Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹11.0 L+₹2,264 (0.21%)Rejected-Finance A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance higher rate quoted | |
| 3 | L3₹11.1 L+₹11,250 (1.02%)Rejected-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L3 | Rejected-Finance higher rate quoted | |
| 4 | L4₹11.4 L+₹38,294 (3.48%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance highest rate quoted |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
15 Dec 2020, 3:00 pmClosed
EE II CKHED
P 12 CIT Road 1st floor KOLKATA 700014
Electrical Installation Work of treatment room in the Brach therapy OT Complex in the 2nd floor of the new Linac Building within the Compound of NRSMCH Kolkata SITC of Air Conditioning System
2020_WBPWD_306601_1
WBPWD/EE-II/CKHED/NIT-12/20-21
Open Tender
A/C ORG
Item Rate
45 days
NRSMCH
as per NIT
4 documents required · 4 mandatory
₹23,000
P 12 CIT Road 1st floor KOLKATA 700014
19 Mar 2021
26 Nov 2020
17 Dec 2020
26 Nov 2020
15 Dec 2020
4 Dec 2020
2 Dec 2020
Amount
Supply & Delivery of 8.5 TR Capacity Single Circuit Air cooled Ductable Split Unit with Rated Cooling Capacity of 102000 BTU/Hr, single scroll compressor, refrigerant R-410A, Room Discharge CFM 3400 , and suitable for operation on For ODU: 415 Volt, 50Hz, 3 PH & For IDU: 230 Volt, 50Hz, 1 PH AC supply. (Make: Hitachi / Ogeneral / Daikin)
Supply & Delivery of 3.0 TR Capacity Single Circuit Air cooled Ductable Split Unit with Rated Cooling Capacity of 36000 BTU/Hr, single rotary compressor, refrigerant R-410A/R 22, Room discharge CFM 1200 and suitable for operation on For ODU & IDU: 230 Volt, 50Hz, 1 PH AC supply. (Make: Hitachi / Ogeneral / Daikin)
Supply 3TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr. with 2 Nos. rotary compressor, refrigerant R-410A, 2 nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM. ( Make: Hitachi//Diakin/Ogeneral)
Supply 2TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 Nos. rotary compressor, refrigerant R-410A, 1 nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM. ( Make: Hitachi//Diakin/Ogeneral)
Installation & Commissioning Charges for 8.5 TR Ductable Split Air Conditioner (Both Indoor & Outdoor Unit) incl. nitrogen flashing , Leak testing & vaccuming, Gas Charging as per disrection E.I.C. .
Installation & Commissioning Charges for 3.0 TR Ductable Split Air Conditioner (Both Indoor & Outdoor Unit) incl. nitrogen flashing , Leak testing & vaccuming, Gas Charging as per direction E.I.C. .
Installation, testing and Commissioning Charges incl. refrigerant R-410A for 3.0/2.0 TR concealed type Split Air Conditioner
Supply, Installation & Commissioning of Copper Refrigeration pipe line for Liquid Line (5/8" OD with 0.6 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 8.5 TR Ductable Split Air Conditioner as per direction E.I.C.
Supply, Installation & Commissioning of Copper Refrigeration pipe line for Suction Line (1-1/8" OD with 0.6 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 8.5 TR Ductable Split Air Conditioner as per direction E.I.C.
Supply, Installation & Commissioning of Copper Refrigeration pipe line for Liquid Line (3/8" OD with 0.6 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 3.0 TR Ductable/3.0/2.0 TR Concealed Split Air Conditioner as per direction E.I.C.
Supply, Installation & Commissioning of Copper Refrigeration pipe line for Suction Line (3/4" OD with 0.6 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 3.0 TR Ductable Split Air Conditioner as per direction E.I.C.
Supply, Installation & Commissioning of Copper Refrigeration pipe line for Suction Line (5/8" OD with 0.7 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 3.0/2.0 TR Concealed Split Air Conditioner as per direction E.I.C.
Supply & Fabrication of sheet metal supply Ducting & Plenum Chamber complete with Support , Hanger etc. of the following as per Direction of E.I.C
Supply & Fixing of 19 mm thick Nitrile Rubber Foil Face Thermal Insulation on duct complete with all accessories as required as per Direction of E.I.C . (Make: Armacell/ K-Flex / A- Flex)
Supply & Fixing of 19 mm thick Nitrile Rubber Acoustic Insulation Under duct complete with all accessories as required as per Direction of E.I.C . (Make: Armacell/ K-Flex / A- Flex)
Supply & Fixing of retadrant nonporus double layer Flexible Connection ( CANVAS ) between each Indoor Unit & Duct and for concealed split AC as per Direction of E.I.C .
Supply & Fixing of 22 SWG GI Aerofoil blades type Non Return Damper complete with Linkages, Levers, Fitting, Support Accessories ,any other item required to make the system complete as per Direction of E.I.C
Supply, Fixing, Testing ,Commissioning of fresh air arrangement with Volume Control Damper , Birds Screen etc complete as required
Supply, Fixing, Testing ,Commissioning of Al Power Coated Supply Grill with VCD ,
Supply, Fixing, Testing ,Commissioning of Al Power Coated Supply Grill without VCD
Supply and fixing of Al powder coated continuous Grill (Make- Premier) for 3.0/2.0 TR concealed type Split Air Conditioner
Supply, Installation & Commissioning of 25 mm PVC Drain Pipe Line (25 mm OD, HD 1 mm Thick) with Insulation , Support & Bracket, For 8.5 & 3.0 TR Ductable Split Unit as per Direction of E.I.C
4 CORE X 2.5 Sq mm Armoured Cable for ODU to IDU of 8.5 Tr Ductable Split Unit as per Direction of E.I.C. (Make: Gloster / Havells/ Ploycab/ Finolex)
3 CORE X 2.5 Sq mm Armoured Cable for ODU to IDU of 3.0 Tr Ductable Split Unit as per Direction of E.I.C. (Make: Gloster / Havells/ Ploycab/ Finolex)
Supply & Fabrication of Trap Door & making arrangement for Servicing the Units, for both 8.5/3.0 TR ducable and 3.0/2.0 TR concealed split AC as per Direction of E.I.C
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 2 nos. 8.5/3 TR ductable split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 6Mtr. x 1.2Mtr., as per Direction of E.I.C
Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mm x 6mm) for making platform for installation of outdoor unit of 3.0/2.0 TR Concealed split AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be fabaricated & safe for ODU maintenance. Area of the platform is 3Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC Structural design should be approved by E.I.C.
Charges of Civil Works like Wall cutting , finishing as per Direction of E.I.C
Schaffolding for fixing of Outdoor Unit to a suitable height to avoid theft for both 8.5/3.0 TR ducable and 3.0/2.0 TR concealed split AC as per Direction of E.I.C
Suply , Fiting & Fixing in position suspended boxing for return/Suply air arrangement for ducting with frame work of alluminium hollow section of size 50mm X 25 mm (2.0 mm thickness) combined with aluminium corners of size 38 mm X 25 mm X , Suspended by alluminium hollow tube section of size 38 mm X 25 mm, 25mm X 25mm powder coated wall angle with alluminium composite panel of thickness 3.0 mm comprising of protective film , polyester coating primer, alluminium coil , sdhesive film , polyethelene core again with one layer adhesive film , alluminium bottom coating and finally service coating as per manufacturer's specification finished with alluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of E.I.C
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
MAXCOOL REFRIGERATION CO.
NATIONAL AIRCON
Lyric International
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .