Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.6 LAccepted-Finance | L-1 | Accepted-Finance qualified | |
| 2 | L-2₹3.6 L+₹691 (0.19%)Accepted-Finance | L-2 | Accepted-Finance qualified | |
| 3 | L-3₹4.0 L+₹35,407 (9.72%)Accepted-Finance TEHSIL TRINTHA DISTRICT REASI 182311 JAMMU AND KASHMIR | REASI | JAMMU AND KASHMIR | 182311 | L-3 | Accepted-Finance qualified | |
| 4 | L-4₹4.2 L+₹58,167 (16.0%)Accepted-Finance | L-4 | Accepted-Finance qualified |
Tender Value
Refer Docs
EMD Value
₹8,800
Closing Date
3 Jul 2021, 4:00 pmClosed
EXECUTIVE ENGINEER
ELECTRIC DIVISION JPDCL UDHAMPUR
creation of 1 no 100KVA Sub Station along with HT/LT Network
2021_PDD_127011_1
ED/UDH/09 OF 2021-22 dated 11-6-2021
Open Tender
Electrical Works
Turn-key
30 days
udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹200
EXECUTIVE ENGINEER ELECTRIC DIVISION JPDCL
₹8,800
9 Jul 2021
12 Jun 2021
6 Jul 2021
12 Jun 2021
3 Jul 2021
12 Jun 2021
12 Jun 2021 - 23 Jun 2021
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 1 No 100 KVA substation at Devika Ghat along with HT/LT Network
11/0.433kV, 3-phase 100KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, Copper wound for 250kVA rating and with LV Cable Box having detachable Aluminium Gland plate
ACSR Weasel Conductor
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² , 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
11 mtr. Long ST Pole (ST-410 SP56)
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set, lightening arrestor and LT Distribution Box as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box with MCCB for incomer & SFU's for Outgoing Circuits ( For 100 KVA Substation)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3-Ø, 4-Wire Trivector Meter with CT
Cement bottoming 1:2:4 mix as per REC standards 0.45Cum/Pole
Painting of ST Poles 11 mtr of substation including cross arm, clamps with1 coat of Red Oxide (Asian/Nerolac Make )
Painting of ST Poles 11 mtr of substation including cross arm, clamps with1 coat of Red Oxide (Asian/Nerolac Make )
Painting of ST Poles 9 mtr of substation including cross arm, clamps with1 coat of Red Oxide (Asian/Nerolac Make )
Painting of ST Poles 9 mtr of substation including cross arm, clamps with 2 coats of Aluminium Paint (Asian/Nerolac Make )
R S CONSTRUCTION
M/S SURAJ PARTAP SINGH
M/s JAGDAMBA ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .