Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 LQualified Make: ceasefire
Model: CF-000792G1 602 DOLI CHAMBERS 06TH FLOOR BRAHMAKUMARIS MARG NEAR STRAND CINEMA COLABA MUMBAI CITY 2829 400058 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | Make: ceasefire
Model: CF-000792G1 | L1 | Qualified | |
| 2 | Disqualified Make: FireTrace
Model: Current Model D 822 1 FLOOR SARASWATI VIHAR PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Make: FireTrace
Model: Current Model | - | Disqualified | |
| 3 | Disqualified Make: LIFEGUARD
Model: LIFEGUARD & LG-3742 B 38 MANGOLPURI INDUSTRIAL AREA PHASE II DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Make: LIFEGUARD
Model: LIFEGUARD & LG-3742 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 Oct 2018, 9:00 amClosed
Fixed Clean Agent Gas based Fire Suppression System Fixed Clean Agent Gas Based Fire Suppression System ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Clean Agent Gas based Fire Suppression System suitable upto 2 metre cube volume Designed to fight fires that occur in the enclosed space of electric panels/closed cabinets/Racks The system's split second detection and activation ensures that the fires are killed in the nascent stage inside the most vulnerable spaces * Types of Electrical or Server Cabinets (Construction) Open Cabinet with natural Airflow * Type of Clean agent with zero ODP(ozone depleting potential) as per NFPA 2001 to be used for fire suppression HFC 236fa * 1/5 Clean Agent listing UL * CONSTRUCTIONAL Container (Containing the clean agent) BS EN 3-8 * Electrical non conductive Clean Agent Type Yes * Clean agent Capacity of cylinder in Kg 2 * Length of Heat Sensing Tube (HST) made of special modified polymide (PA) in (meter) approved by LPCB/UL LISTED 10 * Internal Diameter of Heat Sensing Tube 4mm * Out side diameter of heat sensing tube 6mm * Prepressurised Tube Heat Sensing Tubing should be pressureized with dry nitrogen gas confirming to IS: 1747 and connected to an extinguishing agent container via a pressure release valve. * Pressure Valve Direct low pressure type with inbuilt pressure gauge
integrated ball valve for open/close within the valve body. * Reed switch to monitor the valve position using the reed switch relay to indicate valve open/closed position With * Number of outlets to connect the heat sensing tube Two * Valve operation Pneumatic * Monitoring Panel An audio visual monitoring panel Micro controller based design to check the health of the system and the pressure in the tube * Power back up for Monitoring Panel 12V
7.2 Ah SMF batteries (2 Nos) * Indication on Ac Power ON
system * 2/5 Monitoring Panel ON
system discharge
valve closed/open
Pressure Healthy
Battery Low indication by LED indicator Third Party Intigration facility to intigrate with other fire safety device like smoke detection system panel etc Yes * Electric Buzzer 50 dB piezo electric buzzer * Pressure switches to sense the drop in pressure Yes * Option to connect upto 4 systems in one panel true * If not connect 4 system in one panel please declare NA * Suitable valve for closing & releasing Yes * Straight connectors elbow connectors/T connectors for connecting HST in case wherever required Yes * End of line adapter Yes * End of line plug Yes * Conventional electric sounder suitable to operate between temperature -20⁰C to +60⁰C
with a sound of minimum 60 decibles with variable tones in Red Colour and IP-66 Rated With * PERFORMANCE Ozone Depleting Potential Zero * HST Tube type multi layer and UV protected * Max Working Pressure 20 Bar * Burst Pressure at 20 ⁰C 108 * Operating Temperature range shall be -20⁰ C to 60⁰ C -20⁰ C to 60⁰ C * System operating 15 bar * 3/5 pressure CERTIFICATION Complete system testing and certification LPCB Standard LPS 1666:Issue 1.0 LPCB Standard LPS 1666:Issue 1.0 Test report of the Heat sensing tube Yes * Marking of OEM Supplier Name & year of production on the tube Yes * Valve Certification TPED certificate for valve in conformity to EN ISO 10297:2006/Pi/CE Marked * For panel having ventilation or exhaust fan adequate safety factor for clean agent as per LPS 1666 to be provided Yes * System operation and maintenance manual to be submitted along with the supplies Yes * Design lifespan period (Min 5 years) 10 * Test Report No and Date - * Name and Address of the Lab - * Test Reports to be furnished to the buyer on demand Yes * Warranty of the complete system (years) 2 1
2
3 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Supriya Kumari 734421
Air Force Station
Bagdogra 1 15
655432
GEM/2018/B/92984
Fixed Clean Agent Gas based Fire Suppression System
15 days
West Bengal; Darjeeling
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Fixed Clean Agent Gas based Fire Suppression System Fixed Clean Agent Gas Based Fire Suppression System ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Clean Agent Gas based Fire Suppression System suitable upto 2 metre cube volume Designed to fight fires that occur in the enclosed space of electric panels/closed cabinets/Racks The system's split second detection and activation ensures that the fires are killed in the nascent stage inside the most vulnerable spaces * Types of Electrical or Server Cabinets (Construction) Open Cabinet with natural Airflow * Type of Clean agent with zero ODP(ozone depleting potential) as per NFPA 2001 to be used for fire suppression HFC 236fa * 1/5 Clean Agent listing UL * CONSTRUCTIONAL Container (Containing the clean agent) BS EN 3-8 * Electrical non conductive Clean Agent Type Yes * Clean agent Capacity of cylinder in Kg 2 * Length of Heat Sensing Tube (HST) made of special modified polymide (PA) in (meter) approved by LPCB/UL LISTED 10 * Internal Diameter of Heat Sensing Tube 4mm * Out side diameter of heat sensing tube 6mm * Prepressurised Tube Heat Sensing Tubing should be pressureized with dry nitrogen gas confirming to IS: 1747 and connected to an extinguishing agent container via a pressure release valve. * Pressure Valve Direct low pressure type with inbuilt pressure gauge | - | - | - |
| integrated ball valve for open/close within the valve body. * Reed switch to monitor the valve position using the reed switch relay to indicate valve open/closed position With * Number of outlets to connect the heat sensing tube Two * Valve operation Pneumatic * Monitoring Panel An audio visual monitoring panel Micro controller based design to check the health of the system and the pressure in the tube * Power back up for Monitoring Panel 12V | - | - | - |
| 7.2 Ah SMF batteries (2 Nos) * Indication on Ac Power ON | - | - | - |
| system * 2/5 Monitoring Panel ON | - | - | - |
| system discharge | - | - | - |
| valve closed/open | - | - | - |
| Pressure Healthy | - | - | - |
| Battery Low indication by LED indicator Third Party Intigration facility to intigrate with other fire safety device like smoke detection system panel etc Yes * Electric Buzzer 50 dB piezo electric buzzer * Pressure switches to sense the drop in pressure Yes * Option to connect upto 4 systems in one panel true * If not connect 4 system in one panel please declare NA * Suitable valve for closing & releasing Yes * Straight connectors elbow connectors/T connectors for connecting HST in case wherever required Yes * End of line adapter Yes * End of line plug Yes * Conventional electric sounder suitable to operate between temperature -20⁰C to +60⁰C | - | - | - |
| with a sound of minimum 60 decibles with variable tones in Red Colour and IP-66 Rated With * PERFORMANCE Ozone Depleting Potential Zero * HST Tube type multi layer and UV protected * Max Working Pressure 20 Bar * Burst Pressure at 20 ⁰C 108 * Operating Temperature range shall be -20⁰ C to 60⁰ C -20⁰ C to 60⁰ C * System operating 15 bar * 3/5 pressure CERTIFICATION Complete system testing and certification LPCB Standard LPS 1666:Issue 1.0 LPCB Standard LPS 1666:Issue 1.0 Test report of the Heat sensing tube Yes * Marking of OEM Supplier Name & year of production on the tube Yes * Valve Certification TPED certificate for valve in conformity to EN ISO 10297:2006/Pi/CE Marked * For panel having ventilation or exhaust fan adequate safety factor for clean agent as per LPS 1666 to be provided Yes * System operation and maintenance manual to be submitted along with the supplies Yes * Design lifespan period (Min 5 years) 10 * Test Report No and Date - * Name and Address of the Lab - * Test Reports to be furnished to the buyer on demand Yes * Warranty of the complete system (years) 2 1 | - | - | - |
| 2 | - | - | - |
| 3 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Supriya Kumari 734421 | - | - | - |
| Air Force Station | - | - | - |
| Bagdogra 1 15 | - | - | - |
Exempted
9 Oct 2018
25 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_655432.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .