Switchgear/ HPL/ Seepl/ ABB/ L&T/ Siemens)
Servicing through OEM of Refrigerator of Capacity and make as under including detecting the leakage of gas and cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed . Note :- Servicing shall done only through OEM authorised person and all regular spares and gas charging shall consider in above quoated rates.
Deep freezer Elanpro Model EGN1410C
Medical refrigerator (Make :- Gogrej)
Material and labour for pipe earthing (PIP) comprising of GI 80mm Dia x 3 Mtr with one bag of BFC (50 Kg) as per IS 3043-1987 tubing filled with jelly earthing compound duly inserted in soil boring of 100mm bore filled with back filled compound including fibre chamber cover 1x1feet openable type complete all as specified and directed. NOTE:- Contractor shall submit reports before load balance and after load balance as per format given by the Engrin-Charge complete all as specified & directed, falling Which no Payment against this item shall be made . and On testing after completion, if the earth resistance < 2 Ohms is not obtain earthing will be rejuvenated at no extra cost till the desired earth resistance is obtain.Make JMV/ SN Engineering/True Earthing
P S TRADERS
M P TYAGI ENGINEERS AND CONTRACTORS
Shiv Enterprises
YASHVI ENGINEERS
R.P. Enterprises
Flint India
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .