Tender Value
₹11.4 L
EMD Value
₹22,780
Closing Date
22 Jun 2024, 2:00 pmClosed
Executive Engineer Electric Division Batote
Executive Engineer Electric Division Batote
Supply Survey Erection Testing and Commissioning for creation of 100 KVA sub station along with HT Line at BOREWELL CHAMALWAS UPPER SHALGADI under WSS Chamalwas JJM under the Jurisdiction of Electric Division JPDCL Batote
2024_PDD_249672_1
e NIT no 13 of 2024-25
Open Tender
Electrical Works
Turn-key
30 days
Banihal
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Executive Engineer Electric Division Batote
₹22,780
Yes
Executive Engineer ED Batote Oice
3 Sept 2024
10 Jun 2024
24 Jun 2024
10 Jun 2024
22 Jun 2024
10 Jun 2024
10 Jun 2024 - 15 Jun 2024
15 Jun 2024
Amount
Erection of HT line on 9 mtrs ST Poles with 30mmsq Conductor at BOREWELL CHAMALWAS UPPER SHALGADI on Turn key basis
9 Mtr ST pole (ST-410 SP 33)
CI Cross Arm with top bracket including Clamp
CI Channel x-Arm including Clamps and braces
11 KV Polymer Composite Pin Insulator
30 mm Sq ACSR Conductor
PG Clamps for 30 mm sq ACSR Conductor
11 KV Polymer Composite Disc Insulator
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti Climb Device With Clamp
Earthing of Pole
Red Oxide
Aluminnium Paint
Cement Bottomming 1:2:4 mix as per REC Standard
Aluminium Jointing Sleeves
Galvanised Stay Set Complete
CREATION OF 100 KVA SUB-STATION AT BOREWELL CHAMALWAS UPPER SHALGADI.
11/0.433KV, 3-phase Al. wound 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type
11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type
11 kV Horn Gap Fuse Set 3 Phase 3 pole, 200 Amp
70 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-540 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Chainlink Fencing of Sub station Yard by way of mass concrete in foundations and chain link fenscing of 6 Ft Height.
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm &depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mmx10 mm & 50mmx6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution box fitted witrh 120 Amps MCCB Havells Make
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Prodigy Meter
M/S K.K ELECTRICALS
Malik Brothers Electrical Contractor and Suppliers
M/S SURYA ENTERPRISES
MR INFRA ASSOCIATES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .