| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹33.1 L+₹66,055.50 (2.04%)Rejected-Finance 227 NEW GANESH VIHAR ADARSH MILL ROAD GHOSIPURA LASHKAR GWALIOR 474012 M P | GWALIOR | MADHYA PRADESH | 474012 | L2 | Rejected-Finance Not a lowest | |
| 3 | L3₹36.9 L+₹4.4 L (13.7%)Rejected-Finance C 187 NIRMAN VIHAR DELHI 92 | L3 | Rejected-Finance Not a lowest | |
| 4 | L4₹37.8 L+₹5.3 L (16.4%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L4 | Rejected-Finance Not a lowest | |
| 5 | L5₹38.3 L+₹5.9 L (18.2%)Rejected-Finance | L5 | Rejected-Finance Not a lowest |
Tender Value
₹39.8 L
EMD Value
₹79,600
Closing Date
8 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA Gwalior
GE AF TA Gwalior 474020
ADDN/ALTERATION TO EJECTION SEAT BAY IN ANNEXE ROOMS OF BTF HANGAR, PROVN OF FLAME PROOF ACs IN EAX-II BLDG OF STN ARMOURY AND PROVN OF SERVO STABILIZER FOR IPSS AT AF STN GWALIOR
2023_MES_612846_1
8900/1507/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN Gwalior
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF TA Gwalior
₹79,600
Yes
10 Oct 2023
10 Aug 2023
11 Sept 2023
10 Aug 2023
8 Sept 2023
26 Aug 2023
Amount
M&L for cutting hole in the existing brick wall forming bed plate of size ISMB 125x6mm thick including supply & fix mono rail trevelling trolley with chain pulley block 1Ton capacity with 3m. Lift suitable for ISMB 125mm complete with all accessories including painting of 1SMB with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make of Chain Pulley Block- Globe oversease pvt ltd/Wolf/Hercules/Safex cranes
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2 TR Non invertor types (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , complete comprising of following :- Make :- Voltas/Carrier/Daikin/Hitechi/Blue star. (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor,. air cooled copper condenser with fan and motor .unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 1% and of capacity 5.0 KVA complete all as specified and directed Make:- V-Guard, Model No- VND-500 or equivallent make :- Blue Bird, AE
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable, 1100 volts grade in and including stove enameled black, rigid steel conduits of size not less than 20 mm dia (Medium grade) concealed in wall as directed with all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLSH, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed NOTE : (i) Old junction boxes retrieved in serviceable conditions shall be re-used in the work. However, additional junction boxes, if any required, for making new point wiring other than the quantity of junction boxes retrieved from taking down of point wiring, shall be measured and paid for separately as ‘’supply only’’ under appropriate item of Schedule `A' but fixing element of any type of junction boxes new or old is deemed to be included in the rates quoted by the contractor for the above item. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
All as per item No 04 here-in-before but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable for 16 A Flame proof Switch and socket complete all as specified and directed
All as per item No 04 here-in-before but point wiring with using 4 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable for 25 A Flame proof Switch and socket complete all as specified and directed
M&L for sub main wiring in repair using Four single core PVC insulated, FRLSH, stranded copper conductor cable of size 4 Sqmm for sub main wiring, along with one run of 4Sqmm PVC insulated, FRLSH, Stranded copper conductor cable for earth continuity conductor in steeel conduit concealed in wall complete all as specified and directed. Note: Four run of single core PVC cable with one run of earth wire and one run of steel conduit together shall be measured as one unit.
Supply & fixing flame proof push button 10 Amps in LM 6 metal enclosures, conforming to existing or equivalent model of other make as specified complete all as specified & directed. Make : Crompton Greaves/Shyaam/Sudhir/Baliga.
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified & directed. Make : Crompton Greaves/Shyaam/Sudhir/Baliga.
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 25 Amps complete all as specified & directed. Make :Crompton Greaves/Shyaam/Sudhir/Baliga.
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 4 pole + earth suitable for 500 volts supply and current rating of 32 Amps complete all as specified & directed. Make : Crompton Greaves/Shyaam/Sudhir/Baliga.
Supply & fixing flameproof distribution board 8 way single pole & neutral in LM-6 metal enclosures with and including 01 No MCBs single pole and neutral 40 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified and directed. Make : Crompton Greaves/Shyaam/Sudhir/Baliga.
Supply & fixing flameproof distribution board 4 way Triple pole & neutral in LM-6 metal enclosures with and including 01 No MCBs tripple pole and neutral 63 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified and directed. Make : Crompton Greaves/Shyaam/Sudhir/Baliga.
Supply and fixing Flameproof ceiling fan 230V AC 91Watt 270RPM 48/56inch dia with LM6, Aluminium enclosure, IP-65 protection powder coated with suitable cable entry and terminals complete all as specified and directed by Engineer-in-charge. Crompton Greaves/Shyaam/Sudhir/Baliga.
Supply and fixing programmable DC power supply 28 Volt 10 Amps, 300 Watt digital dispay AC to DC converter complete all as specifed and directed.
Supply & fix CMIFR Dhanbad or Peso (Nagpur) certified LED flameproof 1x18w or next higher size tube light fitting as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed. Make : Crompton Greaves/Shyaam/Sudhir/Baliga.
Supply, fixing, testing and commissioning of fire alarm control panel non addressable type complying with BS EN 54 double loop panel of capacity from 99 detectors and 99 modules upto 200 detectors and modules complete all as specified and directed by Engr-in-charge. Make- Siemens/System sensor/ Safeway/ Ravel/ Agni
Supply and fixing detectors complying with and type certified to EN-45 non addressable type multisensor detector with heat and smoke combination complete all as specified and directed by Engr-in-charge. Make- Siemens/System sensor/ Safeway/ Ravel/ Agni
Supply and fixng remote response indicators complete all as specifed and directed by Engr-in-charge. Make- Siemens/System sensor/ Safeway/ Ravel/ Agni
Supply and fixing addressable manual call point resetable type complete all as specified and driected by Engr-in-Charge. Make- Siemens/System sensor/ Safeway/ Ravel/ Agni
Supply and fixing addressable sounder complete all as specified and directed by Engr-in-charge. Make- Siemens/System sensor/ Safeway/ Ravel/ Agni
Supply and laying PVC insulated electric control cables (heavy duty) with stranded copper conductors of size 1.5 Sqmm 2 core 1100 volts grade drawn through and including MS pipe not less than 20mm dia complete all as specified and directed by Engr-in-charge. Note-One run of wire and MS pipe will be measured as one unit.
S & F air termination single pointed aluminium rod, single pointed at top and properly threaded at bottom end 300 mm long, 12 mm dia complete all as specified and directed by Engineer-in-charge
Supply and fixing aluminium strip 25x3.15 mm with saddles and fixing screws etc for roof conductors and down conducttors above ground compltete all as specified and directed.
Supply and fixing galvanized iron strip 32x6 mm buried under ground complete all as specified and directed.
M & L for providing test point terminal block made out of Gun metal or phosphorous bronze of size 75 mmx75 mm x25 mm drilled and screwed including 03 nos 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed
M & L for PCC 1:2:4, type B-I using 20 mm graded stone aggregate complete all as specified and directed
S&F GI tubing medium grade 40mm dia for mechanical protection of earth continuity conductor complete all as specified and as directed by Engr-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less' than 1.5 metres below normal ground level, connected to galvanised earth lead 32 x 6.0 mm strip as earthing lead by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion all as specified and as directed. Note: Earth continuity strip 32mmx6mm and GI protection pipe for earth lead wherever buried under ground will be meaured and paid separately against relevant item here after. Necessary excavation, GI funnel, PCC chamber and cover is deemed to be included in the quoted rate.
Demolition of brick work of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of demolished material up to a distance of 2 km complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including disposal of demolished material up to a distance of 1.5 km complete all as specified and directed by Engr-in-Charge.
M&L for RCC 1:2:4 (using 20mm graded stone aggregates) as in Beams( lintel beam , chajja, plinth beam, cantilevers, bressummers,etc complete all as specified and directed
M&L for formwork to sides and soffits of beams, lintels, chajja, shelves including supports, overhangs, etc also splays between floors and beams, etc for flat concrete surfaces fair finished all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
All as per item No 34 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and directed.
M&L for 15mm thick rendering fare face of brickwork/cocrete surfaces and door Jambs, chajja etc in CM 1:4 finished even and smooth without using extra cement all as specified and directed.
M&L for prepration of newly plastered surface and applying two coats of coats distemper oil emulsion with Roller over a coat of primer and a coat of wall putty all as specified and directed.
M&L for prepration of newly plastered surface and applying two coats of coats Exterior emulsion weather coat with Roller over a coat of primer all as specified and directed.
M&L for 3 mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors including filling the cracks and depressions with POP to make the existing floor even and smooth complete all as specified and directed Make: Wonderfloor, Marvel Vinyl, Krishna Vinyls, Premier etc
Taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc and prepared to the plaster complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement backing and wall plaster and dispose off old broken tiles out of premises complete all as specified and directed by Engr-in-Charge.
M&L for glazed ceramic Coloured tiles in vertical surface 350x 250x 7mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surface in cement moratar 1:4 complete all as specified and directed.
Demolition of cement concrete (unreinforced) including floor tiles, ground floors and pavings n. exc 15 cm thick below or above G.L complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) of any description n.exc 1.5 Sqm each complete all as specified & directed
Taking down chowkats with shutters (without taking off shutters from the frames) of any description exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified & directed
S&F Powder coated aluminium frame for door, window, ventilators and partitions with extruded built up standard tubular sections with necessary jointing aluminium cleats using C.P./ stainless steel screws, all as specified and directed by Engr-in-Charge. Note- Aluminium section shall not be more than 2.50mm thickness.
S&F Powder coated aluminium door shutters with extruded built up standard tubular sections using aluminium sec not less than 2 mm thick, (shutter with styles 85mmX 44.45mm, top rails 83.5mmX 44.45mm , intermediate rail 83.5mmx44.45mm, bottom rail 114.3mmx44.5mm) with aluminium beading and rubber neoprene packing for fixing glass/ACP Sheet, all as specified and directed by Engr-in-Charge.
S&F Powder coated aluminium sliding windows shutter with extruded built up standard tubular sections (using aluminium sec not less than 1.00mm thick), with aluminium beading and rubber neoprene packing for fixing glass, brush seal, 02 Nos sliding rollers at bottom, proper locking arrangement to each shutter using C.P./ stainless steel screws, all as specified and directed by Engr-in-Charge.
S&F 5mm thick tinted glass, and glazing in square/rectangular aluminium shutters/frames complete all as specified and directed.
S&F 4mm thick tinted glass, and glazing in squre/rectangular aluminium shutters/frames complete all as specified and directed.
S&F 4mm thick ACP (Aluminium composite pannel) coloured sheet, sandwitch pannel as in alumiium doors/wall claddings with sealent and necessary hidden screws complete all as specified and directed. Make:- REYNOBOND, ALUDECOR, ALSTRONG, ALSTONE, CITY BOND
S&F Stainless steel butt hinges 100 mm size (ISI Marked) with galvanised mild steel hinge pin for aluminium door shutters all as specified and directed.
S&F 200mm long powder coated extruded aluminium alloy handles, fabricated type, complete all as specified and directed .
S&F 150mm long aluminium barrel tower bolts, of extruded section complete all as specified and directed .
S&F 300 mm long aluminium alloy, anodised , sliding door bolt with hasp , staple ( bolt type ) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast - aluminium alloy and fixed complete all as specified & directed
S&F 100 mm Brass Mortice lock 4 lever, vertical type, suitable for auminium doors Make : Godrej Harrison, Link etc
S&F Door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel including necessary cutting to floor and concrete work complete all as specified and directed.
S&F Stainless steel curtain rod 25mm dia and 0.75mm thick fixed to wall fixed with rawal plug and zinc screws complete all as specified and directed.
S&F Stainless steel decorative choice end SS bracket and decorative globe for fixing with curtain rods complete all as specified and directed. Note:- 01 SS bracket and 01 SS Globe measured as one set.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers manually/ machenically and applying two coats distemper oil emulsion with Roller over a coat of primer and two coats of wall putty all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers manually/ machenically including filling the cracks and depression with putty/POP to make the surface even & smooth and applying two coats Exterior emultion weather coat paint with Roller over a coat of primer all as specified and directed.
M&L for prepration of old decorated ceiling surfaces and applying one coat of distemper oil emulsion on ceiling surface including filling the cracks and depression with putty to make the surface even & smooth complte all as specified and directed.
Demolition of stone slabs and paver tiles of any description or thickness in floors, aprons etc incl screed bed complete all as specified and directed
M&L for precast RCC 1:2:4 type B1 (using 20 mm graded stone aggregates) cover slab for man holes, water troughs, mangers, lintels, shelves and similar articles with plain faces incl necessary formwork complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and as directed.
Removing excavated soil to a dist n.exc 50m and depositing where directed at a level n.exc.1.5m ht complete all as specified and directed.
M&L 100mm thick cement concrete 1:4:8 Type D2 ( using 40mm graded stone aggregates) as in sub base complete all as specified and directed.
M&L for 60mm thick machine pressed precast coloured concrete interlocking paver block, Glossy finish confirming to IS 15658-2006, M-35 Grade laid over and including 25mm thick fine sand compacted bed complete all as specified and directed by Engr-in-Charge. Make: ISI Marked as Approved by GE.
M&L for 25 mm thick PCC (1:2:4) type B0 (12.5 mm graded stone agg) as in sub base of flooring for levelling course complete all as specified and directed.
M&L for 10mm thick designer parking tiles of size 300x300mm any colour and pattern, jointed and pointed on neat cement slurry as in floors including 20 mm thick screed bed in CM (1:6) complete all as specified and directed. Make DUROTA, JOHNSON, ORIENT, SOMANY ETC.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor, ramps, kerbs, hold fast, haunching on edges, slightly rounded chamfered angles and throating etc incl necessary form work complete all as specified and directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed Note- Size & Section of all fitting referred to SSR Part-I (2010).
M&L for framed work such as in window grills etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters including MS hinges/ pintle hinges, stops, hand-made sliding bolts, etc. railings, framework of watertanks and similar work conforming to Fe.290.Gde-E-165 Make: ISI Mark As approved by GE
M&L for preparation of new or previously untreated surfaces of steel of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and directed.
Supply, install, testing and commissioning of split type flame proof wall mounted air conditioner of capacity 2.0TR (6000K Col/hr) single phase. Non CFC/HCHC suitable for 230volts +10% 50Hz AC supply complete with cordless remote control unit complete compressing of following duly certified by CIMFR Dhanbad of Peso (Nagpur). Make-Sudhir/Shyaam/Baliga (a) Indoor unit wall mounted with copper tube and aluminium blue fins duly coated with specialist chemical to prevent refrigerent leakage. (b) Outdoor unit comprising of hermetically sealed explosion proof compressor ECO friendly refrigerent, condensor motor, copper condensing coil with copper tubes and aluminium blue fins duly coated with specialist chemical to prevent refrigerent leakage. (c) Refrigerent copper pipe for sunction and discharge line with insulation condensing water drain pipe and protected by suitable size of flexible PVC conduit with control valves and safety accessories including control wing for evaporator and condensing unit with suitable size copper cable. (d) Making good the disturbed surfaces to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B1 (20mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per manufacturer's instruction with necessary grouting, MS holdfast, bolts, washers duly painted and amking good to disturbed surface suitable for installingoutdoor unit of 2TR AC complete. (f) Electrical cable required to connect outdoor unit and indoor unit to voltage stabilizer inclusive in above rate. (g) Flame proof control panel with SPN MCB, indication lamp, Contactor for OL protection and thermostate.
Supply and fix electronic stablizer suitable for 1.5/2TR split air conditioner, 4.0KVA, single phase complete all as directed by Enginner-in-charge.
Supply and Fix sheet metal enclosure three phase pin, single phase 240 volts with plug top for split AC 1.5/2 TR complete all as directed by Enginner-in-charge.
Supply and fix sub main wiring in steel conduit not less than 20mm concealed in wall with 4.0 sqmm, 2 runs and one run for earth continuit conductor complete all as directed.
S&F MCB SPN 10 to 40 Amps complete all as specified and directed and rupturing capacity 10 KA
Supply, installation, testing & commissioning of Servo Voltage stabilizer for automatic operation, three phase naturally oil cooled , Outdoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 Volts per second and of capacity 15 KVA .The Voltage stabilizer shall conform to BID BIS 9815:Part 1 :1994) with following specifications.Make :Volina/Aplab/Blue star/Sinetrac or equivalent approved by Accepting officer. i) Naturally Oil cooled ii) indoor unbalanced type copper wound iii) 1st filling of Transformeroil of approved make iv) Rated frequency 50Hz v) No distortion in wave form vi) Response time not to exceed 20 mille seconds. vii) Sensitivity (+/- )1 % viii) Rate of correction 8 Volt/second for single phase and 13 V/seconds for phase to phase ix) Efficiency more than 95% x) Type of load : three phase , unbalanced type xi) Digital display Voltmeter / Ammeter Protection:- i) Over load/Short Circuit protections ii) High /Low voltage cut off iii) By pass arrangement in case of emergency iv) Single phase cut off and phase reversal cut off. v) Voltage stabilizer shall be of copper bound series transformer and dimmer. Note :- i) Contractor to approve the drawings by the accepting officer before going for procurement . ii) Contractor to conduct all the Manufacturer factory and site tests as mention in para 9 BIS 9815 para 1 reaffirmed 2019 and test report in this regard shall be forwarded . iii) The quoted price shall be inclusive of necessary PCC platform complete all as directed by Eng - in -Charge .
Supply ,installation ,testing & commissioning of Servo Voltage stabilizer for automatic operation, three phase naturally oil cooled , Indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 Volts per second and of capacity 75 KVA .The Voltage stabilizer shall conform to BID BIS 9815:Part 1 :1994) with following specifications.Make :Volina/Aplab or equivalent approved by Accepting officer. i) Naturally Oil cooled ii) indoor unbalanced type copper wound iii) 1st filling of Transformeroil of approved make iv) Rated frequency 50Hz v) No distortion in wave form vi) Response time not to exceed 20 mille seconds. vii) Sensitivity (+/- )1 % viii) Rate of correction 8 Volt/second for single phase and 13 V/seconds for phase to phase ix) Efficiency more than 95% x) Type of load : three phase , unbalanced type xi) Digital display Voltmeter/Ammeter Protection:- i) Over load /Short Circuit protections ii) High /Low voltage cut off iii) By pass arrangement in case of emergency iv) Single phase cut off and phase reversal cut off. v) Voltage stabilizer shall be of copper bound series transformer and dimmer. Note :- i) Contractor to approve the drawings by the accepting officer before going for procurement . ii) Contractor to conduct all the Manufacturer factory and site tests as mention in para 9 BIS 9815 para 1 reaffirmed 2019 and test report in this regard shall be forwarded . iii) The quoted price shall be inclusive of necessary PCC platform complete all as directed by Eng - in -Charge .
Supply and fixing 1100 Volt 10 Sqmm Copper Cable complete all as specified & directed.
Supply and fixing 1100 Volt 25 Sqmm Copper Cable complete all as specified & directed.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. Note- Necessary excavation, GI funnel, PCC chamber and cover are deemed to be included in the quoted rate.
Ditto as per above item, but using galvanised iron strip 32×6mm as earthing lead.
M/s KKPARASHAR
M/S KAPIL CONSTRUCTION CO
M/s Anupam Construction Co.
Lall Electronics
M/S Pramod Kumar Jain
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .