Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC LAMBA LINE PB NO 414 JUNGLIGHAT PO PORT BLAIR A N 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹21.4 L Quoted ₹21.7 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹23.0 L+₹1.3 L (6.12%)Rejected-Finance | ₹23.0 L+₹1.3 L (6.12%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹23.8 L+₹2.1 L (9.85%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹23.8 L+₹2.1 L (9.85%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹24.7 L+₹3.0 L (13.8%)Rejected-Finance | ₹24.7 L+₹3.0 L (13.8%) | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
26 Sept 2020, 6:00 pmClosed
Shri Rajiv Ranjan, IDSE
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR MAINT CLEANING OF OVER HEAD RESERVOIR, UNDER GROUND SUMP AND SEMI UNDERGROUND SUMP AT VARIOUS LOC AND CLEANING SERVICE TANKS,STATIC TANKS AND CONNECTED WORKS AND REPAIR MAINT OF RAISING MAIN PIPE LINE, SLUICE VALVE, AIR RELIEASE VALVE AN
2020_MES_373060_1
8875/MB/PB/E8
Open Tender
Civil Works
Item Rate
360 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE, Minniebay
₹60,000
Yes
16 Dec 2020
29 Aug 2020
1 Oct 2020
29 Aug 2020
26 Sept 2020
12 Sept 2020
Amount
Excavating in trenches in soft / loose soil, n.exc 1.5m wide and n.exc 1.5m in depth: for foundation, etc, or for shafts, wells, cessapits, manholes, pier holes, etc. n.exc 10 Sq.m on plan and in.exc 1.5m in depth and getting out all as specified and directed
Excavating in trenches in hard / dense soil, n.exc 1.5m wide and n.exc 1.5m in depth: for foundation, etc, or for shafts, wells, cessapits, manholes, pier holes, etc. n.exc 10 Sq.m on plan and in.exc 1.5m in depth and getting out all as specified and directed
Returning, filling in using excavated soil including spreading, leveling watering and well ramming in layers n.exc 25 cms in any type of soil all as specified and as directed
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point all as specified and directed
Taking up UNSV / Serviceable CI Water Mains ( including fittings) with spigot and socket ends and lead joints from trench in any type/grade including burning out joints and recovering lead of following sizes all as specified and directed :-
80mm bore
150mm bore
200mm bore
250mm bore
M&L in replacement for DI pipes with spigot and socket ends centrifugally cast class LA in any length, laid in trenches of following sizes all as specified and directed :-
80mm bore
150mm bore
200mm bore
250mm bore
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store all as specified and directed for the following sizes all as specified and directed :-
20mm dia
25mm dia
40mm dia
50mm dia
80mm dia
100mm dia
S&F in replacement GI tubes medium grade galvanized with all fittings, laid in trenches/fixed on wall/on roof etc of the folloing sizes all as specified and directed :-
20mm dia
25mm dia
40mm dia
50mm dia
80mm dia
100mm dia
Taking down Gun Metal, globe or gate valves with iron wheel head of any type of the following sizes all as specified and directed :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and fixing Gun Metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of the following sizes :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and fix in replacement of flanged type Sluice valve hand wheel operated CI Body with SS spindle PN-1.0 rating, IS-14846 of following sizes
80mm bore
100mm bore
150mm bore
200 mm bore
250 mm bore
S&F in replacement of Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore CI / DI pipes as specified and directed.
S&F in replacement of Bends, Tappers, Tee Pieces (Single & double branch) any type and angle / radius and straight connecting piecs but all ends flanged upto 150mm bore CI / DI pipes all as specified and directed
S&F in replacement Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed ( Minimum weight 20mm - 210gms / 25mm - 455 gm) of following size all as specified and directed
20mm bore
25mm bore
40mm bore
M&L for cutting cast iron pipes and reducing to required length before laying in position for insertion of new tees, branches etc. of the following sizes :-
80mm bore
100mm bore
150mm bore
200mm bore
250mm bore
Dismantling / taking out UNSV MS Tank cover alongwith angle iron frame from the existing tank (RCC Tank) for requisite replacement (size 1400mmx1400mm) x 03 Nos
M&L for fabrication of MS tank cover made out of Angle iron (40x40x5mm for frame) and MS sheet 3.0mm thick Make Tata or Equivalent including necessary welding, grounting etc and locking arrangement complete all as directed.
M&L for Gland packing 8 mm/12.5mm dia / thick for sluice valve / pumps to arrest the water leaking from the pumps and valves with proper gland packing.
S&F in replacement run lead joint suitable for spigot and socket pipes and fittings for the following size as specified and directed
80mm bore
100mm bore
150mm bore
200 mm bore
250 mm bore
M&L for fabrication of MS sheet (2.0)mm thick) M for valve chamber cover with plates of Fe 410W, Gde E-250, quality -A (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment for locking arrangements complete including painting with two coat of synthetic enamel paint black colour/shade over a coat of redoxide primer complete all as specified and directed including taking down old one.
Cleaning of service tanks insatlled on roofs of multistoryed buildings at various places by emptying the tanks, by removing the scale, dirt and all other foreign materials depositing inside nipples on side of walls and bottom of the tanks by scrapping and brushing with wire brush, and pressure pump, cleaning with bleaching powder slurry and allowed to dry and then washing the tank with fresh water and writing on the tank the date of cleaning, capacity of tank etc shall be written on the out side of the tank with synthetic enamel paint with letter size 10 cm high and 6cm width in white colour, over a black background of size all as specified and directed for the following sizes:- Note:- (I) Any air lock/blockage complainats shall be attended by the contractor during the cleaning process with out any extra cost. (II) Tank covers and Float valve shall be fitted properly after completion of cleaning. (III)Contractor should produce tank cleaning register duly signed by the users / occupants along with phone number to maintain records. JE / Engineer-in-Charge shall verify the same.
Tanks of capacity exceeding 250 ltr but not exceeding 500 ltr
Tanks of capacity exc 500 ltrs and not exc 750 ltrs
Tanks of capacity exc 750 ltrs and not exc 1000 ltrs
Tanks of capacity exc 1000 ltrs and not exc 2000 ltrs
Tanks of capacity exc 2000 ltrs and not exc 5000 ltrs
Tanks of capacity exc 2000 GL and not exc 5000 GL
S&F in replacement of Rotational moulded polyetheylene water storage tanks (cylindrical vertical with closed top) double layer with lid and providing proper locking arrangements etc, hoisted and fixed in position all as specified in SSR Part-II all as specified and directed
500 ltr capacity
750 ltr capacity
1000 ltr capacity
1500 ltr capacity
2000 ltr capacity
5000 ltr capacity
S&F in replacement PVC tank cover suitable for service over head tank including necessary fixing arrangements of following capacity
500/750 /1000 ltr capacity
1500/2000 ltr capacity
5000 ltr capacity
Cleaning of RCC overhead reservoirs/semi under ground sump / Static tanks/ suction gallery of following capacity situated at various places under AGE E/M-II Minniebay by emptying the reservoirs, taking down the scale/sludge/mud/algae formed including and other foreign materials got deposited on side of walls and bottem of the tanks by scrapping and brushing with wire brush,cleaning with pressure pump,washing with bleaching powder slurry and allowing to dry and then washing and cleaning the tank with fresh water including applying one coat of white wash on internal surface of reservoirs / sumps and written details on tanks like date of cleaning ,capacity of tanks etc on the out side of the tank with synthetic enamel paint with letter size 20 cm high,10cm width in white colour,over a black backgroung of size 100 x 60 cm,all under ground and semi under ground sumps outer surafce shall be painted with syntetic enamel paint of colur as directed for the following sizes:- Note:- The photographs of OHR,sumps before and after cleaning be submitted to Engineer-in-Charge for records.
Over Head Reservoiers of capacity 50000 gallons on 12 to 18 mtr stagging at Minniebay area
Over Head Reservoiers of capacity 30000 gallons on 15 to 20 mtr stagging at Minniebay (Ajay Baugh 6th lane).
Over Head Reservoiers of capacity 20000 gallons on 15 to 20 mtr stagging at Minniebay (Srinagar Area and Ajay Baugh 7th lane).
Underground sump of capacity 2 lakh galloons at Minniebay pump house using dewatering cum mud pump set for bailing out of water
Semi underground sump of capacity 50000 gallons at NCS
Semi Under Ground level sump of capacity 30000 gallons at command swimming pool.
Fire Static tanks of capacity 50000 Ltrs to 1,00,000 Ltrs
M&L for taking out centrifugal pump set of capacity 30/40/50/60 HP, Dismantling of Pump from the base plate and motor, transporting to civil workshop for requisite repair ,segregation of serviceable/unserviceable spare parts, carry out servicing and taking back to site including refixing the same in its original position including proper alignment and testing on completion to the entire satisfaction of Engineer-in-Charge including painting the complete pump set (Pump & Motor) with two coat of synthetic enamel paint Sky blue colour / shade after preparation of existing / old painted surface all as specified and as directed.
Supply only of following UNSV spare parts of pump set capacity 30/40 HP as suppy only.
Flexible Nylon tube 8X6 mm make:- Poly hose
Tyre Coupling as per existing size & No. TC/P/014 PX2514
Impellar CI
Shaft SS
Stuffing box Bush SS
Gland plate
Metal coupling
CI Cassing wear ring
Ball bearing DE 6278
Ball bearing NDE-6248
GM impeller nut
Nut bolt washer 3/4" x 2 1/2" size
Nut bolt washer 16 x 75 mm size
Stud with nut 19 / 95 mm
Gland packing
Key for impeller
All as per item No.26 here in before but of 60/50HP,37/45 KW, 2955/1470 RPM
Only Shaft SS
Metal coupling
Impellar CI
Stuffing box Bush SS
Check nut SS
Key for impeller
Neck ring
Ball bearing DE 6308
Ball bearing NDE 6304
Gland packing
Nut bolt washer 3/4" x 2 3/4" size
Nut bolt washer 16 x 80 mm size
Bearing housing
M&L for dismantling of MS base plate of the pumping set with foundation bolt of pump and motor capacity 30 HP to 60 HP including demolition of existing PCC foundation etc for requisite repair / replacement here-in-after complete all as specified and as directed.
S&F in replacement of pressure gauge analog type of capacity 0 to 10.60 Kg/ cm2 (0 to 150 lb/ Sq inch) of Dial size 100 mm dia all as specified and as directed.
S&F in replacement Fully automatic star-Delta starter suitable for 30HP / 40HP Motor of centrifugal pump including voltmeter, Ammeter, Indicator, OL protector, SP preventer, relay etc complete with suitable factory made sheet enclosure.
S&F in replacement Fully automatic star-Delta starter suitable for 50HP / 60HP Motor of centrifugal pump including voltmeter, Ammeter, Indicator, OL protector, SP preventer, relay etc complete with suitable factory made sheet enclosure.
S&F in replacement cast iron Butterfly valve 250 mm dia including provn of new rubber gasket,nut,bolt,double washer etc. complete
M&L for Painting to GI / CI water pipe line including Sluice Valves,valve chambers, NRV etc with two coats of synthetic enamel paint of black colour/shade or approved colour duly preparing the existing painted surfaces to the entire satisfaction of Engineer in charge of following dia of pipes :-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
350 mm Dia
400 mm Dia
Supply & fixing in replacement Cast iron foot valve heavy duty both end flanged including confirming to relevant IS fixing with provn of new rubber flange gasket ,nut,bolt, double washer etc complete of following sizes all as specified and as directed.
150 mm bore
200 mm bore
250 mm bore
Supply and fix flanged Non return valve flap type, cast iron body, PN1.6,confirming with IS provision of 3mm thick rubber gasket on both sides of the flanges, bolts and nuts complete including dismantling of unserviceable valve all as directed of following sizes :-
200 mm dia bore
150 mm dia bore.
Supply and in repairs with existing Air release valve by remvoing the valve and repairing the same by replacing gaskes,nut,bolts, top and ball refixing the same , cast iron body, on both sides of the flanges, bolts and nuts complete of following sizes :-
80 mm dia bore
100 mm dia bore.
M&L for Schematic diagram for water supply distribution,Details for pump motor at Minnie bay pump hosue and swimming pool duly framed with lamination sheet cover appropriate size as directed
Testing of water samples and obtain the test result for the perametrs as per IS 10500 like TDS,Colour,odour,TSS,PH,coliform turbidity,etc by carrying physical,chemical,microbiology examiniation from any govt authoarised /NABL approved laboratary and source/location of water samples all as specified and directed.
ANITA VARMA ENTERPRISES
Kathir Marketing Services
SHUSHANT ASSOCIATES
Bidder Name
Kathir Marketing Services
SB ENTERPRISE
ANITA VARMA ENTERPRISES
SHUSHANT ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .