Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical Firm is not admitted as NO reflected in WLR QE Mar 2021 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
30 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 Works Engrs
HQ 133 Works Engrs PIN-914133 C/o 56 APO
SPECIAL REPAIR TO 11 KVA HT ELECTRIC FEEDER LINE TO DRUGMULA AND OTHER SANCTIONED ELECTRIC WORKS UNDER GE 874 EWS
2021_MES_409413_5
CWEK-59/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 874 EWS
Class C Category b ii
7 documents required · 7 mandatory
₹1,000
GE 874 EWS
₹1.5 L
Yes
HQ 133 Works Engrs
12 Nov 2021
25 May 2021
2 Jul 2021
25 May 2021
30 Jun 2021
16 Jun 2021
25 May 2021 - 8 Jun 2021
9 Jun 2021
60 days
Amount
Disconnecting electrical connection and taking down HT OCB, 11KVA, 3 phase 630 amp capacity and depositing at MES store complete, all as specified and as directed.
Supply,installation ,testing and commisssioning of HT 11 KV Vaccum Circuit Breaker (VCB) with panel, indoor type, of rating of 800 A, of rupturing capacity of 25KA with seperate trips relays and controls for (a) Over Current Tripping (adjustable threshold), (b) Earth Fault Tripping, (c) Under/ Over Voltage Faults (adjustable threshold) with tripping timing of less than VCBs already installed, with all necessary relays such as IDMT and master trip relays, hooter of 50 meter range, LED Beacon (hooter and beacon activation to be tripping incidents settings and deactivation being manual), counter for counting of trippings and counter for Electricity (input) shutdowns/ absence, with all data being stored and retrievable using USBs, all controls and operation of VCB being of numeric type, having set of housing for circuit breaker carriage mechanical interlock and automatic safety shutter gear including padlocking arrangements with Three Phase LCD / LED Voltmeters (02 Sets), Three Phase LCD/ LED Ammeters (02 Sets), Three Phase LCD Power Factor meter, Three Phase LCD/LED Wattage and kVA Meter, Three Phase LCD Multifunctional Electric Panel Meter (Secure Elite 445) with necessary CTs and PTs for all meters and any other devices, RYGB indicators (Two sets), with all meters duly caliberated for direct display of values (without any factors) with pushbutton adjustable setting centralised LCD control, with 06 Nos isolating plugs circuit breaker and all other fixing arrangements like PCC work in foundation, earthing and PCC cable duct all as specified and directed by engineer in charge, cable connection of above rating comprising of following:-
(a) Assembly of vaccum interrupter complete with epoxy support insulators and self aligining figer type isolating contacts. (b) Truck having internal racking in device for insertion and withdrawl of VCB complete with necessary interlocks. (c) Motor operated independent spring closed /spring tripping trip free oprsting mechanism closing and tripping push buttons and mechanical breaker closed/open spring chared/discharged indicators. (d) Operation counter (e) Shunt trip coils of 24 volt DC (capable of working in 20 to 26V DC and 180 - 270V AC also). (f) Breaker operated auxillary switch-04 Nos (N/O and N/C), Nos, bus bar chamber including a set of three all as specified. Note: (a) The job includes connecting with all existing cables using appropriate jointing kits and thimbles/ connectors. (b) The Circuit Breater and Panel to be of same Make, Make : ABB/ Crompton Greaves/ Schneider (c) The VCB should be wholely dependent on the below mentioned battery bank and charger and no external charger/ power supply may be required. The control systems should have an internal source to function for one week (without tripping) even when the battery bank is not operational as per required voltage. No memory shall be lost because of non supply. The VCB should be able to function with variation of +/- 5 Volts supply from rated supply, with a protection beyond this limit.
Supply and installation of battery bank of 24 Volts containing 02 Nos of Valve Regulated Lead Acid Type 12 Volt Batteries of 125 AH each for use in VCBs/ OCBs with minimum warranty of 48 months (replacement/ free repair warranty) from date of installation complete, all as specified and as directed. Make Exide, Luminous, AMCO or equivalent as approved by GE
Supply and installation of smart battery bank charger, that can provide DC output to VCBs from 220V supply when mains is present and through battery when mains is absent, with charger capable of providing DC output of 110 V or 12 V or 24 V or all three, with Zero time lapse, with AC input of 190V to 300 V (with internal stabiliser), of make power control systems or equivalent as approved by GE.
Supply only HT rubber matting 66kV grade, of thickness of minimum 3 mm, confirming to IS complete, all as specified and as directed.
Supply, Installation, Testing and Commissioning of AC 33kV Smart Trivector Electric meter, three phase, four wire TVM 110 Volt of minimum accuracy class 0.5, with Backlit LCD display, suitable for placement in incoming of 1.6 MVA transformer, measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW with special features like TOD, temper logging, optical communication port and RS 485 port (compatible with AMR, CMRI and LoRa nodes mentioned below), display in absence of power with transparent hinge type box, including foundation and shed, with below mentioned accessories required for fixing the electric meter, with IP68 rated cover, including necessary connections from CTPT to meter, along with any other additional accessories required, all specifications duly approved by GE. Model No WR300BB12RS of L&T or equibalent in Makes of Secure, HPL, Legrand, Havells Only
Supply, installation, testing and commissioning of 33 KV three phase four wire out door oil cooled type Current Transformer - Potential Transformer Combination of ratio 33 KV/rt3/110 V/rt3/110V/rt3, Class 0.5-3, Burden and other paramenters as specified by Engineer in charge as per site suitability. The CT-PT installed on existing two pole structure at site complete, all as specified and as directed.
Supply and Installation of IP68 rated electric meter cover, heavy duty, made of sheetmetal, corrosion proof, having hard break proof glass for meter reading, with rails for MCB mountings, for ibid electric meter, including all necessary fittings and material for installation of the cover and the meter into the cover complete, all as specified and as directed.
Supply and installation of Automatic Meter Reading System, with GSM Based Modem (GSM/GPRS enabled modem with 12V DC/220V AC power supply with quad band 850/900/1800/1900MHZ) for TVM along with power adaptor and power socket which allows RS485, RS232, Optical port, DLMS Devices to transmit data through GPRS/GSM network with post paid SIM card, consisting of data and SMS functions, atleast 1 GB data per day and 100 SMS per day, all costs paid for 5 yrs.complete, all as specified and as directed.
Supply and fixing Common Meter Reading Instrument (CMRI) and its all accessories including communication wire to record through optical communication port via magnetic locking/ interface with meter.
Supply and installation of Graphical Industrial fanless computing system, with 7th gen i3 (3.40GHZ) processor, 256 GB SSD disk, 8 GB RAM, 49" Graphical monitoring screen with input ports such as 03 x USB 4.0 Ports, Bluetooth, WIFI Ethernet port and output ports such as VGA, RS 485, RS 232 and HDMI ports complete, all as specified and as directed.
Supply, Installation, Testing and Commissioning of AC 11KV Trivector meter in Poly Carbonate Body, Accuracy Class 0.5s as per IS-14697 and ISI-5959 for communication, DLMS compliance with feature of Non Programmable CT at the site. Backlit LCD Display, (Measures kWH, kVAH, V, I, kW, 6 months history of Energy, Load Survey, TOD, Tamper detection & logging, power On/ Off Events, Having Galvancially Isolated Optical & RS232 Port (As per IS1-5959) suitable to measure instantaneous parameters of Rating-/1A with display in absence of power. Default PT ratio *: 11KV/110V & CTR : 1. Meter shall be supplied with Meter Box as per BOQ item 6.02, including necessary connections from CTPT to Meter, Along with any additional accessories required, all specifications duly approved by GE, complete all as specified and directed. Model No H0PB2N23131100OC00, in HPL and equivalent.
Supply, installation, testing and commissioning of 11 KV three phase four wire out door oil cooled type Current Transformer - Potential Transformer Combination of ratio 11 KV/rt3/110 V/rt3/110V/rt3, Class 0.5-3, Burden and other paramenters as specified by Engineer in charge as per site suitability. The CT-PT installed on existing two pole structure at site complete, all as specified and as directed.
Supply and Installation of IP68 rated electric meter cover, heavy duty, made of sheetmetal, corrossion proof, having hard break proof glass for meter reading, with rails for MCB mountings, for ibid electric meter, including all necessary fittings and material for installation of the cover and the meter into the cover complete, all as specified and as directed.
Supply and installation of Automatic Meter Reading System, with GSM Based Modem for TVM along with Power Adaptor and Power Socket which allows RS485, RS232, Optical port, DLMS Devices to transmit data through GPRS/GSM network with post paid sim card, consisting of Data and SMS functions, atleast 1 GB data per day and 100 SMS per day, all costs paid for 5 yrs.complete, all as specified and as directed.
Supply and fixing Common Meter Reading Instrument (CMRI) with suitable software of capacity 16.5 MB to record, reading through opto/ Optical communication port of any type of meter complete, all as specified and as directed.
Supply and erect Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint over a coat of primer including preparation of new surfaces all as specified. (Excavation and earth wok and PCC for foundation, channel, clamps nuts, bolts to be measured and paid separately ).
Material and laying for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to galvanized earth lead GI strip 25x4mm by means of bolts, nuts, check nuts and washer of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe medium grade 40 mm bore for protection of GI strip and connected to continuous earth lead on pole/test point supply and laying charcoal dust common salt PCC 1:2:4 type B-1, chamber and MS angle iron frame 40x40x 3mm and RCC cover 40 mm thick(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia PGI funnel and wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point incl testing complete all as specified and directed. Note:- The cost of earth lead/strip and GI pipe for protection of earth lead/strip upto 7.5 M is included in the quoted rate.
Material and laying for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to galvanized earth lead GI strip 32x6 mm by means of bolts, nuts, check nuts and washer of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe medium grade 40 mm bore for protection of GI strip and connected to continuous earth lead on pole/test point including charcoal dust, common salt, PCC 1:2:4 type B-1, chamber and MS angle iron frame 40x40x 3mm and RCC cover 40 mm thick(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia PGI funnel and wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point incl testing complete all as specified and directed. Note:- The cost of earth lead/strip and GI pipe for protection of earth lead/strip upto 7.5 M is included in the quoted rate.
Dismantling old unserviceable PCC/Tubular steel pole and taking out base plate, clamps, insulators, cross arms, stud, etc and removal from site, complete, all as specified and as directed.
Dismantling and taking down old unserviceable cross arms, clamps, bracing, etc. of any section from pole including nuts, bolts, washers, complete, all as specified and as directed. Note :- Cost of cutting of bolts (slag bolts) if reqd shall deemed to be included in the unit rate quoted for this item.
Dismantling, disconnecting and taking down old unserviceable insulators any type and size from poles/stays, etc. and removal from site, complete, all as specified or indicated and as directed.
Dismantling of ACSR Conductor from poles including zebra conductor from 66 KV sub station including cutting of binding from insulators of any type and capicity and removal from site, complete, all as specified and as directed.
Material and Labour for scrapping the old paint carefully from HT poles height upto 11 mtr including cross arms, bracing and clamps to prepare smooth surface and applying one coat of synthetic enameled paint and painting strips of red and black from foot of pole upto 1.5 mtr each strip of 30 cm height all as specified and directed.
Restretching of HT ACSR conductor and GI wire of any size and on any type of poles carrying upto six conductors in a 50 mtr span including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles all as specified.
Supply, laying, jointing, commissioning and testing cable 11000 volts grade of cross sectional size 95 sqmm, 3 core grade Aerial bunched cable with 3(three) power cores (stranded, compacted circular aluminium conductor screened with black extruded semi conducting compound, natural coloured XLPE insulated core screened with clack extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC (Core identification by colour tape marking red, yellow & blue with colour tape placed longitudinally under the copper tape) and one bare messenger wire shall be stranded non compacted circular aluminium alloy conductor. The cable should conform to IS : 8130-1984, IS:398 (Part-IV)-1994, IS:m 7098 (Part-II) 2011 & IS:5831-1984 complete all as specified and the cable shall be provided with end joints. There shall be no mid way joints in the cable.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays etc not exceeding 10 Square metre on plan and getting out in soft/loose soil, complete, all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide , exceeding 1.5 metre not exceeding 3.0 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays etc not exceeding 10 Square metre on plan and getting out in soft/loose soil, complete, all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete, all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete, all as specified and as directed.
Material and labour for plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete, all as specified and as directed.
Material and labour for plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete, all as specified and as directed.
Material and Labour for plain cement concrete 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregates) as in copings, bed plates and the like, finished the surface fair and even, including necessary form work, complete, all as specified and as directed.
Material and labour of lightning arrester metal di-oxide type, suitable for 11000 Volt with all fittings, trasmission class, discharge capacity 65 KA including connecting with HT line, complete, all as specified and as directed.
Material and labour for cross arm bracing supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide, complete, all as specified and as directed.
Supply & fixing stay assembly complete with all accessories such as stay plate 300mmx300mmx6mm, stay rod 16 mm dia and 215cm long threaded end with nut with nuts including 14mm dia GI stay bow. turn buckle, stay wire of size 7/3.15mm, etc. complete, all as shown in Electrical plate No 1 of SSR part I 2009 complete, all as specified and as directed. Note- The quoted rate shall include the cost of loop type insulator, stay clamps, excavation, PCC, stay wire, stay bow, turn buckle, nuts etc. complete.
Supply and fixing Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, complete, all as specified and as directed.
Supply and fixing pin type, porcelain, vitreous, white or brown or green insulators,11000 volts grade of 150 mm dia ,150 mm height including one galvanized mild steel spindle , two galvanised iron washers and one galvanized iron nuts, complete all as specified and as directed.
Supply and fixing for Disc type insulator, 45 kN 16 mm dia FRP insulation, with ball and socket type joints which is stackable, grey polymer 'Single disc assembly' for tension with tension clamps for conductors, working pressure 11000 volts, with all fittings, complete all as specified and directed.
Material and labour for Cable jointing kit suitable for HT 11 KV (Earthed) grade cable outdoor end termination, Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to120 sq mm, complete, all as specified and as directed.
Supply, fixing, commissioning and testing Switch Air Break gang operated outdoor type HT 11 KV triple pole , 400 Amps air break fitting type with fixed contacts of phosphorous bronze and moving contacts of copper with mechanically operated rod from ground level, Vertical/horizontal mounted complete with HT insulator on steel frame, operating rod made out of 25mm dia GI pipe medium grade with 12 insulators with testing point complete all as specified and directed.
Material and labour for Aluminium conductor steel reinforced (ACSR) Weasel/ zebra conductor including fixing, stretching on poles and proper noseling with binding wire to insulator of any size on over HT line service feeder as required at site, complete, all as specified and as directed.
Supply and installation of control and relay panel (indoor type) for HT 33 kV outdoor VCB/ SF6 breaker (Crompton Greaves Make) installed at site, as per degree of protection - IP 4X Cropton Type with Meters - digital three phase Ampere meter, digital three phase voltage meter, digital three phase Power Factor Meter, three phase watt meter, three phase kVA meter, digital multifunction energy meter (Secure Elite 445 series) and all necessary CTs and PTs for the meters LED Indicator - RYGB indicator lights - 02 Sets Hooter - of 50 meter range with a LED beacon Relays - IDMT relay (Crompton), Three element Auxillary relays (02 Nos), Master Trip Relay 8 Window Annunciator TNC Switch & Heater with thermostat & switch & illumination lamp with switch 3 pin plug & socket with switch & emergency push button with hooter & window annunciator & power pack
The control panel should trip the existing VCB upon - Under and Over Voltage (Adjustable threshold), Over Current (adjustable threshold) and earth faults and should clearly indicate the type of fault through a seperate RYGB indicator lamp. The control panel should have settings for adjusting the treshold values at which tripping occurs. The control panel should be capable of operating at 24V DC input (but also on 12V DC or 180 to 220 V AC input), including for all its components, with capability to function at +/- 5V variation in the DC input (2.5V when 12V given) also, beyond which necessary protection exists for over/ under voltage and currents. The panel should be completely numerical type (if not compatible with VCB, then the VCB control components alone can be or digital/ analog, as necessary, after prior approval of Engineer in Charge), including all its components. The panel should have inbult memory to store any data during DC power failures. The panel should store the number of faults occured, number of times of tripping, Log of input power (to VCB) absense (time of Off and Time of On), Log of power consumption and capable of transferring all these logs on to a computer. The wiring from control panel to the existing VCB (through weather proof cable) over wetherproof tray and minor repair alterations (including stores) to existing VCB is included in the price of this schedule itself. This also includes any other necessary components and equipment.
Supply and installation of HT 33 kV Current Transformers (set of three), Naturally Oil Cooled, Outdoor type, single phase (three nos for three phases), Dual Core - Dual Ratio (200/100/5/5A), 0.5S accuracy, with rain and snow protection complete, all as specified and as directed.
Supply and installation of HT 33 kV Potential Transformers (set of three), Naturally Oil Cooled, Outdoor type, single phase (three nos for three phases), Dual Core - Dual Ratio (200/100/5/5A), 0.5S accuracy, with rain and snow protection complete, all as specified and as directed.
Earthing complete with copper earth plate electrode of 60 cm × 60cm × 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.8 metres below normal ground level, connected by Copper strip of 20 mm x 3 mm as lead wire (from equipment to earthing pit) by means of bolts, nuts, check nuts and washers all of copper all as shown and directed at site by engr in charge, connected to earthing test point (construction as directed by engineer in charge) all as specified or indicated including testing on completion. No two earthing pits shall be at a distance of 2.25 meter or lesser. The copper strips shall not touch with walls and ground directly and shall move only on insulators and shall be completely covered in heat shrink tubes/ insulation tape. The rates for earthing includes the cost of adequate qantities if activated coconut and wooded charcoal mix and rock salt (including any necessary refilling as required, PCC earth pit, CI cover, earth recharge funnel and pipes, and all other necessary requirements and stores.
Earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop, earthing, etc., all with no part of conductor touching the ground but run through insulators (insulators included) and covered in heat shrink tubes/ insulation tapes, all as required, using 20 mm x 3 mm copper strip as lead wire complete, all as specified and as directed.
Install only of battery bank of 24 Volts (or any other cumulative capacity) with all necessary accessories included, such as copper bus bars, stands etc, (but without battries), using batteries as supplied below:
Supply and installation of Valve Regulated Lead Acid Type 2 Volt Batteries of 125 AH each for use in VCBs/ OCBs with minimum comprehensive warranty of 48 months (replacement/ free repair warranty) from date of installation complete, all as specified and as directed. Make Exide, Luminous, AMCO or equivalent as approved by GE
Supply and installation smart battery charger for charging batterypack, that can charge above battery packs (by charging individual batteries, simultaneously), provide DC output to VCBs, from 170 V to 220V AC supply when main supply is present and through battery when main supply is absent, with charger capable of providing output of 24V DC or 12V DC or 110V DC or all three, with output supply stabilised with no variation more than 0.5V for DC and not more than 5V for AC, with charger of make power control systems or equivalent as approved by EIC complete, all as specified and as directed.
Supply and installation of 20-30V DC to 110 V DC voltage converter, 1500W
Note:- Amount of credit of Rs. 57840.00 for retrieved materials is mentioned in Schedule of Credit Page No. 29 of tender documents in pdf form which will be deducted offline while acceptance of tender.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .