| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹50.8 L+₹3.0 L (6.26%)Rejected-Finance | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹50.9 L+₹3.1 L (6.45%)Rejected-Finance | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹53.7 L+₹5.9 L (12.3%)Rejected-Finance | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L5₹54.0 L+₹6.2 L (12.9%)Rejected-Finance PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L5 | Rejected-Finance Being 5th Lowest |
| Sl No | Description | Qty | Unit | ENJOY L6 | BRITE INDUSTRIES L3 | somnath engineering corporation L4 | LAXMI ENTERPRISES L2 | DARSHAN CONSTRUCTION Co. L1 | K A ELECTRIC CO L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down defective /unserviceable Air Curtain (4 feet) of existing Make and capacity 1 to 1.5 m/sec air velocity at floor level, transporting to company authorized outlet , collecting company repaired Air curtain of same make and transporting back to site , re-fixing at original position complete including testing and commissioning the machine onto the mounting plate and ensure the safety than fix it tighten with screw complete all as specified and directed by Engr-in-Charge. | 4 | Each Job | 2,550 ₹10,200 Lowest | 5,000 ₹20,000 | 10,000 ₹40,000 | 3,000 ₹12,000 | 5,000 ₹20,000 | 3,400 ₹13,600 |
| 2.00 | Repair/Replacement of unserviceable blower motor, damaged blower, impellers unbalanced blower wheel of air curtain of capacity 1 to 1.5 m/sec air velocity at floor level and remove, clean or replace air intake screen & filters of air curtain, obstruction in discharge path (i.e door headers, automatic door openers etc), check electrical connection, replace the fuse and servicing and overhauling complete unit specified and directed by Engr-in-Charge. | 4 | Each Job | 3,500 ₹14,000 Lowest | 10,000 ₹40,000 | 12,000 ₹48,000 | 17,500 ₹70,000 | 14,000 ₹56,000 | 16,400 ₹65,600 |
| 3.00 | Supply and fix in replacement cooling tower Fan Assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for 61 to 120 TR capacity AC plants. | 2 | Each | 14,000 ₹28,000 | 5,500 ₹11,000 Lowest | 9,500 ₹19,000 | 20,000 ₹40,000 | 20,000 ₹40,000 | 22,000 ₹44,000 |
| 4.00 | Supply and fix in replacement cooling tower Fan Assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for upto 60 TR capacity AC plants. | 2 | Each | 6,900 ₹13,800 | 5,000 ₹10,000 Lowest | 9,500 ₹19,000 | 16,000 ₹32,000 | 15,000 ₹30,000 | 18,000 ₹36,000 |
| 5.00 | M&L for replacement of PVC fins suitable for any capacity and any make Cooling tower of AC plants of 2X1X0.6 feet having LPS fills with tie rod and turn buckle of suitable size to match the system complete all as specified and directed by Engr-in-Charge. | 450 | Each | 180 ₹81,000 | 350 ₹1,57,500 | 275 ₹1,23,750 | 150 ₹67,500 Lowest | 200 ₹90,000 | 180 ₹81,000 |
| 6.00 | Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities such as silt, dust particles mud/ sand inside the dome and around the fins, cleaning of base tray & grills, pot strainer, main shaft etc and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill & top cover including testing commissioning after reassembling complete including painting all as directed by Engr-in-Charge . | - | - | - | - | - | - | - | - |
| 6.01 | (a) cooling tower of capacity up to 35 TR | 8 | Each Job | 2,000 ₹16,000 | 3,500 ₹28,000 | 1,500 ₹12,000 Lowest | 1,500 ₹12,000 Lowest | 1,600 ₹12,800 | 1,650 ₹13,200 |
| 6.02 | (b) cooling tower of capacity 35 TR to 65 TR | 6 | Each Job | 2,100 ₹12,600 | 3,500 ₹21,000 | 1,850 ₹11,100 | 1,500 ₹9,000 Lowest | 1,700 ₹10,200 | 1,750 ₹10,500 |
| 6.03 | (c) cooling tower of capacity 66 TR to 250 TR | 8 | Each Job | 2,300 ₹18,400 | 5,000 ₹40,000 | 2,000 ₹16,000 | 1,500 ₹12,000 Lowest | 1,800 ₹14,400 | 1,800 ₹14,400 |
| 7.00 | Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of 61 TR and above Capacity AC plant. | 3 | Each | 12,500 ₹37,500 | 3,500 ₹10,500 Lowest | 9,500 ₹28,500 | 18,000 ₹54,000 | 15,000 ₹45,000 | 17,500 ₹52,500 |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
31 Jan 2026, 6:00 pmClosed
CWE Karanja
CWE Karanja Naval Station Karanja, Uran, Raigad - 400704
REPAIRREPLACEMENT AND IMPROVEMENT OF AC PLANTS COMPRESSOR SENSORS COOLING TOWER HOT COLD WATER PIPE LINE INSULATIONS AND REPLACEMENT OF DEFECTIVE ACCESSORIES OF CHILLER CONDENSER UNIT AHU HEATER AND OTHER ALLIED WORKS OF AC PLANTS OF NAD AREA AT
2026_MES_747997_1
84508-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Station Karanja
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) KARANJA
₹1.1 L
5 May 2026
10 Jan 2026
2 Feb 2026
10 Jan 2026
31 Jan 2026
24 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down defective /unserviceable Air Curtain (4 feet) of existing Make and capacity 1 to 1.5 m/sec air velocity at floor level, transporting to company authorized outlet , collecting company repaired Air curtain of same make and transporting back to site , re-fixing at original position complete including testing and commissioning the machine onto the mounting plate and ensure the safety than fix it tighten with screw complete all as specified and directed by Engr-in-Charge. | 4 | Each Job | 100 | ₹400 |
| 2 | Repair/Replacement of unserviceable blower motor, damaged blower, impellers unbalanced blower wheel of air curtain of capacity 1 to 1.5 m/sec air velocity at floor level and remove, clean or replace air intake screen & filters of air curtain, obstruction in discharge path (i.e door headers, automatic door openers etc), check electrical connection, replace the fuse and servicing and overhauling complete unit specified and directed by Engr-in-Charge. | 4 | Each Job | 100 | ₹400 |
| 3 | Supply and fix in replacement cooling tower Fan Assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for 61 to 120 TR capacity AC plants. | 2 | Each | 100 | ₹200 |
| 4 | Supply and fix in replacement cooling tower Fan Assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for upto 60 TR capacity AC plants. | 2 | Each | 100 | ₹200 |
| 5 | M&L for replacement of PVC fins suitable for any capacity and any make Cooling tower of AC plants of 2X1X0.6 feet having LPS fills with tie rod and turn buckle of suitable size to match the system complete all as specified and directed by Engr-in-Charge. | 450 | Each | 100 | ₹45,000 |
| 6 | Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities such as silt, dust particles mud/ sand inside the dome and around the fins, cleaning of base tray & grills, pot strainer, main shaft etc and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill & top cover including testing commissioning after reassembling complete including painting all as directed by Engr-in-Charge . | - | - | 100 | - |
| 6.01 | (a) cooling tower of capacity up to 35 TR | 8 | Each Job | 100 | ₹800 |
| 6.02 | (b) cooling tower of capacity 35 TR to 65 TR | 6 | Each Job | 100 | ₹600 |
| 6.03 | (c) cooling tower of capacity 66 TR to 250 TR | 8 | Each Job | 100 | ₹800 |
| 7 | Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of 61 TR and above Capacity AC plant. | 3 | Each | 100 | ₹300 |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
SOC.pdf
Additional Documents • 0.01 MB
Tenderdocuments.pdf
Tender Documents • 0.31 MB
BOQ_837659.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .