Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC UNIT NO 117 IDEAL DEVAJI KESHAVAJI INDUSTRIAL ESTATE W T PATIL MARG CHEMBUR MUMBAI MAHARASHTRA 400071 | MUMBAI SUBURBAN | MAHARASHTRA | 400071 | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.6 L+₹18,942.51 (0.38%)Rejected-AOC 151 SHOP NO 1 ASHTAVINAYAK APARTMENT COOPERATIVE HOUSING SOCIETY MATRU MILAN VIKAS KENDRA MARG SECTOR 44 NERUL W THANE MAHARASHTRA 400706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-AOC L2 | |
| 3 | L3₹53.3 L+₹3.9 L (7.82%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹65.4 L+₹15.9 L (32.2%)Rejected-AOC NO 3 BALAKRISHNA BUILDING NG ACHARYA MARG CHEMBUR MUMBAI MUMBAI MAHARASHTRA 400071 | MUMBAI SUBURBAN | MAHARASHTRA | 400071 | L4 | Rejected-AOC L4 |
Tender Value
₹64.5 L
Closing Date
5 Jan 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer (GSS)
3rd Floor, V.S.Bhavan, Anushaktinagar, Mumbai-94
Annual contract for day to day maintenance of electrical distribution systems at Anushaktinagar, Old Mandala, TMC, TIFR and Payalipada colonies, Mumbai
2021_DCSEM_664009_1
DCSE/CQD/QSC/GSS/21-22/NIT-19 dt.16.12.2021
Open Tender
Electrical Works
Item Rate
365 days
Anushaktinagar, Old Mandala etc. Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
4 Apr 2022
21 Dec 2021
6 Jan 2022
21 Dec 2021
5 Jan 2022
21 Dec 2021
21 Dec 2021 - 30 Dec 2021
Amount
Assisting dept. technicians in attending day to day break-downs, opeartion and maitenance under the supervision of dept. shift in charge as per tender specifications and as instructed by E.I.C
Supply of spares for day to day maintenance
RCBOs
40 A FP, 30mA sensitivity,AC type
25 A, DP, 30mA sensitivity,AC type(compact 2module)
32 A, DP, 30mA sensitivity,AC type(compact 2module)
40A, DP, 30mA sensitivity,AC type
63A,FP, 300mA sensitivity,AC type
MCBs & enclosures
40A-63A FP, 10kA,MCB
40A-63A,SP,MCB
40A-63A,DP,MCB
Enclosure for DP MCBs
Enclosure for FP RCBOs
SFU & Isolators
FN (SK95651)/FNX 63
Fuse links
63A bolted type HRC fuse
32A,bolted type HRC fuse
6-32A HF type
63A HF type
80A,bolted type HRC fuse
Fuse bases
HK 32B of M/s L&T make
HK 63B of M/s L&T make
HK 32H of M/s L&T make
HK 63H of M/s L&T make
HK 125B of M/s L&T make
Indication lamps
48V,DC/110V,DC/230V,AC LED indication lamp(green/red/Yellow/amber)
48V,DC/110V,DC/230V,AC LED indication lamp(White/Blue)
Wires & cables
FRLS garde PVC insulated 6 sq.mm flexible copper wire
FRLS garde PVC insulated 10 sq.mm flexible copper wire
4CX 6 sq.mm cu flexible cable
6sq.mm/10sq.mm heavy duty copper tube terminals
16sq.mm/25sq.mm heavy duty copper tube terminals
35sq.mm/50sq.mm heavy duty copper tube terminals
70sq.mm/95sq.mm heavy duty copper tube terminals
6sq.mm/10sq.mm heavy duty copper reducer terminals
16sq.mm/25sq.mm heavy duty copper reducer terminals
35sq.mm/50sq.mm heavy duty copper reducer terminals
70sq.mm/95sq.mm heavy duty copper reducer terminals
Copper heavy duty in-line connectors
6sq.mm/10sq.mm
16sq.mm/25sq.mm
35sq.mm/50sq.mm
70sq.mm/95sq.mm
120sq.mm/150sq.mm
240sq.mm/300sq.mm
Direct operated (direct mounting on contactors) over load realy for L&T make Power air break contactors.
4 to 6.5 A/6 to 10 A MK type series
RTO-2(15-21A) 20HP
RTO-2(20-31A) 30HP
RTO-3(29-38A) 40HP
RTO-3(37-49A) 50HP
RTO-3(47-62A) 75HP
RTO-4(57-84A)CT OPERATED 100HP
RTO-4(72-108A) CT OPERATED 120HP
SPP relay with 2NO + 2NC(VSP-D2)
Power Contactor of M/s L & T make (Part-I)
Power Contactor of M/s L & T make (Part-II)
MO0 22E WITH 2NO+2NC 240VAC COIL
Spares of Power Contactor of M/s L & T make (Part-I)
MNX80 Spare contact Kit Without coil
MNX95 Spare contact Kit Without coil
MNX110 Spare contact Kit Without coil
MNX140 Spare contact Kit Without coil
Front mounting Add on block MN A1
Front mounting Add on block MNX A2
Side mounting aux add on block for MNX95-650
TOP ADD ON BLOCK 2NO FOR MO-9-110, MO-0 CONTACTOR
Spares of Power Contactor of M/s L & T make (Part-II)
TOP ADD ON BLOCK 2NO+2NC FOR MO-9-110, MO-0 CONTACTOR
TOP ADD ON BLOCK 1NO+1NC FOR MO 9-110, MO-0 CONTACTOR
ML2/ML3 coil
ML4/ML6 coil
MNX 80 coil
MNX110 coil
Spares of Power Contactor of M/s L & T make (Part-III)
Connectors
CSTSN5 with partition plate
CSTSN6 with pattition plate
CST RN5/RN6 with end plate
CTS 35L with partition plate
CTS 70L with partition plate
CBB 150 with partition plate
CBB 185 with partition plate
Connectors - CBTDU4/CMDT4
Insulation mats
Insulation mat class-A,2mm thick as per IS 15652
Insulation mat class-B,2.5mm thick as per IS 15652
Fabrication, supply, installation, Testing & commissioning of 14SWG M.S CRCA sheet hot dipped galvanised meter box of size approx. 550 x 400 x 220 mm complete with following & as instructed by Engineer incharge. 1) Space provision for three phase energy meter 10 - 60 Amp - 1 No. 2) Space provision for FP RCBO. 3) 4 nos of stud type connector suitable for connecting cables of sizes upto 35 sq.mm. simialr to CSTSRN6 of M/s connectwell make with terminal channel for fixing. 4) Interconnecting wires 6 sq.mm
Fabrication, supply, installation, Testing & commissioning of 14SWG M.S CRCA sheet hot dipped galvanised cover/ Gland plates of required size for meter box/MDB/Feeder pillars etc. With suitable sizes of cable gland holes, including fixing with suitable sizes of screws etc.& as instructed by Engineer incharge. Note:- Scope also includes disconnection & connection of various sizes of existing cables.
Supply, installtion of lead acid batteries 2V, 150AH plante battery similar to YKP-13 of M/s. Exide make
Complete cleaning of substations rooms,Electrical rooms,DG set rooms/yards inside and outside, outer surface of electrical panels/equipment, substation premises transformer yards as per attached list including cutting of vegetation around rooms as instructed,including sweeping of floors /walls/ceiling, mopping of floors, cutting of grass /tree branches near substation premises, transformer yard and also disposing the same,shifting of scrap materails at various places to central place using hand cart and as per instruction of EIC. Note: a)The contractor has to arrange all consumable materials such as heavy duty vacuum cleaner,brooms, bleaching powder, mopping sticks, choppers, buckest and cloths etc. for carrying out the work. b) Semi skilled labour shall be deputed for the work and the manpower shall have basic knowledge about electrical installation and safety. c) The report shall be submitted to shift-in-charge and also get the report certified by shift in charge
Cleaning of substations rooms,DG set rooms/yards inside and outside, outer surface of electrical panels/equipment, substation, DG room/yard premises, transformer yard etc. Approx. size of Substation, DG set room/Yard is ranging from 6M x 4M to 30M x 20 as per specifications
Cleaning of Electrical rooms inside and outside, outer surface of electrical panels/ equipment etc.approx. size of electrical room is ranging from 3M x 2M to 6M x 4M as per specification
Cleaning of Electrical rooms/meter rooms at Vajra Bldg. outer surface of electrical panels/ equipment etc.approx. size of electrical room is ranging from 2M x 3M to 2M x 6M as per specification
yashotha enterprises
SKYLINE ELECTRICALS
K Sharma Electricals Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .