Loading…
Loading…
Tender Value
₹56.1 L
EMD Value
₹1.1 L
Closing Date
18 Sept 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
Above/Below/Par
SIG WORKS
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where: V= Advertised value of the tenderin crores of Rupees N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractualturnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the auditedbalance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourthprevious year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information asper Annexure VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from CharteredAccountant duly supported by Audited Balance Sheet As per Clause No. 10.2 of Tender Form (second Sheet) of Annex. I of Part-I of GCC-2022,with up to date correction slip.
The tenderer must have successfully completed or substantially completed any of the following categories of work(s) during last 07(seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than theamount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of theadvertised value of the tender, or (iii) One similar work each costing not less than the amount equal to 60% of the advertised value of the tenderWork experience certificate from private individual shall not be considered. However, in addition to work experience certificates issuedby any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore andabove in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay StockExchange,incorporated/registered at least 5 years prior to the date of closing of tender,shall also be considered provided the work experiencecertificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits workexperience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy ofwork order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all paymentsreceived and copy of final/last bill paid by company in support of above work experience certificate. As per Clause No. 10.1 of Tender Formsecond Sheet of Annex. I of Part-I of GCC 2022, with up-to-date correction slip.
Definition of similar work: "Any Signalling Work "
62 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer should note that tender will be dealt as per GCC 2022 and latest amendments to it.
Rates in the schedule items of work are inclusive of all taxes as per clause 37 of GCC-2022
Wherever there is any ambiguity in SOR Item Description, that particular item description in latest RDSO Specification to be considered as FINAL.
Telecom Circular No. 09/2023 (copy attached) shall be religiously followed for undertaking digging work in the vicinity of Signalling, Electrical and Telecommunication Cables. Zonal Railways issued local instructions/JPO for protection of cables while undertaking works in the vicinity of Railway Tracks in line with Telecom Circular 09/2023.
S&T work for Construction of ROB in lieu of existing LC no.86 At Harsauli yard in Alwar-Rewari Section of Jaipur Division.
SNT-JP-18-2026-27~NWR
SNT-JP-18-2026-27
Open
Works - General
6 Months
Jaipur, Rajasthan
₹0
₹1.1 L
18 Sept 2026
25 Aug 2026
4 Sept 2026
121 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 53,29,411.45 | ||
| — | 1.00 | — | — | ||
| Preparation of SWR literature in English along with associated mid-section interlocked gate with all corrections as per approved SWRD & approved SIP. For these all-technical corrections, editing, grammatical correction etc. are to be carried out and one rough print to be given to railways for approval before printing, as required for final processing of CRS sanction. This also includes preparation of maintenance cards in format provided by Rly.Inspection: ConsigneeInspection charges: NonePayment terms:100% after execution. | — | — | — | 4,330.94 | |
| — | 1.00 | — | — | ||
| Translation of Station Working Rules from English to Hindi and framing out in DIGLOT form (or similar software) as per extant Rly practice. The required SWR in English will be provided by the contractor and has been covered separately in item no. 01011800 of Chapter 1 of SOR.Inspection: ConsigneeInspection charges: NonePayment terms:100% after execution. | — | — | — | 5,389.49 | |
| — | 6.00 | — | — | ||
| Making photocopies & binding of the SWR literature in English/Hindi/Diglot form as per Railway practice.Inspection: ConsigneeInspection charges: NonePayment terms:100% after execution. | — | — | — | 1,289.1 | |
| — | 1.00 | — | — | ||
| Designing and Plotting of Signalling Interlocking Plan (SIP) in AUTOCAD.Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed byRailways then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station.Inspection: ConsigneeInspection charges: NonePayment terms:100% after execution. | — | — | — | 33,772.62 | |
| — | 100.00 | — | — | ||
| Preparation and supply of laminated one set of all the completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets xerox copies will also be provided for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection table, Locking table, Contact analysis, Fuse and Tag Block analysis of Relay Rack, CT rack, Control cum Indication Panel/VDU Diagram, Power Panel Diagram, Track circuit plan, rack erection plan and Junction Box details etc.Inspection: ConsigneeInspection charges: NonePayment terms:100% after execution. | — | — | — | 19,385 | |
| — | 60.00 | — | — | ||
| Addition/alteration in existing relay room wiring. It includes supply of PVC insulated indoor Railway signalling cable @ 40<45@Core/40-Core) of (1/0.6) sqmm as per RDSO Spee. No. IRS/S-76/89 (Amnd.2 or latest) for wiring between relay room and SM's/Panel room & Relay room to DP in SM office for block working. This also includes supply of PVC insulated jumper wires of multi strand 16/.2 mm, tinned in all colours as per RDSO Specn.No.IRS-S-76/89(Amnd.2 or latest). This item will include bringing all the power supplies from power room to respective bus bars on relay racks by using 10/6 sqmm copper flexible wire as per instructions of engineer incharge. This will include wiring between control panel and relay room if required. All wiring will be done as per standard practice of North Western Railway with neat dressing & threading. The item includes supply & wiring of tag block, fuse with bases (G-Type and ND Type) and all other related material required for complete indoor wiring in relay room.Inspection: ConsigneeInspection charges: NonePayment terms:100% after execution. | — | — | — | 37,845 | |
| — | 30.00 | — | — | ||
| Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDE".Inspection: - RDSOInspection charges: - Borne by RailwaysPayment Terms: - 100% after supply. | — | — | — | 1,42,382.1 | |
| — | 5.00 | — | — | ||
| Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized with different ward combinations and contact configuration 4F/4B with 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 or latest, confirming to IRS S-23, S-34 & S@ 45<44@ IRS S:46.Inspection: - Consignee.Inspection charges: - None.Payment Terms: - 100% after supply. | — | — | — | 56,805.2 | |
| — | 30.00 | — | — | ||
| Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDF".Inspection: - RDSOInspection charges: - Borne by RailwaysPayment Terms: - 100% after supply. | — | — | — | 1,36,815.3 | |
| — | 165.00 | — | — | ||
| Supply of Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity.Inspection: RDSOInspection Charges: Borne by RailwaysPayment Terms: 100% after supply. | — | — | — | 11,751.3 | |
| — | 2000.00 | — | — | ||
| Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg. No. SA-23741A (Alt. 4) or latest.Inspection: RDSO.Inspection Charges: Borne by Railways.Payment Terms: 100% on supply. | — | — | — | 2,10,400 | |
| — | 2000.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after execution | — | — | — | 20,360 | |
| — | 60.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc.Inspection: RDSOInspection Charges: Borne by RailwaysPayment Terms: 100% after Supply. 2V, 300AH | — | — | — | 5,09,770.8 | |
| — | 60.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc.Inspection: RDSOInspection Charges: Borne by RailwaysPayment Terms: 100% after Supply. 2V, 500AH | — | — | — | 8,12,485.2 | |
| — | 120.00 | — | — | ||
| Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of N.W.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after Execution. 2V, 300AH/ 500AH | — | — | — | 1,42,503.6 | |
| — | 8.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Spec. No. IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery.Inspection: RDSOInspection Charges: Borne by RailwaysPayment Terms: 100% after Supply | — | — | — | 43,375.28 | |
| — | 8.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA-20161-66/M or latest. Inspection: RDSOInspection Charges: NonePayment Terms: 100% after Supply. | — | — | — | 13,856.32 | |
| — | 20.00 | — | — | ||
| Supply of Track Lead Junction Box (TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows:(a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc.(b) Each TLJB shall have two Bakelite terminal block fitted horizontally: each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB, nickel chrome plated brass links (two nos.0f adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe of size 32/35mm, 380 mm long alongwith two nuts for fixing on the TLJB hole.(d) The FRP stump for mounting the TLJB to be made of one-meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mm X30mmX 4mm angle (1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509.Inspection: (i) RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board.Inspection Charges: (i)Borne by Railways (ii) NonePayment Terms: 100% on Supply | — | — | — | 42,806 | |
| — | 8.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 1) or latest.Inspection: RDSOInspection Charges: Borne by Railways.Payment Terms: 100% after supply. | — | — | — | 39,464.56 | |
| — | 4.00 | — | — | ||
| Fixing and wiring of DC track circuit equipments i.e. track feed charger, resistance, track relay, battery, B type choke etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make terminals/ fuse blocks / HRC fuse. Item includes testing /commissioning of track circuit. Complete wiring material will be supplied by contractor.(Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays, ARA terminal/Modular terminals Wago/phoenix contact type will be supplied by Railways / covered in Schedule separately).Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after execution. | — | — | — | 30,588.2 | |
| — | 4.00 | — | — | ||
| Installation of DC track circuits covering all types of Track circuits including points zones also. The item includes provision of doubled continuity GI wire bonds on rail joints after drilling bond-hole of 7.0/7.2 mm Dia, skimming of fish plate, insertion of insulated block joint( if required), fixing of TLJB (separate for positive & negative rails) with angle iron for track feed/jumper/track relay ends of track circuits and also for fixing jumper cables as per approved Track Circuit Plan, making rail connections through suitable insulated sleeves from TLJB at TF, jumper & TR end with GI wire, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on TLJB terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of Hooks. In case Engineer at site desires that jumpering from TLJBs is to be done using signalling cable 2 core X 2.5 sq. mm, contractor shall provide the jumpering cable using 2 X 2.5 sq. mm signalling cable. The signalling cable will be supplied by Railways. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins, Hooks etc. The item does not include includes supply of TLJB as per RDSO Drg. No. RST-11509 or latest as per technical specs Installation of Track Lead Junction Box (TLJB) as per Drg.No.RST- 11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc.(a) Installation and commissioning of TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc.(b) Installation and commissioning of Each TLJB having two Bakelite terminal block fitted horizontally: each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB, nickel chrome plated brass links (two nos.0f adequate strength for vertical linking of the terminals to be wired and fixed properly.(c) Installation of HDPE pipe of size 32/35mm, 380 mm long along with two nuts for fixing on the TLJB hole.(d) Installation of the FRP stump for mounting the TLJB to be made of one-meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mm X30mmX 4mm angle (1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should be fixed in given holes on them for fixing using galvanised nuts and bolts.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after execution. | — | — | — | 38,285.28 | |
| — | 10.00 | — | — | ||
| Supply of Apparatus Case Single (Large) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500.Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys.Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board.(ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board.Inspection Charges:(i) Borne by Railways (ii) NonePayment Terms: 100% after Supply. | — | — | — | 1,79,869.4 | |
| — | 10.00 | — | — | ||
| Installation of Apparatus Cases Single (Large) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. | — | — | — | 12,505.4 | |
| — | 4.00 | — | — | ||
| Supply of Apparatus Case half (Medium) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11507.Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board.(ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board.Inspection Charges:(i) Borne by Railways (ii) NonePayment Terms: 100% after Supply. | — | — | — | 45,441.28 | |
| — | 4.00 | — | — | ||
| Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder, switch and lamp etc.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. | — | — | — | 3,046.24 | |
| — | 10.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. Single (Large) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | — | — | — | 82,908.1 | |
| — | 4.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. Half (Medium) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | — | — | — | 25,317.6 | |
| — | 7.00 | — | — | ||
| Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 12 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied.Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee Inspection Charges:(i) Borne by Railways (ii) NonePayment Terms: 100% after Supply. | — | — | — | 40,902.05 | |
| — | 10.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. Single Case (Large Case) | — | — | — | 28,215.9 | |
| — | 4.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. Half Case (Medium Case) | — | — | — | 3,292.76 | |
| — | 2000.00 | — | — | ||
| Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Supply of all above terminals have been covered separately in Chapter 4 of SOR)Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after installation. | — | — | — | 30,140 | |
| — | 10.00 | — | — | ||
| Supply of Rapid Joint LS3, suitable for cable Jointing of Signalling cable of various size, having dielectric strength > 20KV/mm, Non-Toxic, low viscosity, Flammability point > 200 C, Re-enterable, long storage life Make RAYTECH or Similar.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after Supply Cable Size 6C x 1.5 Sq. mm. | — | — | — | 42,200.6 | |
| — | 30.00 | — | — | ||
| Supply of Rapid Joint LS3, suitable for cable Jointing of Signalling cable of various size, having dielectric strength > 20KV/mm, Non-Toxic, low viscosity, Flammability point > 200 C, Re-enterable, long storage life Make RAYTECH or Similar.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after Supply Cable Size 12C x 1.5 Sq. mm. | — | — | — | 1,76,157.3 | |
| — | 10.00 | — | — | ||
| Supply of Rapid Joint LS3, suitable for cable Jointing of Signalling cable of various size, having dielectric strength > 20KV/mm, Non-Toxic, low viscosity, Flammability point > 200 C, Re-enterable, long storage life Make RAYTECH or Similar.Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after Supply Cable Size 30C x 1.5 Sq. mm. | — | — | — | 1,51,160.4 | |
| — | 200.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with coupling on culverts bridges as per Drg. No. CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends.Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Supply. | — | — | — | 1,83,090 | |
| — | 200.00 | — | — | ||
| Fixing of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 (Part 1): 2004 with coupling on culverts bridges as per Drg. No. CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work (if required) to protect the cables from sharp edges and sudden bends.Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after installation. | — | — | — | 45,774 | |
| — | 300.00 | — | — | ||
| Supplying and placing of one layer of standard size of 'B' grade quality bricks of the local make spreading on cables laid. (minimum size of brick 200mm X 100mm X 70mm)Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Installation. Length wise (up to 2 cables). | — | — | — | 5,343 | |
| — | 1200.00 | — | — | ||
| Supplying and placing of one layer of standard size of 'B' grade quality bricks of the local make spreading on cables laid. (minimum size of brick 200mm X 100mm X 70mm)Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Installation. Width wise (more than 2 cables) | — | — | — | 46,032 | |
| — | 30.00 | — | — | ||
| Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd.Inspection: RDSOInspection Charges: Borne by RailwaysPayment Terms: 100% after Supply | — | — | — | 77,580 | |
| — | 20.00 | — | — | ||
| Jointing of 4 / 6 quad /Signalling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost.Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution | — | — | — | 27,859.8 | |
| — | 300.00 | — | — | ||
| Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine) or by Closed trench Method. The bore shall be upto 200 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different Dia DWC-HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note: - Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution | — | — | — | 4,34,331 | |
| — | 500.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. (cum is Cubic Meter)Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution | — | — | — | 1,65,050 | |
| — | 24000.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution | — | — | — | 2,62,800 | |
| — | 4.00 | — | — | ||
| Supply of permanently Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 Amdt. 3 or latest. The item also includes supply of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs(ii) Consignee if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board.Inspection Charges: (i)Borne by Railways (ii) NonePayment Terms: 100% on Supply | — | — | — | 2,32,580.04 | |
| — | 4.00 | — | — | ||
| Laying of permanently Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 Amdt. 3 or latest. The item also includes installation of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution. | — | — | — | 58,145 | |
| — | 4.00 | — | — | ||
| Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer incharge at site.Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution. | — | — | — | 52,014.16 | |
| — | 8.00 | — | — | ||
| Construction of Brick Chamber/RCC of optical fibre cable straight through joint as per Drg. No. CSTE/NWR/ SOR/23. It also includes supply and provision of all the material required for this item like bricks, sand, cement etc. The cement and sand should be in ratio 1:6.Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution. | — | — | — | 50,680.56 | |
| — | 15.00 | — | — | ||
| — | — | — | 1,22,997.9 | ||
| — | 4.00 | — | — | ||
| — | — | — | 54,690.76 | ||
| — | 8.00 | — | — | ||
| — | — | — | 1,18,969.36 | ||
| — | 50.00 | — | — | ||
| — | — | — | 1,08,206.5 | ||
| — | 100.00 | Man-Days | — | ||
| — | — | — | 70,728 | ||
| — | 200.00 | — | — | ||
| Supply of GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. Inspection: ConsigneeInspection Charges: NonePayment Terms: 100% after Supply. | — | — | — | 15,888 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TelecomCircularNo.09_1.pdf
ATTACHMENT
MakeInIndiaPolicy2017.pdf
ATTACHMENT
GCC202210NosCorrectionSlipsofGCC_compressed.pdf GCC and 10 Nos Correction Slip
ATTACHMENT
GCCACS-11dated13.03.26_compressed.pdf
ATTACHMENT
GCC Corection Slip 12
ATTACHMENT
TenderDocofTenderNoSNT-JP-18-2026-27.pdf
ATTACHMENT
GCC202210NosCorrectionSlipsofGCC_compressed.pdf
ATTACHMENT
ACSNo12ofIndianRailwayStandardGCCApril-2022issuedon12-08-2026.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .