Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
30 Jul 2022, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ Chief Engineer Delhi Zone Delhi Cantt-10
SPL REPAIR TO T-72 AND T-73 (POLICLINIC) AT BASE HOSPITAL UNDER GEEM BASE HOSPITAL DELHI CANTT-10
2022_MES_508448_2
CEDZ / TOKEN-09 OF 2022
Open Tender
Civil Works
Item Rate
210 days
Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹2,000
GE E/M BASE HOSPITAL
₹2.9 L
Yes
13 Feb 2023
17 May 2022
1 Aug 2022
17 May 2022
30 Jul 2022
16 Jul 2022
Amount
SCH A SECTION-I (B/R PORTION)
Taking down wooden roof trusses coupled rafter or trussed beam etc at any height from ground level having span upto 12 mtr and post rafter, purlin etc in any section in any position complete all as specified and as directed by Engineer-in-Charge. Note :- The bidders are advised to visit at site to ascertain the qty and quality of timber to be retreived in view of credit schedule before quoting their rates
Dismantling post&struts (wood, steel, RCC) any section including taking out embeded portion and making good disturbed ground post embeded in concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-2 ( using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed.
S&F Steel work as in tubular trusses, purlins, rafter, vertical post and similar works including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS- 1161-1979 gde SI-240 including Anti rust corrosion primer incl prepartion of surface at contractor workshop before fabrication complete all as specified and shown on Drg No. CEDZ/ST-2678 Sheet 1/1 dated 27 Nov 2019.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specifed & directed.
M&L for plates(plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc complete all as specifed and as directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces width or girth exc 10cm including preperation of surfaces complete all as specified and as directed.
M & L for applying one coat of synthetic enamel paint to old steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of old steel surfaces complete all as specified and as directed.
Dismantling of Asbestos cement corrugated/semi-corrugated sheets in roof coverings incl ridges etc at any height complete all as specified and as directed.
Supply & fixing Pre-painted galavalume alumininum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa (having weight not less than 4.35Kg/Sqm) as in roof covering fixed with cadmium plated tapping screws of suitable size complete all as specified and as directed by Engineer in charge.
Supply & fixing Pre-painted galavalume alumininum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa (having not less than 4.35Kg/Sqm) as in roof covering, ridge and valley gutter etc fixed with Cadmium plated tapping screws of suitable size complete all as specified and as directed by Engineer in charge.
S&F of 2 mm thick fibre glass reinforced translucent corrugated printed sheeting with two corrugations , side lap fixed with coatch screw and washer in roof, wall etc complete all as specified and as directed.
Dismantling of wall and ceiling board including frame GI/ Aluminium (fibre, pulp, insulation etc) or insulation boards/slab of any thickness and any description incl cover fillets complete all as specified and as directed.
M&L for GI anodised snap grid ceiling made of tee and angle section of size 24.5 x 24.5 x 1.50 mm thick, size of grid 605x605 mm with GI suspended wire of dia 2 to 3 mm fixed with wooden/ steel truss/ rafter including necessary fitting / fixture complete all as specified & as directed by Engineer in Charge.
S&F 12 mm thick BioGuard @ plain RH-95 medium density fire retardant mineral fiber ceiling board of size 605 mm x 605 mm and fixed in ceiling at any height etc complete all as specified and as directed.
Demolition of Mud in roofs, any thickness, including PCC/plastering and leeping plaster complete and removing the spoil to a distance exc 250 m but n exc 500 m complete all as specifed & as directed.
M&L for providing plain cement concrete, type B-0, 1:2:4 (using 12.5 mm graded stone agg) as in kerbs or mud stops rounded or chamfered on edges or roof padding, Gola, etc including cleaning the surface by wire brushing complete all as specified and directed.
M&L for 20 mm thick rendering on concrete surface of roof with cement mortar 1:4 is to be finished even and smooth(without using extra lime or cement) and including mixing of water proofing compound as per manufacturers instruction complete all as specified and directed. (Note : Water proofing compound shall be measured and paid separately)
Supply only water proofing compound (powder) of standard make as approved by GE complete all as specifed & directed.
M&L for roof treatment with APP modified water proofing menbrance as per the description below:- (a) Cleaning the new plastered surfaced and applying a coat of bitumen primer @ 0.3 Ltr /Sqm (confirming to IS-3384) on prepared surface. After drying of primer apply a coat of hot blown 85/25 grade bitumen confirming to (IS-702) @ 1.20kg/ Sqm (b) Laying APP (Atatic polypropyline) modified five layered membrance 3mm thick and weighing not less than 3.5 kg/Sqm with center core 160 GSM/Sqm :- core reinforced and laid with 100mm side overlap and 150 mm end lap. The memberenace shall be laid with LPG torch application overlaps shall be sealed and finished neatly as per manufacuturars instructions. (c) Finishing the top surface of membrance by applying a coat of silver aluminium paint complete all as per specified and directed.
Demolition of stone slabs laid bedded and pointed in any mortar and cladding tiles of any description or thickness in floors, aprons, walls, etc and removing the debris out off MOD land complete all as specified and as directed.
M&L for 17 to 20 mm thick machine cut kota stone flooring laid over and including screed bed or bedding layer mortar 15mm thick in cement mortar 1:4 for laying floor finished jointed and pointed with grey cement slurry mixed with pigments to match the shade incl all grade rubbing and polishing upto mirror (polishing) image complete all as specified and as directed.
All as per item No.24 (here-in-before) on skirting/dado over and including 10 mm thick rendering coat in cement mortar 1:3 complete all as specified and as directed.
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in floors, steps, cooking platforms and like over and including 15 mm thick in cement screed mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of other than white and black including moulding, etc complete all as specified and as directed.
M&L Granite (of any type)18 to 20mm thick work (table rubbed and polished) in floors,steps, jambs, pillars, window-cills,cooking platforms including 20mm thick screed bed or bedding in CM 1:6 for laying floor finishes complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) from, serviceble tiles to store and including disposal of all debris removed in MOD land complete all as specified and as directed.
M&L for Vitrified Ceramic tiles digital coloured double charged 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of cement mortar 1:4 complete all as specified and as directed.
M&L for 7mm to 8mm thick ceramic non skid tiles coloured of area exc 0.11 Sqm but nexc 0.18 Sqm (400x400mm) in flooring set and jointed in neat cement slurry and pointed in coloured cement to match with tiles laid over and including 15mm thick cement screed (1:4) complete all as specified and as directed
M&L for digital coloured glazed ceramic tiles of 450 x300mm, 7mm thick in vertical surfaces (including designed borders ) such size skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match over and including rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and as directed. Note:- (Rate of Designer border in vertical surface will deemed to be included into quoted rates)
Demolition of brick work built in cement mortar including all quoins, arches, pilllars etc. and precast articles including disposal of demolished material complete all as specified and as directed.
M/L for brick work with sub class 'B' bricks straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius as in half brick thick walls built in CM 1:4 complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc. including raking out of joints, hacking for key scrubbing down with water etc. any description complete all as specified and as directed.
M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick or concrete, new surfaces of walls finished the surface fair and even without using extra cement complete all as specified and as directed.
M&L rendering 15mm thick in cement mortar 1:6 on other than fair faces of brick surfaces of walls finished the surface fair and even without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying 3 mm thick wall care putty and making the surface even and smooth by rubbbing the surface and applying two coats of Anti bacterial Oil Bound Distemper complete all as specified and as directed.
M & L preparation of new surfaces of walls plastered or unplastered and applying two coats of cement base paint over a coat of primer to walls to obtain uniform surfaces including making good the surface complete all as specifed & directed.
M & L for complete removal of existing treatment from old decorated wall surface by scrapping by electrically operated grinder machine and applying priming coat of chalk whiting followed by two coats of Anti bacterial Oil bound distemper of any tint on walls complete all as specified and as directed.
M & L for complete removal of existing treatment from old decorated wall surface scrapping by electrically operated grinder machine from old decorated wall surface by scrapping and filling all patches with cement wall putty and applying one or more coat of Cement based paint on patches to bring the whole surface uniform and applying two coat of Cement based paint on walls complete all as specified and as directed.
M&L for complete removal of existing treatment from old decorated ceiling surface by scrapping / washing and applying 3 mm thick cement wall care putty and making the surface smooth by rubbing the surface and applying two coats of Oil bound distemper complete all as specified and as directed.
Taking down aluminium door/window chowkat or frame with shutter incl all fittings exc 1.5 sqm but not exc 4 sqm each complete all as specified and as directed
Taking down alluminium window/ventilators chowkat or frame with shutter incl all fittings not exc 1.5 sqm complete all as specified and as directed
Taking down old allmn partition, any description fixed in any position complete all as specified and as directed
Taking down wooden chowkhats or frames with shutters (without taking off shutter from the frames) n exc. 1.5 sqm each complete all as specified and as directed.
Taking down wooden chowkats or frames with shutters (without taking off shutter from the frames) exc. 1.5 sqm but n exc 4.00 each complete all as specified and as directed.
S & F powder coated aluminium anodised section 40 x 44mm x14 gauge for aluminium partition wall in wall in panel 1m x1m covered with 5mm thick plain/frosted tinted glass on top half portion and 12mm thick pre-laminated sheet fixed in half bottom portion complete all as specfied and as directed.
Re fixing old existng powder coated aluminium anodised section 40 x 44mm x14 gauge for aluminium partition wall in wall in panel 1m x1m covered with 5mm thick plain/frosted tinted glass on top half portion and 12mm thick pre-laminated sheet fixed in half bottom portion complete all as specfied and as directed.
S&F aluminium powder coated door frame with partially glazed shutters single/ double leaf divided into two glazed panels including aluminium anodised snap beading and rubber gasket/lining for fixing of glass as directed. The frame shall be fixed with aluminium anodised bolt by drilling in the existing wall and with thrust bolt of suitable size all as directed. The frame and shutter will be made out of the following section and fitting a) Aluminium anodised door frame 101.60 mm x 44.75 mmx2mm fixed with aluminium thrust bolt in walls by drilling as directed. b) Aluminium anodised sides rail of shutter section 83.5mmx 44.5mm x 2mm c) Aluminium anodised bottom rail of shutter section 150mm x 44.5 mm x2mm. d) Aluminium anodised top and middle rail of shutter section 100mm x 44.5 mm x 2mm. e) Aluminium anodised tower bolt 200 mm long - 02 Nos in each leaf of Make Classic/Argent as approved. f) Aluminium anodised handle 250 mm long of approved Make Classic/Argent 02. No’s in each leaf. h) Glass Pane shall be 5.5 mm thick tinted glass. j) 12mm thick prelaminated particle board laminated both side exterior grade and lock including complete all as specified and directed
Supply, fabricating and fixing frame and windows of aluminium powder coated of extruded aluminium section three track with S.S mesh with two sliding shutters with following sections : (a) Frame section shall be 63.50 mmx38.10 mmx2 mm thick. (b) Two track bottom rail for sliding of shutters 61.85mm x 31.75mmx2mm thick. (c) Two track top section shall be 61.85mmx31.75mmx2mm thick(d) for sliding shutter handle& 'H' bottom section should be 40mmx(18mm+9)mmx1.45mm thick(e) sliding shutter to be provided with 5.5mm thick sheet glass( Modi/Saint gobain/tinted, plain, frosted (f) stainless steel wire clothes 0.36mm nominal dia of wire and average width of aperature 1.40mm complete all as specified and as directed
M&L for powder coated aluminium frame ventilator shutters, fix type with or without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, 4 to 5mm thick glass panes,rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays/lock, Rollers, hinges type B-21 100mm long (2 no.) suitable handle (1 no per shutter) complete all as specified and as directed.
S&F solid PVC moulded door frame of size, 50x47mm, made out of 5mm thick wood grain colour PVC sheet, reinforced with MS square tube fixed with screw/plugs to brick walls complete all as specified and as directed.
S&F Factory made solid panel PVC moulded door shutter 28 to 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails,MS frame shall be covered with heat moulded wood grain colour PVC 'C' chanel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles &rails eith suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing incl complete all as specified and directed.
S&F stainless steel Butt hinges medium weight cold rolled of size 100mm complete all as specified and directed.
S&F 150 mm size aluminium power coated handles, fabricated type, anodised complete all as directed
S&F 200 mm size aluminium power coated anodised tower bolts of extruded section complete all as specified and directed.
Taking down/Dismantling eaves gutter, rainwater pipes and CI soil,PVC (any type) including all fittings heads,shoes,bends,swan necks etc including cleaning or refixing or removal to store.
S&F 100 mm dia CI spun pipe, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with stack clamps or laid in floors incl taking down old one complete all as specified and directed.
S&F 75 mm dia CI spun pipe, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with stack clamps or laid in trenches or in floors including taking down old one complete all as specified and directed.
S&F 100 mm dia cast iron floor trap including joints, etc complete all as specified and directed.
S&F 100 mm dia cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F 100 mm dia cast iron pipes branch pieces,single (equal or unequal) Tee, sockets, etc with oval access door if required and fitted with stack clamps, etc complete all as specified and directed.
Supply and fixing in repair vitreous China squatting pan, "Orissa" pattern size 580 X 440 mm, white, (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc complete all as specified and as directed.
S & F in repairs Vitreous China wash down water closet pan (pedstal pattern) white (squatting pan & trap including connection to drain or out going pipe and to flushing pipe anti syphonic pipe etc) complete all as specified and directed.
S & F in repairs plastic water closet seat , black/white, closed pattern with flat bottom & cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S & F in repairs 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve, float, chain and pull and brackets etc complete all as specified and as directed.
S&F in repair 15 mm bore Bib taps fancy type chromium plated half turn, screwed down,screwed for iron pipe or brass ferrule fixed complete all as specified and directed.
S&F in repair 15 mm bore stop/angle valve valves fancy type chromium plated screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or unions fixed complete all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. .
Dismantling of water tanks exc 250 ltrs & n. exc 500 ltrs capacity and removing to store complete all as specified and as directed.
Dismantling of water tanks exc 500 ltrs & n. exc 1000 ltrs capacity and removing to store complete all as specified and as directed.
Disconnecting existing water tanks setting aside for repairs and cleaning of tank capacity exc 250 ltr but not exc 500 ltr complete all as specified and directed.
S & F PVC water storage tanks of 500 ltrs capacity rotational moulded (multi layered cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F 1000 Ltr cap Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part-I and as directed by Engineer-in-Charge.
Fixing only PVC water storage tanks of 500 ltrs capacity rotational moulded (multi layered cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S & F in repair ball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of 20mm dia complete all as specified and directed.
S & F ball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of 20mm dia complete all as specified and as directed.
Taking up or down 15 mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Supply and laying of 20mm CPVC pipes SDR 11 and plain CPVC SDR 11 fitting on walls/ceiling or laying in floors complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning or refixing or removal to store complete all as specified and as directed.
S&F 20 mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches complete all as specified and as directed. .
Refixing 20 mm bore old steel tubing and conncetions in new or old position to walls complete all as specified and as directed. Note :- Old water tubing as obtained shall be reused after proper cleaning.
S&Fin repair vitreous china wash hand basin white flat back of size 550mmx400 mm including cutting for and pinning in end of brackets,,incl 32 mm waste fittings ,brass chromium plated for glazed ware sinks,basins etc,15 mm bore CP fancy type piller tap with long screwed shanks and fly nuts flange end bedded in cement and other end fixed.and waste pipe of polytethylene of low or high density or PVC 32 mm dia complete all as specified and directed.
S&F in repair vitreous china urinals, Half stall type (back or corner wall type),including polytethylene of low or high density or PVC 32 mm dia etc with 60mm long screwed pointing around urinal back in cement complete all as specified and directed.
S&F in repair stainless steel chromium plated of 19mm dia rod toilet paper holder compete all as specified and directed.
S&F in repair brass chromium plated soap dish compete all as specified and directed. (make pryag, jaquar or equivalant)
S&F in repair 600 mm long MS chromium plated towel rail of 19mm bore tube with bracket and screw etc complete all as specified and directed.
S&F in repair health faucet with crutch or push handle fancy type , cast copper alloy chromium plated long body screwd down with 1 mtr flexible pipe and screwd for iron pipe 15mm bore complete all as specified and directed. (make pryag, jaquar or equivalant)
S&F in repair 20 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and as directed.
S&F stainless steel hanger 300mm length and 50mm width consisting 4 nos pack set fixed to wall,doors with the help of 75mm screws all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundations of walls and not exc 10 Sqm on plan and n.exc 1.5m in soft soil complete all as specified and as directed.
Returning and filling in soil incl levelling, watering and well rammingin layers n. exc 25cm in fdn trenches complete all as specified and as directed..
Removing surplus excavated soil including disposal of all debris exc 1.5 KMtr and not exc 5 Km outside of MOD land complete all as specifed & as directed.
Demolition of unreinforced cement concrete in ground floors and paving not exc 15cm thickness( below or above ground level) and removing the debris out off MOD land complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) below tiles for levelling of existing surface, mass concrete, etc complete all as specified and directed.
M&L for heavy duty coloured (approved colour) fully vitrified paving tiles of size 300mmx300mmx10-12mm thick, set and jointed in neat cement slurry and pointed in coloured or white cement to match the shade of tiles over and including 15 mm thick screed in CM 1:6 complete all as specified and directed
M&L for 75 mm PCC 1:3:6 type C-2 (40mm graded stone agg) as in plinth protection/hard standing and finished the surface even and smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M&L mild steel TMT bars up to 10mm dia and over cut to length be not to shape as required including cranking, bending spirally for hooping for columns, hooking and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. Note: Laps shall be provided in accordance with IS 456 and will not be measured separately.
M&L mild steel TMT bars 6mm to 8mm dia and over, cut to length bent to shape required including cranking bending, spirally for hooping for columnsand binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. Note: Laps shall be provided in accordance with IS 456 and will not be measured separately.
S&F factory made precast reinforced cement concrete manhole cover(RCC 1:2:4, using 20 mm graded stone aggregate) 100 mm thick (Square/rectangulr/circular) with and including 10 mm dia TMT bars and placed over manholes at site complete all as specified and directed.
M&L for Providing precast cement concrete louvres and jallies type B-0, 1:2:4 using 12.5 mm graded stone aggregate and set in cement mortar 1:6, 35mm thick (measured solid), including all mouldings but excluding frame and applying two coats of white wash complete all as specified and directed.including demolition of concrete and all as directed by Engr in charge
S&F of 4 mm thick Aluminium Composite panel cladding of approved quality and colour as approved by GE,fixing in MS frame at any height and including MS frame of size not exc 0.36 sqm (used in rect angular tubes of size 50.8mmx 25.4mm x 2.9mm thick or square tubes 38mm x38mm x 2.9 mm thick are used in frame) and filling the joints with all weather silicon sealant including all mouldings, cuttings, etc complete all as specified and directed
M&L for stainless steel work as in grills, grating ,railing etc with ends shoulderd and rivetted or forged into spikes framed guard bars, balusters conforming to gde -304 with all jointing accessories like elbow, socket etc and fixed with PCC 1:2:4 in posts and the like including excavation where required complete all as specified and directed
M&L for only grinding and polishing of existing kota stone Flooring and including matching with filling joints with anti bacterial complete all as specified and directed.
M&L for design mix of M-25 (20mm graded store aggregate) for foundations, including rafts, footings, foundation, beams, plinth beams, bases for columns etc, basement for slabs, under reamed piles and mass concrete etc complete all as specified and directed.
M&L for design mix of M-25 (20mm graded store aggregate) for columns, pillars, piers, posts and struts etc complete all as specified and directed.
M&L for design mix of M-25 (20mm graded aggregate) for beams (lintel, roof beam and Gable beam), cantilever, bressummers, lintel ovr 1.50m span etc. complete all as specified and directed.
M&L for design mix of M-25 (20mm graded aggregate) for chajjas etc complete all as specified and directed.
M&L for form work to side of concrete foundation , footings, base of columns, raft and raft beams sides and soffits (if any ) of foundation and plinth beams and similar works vertical or batter, fair finished concerete surface, flat complere all as specified and directed.
M&L for form work to sides of pillars, post struct, pier columns, square, rectangular or polygonal fair finished surfaces of concrete flatcomplete all as specified and directed.
M&L for form work to sides and soofits of floor or roof beams and gable beams, lintels over 1.5 M span, canteliver, shelves incl supports overhang etc fair finished concerete surface flat complete all as specified and directed.
M&L for form work to chajjas etc, throught and similar items incl edges not exc 200 mm thick for fair finished surface of concrete, flat complete all a specified and directed.
S&F 10 to 12mm thick PBC shelf required size area not exc 0.5sqm each fixed with standard beacket fittings as in wall surface complete all as specified and directed .
M&L for drill holes 20mm dia 220mm deep in brick masonry and fillingthe holes in CM 1:3 and inserting 10mm dia bars in it etc. complete all as specified and as directed by Engineer in Charg. (Note: Reinforcement steel shall be measured & paid seprately. )
S&F Brass Elbow (3/4 X 1/2) mm for fixing of CPVC pipe
S&F 20mm Brass Tee for fixing of CPVC pipe
S&F 20mm Male Brass Threaded Adaptor (MTA/MBTA) for fixing of CPVC pipe
SCH A SECTION-II (E/M PORTION)
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and as directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and as directed.
Taking down ceiling fan, exhaust fan including connection cable, dismantling blades and removing fan and blades to MES stores all as specified and as directed by Engineer -in-charge
M&L point wiring for modular switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through concealed Conduit as requirement of site including cadmium plated screws as per ISS, including on and including sunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single pole complete all as specified and as directed.
All as per item No.125 (here in before) but one fan point controlled by one switch 5 Amps one way single pole.
All as per item No. 125 (here in before) but one three pin 5 Amps socket out let on independent board.
All as per item No. 125 (here in before) but one three pin 5 Amps socket out let on same board.
All as per item No. 125 (here in before) but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and as directed.
All as per item No. 125 (here in before) but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on same board with 2.5 Sqmm size of earth conductor complete all as specified and as directed.
All as per item No. 125 (here in before) but point wiring of copper cable multi stranded 4.00 Sqmm size for AC point wiring with 4.0 Sqmm size of earth conductor complete all as specified and as directed.
M&L for point wiring Casing caping complete using 1.5 Sqmm PVC insulated FRLS unsheathed copper conductor, stranded cable upto and incl working voltage 1100volts grade, ISI marked, PVC fittings such as bend,tee,junction boxes elbows etc incl pressed steel terminal sunken boxes of size 1.2mm covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws and unsheathed copper conductor stranded cable earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area for one light point controlled by one switch 5 Amp one way single pole complete all as specified and as directed.
All as per item No. 132 (here-in-before) but one fan point controlled by one switch 5 Amps one way single pole.
All as per item No. 132 (here-in-before) but one three pin 5 Amps socket out let on independent board.
All as per item No. 132 (here-in-before) but one three pin 5 Amps socket out let on same board.
All as per item No. 132 (here-in-before) but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and as directed.
All as per item No. 132 (here-in-before) but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on same board with 2.5 Sqmm size of earth conductor complete all as specified and as directed.
Supply and fix Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete all as specified and as directed.
Supply and fix Switch Piano type, white polycarbonate body, single pole, one way 16 amp, 230 V, including connecting complete all as specified and as directed.
Supply and fix socket white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete all as specified and as directed.
Supply and fix socket white polycarbonate body, 6/16A- 230 V, 2/3 pin combined, including connecting complete all as specified and as directed.
S&F normal type stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete all as specified and as directed.
S&F Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete all as specified and as directed.
S & F modular type Ceiling rose, PVC/ polycarbonate, isolated body type three terminal, 240 volt complete all as specified and as directed.
S&F Modular switch piano , flush button type , single pole , one way 6 Amps complete all as specified and as directed.
S&F Modular switch piano , flush button type , single pole , one way 16 amps complete all as specified and as directed.
S&F Modular socket outlet 3 pin and 2 pin , 6 amps , flush type complete all as specified and as directed.
S&F Modular socket outlet 2-in-1, 6 pin, 6 and 16 amps , flush type complete all as specified and as directed.
S&F modular type one way electronic fan regulator (5 Step up type) 280 Volts suitable for ceiling fan complete all as specified and as directed.
S&F sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 25 Amps , 240 Volts complete all as specified and as directed.
M & L Sub main wiring using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit. Note Two runs of 2.5sqmm copper FRLS cable & one run of 2.5 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit complete all as specified and as directed..
M & L Sub main wiring using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit. Note Two runs of 4sqmm copper FRLS cable & one run of 4.0 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit complete all as specified and as directed..
M & L Sub main wiring using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit. Note Two runs of 6 sqmm copper FRLS cable & one run of 6.0 sqmm copper cable in and including 32mm PVC conduit medium grade will be measured as one unit complete all as specified and as directed.
M & L submain wiring using four run PVC insulated FRLS Copper conductor 10 sqmm with rigid non metalic PVC conduit of size 32 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 10 Sq mm etc.Note four runs of 10 sqmm copper FRLS cable & one run of 10 sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit complete all as specified and as directed.
M & L submain wiring using four run PVC insulated FRLS Copper conductor 16 sqmm with rigid non metalic PVC conduit of size 40 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 16 Sq mm etc.Note four runs of 16 sqmm copper FRLS cable & one run of 16 sqmm copper cable in and including 40 mm PVC conduit medium grade will be measured as one unit complete all as specified and as directed..
S & F in replacement distribution board (DB), double door (CRCA sheet) flushed in wall dust and vermin proof SPN 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and as directed.
S & F in replacement distribution board (DB), double door (CRCA sheet) flushed in wall dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and as directed.
S & F in replacement distribution board (DB), double door (CRCA sheet) flushed in wall dust and vermin proof SPN 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and as directed.
S & F in replacement with taking down distribution board (DB), double door type flushed in wall made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 12 way with 200 Amps rated copper busbar, 415 Volts with in built MCCB 160 Amps, 10 KA, 4 pole, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and as directed.
S & F in repair MCCB 160 Amps, 415 V, , 36 KA, 4 Pole complete all as specified and as directed.
S & F in repair MCB TPN, 415 Volts, 100 Amps, 16 KA complete all as specified and as directed.
S & F in repair MCB TPN, 415 Volts, 40-63 Amps, 10 KA complete all as specified and directed.
S & F in repair MCB SPN, 240 Volts, 32-63 Amps, 10 KA complete all as specified and directed.
S & F in repair MCB SPN, 240 Volts, 6-32 Amps, 10 KA complete all as specified and directed.
S & F in replacement for existing 36/40 Watt tube light fiiting by energy efficient LED light fitting 18/20 Watt,230 Volt of 1200 mm + 50 mm length along with fixture, heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and as directed.
S & F in replacement for existing 18/20 Watt tube light fiiting by energy efficient LED light fitting 9/10 Watt,230 Volt of 600 mm + 60 mm length 6000 K colour temp ,decorative ultra slim linear LED lighting fixture with extruded Al. heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and as directed.
Supply and fix in replacement Energy efficiency recessed mounted 40 W LED luminire suitable for 2 x 2 grid ceiling along with flat diffuser along with constant current electronic driver all as specified and as directed by Engineer-in-Charge
S&F LED Street Light fitting 45 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and as directed.
M & L in repair replacement earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 3 of SSR of part-I (2009) complete all as specified and as directed by Enginer-in-charge.
M & L for painting of ceiling fans/ exhaust fan complete, in situ with syntetic enamel paint as per existing color by spraying including filling cavities with filler, one coat after cleaning all dust, writing of MES No and refixing the same its position after complete servicing all as specified and directed by Engineer -in-charge.
S & F ceiling fan 1200mm, BEE 5 star rating incl suitable size of down rod and flexible wire 2 core of size 23 X .0076' and clamps and nut and bolts complete all specidied and as directed.
S& F exhaust fan 300 mm dia sweep, 900 RPM, 240 Volt heavy duty exhaust fan with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and as directed.
S & F Water heater geyser of capacity 35 Ltr AC Single Phase 240 Volts, 2 KW with all assessories such as copper tank, assembly, element including plumbing works, elect connection ,geyser mounting , incl hot and cold water duty free pvc pipes of size 15mm bore and 60cm long for connection and inlet and outlet pipe line connection , inside the existing wall and making good disturbed surfaces complete all as specified by Engineer in charge. Note :- Old unserveciable Geyser will be deposited to MES store yard.
S&F of modular white cover plate with frame , 3 module complete all as specified and as directed.
S&F of modular white cover plate with frame , 4 module complete all as specified and as directed.
S&F of modular white cover plate with frame , 6 module. complete all as specified and as directed
S&F of modular white cover plate with frame square type , 8 module complete all as specified and as directed.
S&F of modular white cover plate with frame square type , 12 module complete all as specified and as directed.
Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from location to MES store yard, refixing of same AC at location complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers. (b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer. (c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. (d) Providing new suction & discharge copper tubing as recommended by manufacturer with connected clamp and insulation and 4 sqmm 3 core PVC insulated copper cable from indoor and outdoor unit and from main switch of indoor unit with necessory PVC piping all as specified by engineer in charge.
Taking down / Dismantling carefully the air curtain unit and connected wiring, Transportation of complete set from location to MES store yard, refixing of same unit at location complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of unit wall mounting type (to be installed inside the room) complete with, wiring and accessories all as directed. Fixing of unit on wall shall be as per standard recommendation practice of manufacturers. (b) Erection of unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer. (c) All civil work such as making hole in the wall for passing of wire etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. (d) Providing 4 sqmm 3 core PVC insulated copper cable for unit from main switch of unit with necessory PVC piping all as specified by engineer in charge.
Taking down carefully patient call bell, speaker and cameras and camera wiring, wall mounted fans and making good disturbed surfaces of wall floor etc and deposite to mes store yard and refixing the above said items at location during the execution of work complete all as specified and as directed.
M & L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed.
S & F in repair Rigid non-metallic PVC conduit of 25mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
S & F in repair Rigid non-metallic PVC conduit of 32mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
S & F in repair air turbo ventilators of 600mm dai having fins of stainless steel 304 having base plate of 2 mm thick FRP sheet matching the profile of roof sheet having 1962 CFM exhaust cap for 8 to 12 feet height shed incl. Cutting of existing steel sheet complete and insertion new FRP sheet all as specified and directed by engineer in charge. (Note: old air turbo ventilators will be deposited to MES store yards)
Shiv Shankar Nirman Co.
Atish Builders LLP
Ashish Sehgal and Co.
Adhunik Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .