Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.5 LQualified Make: NA
Model: SafetyOne9LtrFoamSP 16 1ST FLOOR CHUNAWALA BUILDING NEAR AL SADIQ HOSPITAL MOHAMMAD ALI ROAD MANDVI MUMBAI MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | Make: NA
Model: SafetyOne9LtrFoamSP | ₹1.5 L | L1 | Qualified |
| 2 | Disqualified Make: SAFEPRO
Model: SPF-9MF 1 34 RUCHI KHAND 2 SHARDA NAGAR LUCKNOW UTTAR PRADESH 226002 UDYAM UP 50 0121474 | LUCKNOW | UTTAR PRADESH | 226002 | Make: SAFEPRO
Model: SPF-9MF | - | - | Disqualified |
| 3 | Disqualified Make: SAFEPRO
Model: SFSPL9MF 16 B KURLA INDUSTRIAL ESTATE NEAR SEVA SADAN ROAD NARAYAN NAGAR GHATKOPAR W MUMBAI MAHARASHTRA 400086 | MUMBAI SUBURBAN | MAHARASHTRA | 400086 | Make: SAFEPRO
Model: SFSPL9MF | - | - | Disqualified |
| 4 | Disqualified Make: LIFESECURE
Model: Lifesecure, LS-321 E 173 SECTOR 4 DSIIDC INDUSTRIAL AREA BAWANA DELHI 110039 NORTH WEST DELHI DELHI 110039 | NORTH DELHI | DELHI | 110039 | Make: LIFESECURE
Model: Lifesecure, LS-321 | - | - | Disqualified |
| 5 | Disqualified Make: FIRE ESCORT
Model: FFS-9 102A FIRST FLOOR TC JAINA TOWER A 1 BLOCK JANAK PURI NEW DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | Make: FIRE ESCORT
Model: FFS-9 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
3 Aug 2018, 1:00 pmClosed
Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 136 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Foam Based Foam Based Expellant Medium N2 Based (Stored Pressure) N2 Based (Stored Pressure) Constructional Foam Based Extinguishing Media Aqueous Film Forming Foam (AFFF) - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) 9 9 Powder Based Fire Extinguisher Capacity (Kg) NA 1
2
4
6
9
NA Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2
3
4.5
NA Water Based Fire NA 2
NA 1/3 Extinguisher Capacity Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 12.5 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire false - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire false - Performance Operating Temperature (° C) -20° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar
Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=1 for Class-B - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 16 Fire Rating for Class -A Fire Extinguisher 4A - Fire Rating for Class -B Fire Extinguisher 55B - Certification BIS Marking Yes - CM/L No.* with Validity - - 2/3 Period Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No - - Test Report Date - - Name of the Lab - - Address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P S PRADEEP 560014
Station Logistics Section
AFS Jalahalli East
Bangalore 136 30
399571
GEM/2018/B/56555
Portable Fire Extinguishers IS 15683
30 days
Karnataka
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 136 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Foam Based Foam Based Expellant Medium N2 Based (Stored Pressure) N2 Based (Stored Pressure) Constructional Foam Based Extinguishing Media Aqueous Film Forming Foam (AFFF) - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) 9 9 Powder Based Fire Extinguisher Capacity (Kg) NA 1 | - | - | - |
| 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA Water Based Fire NA 2 | - | - | - |
| NA 1/3 Extinguisher Capacity Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 12.5 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire false - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire false - Performance Operating Temperature (° C) -20° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar | - | - | - |
| Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=1 for Class-B - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 16 Fire Rating for Class -A Fire Extinguisher 4A - Fire Rating for Class -B Fire Extinguisher 55B - Certification BIS Marking Yes - CM/L No.* with Validity - - 2/3 Period Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No - - Test Report Date - - Name of the Lab - - Address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P S PRADEEP 560014 | - | - | - |
| Station Logistics Section | - | - | - |
| AFS Jalahalli East | - | - | - |
| Bangalore 136 30 | - | - | - |
Exempted
3 Aug 2018
30 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_399571.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .