| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹14.8 LAccepted-Finance | l1 | Accepted-Finance l1 | |
| 2 | l2₹16.3 L+₹1.5 L (10.2%)Rejected-Finance | l2 | Rejected-Finance l2 |
Tender Value
Refer Docs
EMD Value
₹35,800
Closing Date
11 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ADITYA VANKA
GARRISON ENGINEER NAVY LAKSHADWEEP
MANNING AND OPERATION INCLUDING MAINTENANCE OF RO PLANT AT ICGS MINICOY UNDER GARRISON ENGINEER NAVY LAKSHADWEEP
2020_MES_404465_1
8271/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
GARRISON ENGINEER NAVY LAKSHADWEEP
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER NAVY LAKSHADWEEP
₹35,800
2 Mar 2021
17 Dec 2020
14 Jan 2021
18 Dec 2020
11 Jan 2021
30 Dec 2020
18 Dec 2020 - 24 Dec 2020
60 days
Amount
Manning and operation of 2 Nos of Water Reverse Osmosis (RO) plant of capacity 1500 LPH at ICGS, Minicoy using chemicals and spares mentioned below in subsequent para's, including monoblock pump sets installed in shallow wells and pump houses at ICGS RO plant Minicoy, including carrying out its day to day maintenance and deliver water supply upto raw water sump, from raw water sump to treated water sump and from treated water sump upto delivery point for two continous shifts, each shift of eight hours daily ( first shift from 05 AM to 01 PM and second shift from 01 PM to 09 PM) by employing 01 FGM (Skilled Labour) per shift complete all as specified and as directed by Engineer in charge. The work envisaged under this contract are as follows:- (a) Cleaning the unit of the plant and tanks regularly,backwashing and dosing of chemicals time to time. (b) Operation and maintenance of the plant by employing qualified operator as required and as directed by the Engineer in Charge. (c) Regular maintenance of pumps such as oiling ,greasing, motor shaft,pipes, minor rectification and replacement of minor parts such as nuts and bolts etc, pipes of small quantity,minor parts of pumps,electrical wiring etc as required and as directed by the Engineer in Charge.
SL ITEM NO 1 (Contd) (d) Cost of log book for recording plant operation, data/ servicing for each plant / machineries are deemed to be included in the unit rate quoted. Contractor shall provide required T&P and safety gadgets (as per IE rules) to all technicians employed by him in order to minimise breakdown and offers smooth functioning of RO plant in the station. (e) All consumables and spares required to ensure efficient maintenance and operation of the plant shall be measured and paid seperately under relevant items as supply only rates (f) The items of consumables and spares mentioned here- in- after for replacement will be as per the actual requirement at site.These items will be operated only if found necessary by the Engineer in Charge during the maintenance period.The contractor has no claim over the operation of full amount / spares under this items and payment will be made only for the spare parts actually replaced at site and as per the agreed rates.
Complete servicing and periodic maintenance (once in three months or as directed by Engineer in charge) of 2 Nos of RO plant of capacity 1500 LPH by replacing of filters and other components from OEM service engineer, acid washing, replacing of worn out parts such as washers,nuts,bolts,coupling,V belt etc, top up of engine oil,replacing of engine oil for high pressure pump from OEM service Engineers i.e. M/s Ozone Technologies, chennai complete all as specified and as directed by Engineer in charge. Note: The cost of spare parts shall be measured and paid seperately as supply only
Supply only Hydrochloric acid WTP RO 401 high grade complete all as specified and as directed by Engineer in charge.
Supply only 5 micron sediment filter (30" length,slim type HS-45-BB or equivalent as approved by Engineer in charge) complete all as specified and as directed by Engineer in charge.
Supply only RO membranes as per manufactures specification for 1500lph, Make-CSM, model RE 80.40 SHN SW range or equivalent in Nitto Hydranautic as approved by Engineer in charge complete all as specified and directed by Engineer in charge.
Supply only multiport valve top mount 40NB front facing suitable for existing carbon/sand filter having max pressure range 5Kg/sq cm consisting of three ports such as Filter, back wash and rinse complete all as specified and as directed by Engineer in charge.
Supply only pressure gauges panel mount 2.5 inch dial size back entry 1/4inches BSP thread glizerine filled suitable for (0 to 60Kg/sqcm and 0 to 1000 PSI) Make:- Initiative or as approved by Engineer in charge complete all as specified and as directed by engineer in charge.
Supply only Engine Oil 20 W 40 of make:- Castrol or servo as approved by Engineer in charge complete all as specified and as directed by engineer in charge.
Supply only O ring for victoric coupling 11/2 inches size complete all as specified and as directed by Engineer in charge.
Supply only V belt suitable for high pressure reciprocating pumping set, of make Ecodrive, model:-C257 C 99 or equivalent make as aprroved by engineer in charge complete all as specified and as directed by Engineer in charge.
Supply and fix in repair FRP membrane housing (FRP pressure vessel) operating pressure 1000 PSI complete all as specified and as directed by Engineer in Charge. Make:- Alfa, Aerosol model 8-28-1000 or equivalent make suitable for RO plant approved by Engineer in charge.
Supply only feed pump monoblock 3 phase, 415 V, suitable for 4.7 Cum/Hr discharge and 37 m head (1 to 1.5 HP) having SS/Brass impeller complete all as specified and as directed by Engineer in Charge. Make:- Grundfos/kirloskar/KDS as approved by Engineer in charge.
Mterial and labour for Complete Servicing of high pressure pump and motor from OEM service engineer of pump capacity 20HP, 60 Kg/Sqcm including replacement of worn out parts such as piston rings, crank shaft bush etc, serivicing also includes replacement of oil seal/ water seal, replacement of bushes, rusted SS nuts, bolts (of size 12mm X 35mm) etc complete all as specified and directed by engineer in charge. Make of pump:- Preevol (triplex plunjer), Model:- PHTN-400/5, Motor:- Kirloskar Electric Co ltd Tupe- CRS 46, 15 KW, 415 V complete all as specified and as directed.
Supply and fix in repair High pressure rubber hose 40 mm internal dia of length 2.5 m, maximum pressure range 100 PSI, both ends SS flanged type 2 AT-IM-24 HI IMPULSE DIN EN 853 2SN ID 1 Make:- Indomakffon or equivalent make as approved by Engineer in charge complete all as specified and as directed by Engineer in charge.
Supply and fix in repair High pressure rubber hose 15 mm internal dia type 2 ATIM8 HI IMPULSE DIN EN 853 25N , including end connector complete all as specified and as directed by Engineer in charge.
Supply and fix in repair fully automatic star delta starter suitable for 20 HP, 3 phase, 415 V motor type MU-G20 H of make L&T or equivalent make as approved by Engineer in charge complete all as specified and as directed by Engineer in charge.
Supply and fix in repair DOL starter suitable for 1.5 HP, 3 phase, 415 V motor type MU-G6 of make L&T or equivalent make as approved by Engineer in charge complete all as specified and as directed by Engineer in charge.
Supply only SS coupling suitable for SS pipe of 40 mm dia complete all as specified and as directed by Engineer in charge.
Replacing stainless steel cartridge filter housing alongwith SS flange for connecting inlet and outlet pipe complete all as specified and as directed by engineer in charge.
Suppply and fix in repair control panel for RO plant suitable with existing system consisting of start, stot, menu operating buttons and digital display and iediagram complete all as specified and as directed by Engineer in charge. Make:- Astro 33 panelor equivalent make as approved by engineer in charge.
Supply only anti scalant Liquid complete all as specified and as directed by Engineer in charge. Make:- Kuritti/Osmotech/Maxtrte as approved by Engineer in charge.
General Engineering and Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .