| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC HIMACHAL PRADESH HP | KANGRA | HIMACHAL PRADESH | 176204 | ₹2.3 L | L1 | Accepted-AOC AOC |
| 2 | L2₹2.4 L+₹9,265.77 (4.04%)Rejected-Finance HPSEBL THALOUT | ₹2.4 L+₹9,265.77 (4.04%) | L2 | Rejected-Finance L2 |
| 3 | L3₹2.4 L+₹13,898.66 (6.06%)Rejected-Finance VILLAGE DALOG P O NARAIN TEHSIL RAMPUR BUSHAHR DISTT SHIMLA H P | SHIMLA | HIMACHAL PRADESH | 171001 | ₹2.4 L+₹13,898.66 (6.06%) | L3 | Rejected-Finance L3 |
Tender Value
₹2.3 L
EMD Value
₹2,316
Closing Date
10 Feb 2026, 9:00 amClosed
Resident Engineer
Resident Engineer, GPHD, Jeori
HPSEBL/GPHD/DB-9/2025-26-151
2026_HPSEB_127511_1
HPSEBL/GPHD/DB-9/2025-26-151
Open Tender
Civil Works
Percentage
60 days
Ganvi
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
₹2,316
27 Jun 2026
4 Feb 2026
11 Feb 2026
4 Feb 2026
10 Feb 2026
4 Feb 2026
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Group A
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying & fixing wooden boxes of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required:-203mm.x 254mm.x60mm. deep
Supplying & fixing wooden boxes of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required:-102mm.x102mm.x60mm. deep
Supplying & fixing wooden boxes of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required:-178mm.x102mm.x60mm. deep
Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required. S.P. 5/ 6 Amps one way switch, piano type.
Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required. S.P. 15/16 Amps one way switch, porcelain base/ piano type.
Bell push, piano type.
5 pin 5/ 6 Amps socket outlet, porcelain base/ piano type.
6 pin 15/16 Amps socket outlet, porcelain base/ piano type.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Single door-6 way
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Single pole. Cat-A.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Double pole. Cat-A.
Providing and fixing of following sizes of PVC casing and capping on surface as required:- (Rates of only ISI marked PVC casing/capping have been taken in the following items, unless and otherwise specified, only such casing/capping shall be used in the work) 20 mmx 12 mm
Providing and fixing of following sizes of PVC casing and capping on surface as required:- (Rates of only ISI marked PVC casing/capping have been taken in the following items, unless and otherwise specified, only such casing/capping shall be used in the work)25 mmx 15 mm
Wiring for circuit / sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x1.5 Sq. mm.
Wiring for circuit / sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x4.0 Sq. mm.
Wiring for circuit/sub-main with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 2 No.4 Sq.mm.(4x4+2x4) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_188313.xls
BOQ • 0.30 MB
151tender.pdf
Tender Documents • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .