Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAdmitted-Finance | ₹25.7 L | L1 | Admitted-Finance |
| 2 | L2₹26.0 L+₹31,726 (1.24%)Admitted-Finance | ₹26.0 L+₹31,726 (1.24%) | L2 | Admitted-Finance |
| 3 | L3₹26.3 L+₹65,352.50 (2.55%)Admitted-Finance | ₹26.3 L+₹65,352.50 (2.55%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TOHEED ALAM L2 | M/S BANDAY ELECTICALS L1 | M/S SHAH ELECTRICAL CONSTRUCTION AND SUPPLIER L3 |
|---|---|---|---|---|---|---|
| 1.00Creation of 25 KVA at Chanpura W NO 1 Dhara B along with HT/LT Under DDC Grant.( All items are SITC) | ||||||
| 2.00 | 11/0.433kV, 3-phase 25 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, as per amendment 4 of IS 1180-2014 (Aluminium wound) | 1 | No | 81,000 ₹81,000 | 80,000 ₹80,000 Lowest | 90,000 ₹90,000 |
| 3.00 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 1 | Set | 5,000 ₹5,000 | 3,000 ₹3,000 Lowest | 6,500 ₹6,500 |
| 4.00 | 11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm | 1 | Set | 4,500 ₹4,500 Lowest | 6,000 ₹6,000 | 7,000 ₹7,000 |
| 5.00 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | 4,500 ₹4,500 | 3,000 ₹3,000 Lowest | 6,000 ₹6,000 |
| 6.00 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor | 20 | Mtr | 110 ₹2,200 Lowest | 250 ₹5,000 | 300 ₹6,000 |
| 7.00 | 8 Mtr. Long ST Pole (ST-410 SP15)(HT=2,LT=4,S/Station=3) | 9 | Nos | 13,500 ₹1,21,500 Lowest | 15,000 ₹1,35,000 | 13,500 ₹1,21,500 Lowest |
| 8.00 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | 12 | Nos | 350 ₹4,200 | 300 ₹3,600 | 250 ₹3,000 Lowest |
| 9.00 | GI Channel/Angle/Flat of sizes including clamps | 262 | Kgs | 155 ₹40,610 | 120 ₹31,440 Lowest | 125 ₹32,750 |
| 10.00 | Aluminium Thimble 95 Sq. mm | 12 | Nos | 30 ₹360 | 10 ₹120 Lowest | 30 ₹360 |
Tender Value
₹27.7 L
EMD Value
₹56,000
Closing Date
17 Aug 2026, 4:00 pmClosed
XEN ED Doda
ED Doda
5 creations DDC/CDF
2026_PDD_320201_1
ED Doda/JPDCL/45 of 2026-27
Open Tender
Electrical Works
Turn-key
ED DODA
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
XEN ED-Doda
₹56,000
5 Sept 2026
8 Aug 2026
18 Aug 2026
8 Aug 2026
17 Aug 2026
8 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Creation of 25 KVA at Chanpura W NO 1 Dhara B along with HT/LT Under DDC Grant.( All items are SITC) | - | - | - | - |
| 2 | 11/0.433kV, 3-phase 25 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, as per amendment 4 of IS 1180-2014 (Aluminium wound) | 1 | No | - | - |
| 3 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 1 | Set | - | - |
| 4 | 11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm | 1 | Set | - | - |
| 5 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | - | - |
| 6 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor | 20 | Mtr | - | - |
| 7 | 8 Mtr. Long ST Pole (ST-410 SP15)(HT=2,LT=4,S/Station=3) | 9 | Nos | - | - |
| 8 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | 12 | Nos | - | - |
| 9 | GI Channel/Angle/Flat of sizes including clamps | 262 | Kgs | - | - |
| 10 | Aluminium Thimble 95 Sq. mm | 12 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tendernotice_2.pdf
PDF • 0.71 MB
Tendernotice_3.pdf
PDF • 7.52 MB
BOQ_1063339.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .