Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹27.0 L+₹2.1 L (8.52%)Rejected-Finance | L2 | Rejected-Finance Being L2 bidder |
Tender Value
₹30.6 L
EMD Value
₹61,180
Closing Date
22 Oct 2022, 6:00 pmClosed
Shri Avinash Mishra IDSE EE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIFICATION AND EXTERNAL WATER SUPPLY DG SET COOLING APPLIANCES AND ALLIED WORKS
2022_MES_553878_1
8310/BBSR/05/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Bhubaneswar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (I) (CG) Bhubaneswar
₹61,180
Yes
17 Nov 2022
23 Sept 2022
24 Oct 2022
23 Sept 2022
22 Oct 2022
8 Oct 2022
23 Sept 2022 - 1 Oct 2022
Amount
EXTERNAL ELECTRIC SUPPLY Excavation in trenches in hard/dense soil n.exc 1.5m wide and n. exc 1.5m depth getting out of soil for taking out or laying of pipe line, laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm the cable prependicular to the direction of cable complete all as specified and as directed.
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as specified and as directed.
Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etccomplete all as specified and as directed.
Disconnecting, taking out old unserviceable LT UG Cable of size 3.5 / 4 Core 10 Sq mm to 150 Sq mm from trenches complete for remove including taking down protection cover or bricks , GI Pipe etc complete all as specified and as directed.
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 150 Sqmm 3.5 Core laid in trenches or fixed on wall/floor/poles complete with cable glands & lugs cable route indicator as required complete all as specified and as directed.
All as per item No. 8 here-in-before but 3.5 x120 sq mm cable
All as per item No. 8 here-in-before but 3.5 x95 sq mm cable
All as per item No. 8 here-in-before but 4 x 25 sq mm cable
All as per item No. 8 here-in-before but 4 x 16 sq mm cable
All as per item No. 8 here-in-before but 2 x 10 sq mm cable
Taking down carefully unserviceable LED Street lights/Security lightS&Flood lights fittings of any type and capacity from pole/ wall with dismantling the light fittings , checking its serviceability circuit board ,driver units,and carried out necessary repairs/soldering of worn out circuits /connections ,replacement of unserviceable parts and refixing the same after repair including connecting and testing the same complete all as specified and as directed. NOTE:- Replacement of old unserviceable spare parts shall be measured and paid separately under supply only items.
Supply only Driver unit suitable for LED street light fittings of 45 wattscomplete all as specified and as directed. Make- Crompton/Phillips/C&S
Supply only MCPCB unit suitable for LED street light fittings of 45 watts complete all as specified and as directed. Make- Crompton/Phillips/C&S
Supply and fixing in replacement of energy saving environmental friendly, long life LED Lexon Street light fitting 45 watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperete driver compartment with IP 66 protection complete all as specified and directed (Make :Cromton Cat Part No.LSTS-45-CDL or equivalent in Philips/ Havells)
Supply and fixing in replacement of LED Bollard blink light , robust design IP 65 ensuring excellent distribution and high system lumen efficacy suitable for 9 W LED complete with junction box with terminal of size 104x104x70 mm of make hensel cat part no-KF 0404 g or equivalent including suitable PCC foundation complete all as specified and as directed. Make Havells Cat part No-Crompton (LIARA) cat part no LBLSN-10-CDL or equivalent Havells, CG, wipro & Philips
Supply and fixing in replacement of energy saving environmental friendly, long life LED Lumos Max flood light fitting 180 watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperete driver compartment with IP 66 protection including taking down old unserviceable light fitting from high mast complete all as specified and directed. (Make :Surya Cat Part No.SLE FL 180W IP66LUMOS MAX or equivalent in Philips/ Havells)
Supply and fixing in repair of GI pipe Bracket of 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr including 2 no. MS Clamp of flat iron size 40x6 mm complete with nut, bolt, washers suitable for street light pole complete all as specified and as directed. (Make of GI pipe- Jindal/Prakash/Tata)
Supply & Fixing in repairs cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 205x255x112 mm and suitable for LT under ground cable any size/capacity including bracing clamp,bolts,nuts & washers complete all as specified and as directed. (Make Hensel/ model No-KF2525B or Sintex or equivalent as approved)
S & F in repair Street light timelite distribution boards timelite-32 A 3 pole/230 V Astronomical time switch complete all as specified and as directed. Make Indoasian Cat part no TL032ASO & equivalent
Dismantling and taking out old un-serviceable Non-integral light fittings from 13.5 mtr High mast tower with checking its connection and unserviceable parts ,such as Drivers,LED lamps ,LED Fittings etc and replace the same and refitting in its position including servicing the double drum winch and greasing the 5 mm dia steel wire rope, wheels,operating handles with all parts and equipments of existing High mast Tower ,fitting ,Allignment upto length, testing complete in all respect after the high mast tower mounted complete all as specified and as directed. Note: The Lights fittings to be replaced shall be measured seperately under this schedule of item.
M&L for replacement of Steel wire rope of size 5 mm dia ( as per existing) with required nuts,bolts and hooks including taking down old U/S steel wire rope from different high mast towers complete all as specified and as directed.
Supply& Fixing in replacement of MCB, SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA complete all as specified and as directed. ( Make Legrand,Cat No.6032 31,33-37 or Havells/Legrand ).
Supply & Fixing in replacement of MCB, SPN. 6-32 Amps rating 240, volt, 'C' series, 10 kA complete all as specified and as directed. (Make Legrand,Cat No.6032 48,50-54 or Havells/Legrand ).
S & F in replacement of MCB TPN 10 KA "C" series 415 Volt 63 Amps complete all as specified and directed. (Make Legrand,Cat No.6032 74 or Havells/Legrand/ Schneider/ ABB)
S&F in replacement MCCB 4 pole with fixed thermal & magnetic release of breaking capacity 36 kA, 415 Volts, 63 Amps complete all as specified and as directed. (Make: Legrand 4200 92 or Standard/Legrand/HPL//Havells)
Supply and fixing in replacement of MCCB 4 pole , 100 amp rating of 16 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and as directed.( Make : Legrand or equivalent in ABB/Schnieder)
Supply and fixing in replacement of MCCB 4 pole , 160 amp rating of 16 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and as directed. ( Make : Legrand or equivalent in ABB/Schnieder)
Supply and fixing in replacement of MCCB 4 pole ,200 amp rating of 16 KA adjustable type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and as directed.( Make : Legrand or equivalent in ABB/Schnieder)
Supply & Fixing , in replacement, PVC copper cable 3 core of size 1.5sq mm for junction box to street light fitting connection including PVC pipe complete all as specified and as directed. (Make: Finolex/ Polycab/ Plaza)
M & L for cable fault finding of any size at any location complete with rectification duly joined by suitable jointing kit above 25 Sqmm cable complete all as specified and as directed.
S&F for replacement of on load change over switch 3 phase 415 volt 50 Hz 200Amp to be fixed in existing panel complete all as specified and as directed. Make LT/Havells/Legrand/C&S
Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends or edges teps,cills,sunshades,shelves,lintels,etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size complete all as specified and as directed.
Supply and fixing of neon light (RYB) complete on existing LT panel board including dismantling and taking out of old items complete with connected wiring for Phase indication complete all as specified and as directed. ( Make : L & T or equivalent)
Supply and fixing of Amperemeter digital (0-100)Amp, along with CT's complete on existing LT panel board including dismantling and taking out of old items complete all as specified and as directed. ( Make : L & T or equivalent)
Supply and fixing Voltmeter digital type with of (0-440) Volt on existing LT panel board including dismantling and taking out itms complete with connected wiring for Phase indication complete all as specified and as directed. ( Make : Legrand or equivalent in ABB/Schnieder)
Supply and fixing in replacement of energy saving environmental friendly , long life ASTRA NEO LED Bldg security light fitting 25 watt made of pressure die cast housing with high power LED as lighting source and lens embedded PC cover having top opening seperete driver compartment with IP 66 protection complete with GI bracket & fixing arrangements including taking down old unserviceable light fitting complete all as specified and directed (Make :Cat Part No.LSTS-25-CLD-M of Crompton or equivalent in Bajaj/ Havells/ Philips)
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel wire 4mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. mild steel TMT bars @ 150 mm c/c both ways, and with onehandle for lifting made out of 10 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and taking down old unservicable earthing complete all as specified and directed.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 32×6mm by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. mild steel TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and taking down old unservicable earthing complete all as specified and directed.
M&L for demolition of PCC of any description and in any position for cement concrete(unreinforced) complete all as specified and directed
M&L for providing cement concrete in foundation/coping of poles type B0 1:2:4 ( 12.5 mm graded aggregate) all as specified and directed t hangar area and secure the pole in correct position complete with finishing complete all as specified and as directed.
M & L for Repair of air break gang operated switches vertical/horizontal type such as repair/ replacement of broken/worn out components & insulators and greasing the moveble parts ( Male/female parts) for smoth functioning complete all as specified and as directed.
Supply and fixing in replacement of air break Gang operating Drop Out (GODO) switch vertical / horizontal typeTriple pole, mechanically operated, mounted on 12 insulators and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps suitable for 11 KV complete with testing complete all as specified and as directed.
Supply and fixing of cable trench cover made out of 6/7 mm thick steel chequered plate including arrangement of two Nos lifting & droping handle as per sample in replacement of broken concreat cover complete all as specified and as directed.
Supply and fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor/Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Supply and fixing in replacement of Cable jointing kit for LT 1.1 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Supply and fixing of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and as directed.
M & L for metal spreading around the two pole structure including cleaning & removing grass of the area 4mx3m approx around the two pole structure. Spreading & leveling sand cushioning 15 mm over the cleaning surface and spreading 40mm graded aggregate over the sand cushioning, paint the concrete surface with lime paint complete all as specified and as directed.
M&L for complete routine test of transformer of Cap upto 315 KVA (as per IE rules) with authorised agency as per the direction of Engr-in-Charge and submit the all routine test certificate by the authorised agency to Engr-in-Charge for maint of our record of any capacity of trnasformer complete all as specified and as directed.
Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up complete all as specified and as directed.
M & L for painting of two pole structure with aluminium paint after removing old paint from pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint complete all as specified and as directed.
Supply & fixing in replacement of breather Assembly for upto 315 KVA Transformer complete all as specified and as directed. Make : MB Supplier/Pooja industries/Goyal electric works.
S & F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for upto 315 KVA Transformer complete all as specified and as directed.
M&L for Filtration and Dehydration of transformer oil of Transformers at different location of CGRA/CGAE with filtration cum dehydration machine to achieve desired level of di electric strength of transformer oil including testing complete all as specified and as directed. Note- The quoted rate shall deem to incl for the cost of centrifuging the transformer oil by means of electrical operated centrifuging machine . (ii) The contrator shall test the di electric strength of oil of each transformer before dehydration & filtration and after completion of dehydration and filtration process he shall submit record of the same. Each sample of oil shall be tested with a transformer oil test machine at site in presence of concerned JE/ Engr- in- Charge. The contractor will have to arrange correctly calibrated Transformer Oil Test machine. for this purpose. (iii) The dielectric strength should not be less than 45 KV.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
S&F in replacrment of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11KV greasing the moveble parts ( Male female parts) for smoth functioning complete all as spcified and directed.
M & L for painting of Street light pole with aluminium paint after removing old paint from steel pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint complete with numbering of pole complete all as specified and as directed.
EXTERNAL WATER SUPPLY M & L for Cleaning ,servicing ,painting ,writing SM.MES No of pump sets including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing etc for smooth running and replacement of gland packing, gaskets, shaft sleeve, gland packing, neck ringnut bolts and washers etc, with necessary oiling and greassing of 15 HP & 20 HP pump complete all as specified and as directed. Note: The rate included for grinding of shafts, replacement of all parts for required to working of Pump sets in all respect. Bearing will be measured & paid seperately as supply only under this schedule.
Supply only ball bearing 6310-ZZ/C3(SKF) & bearing 6206-ZZ (SKF) for pump complete all as specified and as directed.
Dismantling and taking down of motor from pump after disconnection of mechanical tyre coupling and unbolting from foundation base plate,disconnecting of electric connection from terminal, loading/unloading the motor to vehicle and transportation of the motor to workshop, cutting the burnt winding and clean the rotor & stator with CTC or other cleaning matarial and rewinding of stator/ rotor winding with supper enamaled copper wire as per existing the size/gauge wire and turn of the previous winding, insulating the leads with insulating tubes and varnishing the stator with good quality of insulating varnish . Afterward heating the stator in heat chamber for continous 2 days for better insulation resistance reassembling the stator & rotor carefully after replacement of worn out bearings, transportation of motor from workshop to its original location, unloading the motor and placing it on base frame, connection of motor with pump with tyre coupling and fixing to the base frame after checking up the alignment, testing of motor with megger for checking of insulation resistances, electric connection of motor to the control panel, testing on load of capacity 15 /20HP Induction motor complete all as specified and directed.
M&L for repair, cleaning and servicing of automatic star delta starter of capacity 15/20 HP fixed in existing LT panel including tightening of all loose coonection and replacement of minor defective parts such as cable lugs, nut bolts PVC copper connection wire etc to make the starter serviceable complete all as specified and as directed. (Note : Major defective parts will be measured and paid seperetely under relevent item as supply only)
M & L for Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing etc for smooth running and replacement of packing gaskets, shaft sleeve, gland packing, neck ringnut bolts and washers etc, with necessary oiling and greassing of 7.5 HP pump complete nd with testing all as specified and directed by Engr-in-Charge. Note: The rate included for grinding of shafts, replacement of all parts for required to working of Pump sets complete all as specified and as directed. Note : Bearing will be measured & paid seperately as supply only under this schedule.
M & L in replacement of gland packing of any size suiatble for existing pump complete all as specified and as directed.
M&L for repair, cleaning and servicing of automatic star delta starter of capacity 7.5 HP fixed in existing LT panel including tightening of all loose coonection and replacement of minor defective parts such as cable lugs, nut bolts PVC copper connection wire etc to make the starter serviceable complete all as specified and as directed.
M & L for Cleaning and removing all scales and deposited materials in under ground water sump of 2.5 lakhs ltr by drain out the sludge/waste at bottom of the tank by manually or using non cloging pump sets and applying bleaching powder , brushes for removing deposited materials and removal the same from sump and deposited the same where as directed (not more than 50 mtr) , including cleaning the sourrounding area of under ground sump complete all as specified and as directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud utside the premises shall be deemed to include in the above item rate.
All as per item No 67 above but capacity of UG Sump 3 lakhs litre.
M & L for Cleaning and removing all scales and deposited materials in over head tank 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified and as directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud utside the premises shall be deemed to include in the above item rate.
Supply only Calcium Hypochlorite granules 65% to 70% with CIAS (ALTOCH-GP) for potable water in 45 kg drum complete all as specified and as directed.
Taking up/down GI tubing from trenches , duct, wall, roof or in any position with all fittings for re-laying /refixing of serviceable pipes and removing the unserviceable pipes for 40mm to 50 mm dia complete all as specified and as directed.
All as per item No. 71 here-in-before but 25 mm dia
Supply and fixing of GI tubing medium grade of 50 mm dia for cable protection on pole/wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc complete all as specified and as directed.
All as per item No. 73 here-in-before but 25 mm dia
Supply and fixing in replacement of brass gun metal gate valve with iron wheel head screwed both ends for iron pipes including taking out old unserviceable valves for 50 mm dia pipe complete all as specified and as directed.
Supply and fixing of MS tubing medium grade of 100 mm dia with all fitting including welding and fixed complete to walls and ceilings or laid in floors along with suitable supports and flanges suitable for fixing at pump suction all as specified including two coats of primer and one coat of synthetic paint complete all as specified and as directed.
Supply and fix in repair foot valve as per IS-4038 of cast iron with brass diaphragm heavy duty screwing type complete all as specified and as directed of the following sizes .Make-Kirloskar/Kartar/Leader/Upadhaya
100 mm dia bore pipe
80 mm dia bore pipe
Supply and fixing of brass gun metal gate valve with iron wheel head screwed both ends for iron pipes including taking out old unserviceable valves for 50 mm dia pipe complete all as specified and as directed.
All as per item No.79 here-in-before but 25 mm dia
M & L in replacement of CI non return butterfly valve suitable for 80 mm dia pipe with complete accerssories complete all as specified and as directed.
Supply and fix in repair CI sluice valve flanged of class PN 1.6 conforming to IS - 14846 complete with iron wheel head , SS spindle and check nut , including jointing material such as rubber insertion nuts, bolts and washers etc complete ,of 80mm size complete all as specified and as directed. Make - Kirloskar/upadhaya/Leader/ Zoloto or eqvlnt.
M&L in replacement of Ball brass valves, high pressure, with polythene float and flynut complete, screwed for 40 mm dia iron pipe or brass ferrule and fixed complete accerssories complete all as specified and as directed.
M&L in replacement of Ball brass valves, high pressure, with polythene float and flynut complete, screwed for 50 mm dia iron pipe or brass ferrule and fixed complete accerssories complete all as specified and as directed.
All as per item No. 84 here-in-before but 25 mm dia
DG SET M & L for Servicing of DG set through authorised agency "B" check in replacement of fuel filter, primary and secondary, superbypass filter,oil filter. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling new engine oil complete all as specified and as directed for the following cpacity (a) :- Capacity 200 KVA, 125KVA & 82.5 KVA Note:- (a) Engine oil will be measured and paid separately as supply only under respective items of schedule 'A'. (b) Air filter will be replaced in each servicing of DG Set as supply only under respective items of schedule 'A'.
Supply only engine oil suitable for diesel generator set (Oil 15W/40) complete all as specified and as directed. Make: Servo/ HP / Bharat Petroleum.
Supply only coolant suitable for radiater of DG sets complete all as specified and as directed. Make: HP/TVS or Equivalent.
S&F in replacement of battery terminal brass(heavy duty)with nuts & bolts for battery (as per sample) complete all as specified and as directed.
Supply only Air filter and air pre filter to DG set of following capacities complete all as specified and as directed : - (a ) Capacity of 82.5 KVA , 125 KVA & 200 KVA
Supply only diesel filter to DG set of following capacities complete all as specified and as directed:- (a ) Capacity of 82.5 KVA , 125 KVA & 200 KVA
Supply only Oil filter set (Lube oil filter+ O ring & by pass Lube oil filter+ O ring) complete all as specified and as directed:- (a ) Capacity of 82.5 KVA , 125 KVA & 200 KVA
M&L for repair of radiator including dismantling the radiator from DG set of any capacity after removing hose pipe connection, nut, bolts etc and taking out the same to civil workshop for repair and descaling of radiator using descaling chemical etc as approved to remove mud/deposit on fins and/in copper tubes including bracing of copper tubes for arresting of leakage and re-fixing after replacement of unserviceable hose pipes and clamps complete with testing for DG Capacity of 82.5 KVA complete all as specified and as directed.
M & L for repair of Self starter of 12/24 Volts by replacing unserviceable pinion/ armature/Field Coil/Bushes/Bearing/Rivits etc all as required for smooth Functioning including testing and commissioning complete all as specified and directed.
M & L for repair of Dynamo of 12/24 Volts by replacing unserviceable Groove wheel/ armature including testing and commissioning complete all as specified and directed.
M&L for dismantling and taking out fuel injection pump for servicing from DG set of any type/make and capacity uptp 200 KVA disconnection of fuel injector line, carrying complete overhauling/ servicing of injector pump, ,calibration of fuel pump as per manufacturer instruction , assembling the same with DG set properly in original postion, checking the allignment , making proper fuel connection and testing for smooth opreation complete all as specified and as directed.
Supply & fixing in replacement of old unservicable feed pump for fuel injection pump complete assy for DG upto 200 KVA complete all as specified and as directed.
M& L in repair opening / taking out of injector of DG set of any type/make and capacity upto 200 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreatio complete all as specified and as directed.
Supply and fixing, in replacement, Radiator cap suitable for DG Set of any type / make and capacity, complete all as specified and as directed.
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed.
Supply and fixing, in replacement of Old unserviceable RPM CABLE of any size and length of existing complete all as specified and as directed.
S & F in repair DG set Controller of capacity upto 200 KVA for automation operation of DG set compelete with connected acessories complete all as specified and as directed.
Supply and fixing, in replacement, of Electronic Automatic Voltage Regulator (AVR) suitable for DG Set of upto 200 KVA capacity, with and including taking out old AVR and making all connection, testing for smooth operation complete all as specified and as directed.
Material & labour for carrying out complete overhauling / servicing of DG set panel/ control panel, including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as specified and as directed.
M & L for servicing of Governor of Dg set of capacity 82.5 KVA complete with made functional including change of spare parts if required complete all as specified and as directed.
M & L for servicing of Water pump of Dg set of any capacity upto 200 KVA complete with made functional including change of spare parts if required complete all as specified and as directed.
M&L for Reapirs to DG set door by welding and Brazing complete with locking arrangements complete all as specified and as directed.
Supply and fix DG set diesel tank cap with locking arrangements complete as per existing complete all as specified and as directed.
S&F in replacement of automatic battery charger of 24 Volt 10 A complete all as specifed and directed.
M&L for Servcing of DG set battery of 180 AH 12 V capacity by replacing distelled water and checking of specific gravity complete all as speicifed and directed
COOLING APPLIANCES Dismantling of Split type Air Conditioner, Refrigerator, water coolers of any capacity & 'make', opening up for servicing, inspection / examination for serviceability of compressor, fan, motor, relays,PCB of indoor and outdoor units, capacitors, cleaning the evaporator and condenser with compressed air/ water as required, lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips, unserviceable wiring, rubber mounting for compressor including all minor spare parts for carrying out servicing including reassembling & testing of AC, Refrigerator & water cooler complete all as specified and as directed.
Supply and charging refrigerant gas R-410 up to required level including cleaning the capillary and air filter evaprator condenser, including testing of leakage or pressure test suitable for 1.5/2 ton split AC complete all as specified and as directed.
Supply and fixing in replacement of hermetically sealed compressor unit of 2 Ton capacity split type AC including replacement of copper tube , capillary strainer etc and testing after completion of work complete all as specified and as directed. ( Kirloskar/LG/Hitachi)
Supply only in replacement the following capacity of starting/running capacitor suitable for 1.5/2 Ton split type AC complete all as specified and as directed. ( Epcos/Siemens)
Capacity of 10/20 MFD
Capacity of 36 MFD
Supply and fixing in replacement of starting relay complete with knob of compatable size for 2 Ton capacity split type AC complete all as specified and as directed.
Supply & fixing in replacement of thermostat suitable for 1.5 /2Ton capacity split type AC complete all as specified and as directed.
Supply and fixing in replacement of synthetic thermal insulation pipe with binding tape of 3/8" dia suitable for suction copper pipe of Split type AC complete all as directed including taking out old deterioted pipe and burried in ground complete all as specified and as directed.
All as per item No 117 above but of dia 5/8" suitable for discharge/liquid line of Split type AC
Supply and fixing in replacement of condenser unit of made out of copper tube and aluminium fins suitable for 2 Ton split type AC as per existing including making of all connection complete all as specified and as directed.
Supply and fixing in replacement of cooling coil evorporator unit complete made out of copper tube suitable for 2 Ton split type AC as per existing including making of all connection complete all as specified and as directed.
Supply and replacement of blower motor of indoor unit of split AC with new blower motor of split type AC of any make and capacity including taking down old one complete all as specified and as directed. Make: GE/Crompton Greaves or equivalent as approved)
Supply and replacement of Fan motor of condensing Unit of STAC with new motor suitable for STAC of upto 2.0 TR capacity including taking down old one complete all as specified and as directed. (Make: GE/Crompton Greaves or equivalent as approved)
Supply and replacement of compressor for water cooler upto 40/80 Ltr capacity and assembling and testing the compressor unit complete including taking down complete all as specified and as directed.
Supply & fixing and replacement of PTMT float valve of 15mm size suitable for water cooler of cap 40/80 ltr/hr, 60/120 ltrs/hr and 80/150 ltrs/hr capacity including taking down old float valve complete all as specified and as directed.
Supply and replace push type water tap made of stainless steel chrome plated suitable for 40/80 Ltr capacity water cooler as per existing including taking down complete all as specified and as directed.
Supply & fixing in replacement of Water cooler tray of existing size complete with fixing arrangement complete all as specified and as directed.
Supply & fixing of elect cable of size 2.5 sqmm 3-core FRLS copper conductor circular type with taking down of old unserviceable incoming cables of STAC complete all as specified and as directed.
S&F PVC Drain pipe of dia 3/4" suitable for Split type AC including taking down old deterioted pipe and burried in ground complete all as specified and as directed.
S&F Non-return valve with dead cap suitable for 1/4" dia charging pipe.including taking down old valve complete all as specified and as directed.
Taking down old Unserviceable Printed circuit board (PCB) with display board,sensor and remote control including all connected accessories of Indoor Units of Split type AC of any make and capacity of 1.5 TR/2.0 TR and send to reputed / authorised Company Workshop for necessary repairs with replacement of Spares for functionable and refix the same in its own position and testing all as per existing type and make complete all as specified and as directed. (Make of existing AC : LG / Hitachi). NOTE :- The Cost of Transportation and Spare parts used in repair are deemed to be included in Unit rates.
Shifting of Split AC of any size from its original location to new location with all piping and electrical wire including servicing to working condition and makes good as existing complete all as specified and as directed.
Dismantling the voltage stabilizer of any capacity ( 1 to 5 KVA) and make, opening up for inspection/checking serviceability of voltage regulating transformer relays, circuit board, voltmeters, incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as specified and as directed. Note. Replacement of spare parts shall be measured and paid separately under items below :-
Supply only transformer of any capacity between 4 to 5 KVA including taking down complete all as specified and as directed.
Supply and fixing in repair sheet metal encloser box including Plug and socket with 20 Amps MCB (SP) with taking down old U/S existing sheetmetal enclosure complete all as specified and as directed. ( Make- L&T/Legrand /Standard).
MCC MECHANICAL AND ENGINEERING CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .