Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance F 2 87 88 SEC 11 ROHINI DELHI 85 | 85 | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical As per Technical Evaluation Committee Report. |
| 3 | Rejected-Technical | Rejected-Technical As per Technical Evaluation Committee Report. |
Tender Value
₹46.0 L
EMD Value
₹91,970
Closing Date
6 Dec 2024, 2:00 pmClosed
AGM EM
FCI RO Lucknow
Improvement of Security Lighting with LED street lights and power supply at FSD Raebareli under DO Lucknow.
2024_FCI_836767_4
EM/04/2024-25
Open Tender
Electrical Works
Item Rate
90 days
FSD Raebareli
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹91,970
30 Mar 2025
27 Nov 2024
9 Dec 2024
27 Nov 2024
6 Dec 2024
27 Nov 2024
Amount
Supply of PVC sheathed L.T. ABC Cable of 1.1 KV Grade Al Conductor cable as reqd as per IS-14255 3X70 + 1X16 + 1X50 sqmm
Erection of ABC Cable on existing poles including fixing accessories as reqd.
Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size.
3.5X50 sqmm
4X16 sqmm
4X10 sqmm
2X10 sqmm
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 50 sq. mm (35mm)
4X16 sqmm (28 mm)
4 X 10 sq. mm (25mm)
2 X 10 sq. mm (19mm)
Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 40 mm dia (OD-40 mm & ID-35 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Upto 35sqmm
Above 35sqmm to 95sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3metres length along the pole for protection of underground cable as required.(conforming to IS-1239 part 1 (2004) or equivalent)
Supply of steel Tubular pole 8.5 to 9.00 mt with Red oxide painted 410/SP.-29 swaged type steel tubular pole in single part along with 300X300X6 base plate & 100X3 top cap(Confoming to IS 2713 (PART I TO III) : 1980 or equivalent with upto date amendments ) as per directions and approval of engineer-in-charge
Erection of metallic pole of above 8 meter and upto 10 meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (Confoming to relevent BIS/IS standard or equivalent)
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required (Confoming to relevent BIS/IS standard or equivalent)
Supply and Fixing of 9 mtrs single section Hot dip Galvanized(as per BS EN ISO 1461) octagonal Street light pole (specification not less than, top dia 70 mm, Bottom dia 155 mm & base plate 260mm*260mm, 16 mm thickness IS-2062, 4 Nos. of "y'" type 24mm dia.,750mm length, with projected length of 125mm, Foundation bolts) having 3 mm thickness, of grade S355 and a vandal resistance, water proof door opening of approximate 500mm length at an elevation of 500mm from base plate for cable connection and including of GI bracket (of minimum 1000 mm length each from pole) supporting to min 02 street lights, on RCC foundation grade- M20 with base of depth 1250 mm including 250 from Free Ground level and width of 450 mm including the cost of foundation bolts, excavation and back filling complete in all respects as required as per relevant BIS/IS standards. as per directions and approval of engineer-in-charge
Supply , Installation, of suitable size 3mm phenolic laminated sheet having 1 nos. terminal having 5 point for 3 phase, 1 netrual & 1 earth on and 1 no. SP MCB 5/6A , interconnection etc are required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts,bolts and washer, painting the flat iron with primer and finish paint etc. as required. (conforming to IS-1239 part 1 (2004) or equivalent)
Supply of 120W pressure Die cast aluminium housing streetlight with system lumen of minimum 16800lm & system efficacy of 140Im/W, IP66, IK10, Single piece die cast including spigot, dia 48-76mm,with integrated optical cover. Streetlight should have standalone lighting control system with AUTO on/off based on Dusk/Dawn timings, preset time setting with monthly variation(Jan to Dec.), inbuilt Real time clock for switching, includes dimming profile for energy savings, drift not exceeding max 2mins per year, clock retention upto minimum two years, auto switching off secondary power for module, dimmable driver based on PWM control, dim to off with High/Low Voltage cut off with 440V protection for 8 hrs for complete luminaire including driver and Astro module, EMI/EMC complaint as per EN55015,IEC61547.surge protection as per IEC 61000-4-5,driver meeting IEC61347,complete luminaire meeting IEC60598-2-3-2002, Luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval as per directions and approval of engineer-in-charge
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (Confoming to relevent BIS/IS standard or equivalent)
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. (Confoming to relevent BIS/IS standard or equivalent)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (conforming to relevant BIS/IS codes)
S/I/T/C of weather proof 3 phase SMC MOULDED SERVICE CONNECTION BOARDS / Busbar box for AB Cables with pole mounting arrangement, with cable entry from bottom or sides and Busbar for high fault currents(Confoming to relevant BIS/IS standard or equivalent)
Supplying , installation , testing and commissioning of cubical type,inverted V shaped top, outdoor feeder pillar panel with size (1.0x1.0x.4 Mtr) suitable for operation at 415 (+/-) 6% Volts,50Hz,3 Phase 4 Wire system made out from CRCA sheet steel 2.0 mm and covers shall be cold rolled sheet thickness not less than 1.6mm fabricated factory finished followed-42 by powder coated painting & provided with gaskit etc. to make dust & vermin proof degree of IP ,Weather Proof, hinged type openable door , loaking arrangement , detachable gland plate , connection , interconnections with suitable size (150 Amp capacity) 4 strip high conductivety elctrical aluminium (ALU) busbar codifies in red,yellow,blue and black colour and PVC insulated copper conductor cable 1100Volt grade for internal wiring including providing and fixing digital type Ampere meter, Voltmeter, Indication LED lamp, ,Labeling comprise white letters on black background including foundation works etc as required with following:- (Confoming to relevent BIS/IS standard or equivalent) 1)4P MCCB 125Amps,36KA-01No 2) 4P MCCB 100 Amps.36KA-01 Nos 3) 4P MCCB 63 Amps.25KA-04 Nos 4) MCB DP 40 Amps -02 Nos 5) TPN MCB 63Amp-02 Nos 6) 4 strip AL Busbar 150Amp- 01 Set
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .