| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-Finance | L1 | Accepted-Finance 1st lowest | |
| 2 | L2₹47.0 L+₹1.6 L (3.50%)Accepted-Finance | L2 | Accepted-Finance 2nd lowest | |
| 3 | L3₹49.6 L+₹4.2 L (9.18%)Accepted-Finance | L3 | Accepted-Finance 3rd lowest | |
| 4 | L4₹50.5 L+₹5.1 L (11.2%)Accepted-Finance 124 JN ROAD DELANIPUR PORT BLAIR 744102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L4 | Accepted-Finance 4th lowest | |
| 5 | L5₹52.7 L+₹7.3 L (16.1%)Accepted-Finance | L5 | Accepted-Finance 5th lowest |
Tender Value
₹46.4 L
EMD Value
₹92,787
Closing Date
3 Jul 2020, 3:00 pmClosed
EE, PBSD, APWD, Port Blair
EE, PBSD, APWD, Port Blair
Repair and Maintenance of type_V Qtrs under AE_II, PBSD, APWD, Port Blair during 2018_19. SW_Repair and renovation of Type_ Quarter No. G_106 at Supply Line, Port Blair.
2020_APWD_267_1
01/EE/PBSD/2020-21
Open Tender
Civil Works - Buildings
Works
60 days
EE, PBSD, APWD, Port Blair
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Payable To EE, PBSD, APWD, Port Blair
₹92,787
3 Jul 2020
18 Jun 2020
3 Jul 2020
18 Jun 2020
3 Jul 2020
18 Jun 2020
18 Jun 2020 - 3 Jul 2020
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing and fixing bolts including nuts and washers complete.
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Asbestos sheet
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :
Up to 10 mm thick
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead :
Of sectional area 40 square centimetres and above
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
Of area 3 sq. metres and below
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Barge board (Upto 300 mm)
Gutter .(600 mm over all girth)
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
6 mm thick Cement fiber board as per IS: 14862
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in- charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm
For thickness of tiles above 25 mm and up to 40 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Superior Hard wood Cat-II(A).
Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding ,panelling which will be paid for separately all complete as per the direction of Engineer- in- charge.
Superior Hardwood Cat-II(A) 35mm thick shutters.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
Superior Hard Wood Cat-II (A) 35 mm thick
Providing and laying hollow cement concrete block walling upto floor five level 200mm thick consisting of hollow block of size 400x200x200mm of mix 1:3:6(1 :cement 3 :coarse sand 6 :graded stone aggregate 10mm nominal and down size) having a crushing strength of 3.5N/sqmm at 28 days as per IS:2185 (part-I) 1979 laid in cement mortar 1:6(1 :cement 6 :coarse sand) upto floor five level.
Providing and laying hollow cement concrete block walling upto floor five level 100mm thick consisting of hollow block of size 400x100x200mm of mix 1:3:6(1 :cement 3 :coarse sand 6 :graded stone aggregate 10mm nominal and down size) having a crushing strength of 3.5N/sqmm at 28 days as per IS:2185 (part-I) 1979 laid in cement mortar 1:6(1 :cement 6 :coarse sand) upto floor five level.
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
Superior Hard Wood Cat-II (A)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
One or more coats on old work
Finishing walls with Acrylic Smooth exterior paint of required shade:
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
15 mm to 40 mm nominal bore
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge
Extruded section profile size 48x40 mm
Providing and fixing to existing door frames.
25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK
25 mm nominal outer dia Pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing brass bib cock of approved quality :
15 mm nominal bore
Providing and fixing CP Brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour as per the direction by Engineer-in-charge. ( Code No. PM-902)
450 mm long towel rail
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
100 mm diameter
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing C.P Brass towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, as per the direction by Engineer-in-charge. ( Code No. DM-907)
Providing and fixing CP brass liquid soap container of standard shape with bracket of the same materials with snap fittings of approved quality and colour, as per the direction by Engineer-in-charge. ( Code No. PM-924)
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
100 mm inlet and 75 mm outlet
Sand cast iron S&S as per IS - 3989
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing brass stop cock of approved quality :
15 mm nominal bore
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink with drain board
510x1040 mm bowl depth 250 mm
Providing and fixing storage Kitchen cupboard /cabinet of 600 mm depth (front & back) made of Teak wood superior quality chemical treated edge glued fingers, jointed procesed as 150 specification & finished with two coats of sanding sealer, 2 coats of NC filler & PU/melamine polish of desired shade & cabinet providing shutter 24mm thick with all fittings like stanless steel kitchen basket, telescopic channel for draws, brass butt hinges, brass tower bolts, brass magnet catcher, locking arrangement as per the direction of Engineer-in-charge.
Renewing mosquito proof net of Galvanized wire mesh of average width of aperture 1.4 mm and nomiminal dia of wire 0.63 mm and refixing existing wooden fillets in door and window frame.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular tank
Providing and placing micro concrete alongwith chicken mesh including surface preparation to receive micro concrete by chipping to depth of maximum 75 mm, cleaning, removing the traces of dust, loose concrete etc including the cost of centring, shuttering formwork and all labour charges, minor tools etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Panelling the frames with fiber cement flat sheet of thickness 12 mm with necessary screws, bolts etc. Complete as directed by the Engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
ANAND TRADERS AND CONSTRUCTION
A Palani
Mega Engineers and Builders
M/S THAKUR TRADERS AND ENGINEERS
VINIT NAIDU
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .