Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹7.6 LAWARDED | AWARDED |
Tender Value
₹7.6 L
EMD Value
₹22,500
Closing Date
30 Dec 2025, 10:30 pmClosed
Directorate of Municipal Administration
Electrical pole shifting near indrali english medium school road and transformer and pole shifting near kalsanka bridge in Udupi CMC limit
DMA/2025-26/EL/WORK_INDENT52948
DMA/2025-26/EL/WORK_INDENT52948
Open
Electrical
Electronic Documents, First(One Cover)
DMA City Municipal Council Udupi
₹500
₹22,500
22 Dec 2025
22 Dec 2025
29 Dec 2025
Electrical pole shifting near indrali english medium school road and transformer and pole shifting near kalsanka bridge in Udupi CMC limit
Digging of Pit 2.5 Mtr depth for erection of 11 Mtr long Tubular Spun Pole as per approved Drawing-Ordinary Soil-ESCOMs SR 2023-24,Page No:-43,Item No;-1.5.1.
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing-Ordinary Soil-ESCOMs SR 2023-24,Page No:-43,Item No;-1.1.1.
Supplying of Pre-Stressed Tubular Spun Pole - 11 Mtr Long, 500 Kg
WL(Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158: 1991-ESCOMs SR 2023-24,Page No:-03,Item No;-1.07.
Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr
depth (Mechnised Labour)ESCOMs SR 2023-24,Page No:-44,Item No;-2.05.
Supplying of PSCC Pole - 9 Mtr Long, 200 Kg WL
(Dwg No. BESCOM/GM/QS&S/50 Dtd 24.11.2018) as per REC Standards-ESCOMs SR 2023-24,Page No:-03,Item No;-1.06.
Supplying of RCC Pole - 9 Mtr Long, 145 Kg WL
(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785-ESCOMs SR 2023-24,Page No:-03,Item No;-1.01.
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8Mtr depth -ESCOMs SR 2023-24,Page No:-44,Item No;-2.02.
Supplying of 11 kV, Special 3 Pin Cross Arm - GI -ESCOMs SR 2023-24,Page No:-03,Item No;-2.04.
Fixing of V-Shape/Horizontal cross arm including Single Top
Support Brace and Insulator fixing -ESCOMs SR 2023-24,Page No:-45,Item No;-5.03.
Supplying of LT 4 Pin Cross Arm - GI -ESCOMs SR 2023-24,Page No:-04,Item No;-2.06
Fixing of 4 Pin cross arm with Insulator and Braces fixing-ESCOMs SR 2023-24,Page No:-45,Item No;-5.02.
Supplying of Rabbit ACSR(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM-ESCOMs SR 2023-24,Page No:-05,Item No;-7.02.
Stringing of Rabbit ACSR Conductor (including pin binding, providing jumps, dead ending, etc.,)-ESCOMs SR 2023-24,Page No:-46,Item No;-7.06.
Digging of Pit for providing GI Pipe type Earthing-Ordinary Soil-ESCOMs SR 2023-24,Page No:-43,Item No;-1.6.1.
Providing and Installing GI Pipe Earthing for lightning arresters,Transformer neutral and transformer metal parts(Excluding digging of pits)- Ordinary Soil
Digging of Pit for GUY SET(Ordinary Soil)-ESCOMs SR 2023-24,Item No:-1.7.1,Page No:-44
Supplying of 7/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM-ESCOMs SR 2023-24,Item No:-5.10,Page No:-45
Fixing of GUY Set with No.8 with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of P...
Supplying of 11 kV, 200 Amps Single Break GOS
(Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018)-ESCOMs SR 2023-24,Page No:-11,Item No;-24.01.
Fixing of GOS including wiring (11 kV Single Break 200
Amps) -ESCOMs SR 2023-24,Page No:-48,Item No;-13.02.
Supplying of 11 kV, HG Fuse Unit with Solid Core Insulator
(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)-ESCOMs SR 2023-24,Page No:-09,Item No;-20.01.
Fixing of 11 kV, HG Fuse Unit with Solid Core Insulator
Supplying of LT Protection Kit
(Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018)-ESCOMs SR 2023-24,Page No:-09,Item No;-17.01.
Fixing of LT Protection Kit-ESCOMs SR 2023-24,Page No:-49,Item No;-15.03.
Supplying of LT Distribution Box for 100 kVA DTC with MCCB's
(Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018)-ESCOMs SR 2023-24,Page No:-09,Item No;-18.01.
Wiring of 1 Circuit of LT Wiring for for 25/63/100 kVA DTC
to the existing LT protection Kit/Distribution Box via metering
box. (includes fixing of necessary supports like 2 Pin cross
arm, Spacer etc)...
Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long
Poles as per IS-1977-For 25/63/100 kVA 4/5 Star Rated Transformer on
RCC Pole - 9 Mtr Long, 145 Kg WL - GI-ESCOMs SR 2023-24,Page ...
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transforme...
Releasing and refixing of Rabbit ACSR Conductor.
Releasing and refixing of Double Pole TC sets for 100/300KVA Transformer-GI.
Releasing of 11KV Horizontal X arms-MS.
Dismantling of RCC Pole-9.0M long 145Kg WL
Dismantling of Double Pole TC sets for 25/63KVA Transformer-MS.
Dismantling of LT Protection Kit
Dismantling of 11kv 200Amps Single break GOS
Supplying and Fixing of 33kV Composite Disc Insulator-ESCOMs SR 2023-24,Page No:-69,Item No;-6.01.
Supplying and Fixing of 33kV Polymer Pin Insulator-ESCOMs SR 2023-24,Page No:-69,Item No;-6.02.
Supplying and Fixing of Strain Clamp, 3 Bolt type for 70/90 kN Disc Insulator-ESCOMs SR 2023-24,Page No:-05,Item No;-5.16.
Supplying and Fixing of P.G clamp-coyote to coyote-ESCOMs SR 2023-24,Page No:-06,Item No;-9.01.
Supplying of Coyote ACSR-KPTCL SCHEDULE OF RATES 2023-24 SR ,Page No:-44,Item No;-20.6.
Stringing of Coyote ACSR
Stringing of Rabbit ACSR Conductor (including pin binding, providing jumps, dead ending, etc.,)-ESCOMs SR 2023-24,Page No:-46,Item No;-7.06.
Supplying of Spiral earth electrode-ESCOMs SR 2023-24,Page No:-04,Item No;-2.16.
Providing Spiral Earth Electrode type earthing (without
charcoal, salt etc.,) -ESCOMs SR 2023-24,Page No:-44,Item No;-2.08
Digging of Pit for GUY SET(Ordinary Soil)-ESCOMs SR 2023-24,Item No:-1.7.1,Page No:-44
Supplying of 7/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM-ESCOMs SR 2023-24,Item No:-5.10,Page No:-45
Fixing of GUY Set with No.8 with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of P...
Supplying and Fixing of11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mmdia FRP Rod)--ESCOMs SR 2023-24,Item No:-6.06,Page No:-05
Supplying and Fixing of 1.1 kV Polymeric Pin Insulator--ESCOMs SR 2023-24,Item No:-6.05,Page No:-05
Supplying and Fixing of 11 kV, 45 kN Polymeric Insulator--ESCOMs SR 2023-24,Item No:-6.10,Page No:-05
Releasing and Refixing of over head service mains(single phase/three phase)for consumer installation and street lighting and similar work(while replacing existing pole)-Piercing connector suitable for...
Releasing and Refixing -RCC Pole-9.0M Long 145kg WL-Ordinary Soil
Releasing and Refixing -Coyote ACSR conductor-Ordinary Soil
Releasing and Refixing -Pre Stressed Tubular Spun Pole 11 Mtr Long-500kg WL-Ordinary Soil
Releasing and Refixing -11KV Horizontal cross arm with single top support,clamp,Bolt & Nut with washers for RCC Poles-MS-Ordinary Soil
Releasing and Refixing -4 Pin cross arm with Pole clamp,Bolt & Nut with washers for RCC Poles-MS-Ordinary Soil
Releasing and Refixing -Special Cross Arms Set-with EG Stirrups,Braces,Clamps,Bolts Nuts and Washers -Ordinary Soil
Pole Concreting with CC 1:2:4(without coping), 11 mtrs spun pole(1000x1000x2500mm)
Base concreting with CC 1:4:8, Pole base 11 mtr spun pole(1000x1000x150mm)
Releasing and refixing of Rabbit ACSR Conductor.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .