Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | ₹37.0 L Quoted ₹37.6 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹46.7 L+₹9.1 L (24.3%)Rejected-Finance MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹46.7 L+₹9.1 L (24.3%) | L2 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹49.7 L
EMD Value
₹99,400
Closing Date
15 Nov 2021, 6:00 pmClosed
SHRI BIJENDRA SHARMA IDSE EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8403/21/E8
2021_MES_481507_2
8403/21/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class D Category a ii and b i
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹99,400
Yes
22 Nov 2021
27 Oct 2021
17 Nov 2021
27 Oct 2021
15 Nov 2021
2 Nov 2021
28 Oct 2021 - 1 Nov 2021
Amount
Excavation in trenches not exceeding 1.5 Mtr wide and n.exc 1.5 Mtr in depth in hard/dense soil getting out and levelling of bottom surface to required level for removing of old pipes or laying of pipeline all as specified.
Excavation in trenches not exceeding 1.5 Mtr wide and n.exc 1.5 Mtr in depth in soft/ disintegrated rock getting out and levelling of bottom surface to required level for removing of old pipes/ laying of pipeline all as specified.
Excavation in trencehs in road cutting/ hard rock and not exceeding 1.5 Mtr wide and n.exc 1.5 Mtr in depth for taking out old pipe/laying of new pipe including making good the disturbed surface of road with same finish to match the original finish all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil all as specified.
Removing excavated material of any type of soil/soft rock from site to a distance not exceeding 50 Mtr away and depositing where directed not exceeding 1.5 Mtr above the starting point all as directed.
Taking down/out GI/MS/CPVC tubing and connection of the following size and removing or setting aside serviceable pipes for refixing including disconnection of fittings etc all as specified of the following sizes
(a) 80 mm bore
(b) 50 mm bore
(c) 40 mm bore
(d) 25 mm bore
(e) 20 mm bore
(f) 15 mm bore
Relaying in trenches/refixing on wall/ceiling after repairing/ cleaning throughly by using steel rod/splitted bamboos complete GI/MS/CPVC tubings of any grade in old or new positions obtained from item No. 6(a) to 6(f) above including all fittings complete of the following sizes
(a) 80 mm bore
(b) 50 mm bore
(c) 40 mm bore
(d) 25 mm bore
(e) 20 mm bore
Supply & laying GI Tube medium grade with all fitting laid in trenches complete of the following size
(a) 80 mm bore size
(b) 50 mm bore size
(c) 40 mm bore size
(d) 25 mm bore size
(e) 20 mm bore size
(f) 15 mm bore size
All as per item No. 8.00 but fixed to wall/Ceiling or laid on floor of the following sizes :-
(a) 50 mm bore size
(b) 40 mm bore size
(c) 25 mm bore size
(d) 20 mm bore size
(e) 15 mm bore size
Supplying and laying in trenches CPVC Tubings SDR 13.5 pipes & plain CPVC SDR 11 fittings with all fitting and fixtures laid in trenches complete all as specified and directed of the following sizes :-
(a) 40 mm bore
(b) 25 mm bore
Supplying and fixing in wall/ ceiling CPVC Tubings SDR 13.5 pipes & plain CPVC SDR 11 fittings with all fitting and fixtures fixed on wall/ceiling or laid in floor complete all as specified and directed of the following sizes :-
(a) 40 mm bore`
(b) 25 mm bore
(c) 20 mm bore
(d) 15 mm bore
Supplying and fixing PVC Tubings with all fitting and fixtures fixed on wall/floor/trench complete all as specified and directed of the following sizes
(a) 20 mm bore
(b) 25 mm bore
(c) 75-80 mm bore
Supplying and fixing CPVC Ball valve with all fitting and fixtures complete all as specified and directed of the following sizes
(a) 20 mm bore
(b) 25 mm bore
S & F in repairs pressure gauge for water pipe line including all necessary items required and dismantling the old one complete all as specified and as directed
Taking up old cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead, complete all as specified and as directed by Engineer-in-charge, of the following sizes :-
Re-laying in trenches cast iron pipe with socket and spigot ends complete with all fittings after cleaning throughly and removal of all blockages by using splitted bamboos/steel rod effectively (pipe taken out/obtained from item No. 15.00 here as above) complete all as following size as specified and directed by Engineer-in-Charge. (Note- Rubber gasket joints/run lead joints and CI speicals/fittings shall be measured and paid separately)
M & L Cast Iron pipes with spigot and socket ends centrifugally class 'B' in any length, laid in trenches complete for the following sizes :- Note :- Excavation & earth work Run lead joint not included in the unit rate meterial same will be priced and measured & paid seperately under relevent item of the Sec 'A'
(a) 200 mm bore size
(b) 150 mm bore size
(c) 100 mm bore size
(d) 80 mm bore size
Cutting old cast iron pipes only and reducing to required length, before laying in position, for insertion of new tees, branches, etc for repair works, complete all as specified and directed by the Engineer-in-Charge, suitable for the following bore of pipes :-
(d) 200 mm bore
Material and Labour for lead wool joints suitable for CI spigot & socket pipes and fittings and caulking the joints properly for avoiding leakage etc suitable for the following bore of pipe, complete all as specified and directed by the Engineer-in-Charge, for the following sizes :-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
Material and labour for Rubber Gasket Joint including jointing materials, for spigot and socket cast iron pipes and fittings, complete all as specified and directed by the Engineer-in-Charge, for the following sizes :-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
Cutting existing Galvanized iron steel tubing for alterations or additions (each cut measured), complete all as specified and directed by the Engineer-in-Charge, suitable for the following bore of pipes :-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 or 50 mm bore
Supply and fix in repairs Gun-metal gate valves (i.e. taking out old unserviceable gate valves, opening carefully screwed both ends from iron pipes and removal from site) with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS:778, complete all as specified and directed by the Engineer-in-Charge, of following sizes :-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
Supply and fixing, jointing and testing of cast iron sluice valve ISI mark (PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel/brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as speicfied. for the following sizes :-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
M&L for fixing in repairs CI specials such as Cast Iron bends (any type, radius and angle), tapers (any type i.e straight, bend, increasing or decresing or double socket etc) Tee pieces single branch, 'Y' junction, double branch, cross, collar, caps, connecting pieces up to 200 mm dia .
Opening stuffing box of sluice valve and S&F in repair of U/S parts i.e. Stainless steel spindle , check nut fabricated out of superior quality all as per sample as required at site including replacement of unserviceable bolts, nuts & washers suitable for following size of sluice valves:-
(a) Bore of pipe 200mm
(b) Bore of pipe 150 mm
(c) Bore of 100 mm pipe
(d) Bore of 80 mm pipe
Supply & fixing in repairs PVC low pressure float valve assessories complete with epoxy coated aluminium rod and H.D ball of following sizes make prayag:-
(a) 20 mm bore size
(b) 25 mm bore size
Supply and fix in repairs brass foot valve screwed/flaged type suitable for GI/CI pipe complete all as specified and directed for the following sizes:-
(a) 40 mm size
(b) 65 mm size
Supply and fix in repairs CI foot valve screwed/flaged type suitable for GI/CI pipe complete all as specified and directed for the following sizes:-
(b) 80 mm size
(c) 100 mm size
Supply and fix in repais water level indicator mechanical type complete with all accessories such as float, wire, bracket and pulley, counter weight, indicator pin, float guide pipe etc and steel plate flat type duly painted with white paint and marking at every 10 cm interval with necessary letters and numbers of suitable size with signal red radium paint for indication of water level position and erected at the height from ground level to top edge for semi under ground sump and full length for overhead reservoir above the staging with necessary MS angle iron and flat iron support with nuts, bolts and washers including removing the old unserviceable items complete all as specified and directed.
Cleaning the vegetation including grass, bushes, small trees and all vegetation growth complete including digging out the root of bushes and small trees around the E/M installation/sump/OH reservoir, valve chamber, including chamber etc filling the rough holes with earth and levelling the surfaces by removing all debris to a distance n.exc 50m complete all as specified and directed.
S & F Flexible hose pipe heavy duty 40-80 mm mm dia for fitting in water filling point tightly complete all as specified and as directed
Supply and fix CI Swing type Non return Valve as per IS 5312 (Part 1&2) PN 1.6 CI Body Door/Bronze of following sizes.
(a) 80 mm bore sie
Supply and fix Brass Swing type Non return Valve including union, nipple of following sizes.
(a ) 50 mm bore size
(b ) 40 mm bore size
S& F in repairs rolled Mild steel plates of FE 410 -10 (Gde-E 250) (Plain) thickness not less than 5mm (UG Sump chamber cover) A grade as required size including cover welded aroud with MS flat iron of required size with locking arrangements including painting with two coats of synthetic enamel paint over a coat red oxide primer.
M&L for bacteriological and chemical analysis of water sample of borewell water at DIRECTOR OF HEALTH SERVICES, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA NOTE :- (a) The water sample should be carried in sterilised bottle/ watercan which will be issued by DIRECTOR OF HEALTH SERVICES, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA (b) The rate quoted shall be deemed to include transportation cost & cost of sterilised bottle
M &L brick/ stone work with burnt bricks / stone best quality locally available old size laid staright or curved on plan to any radius built in cement mortar 1:4 for E/M installation / vavle chamber complete all as directed including dismantling old disturbed surfaces
M &L rendering in 10mm thick on fair faces of brick/ stone work in cement mortar 1:4 and finish the surface fair and even complete all as directed.
Material and Labour for PCC 1:4:8 type D2 for filling and mass concrete using 40 mm graded stone aggregate for foundation and surface work.
Cleaning of 10000 Ltrs syntax water storage tanks by Draining out water from inside manually / pumping, removing all dirt, dust and mud, scraping down the wall / floor surfaces of syntax water tanks with wire brushes (inside surfaces) to remove impurities and cleaning inside surfaces with bleaching powder and fresh water, complete all as directed including writing capacity and date of cleaning (Cleaned on___2021) with white and black enamelled paint etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old painted surface by removing oil dirt, rust and scraping etc and applying one coat of synthetic enamel paint manually with Black/blue colour painting of Main Header of 400 mm dia and 06 mtr long including end plates and its sluice Valves installed at Hansa Vihar, 33KV Pump House and SH Simulator near OH tanks complete all as directed.
Supply and fixing aviation obstruction light on top of Overhead Tanks/Building yellow painted die-cast aluminium alloy husing Integral LED aviation light including giving electric connection and testing complete all as specified and directed. Make :- Bajaj or equivalent
Material & Labour in repair Cast iron detachable joint (CID) suitable for the following sizes of CI pipes:-
(a) 200 mm dia bore CI pipe
(b) 150 mm dia bore CI pipe
(c) 100 mm dia bore CI pipe
(d) 80 mm dia bore CI pipe
Supply and fix in repair Galvanised steel tubes heavy grade 40 mm (required for column pipe in submersible pump) including required accessories etc. complete as specified and directed.
Supply and fix in repair Galvanised steel tubes heavy grade 50 mm (required for column pipe in submersible pump) including required accessories etc. complete as specified and directed.
Supply only calcium based, high strength chlorination chemical for water disinfectant in granular form in factory sealed HDPE container (40 to 50 Kg each), chlorine concentration level 65-70% and delivered at store yard of AGE E/M-I of GE (NW) Vasco. Note:- (a) Stability: Projected shelf life of chlorination chemical must be one year with minimum loss of chlorine. (b) Operational Considerations: Must be safe to use in terms of level of insoluble components. There must be no risks relating to encrustations in equipment and pipe lines, no sludge generation, no hard water scaling in supply water. (c) Operator health consideration: Chlorination chemical must contain acceptable levels of granular size to avoid risks to operators from health safety point of view.
(d) The brand and make of the chlorination chemical must be stated and certified by all India Institute of Hygienic & Public Health not earlier than 2008, confirming compliance to all the above specifications with a declaration from the laboratory that from the technical strength, stability, health safety and operational point of view as well as the fact that this product is used for drinking water applications for consumption by humans. The brand and make of calcium based granular chlorination chemical must be suitable for drinking water chlorination and is recommended for use.
Cleaning of underground water storage sump of capacity 50,000 gallons capacity having one compartment by following process as under :- (a) Dewatering the tank/sump with including all dirt dust and mud. (b) Desilting and removal of dirty water and sludge with wire brush inside wall and floor surfaces to remove impurities. (c) Cleaning of walls, ceiling and bottom of tank by high pressure water jet and bleaching powder. (d) Removing mud/impured material to a distance 10m away from sump. (e) writing capacity and date of cleaning (Cleaned on___ 2021) with white and black enameled paint.
All as per serial item No.46.00 here-in-before but capacity 15,000 to 20,000 gallons
All as per serial item No. 46.00 here-in-before but capacity 10,000 gallons
All as per serial item No. 46.00 here-in-before but capacity 5,000 gallons
All as per serial item No. 46.00 above but over head water tank of upto 18 mtr of staging (Height of OH Tank) of capacity 40,000 to 50,000 gallons
S&F in repairs framed work such as ladders, walkways, railings, framework of water tanks and similar work confirming to FE-290, Grade E-165 including fixing on OH tank with necessary cement and welding work for providing on OH tank complete all as specified.
Disconnecting all electric / water supply connection from the mono block / centrtifugal pump set of any make/model electric driven AC Single / 3 phase, 220 /415 Volts of any make / model from any installation, transporting to workshop dismantling, removing the burnt out windings, cleaning the stator slots and rewinding with super enamelled copper wire of suitable gauge, insulating, proper heat varnishing, returned from work shop and re-installation at same position including commissioning and testing complete all as specified for the following capacity pumps.
(a) For Motor capacity 1 to 2 HP
(b) For Motor capacity 3 to 7.5 HP
(c) For Motor capacity 10 to 15 HP
(d) For Motor capaciy 30 to 40 HP
Repair overhauling of mono block pump set up to 2 to 5 HP by replacing worn out gland packing , gasket, bearing bushes, Scraping out of pump casing, bolts , nuts , washers etc, cleaning greasing tightening of bolts , nuts incl painting with one coat of synthetic enamelled paint to pump only, Re-installation incl alignment with motor, testing and all as specified and directed by Engineer in Charge.
All as per item No 53.00 here in before but of capacity above 5 HP and upto 15 HP
All as per item No 53.00 here in before but of capacity 30 HP to 40 HP
Taking down carefully the existing Unserviceable submersible pump set of any capacity / type along with Column pipe and Elect cable from the bore well by disconnecting all in-coming and out going water and elect connections of approx depth 150 mtr, pouring of concentrate Hydro chloric acid of 35 ltrs into the bore well bottom by using pipe upto to 150 mtr depth (i.e upto bottom), keeping the bore hole for 24 hrs for idle, flushng out the bore hole by using high pressure compresser air / back washing for a period of 2 hours or upto the time all sludge is flushed out till clear water is obtained, conducting yield test with "V" notch method and Re - installation of submersible pumps sets along with column pipe with fittings and Elect cables etc in the bore well all as directed by Engineer in Charge.
Note :- 1. The quoted rates shall be deemed to include the cost of any machinery / materials / man powers required for the complete flushing out of bore well 2. New items will be measured and paid separately under relevant item of this schedule. 3. Rewinding of submersible pump will be measured and paid separately.
M & L for servicing of submersible pumps of capacity 5 to 7.5 HP of any make including replacing of bushes, etc of brass impeller glands, worn out gaskets etc complete including testing all as directed.
M & L for rewinding of submersible motor of any make / model of Capacity 5 HP to 15HP with super enamelled copper wire of class F of standard specification with standard insulation material complete all as directed.
S & F Fully automatic star delta starter in sheet steel enclosure for 15 HP motor of relay range 9 - 15 Amp, complete all as specified and as per the directions of Engineer-in-Charge. Make:- L & T or equivalent
S & F Submersible pump starter in sheet enclosure with protection from single phasing / overload conditions / phase reversal / phase unbalance, 6-10 HP,relay range13-21 Amp,DOL starter complete all as specified and as per the directions of Engineer-in-Charge. Make:- L & T or equivalent
S & F Single Phase DOL starter in SS enclosure of 1.5 HP of relay range: 10.5 to 17.5 Amps complete all as specified and as per the directions of Engineer-in-Charge. Make :- L & T or equivalent
S & F three Phase DOL starter in SS enclosure suitable for 7.5 HP motor of relay range: 13 to 22 Amps complete all as specified and as per the directions of Engineer-in-charge. Make :- L & T or equivalent
Supply and fix in repair flat 6 sqmm, 3 core PVC insulated and PVC Flat sheathed industrial cable for submersible pump motor, 1100 volts confiming to IS: 694
Supply and fix in repair flat 4 sqmm, 3 core PVC insulated and PVC Flat sheathed industrial cable for submersible pump motor, 1100 volts confiming to IS: 694
Taking out the existing 3 HP capacity KSB make KRTU-65 Model Non clogging type submersible sewage pumpset from the sewage sump by disconnecting all incoming and outgoing sewage / elect connections carefully transport to workshop, transporting to workshop dismantling, removing the burnt out windings, cleaning the starter slots and rewinding with super enamelled copper wire of suitable gauge, insulating, proper heat varnishing, replacement of oil seal for motor and two bi-directional mechanical seal for pump, cleaning of strainer and impeller assy, replacement of bearings and taken back from work shop and re-installation at same position including commissioning and testing complete all as specified for the following capacity pumps.
Note :- 1. New impeller & strainer will be measured and paid separately 2. The item rate includes the draining/emptying of sewage sump if required for taking out sewage pump.
S & F in repairs SS strainer suitable for 3 HP capacity KSB make Non clogging type submersible sewage pumpset all as directed.
S & F in CI impeller suitable for 3 HP capacity KSB make Non clogging type submersible sewage pumpset all as directed.
S & F in repairs Heavy duty pvc cable 4 sqmm four core copper for 1100 v for sewage pump all as specified and directed by Engineer-in-Charge
Painting with one coat of synthetic enamel paint as per the existing colour by preparation of old surfaces for ACF, MGF along with 80 mm dia MS pipe line, valves, other connected accessories, etc. (i.e. From inlet to outlet pipe) complete in the sewage treatment plant at Hansa Vihar area incl writting of description on the plants all as directed.
Painting with one coat of synthetic enamel paint as per the existing colour by preparation of old surfaces for sewage treatment sump MS grill of approx size 5 Mtr x 5 Mtr made up of MS angle iron / square pipe complete at Hansa Vihar area all as directed.
Construction of valve pit brick masonary, internal size 600x600x600 mm (from top of PCC to bottom of cover) including excavation in any type of soil returning, filling around foundation are removal of surplus soil to a distance not exceeding 50 mtr PCC 1:4:8 type D2 in foundation brick work in cement mortar 1:6 ,10 mm thick plaster in cement mortar 1:4 to internal surface covered pit with MS sheet cover 3 mm thick with locking arrangement handle fixing arrangement and painting with oil paint two coat over a coat of red oxide primer all as specified and directed.
Construction of valve pit brick masonry, internal size 900x900x900 mm (from top of PCC to bottom of cover) including excavation in any type of soil returning, filling arround foundation are removal of surplus soil to a distance not exceeding 50 mtr PCC 1:4:8 type D2 in foundation brick work in cement mortar 1:6, 10 mm thick plaster in cement mortar 1:4 to internal surface covered pit with MS sheet cover 3 mm thick with locking arrangement handle fixing arrangement and painting with oil paint two coat over a coat of red oxide primer all as specified and directed
M & L for painting of valve chamber of size 60x60x60cm (internal dimension) with two coats of antifungal paint inside and outside of chamber and chamber cover with two coats of synthetic enamel paint over one coat of red oxide primer and removing small bushes and grass inside & outside of valve chamber all as specified and directed
All as per item No 73.00 but of size 90x90x75 cm (internal dimension)
All as per item No 73.00 but of size 120x120x90 cm (internal dimension)
S & F in repairs wire netting of stainless steel wire 1.4 mm dia fixed with tinned tacks of stainless steel wire staples for covering UG sump air vent as specified and directed
M&L for painting of existing Steel/RCC surface with two coat of Black/Blue colour synthetic enamelled paint over one coat of red oxide primer including preparation of surfaces over 10 cm width or girth .
M&L for writing letter or figures (Block, Roman, Italic of Indian) not exc 30cm high,
S&F Rotational moulded polyethylene water storage tanks capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in pisition all as specified in SSR Part I
S & F in repairs motor starter suitable for Non clogging type sewage pump set of 3 HP capacity in sheet steel enclosure outdoor type, weather proof, padestal mounetd with necessary PCC foundation, front openable, double door type with locking arrangements consisting the following all as directed. (a) Sinle phasing preventor with phase reversal protection - 01 No (b) Overload repaly 3-12 Amps with indicator - 01 No (c) Relay for high temp and low level with indicator lamp- Each - 01 No (d) Ammeter 0-20 A analog type - 01 No (e) Volt meter 0-500 Volts analog type - 01 No (f) Toggle switch for auto and mannual operation - Each - 01 No (g) LED Indiacting lamp (R,Y,B) - 01 Nos (h) DOL starter
(j) Suitable terminal blocks for incoming and uotgoing elect connections (k) MCB TP 32 Amps - 01 Nos as incoming (l) HRC Fuse base, grip with fuse of 32 A capacity - 03 Nos (m) Three phase power contacotr of range 3 to 16 A capacity - 01
Taking out the existing 3 HP capacity KSB make KRTU-65 Model Non clogging type submersible sewage pumpset from the sewage sump by disconnecting all incoming and outgoing sewage / elect connections carefully cleaning of strainer and impeller assy and re-installation at same position including commissioning and testing complete all as specified for the following capacity pumps. Note :- 1. The item rate includes the draining/emptying of sewage sump if required for taking out sewage pump.
M&L for Painting with one coat of synthetic enamel paint as per the existing colour by preparation of old surfaces for suction pipe/ delivery line of pump of any size complete all as directed.
M&L for Painting with one coat of synthetic enamel paint as per the existing colour by preparation of old surfaces for Sluice valve of size 80mm/100mm/150mm/200mm complete all as directed.
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts,check nuts and washers of brass as shown in electrical plate No. 5 of SSR part I including necessary excavation and earth work, GI Pipe 20 mm bore light grade for watering with Funnel,wire mesh, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle with lifting hooks, adequate quantity of charcoal dust and common salt etc including testing and taking out old unserviceable any type complete all as specified and as directed.
S& F Flexible nylon pipe heavy duty 1.5" dia all as specified and directed by Engineer-in-Charge.
S & F Submersible pump 3 HP of 415 V, 50 Hz, Three phase with protection of overload conditions / phase reversal / phase unbalance complete all as specified and as per the directions of Engineer-in-Charge.
Attending of day to day Water suuply complaint complete all as specified and as per the directions of Engineer-in-Charge. (Material should be measure and paid separately.
Removing and cleaning of Motor fan slot and Supply & Fixing in repairs of plastic Fan blade with suitable size enclouser of MS fan cover including the nut and bolts for tighting all as specified and directed by Engineer-in-Charge.
(a) 1-5 HP motor
(b) 5-15 HP motor
(c) 30-40 HP motor
Supplying & Laying in trenches Clear Sand/m- Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level complete all as specified and directed by Engr-in-charge. Note: Punned thickness only will be measured and paid.
Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete complete all as specified and directed by Engineer-in-charge.
Supply and fix or laying in trenches/on wall/poles/structures as in repairs GI tubing light grade of size 80 mm dia for road crossing/ for cable protection/ fixing of pigmi lights etc, of the following sizes including necessary provision for cable entry if reqd in pigmi lights pole, fixing MS nut, bolt & washers/ MS clamps complete as required complete all as specified and directed by Engineer-in-Charge.
All as per item No. 91.00 Here in before but of size 50 mm dia
All as per item No. 91.00 Here in before but of size 40 mm dia
Supply and fix in repairs GI tubing medium grade of size 80 mm dia for pigmi light pole with provision for pole foundationa and fixing of pigmi lights etc,of the following sizes or capacity including necessary provision for cable entry if reqd in pigmi lights pole, fixing MS nut, bolt & washers/MS clamps, reducer and requred complete as required complete all as specified and directed by Engineer-in-Charge. Note:- (a) pigmi light/street light will be measerd and paid separeatly under relivent items. (b) pole foundation or coping og foundation will be measerd and paid separeatly under relivent items. (c) Height of pole above the ground level is appx 1.4 mtr and fix in foundation 0.6 mtr will be cosidered in this items.
Supply and fix in repairs GI tubing medium grade of size 80 mm dia for pigmi light pole with provision for pole foundationa and fixing of pigmi lights etc,of the following sizes or capacity including necessary provision for cable entry if reqd in pigmi lights pole, fixing MS nut, bolt & washers/MS clamps, reducer and requred complete as required complete all as specified and directed by Engineer-in-Charge. Note:- (a) pigmi light/street light will be measerd and paid separeatly under relivent items. (b) pole foundation or coping og foundation will be measerd and paid separeatly under relivent items. (c) Height of pole above the ground level is appx 3.0 mtr and fix in foundation 0.6 mtr will be cosidered in this items.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for any description incl preparation work is necessary complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work / mass concrete for coping of poles/using at any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs Galvanised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl taking down/dismantling the old items complete in any sub station/installations structure complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Pin type porcelain vitreous,brown of white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Shackle type Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 100 mm and dia 115 mm having working pressure 1100 volts grade complete all as directed.
Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings etc) from various locations, Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 10 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and directed by Engineer-in-Charge. Note :- (a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and Sand for cushioning will be measured and paid separately. (b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape) new nut, bolt and washers of required size/description are deemed to include in this rate.
All as per item No. 101.00 but of size 2 core 16 sqmm
All as per item No. 101.00 but of size 4 core 16 sqmm
All as per item No. 101.00 but of size 4 core 25 sqmm
All as per item No. 101.00 but of size 3 1/2 core 35 sqmm
All as per item No. 101.00 but of size 3 1/2 core 50 sqmm
All as per item No. 101.00 but of size 3 1/2 core 70 sqmm
All as per item No. 101.00 but of size 3 1/2 core 95 sqmm
S & F in repairs LT heat shrinkable Straight through cable Jointing kit, complete with jointing material and accessories suitable for 2 core XLPE armoured Aluminium conductor cable of size 10 to 16 sqmm complete all as specified and directed by Engineer-in-Charge.
All as per item No. 109.00 but of size 4 core 16 to 25 sqmm
All as per item No. 109.00 but of size 3.5 core 35 to 50 sqmm
All as per item No. 109.00 but of size 3.5 core 35 to 70 to 95 sqmm
Material and labour for fault finding of LT cables of size 35 to 150 sqmm X 3.5 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of same existing size suitable to site requirement complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with GI earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32 x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engr-in-charge including demolish existing earth pit taking out old materials.
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any typecomplete all as specified and directed by Engr-in-charge including demolish existing earth pit taking out old materials.
S & F in repairs Energy efficient LED street Light Luminaire 60 watts capacity comprises a die-cast aluminium housing including connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded from LT over head line/junction box to the connector of fitting, (connection wires shall not be less than 2.5 metre in length duly run through GI bracket) complete all as specified and directed by Engineer-in-Charge. Make :- Bajaj or equivalent
All as per item No. 116.00 but of LED street Light Luminaire 72 watts capacity complete all as specified and directed by Engineer-in-Charge. Make :- Bajaj or equivalent
All as per item No. 116.00 but of LED street Light Luminaire 90 watts capacity complete all as specified and directed by Engr-in-charge. (Make :- Cat No BRTFG 90W LED I V2 or equivalent in Philips/Wipro/Luker)
All as per item No. 116.00 but of LED street Light Luminaire 120 watts capacity complete all as specified and directed by Engineer-in-Charge. Make :- Bajaj or equivalent
All as per item No. 116.00 but of LED street Light Luminaire 150 watts capacity complete all as specified and directed by Engineer-in-Charge. Make :- Bajaj or equivalent
S & F in repairs LED Cup type street Light Luminaire 20 watts capacity comprises a die-cast aluminium housing incl connections with 2 run of 2.5 Sq mm aluminium unsheathed wire multistranded run through GI bracket complete all as specified and directed by Engineer-in-Charge. Make :- Bajaj or equivalent
Supply and fix in repairs LED flood light fitting 180 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connectioncomplete all as specified and directed by Engineer-in-Charge. Make :- Bajaj or equivalent
All as per item No. 122.00 but of LED flood Light 200 watts capacity complete all as specified and directed by Engineer-in-Charge. Make :- Bajaj or equivalent
All as per item No. 122.00 but of LED flood Light 240 watts capacity complete all as specified and directed by Engineer-in-Charge. Make :- Bajaj or equivalent
Supply and fix in repairs smart integrated solar street light 18 W with built in Mono Crystalline panel, Lithium Ferro Phospate (LiFeP04) battery, MPPt Charge Controller and PIR sensor with colour Temperature 6000-6500K, including necessary fixing arrangement on PCC pole/wall by providing with necessary nuts, bolts and washers etc and making cable connection complete all as specified and directed by Engineer-in-Charge. Make:- Bajaj 18W All-in-one Standard
S & F in repairs Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape of approx length 1.0 mtr long suitable for security/street light fittings with necessary MS clamps - 02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Street light bracket made out of GI tubing 25 mm dia, light grade bend to shape of approx length 1.0 mtr long suitable for security/street light/Pigmi light fittings with necessary fixing arrangements -with one coat of red oxide and two coats of synthetic enamel paint including nut, bolt, washers etc complete all as specified and directed by Engineer-in-Charge.
Supply only LED driver with transformer suitable for 25 to 60 watts LED street/Flood/high bay light fitting of complete all as specified and directed by Engineer-in-Charge. Make:- Philips / Bajaj / Havells
All as per item No. 128.00 here in beforebut of capacity 70 to 90 watts LED fittings complete all as specified and directed by Engineer-in-Charge.
All as per item No. 128.00 here in beforebut of capacity 120 to 150 watts LED fittings complete all as specified and directed by Engineer-in-Charge.
M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in substation yard for laying complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated 3 core stranded copper conductor served with an inner sheathing of PVC tape PVC sheathed 2.5 sqmm nominal cross section in service connection/light connections in garden light from juction box to fittings complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 139 x 119 x 70 mm incl necessary suitable size new aluminium busbar single phase with neutral system mounted on saddles - 02 Nos of suitable length and thickness, provn of aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles complete all as specified and directed by Engineer-in-Charge. Make : Sintex/Hensal or equivalent
Supply and fix in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type (with metric knockouts for cable entry) of size 333 x 233 x 120 mm mm incl necessary suitable size with cable terminal assy mounted on saddles suitable for 3 phase with neutral system - 04 Nos of suitable length and thickness, provn of aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles complete all as specified and directed by Engineer-in-Charge. Make : Sintex/Hensal or equivalent
M&L for scraping of old paint from decorative poles for pigmi light appx length 3 mtrs and dia 40/50/80 mm, including breacket of pigmi light cleaning with emary paper and waste cloths, applying one coat of red oxide primer, and two coat of synthetic enamel paint by spray gun of desired colour complete all as specified and directed by Engineer-in-Charge. Note:- Colour of paint for pole is approved by Engineer-in-Charge.
M&L for scraping of old paint from decorative poles for pigmi light appx length 1.5 mtrs and dia 40/50/80 mm, including breacket of pigmi light cleaning with emary paper and waste cloths, applying one coat of red oxide primer, and two coat of synthetic enamel paint by spray gun of desired colour complete all as specified and directed by Engineer-in-Charge. Note:- Colour of paint for pole is approved by Engineer-in-Charge.
M&L for scraping old paint from metal surface, cleaning with cleaning agents and waste cloths, applying one coat of red oxide primer, and two coat of synthetic enamel paint by spray gun of desired colour complete all as specified and directed by Engineer-in-Charge.
M & L for removing vegitation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along with fancing, around the pole, under the HT / LT transmission lines, yards or any description by mannually/ mechanically and keep the sub station yard neat and clean complete all as specified and directed by Engineer-in-Charge. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid.
M & L for Cutting and trimming of tree branches of girth upto 150 mm dia and 3 mtr all around of any size obstructing lumination of street light/perimeter lights and touching LT/HT Over head line incl removing trimmed tree branches complete all as specified and directed by Engineer-in-Charge. Note ; Each cut will be measured and paid
Supply and fixing aviation obstruction light yellow painted die-cast aluminium alloy husing Integral LED aviation light comprising 302 nos. LED including giving electric connection and testing complete all as specified and directed. Make :- Bajaj or equivalent
Super Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .