EE (Civil)
BSNL Civil Division Srinagar 2nd floor TE building Lal Chowk Srinagar
Supplying and installing of 08 nos BTS Shelters Porta cabins for Leh Chusul Thakung ITBP Link Project under Leh BA of BSNL J and K Circle SH Supply and Installation of BTS Shelters
2025_BSNL_222797_1
36/EE/DIV/SGR/2024-25
Open Tender
Civil Works
Item Rate
60 days
Leh
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Accounts officer (Cash), Jammu
₹1.6 L
17 Jan 2025
4 Jan 2025
16 Jan 2025
4 Jan 2025
14 Jan 2025
4 Jan 2025
Amount
Supplying and fixing at site prefabricated BTS shelter of specified internal dimensions made of standard Sandwich insulated panels 80mm thick with Polyurethane Foam (PUF) as filler material between galvanized pre-coated steel sheets of thickness 0.60mm. The shelter shall be designed for floor loading as 1000Kg/Sqm, harsh environment condition (-15 Degree Celsius to 60 Degree Celsius) and survival wind speed of 200Km/hour. The roof load capacity shall be 200kg/Sqm. The floor shall consist of standard PUF sandwich panels 80mm thick covered with 18mm Marine Plywood. Antistatic flooring 2mm thick using antistatic vinyl robust rolls shall be laid on marine ply flooring. The roof shall be made of standard PUF sandwich panels 80mm thick. A down slope 1:50 shall be maintained from front to back.
The main door shall be of dimension 1000 W X 2000 H (mm) and opening outwards. It shall be sealed by a peripheral (double) sealing frame with silicon rubber /EPDM gasket, splash and dust proof. The door shall be hinged with minimum four Nos. of heavy duty hinges (stainless steel/Brass). It shall also be provided with a hydraulic door closer. The door should be closed by means of three way espagnolette lock with locking cylinder in door handle. The door should be openable from inside when locked. Door, when locked, can not be removed even if hinges are removed. The panel to panel jointing in the walls shall be done by tongue and groove configuration with use of minimum three nos. of eccentric cam locks. Minimum three nos. cam locks shall be used for wall to wall, wall to roof and base to wall. The joints shall be strengthened with tie rods/tie bars/clamps/angle iron/corner plates etc.
All panel joints shall be sealed with silicon sealant for water proofing. The shelter shall have provision for openings for AC/Exhaust Fan/piping/cabling/wave guides and feeder cables. All opening shall be custom built and cutting shall be done at site and provided with suitable glands and apertures. The glands shall be EPDM. The shelters shall be provided with AC protection cage of specified dimension and VANDAL PROTECTION arrangement for protecting AC against theft. All metallic parts shall be interconnected for good electrical connectivity. A long copper strip/bar of size 300 x 25 x 5mm with M8 bolts size rounded holes and insulator in it shall be provided near the door inside the shelter. The shelter design shall be vetted from a reputed structural authority like SERC/IIT for temperature range, snow load [2.5 KN/Sqm or 1 metre snow depth], wind speed 200Km/Hr.
The structure should be resistant to rain/dust/sand/corrosion against water/industrial air/saline air/decomposing vegetation/rodents /termites & micro organisms. The shelter shall be installed on base frame of galvanized ISMB 200 x 100mm supported on concrete foundation. The Base frame ISMB along with Stair access (3 Nos. of steps) with 15 cm riser in each step, to be supplied by vendor with shelter material. The shelter shall be constructed such that it can be transported in dismantled form to the site and assembled there at the site. All other requirements shall be conforming to the GR No. TEC/GR/PI/BSH-001/02/SEP-11.
Shelter of internal dimensions 4000 L X 3500 W X 3000 H (all in mm) [Type-II] at following locations
NFS Node Karu
NFS Node Tangste
NFS Node Parma
ITBP Chushul
ITBP Thakung
Shelter of internal dimensions 5000 L X 3500 W X 3000 H (all in mm) [Type-III] at following location
ITBP Leh
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .