Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹16.1 LAdmitted-Finance C 64 SECTOR 57 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201307 UDYAM UP 28 0069283 09AACCV7613B1ZI B M R MII STATUS AS NOT VERIFIED | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201307 | ₹16.1 L | Admitted-Finance |
| 2 | ₹17.0 LAdmitted-Finance 29 69 E LAKSHMI NAGAR EDAYAR PALAYAM PIRIVU KUNIYAMUTHUR POST COIMBATORE 641008 | COIMBATORE | COIMBATORE | TAMIL NADU | 641008 | ₹17.0 L | Admitted-Finance |
| 3 | ₹31.5 LAdmitted-Finance ROON MARG OLADAN TEHSIL MERTA CITY MERTA CITY NAGAUR RAJASTHAN 341511 UDYAM RJ 25 0005452 | NAGAUR | RAJASTHAN | 341511 | ₹31.5 L | Admitted-Finance |
| 4 | Rejected-Technical | - | Rejected-Technical Not Qualified as per QR |
| Sl No | Description | Qty | Unit | R.K.ENGINEERS | PREMIER ENGINEERING WORKS | VARALKA Engineers Private Limited |
|---|---|---|---|---|---|---|
| 1.00Air oil cooler assembly comprising of radiator (cooling system made from Aluminium) together with 3-Phase AC motor Fan finger guard Assembly | ||||||
| 1.01 | Fl.Grp2,PS bar 26, Ts C 120,V L 1.9, ( Initially installed T2 Cooler Assembly AKG part code 5202.203.0000IN) | 1 | Nos. | 44,225 ₹52,185.50 | 65,000 ₹76,700 | 38,000 ₹44,840 |
| 1.02 | Fl.Grp2,PS bar 26, Ts C 120,V L 2.9,PT bar 26, Motor Capacity 3Ph/50Hz/415V/ 1500 RPM/0.37 KW ( Initially installed T3-203 Cooler Assembly, AKG part code 5203.203.0000IN) | 1 | Nos. | 58,725 ₹69,295.50 | 65,000 ₹76,700 | 46,800 ₹55,224 |
| 1.03 | Fl.Grp2,PS bar 26, Ts C 120,V L 6.3,PT bar 30, Cooling Capacity 1720 K Cal/Hr, Motor Capacity 3Ph/50Hz/415V/1500 RPM/0.37 KW (Initially installed T5-203 Cooler Assembly AKG part code 5205.203.0000IN) | 1 | Nos. | 76,000 ₹89,680 | 80,000 ₹94,400 | 75,600 ₹89,208 |
| 1.04 | Fl.Grp2,PS bar 26, Ts C 120,V L 10.6,PT bar 30, Cooling Capacity 1720 K Cal/Hr, Motor Capacity 3Ph/50Hz/415V/1380RPM/0.55 KW ( Initially installed T7-203 Cooler Assembly AKG part code 5207.203.0000IN) | 1 | Nos. | 1,23,900 ₹1.5 L | 1,50,000 ₹1.8 L | 1,48,270 ₹1.7 L |
| 1.05 | Fl.Grp2,PS bar10, Ts C 120,V L 25,PT bar 15, Cooling Capacity 50000 K Cal/Hr, Motor Capacity 3Ph/50Hz/415V/ 1500RPM/5.5 KW ( Initially installed T10-203 Cooler Assembly AKG part code 5210.203.0000IN) | 2 | Nos. | 9,14,800 ₹10.8 L | 3,30,000 ₹3.9 L | 5,12,540 ₹6.0 L |
| 1.06 | Acoustic pressure level 82 LpA dB(A), weight 25 Kg, 220v/60 Hz( Initially installed:- Parker Hannifin make part Code:- LAC2-011-2-X-00-000-0-0 ) | 2 | Nos. | 1,17,450 ₹1.4 L | 1,30,000 ₹1.5 L | - |
| 2.00Air oil cooler (radiator only)(cooling system made from Aluminium) | ||||||
| 2.01 | Fl.Grp2,PS bar 26, Ts C 120,V L 1.9, ( Initially installed T2 Cooler Assembly AKG part code 5202.203.0000IN) | 1 | Nos. | 44,225 ₹52,185.50 | 50,000 ₹59,000 | 16,747 ₹19,761.46 |
| 2.02 | Fl.Grp2,PS bar 26, Ts C 120,V L 2.9,PT bar 26, Motor Capacity 3Ph/50Hz/415V/ 1500 RPM/0.37 KW ( Initially installed T3-203 Cooler Assembly, AKG part code 5203.203.0000IN) | 1 | Nos. | 58,725 ₹69,295.50 | 50,000 ₹59,000 | 24,072 ₹28,404.96 |
Updated dates
Tender Value
₹32.9 L
EMD Value
₹65,890
Closing Date
5 Jan 2026, 11:00 amClosed
CE, CSCTPP
O/o CE, CSCTPP
Supply Of Air Oil Coolers (Radiators) For Conveyors,Wagon Tipplers And Secondary Crushers At CHP, CSCTPP, Chhabra
2025_RRVUN_513847_1
TN-SC-633/2025-26(MM)
Open Tender
Mechanical Engineering Items
120 days
at plant site
As per QR
2 documents required · 2 mandatory
₹1,180
Yes
Accounts Officer, CSCTPP, Chhabra
₹65,890
Yes
1 Apr 2026
20 Nov 2025
6 Jan 2026
20 Nov 2025
5 Jan 2026
20 Nov 2025
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
1.35 MB
Tender Documents
Tender Documents • 1.84 MB
BOQ
BOQ • 0.35 MB
Download all tender documents and submit your bid