| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC 266 1 S B GORAI ROAD ASANSOL BURDWAN | ASANSOL | BURDWAN | WEST BENGAL | L1 | Accepted-AOC Lowest | |
| 2 | L2₹3.3 L+₹17,975.94 (5.73%)Rejected-Finance 778 N LOWER CHELIDANGA ASANSOL PASCHIM BARDHAMAN | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | L2 | Rejected-Finance L2 | |
| 3 | L3₹3.4 L+₹21,193.80 (6.75%)Rejected-Finance RAJBARI PARA JALPAIGURI | JALPAIGURI | JALPAIGURI | WEST BENGAL | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹6,768
Closing Date
9 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE, MMSD-I, PHED
Government of West Bengal Office of the Assistant Engineer, Midnapore Mechanical Sub-Division-1 P.H. Engineering Directorate Inda P.H.E. Complex, Kharagpur
Cleaning of compound areas and removing of sludge of clear water reserver and repairing of underground pipe line , painting of P H at High lift side at Salua Water Supply Scheme at Medinipur Mechanical Sub Division-I , PHE Dte.
2024_PHED_738409_4
WBPHE/AE/MMSD1/NIeT10OF202425
Open Tender
Electrical Work/ Equipment
Item Wise
15 days
AE, MMSD-I, PHED, Inda, Kharagpur, Paschim Medinipu
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,768
25 Sept 2024
23 Aug 2024
12 Sept 2024
24 Aug 2024
9 Sept 2024
24 Aug 2024
Spreading of Carbolic acid with water solusion using spregun for the protect bite of snake and other dengerous animal during execution of work as per direction.
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead uplo 75 m as directed. (Page no.1)
Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately).
pumping out of water in C.W.R. With the help hiring of 5 HP disel generator pumping set continuously by engaging 1 No. pump operater and 1 No. of helpers for 8 hours
Cleaning rubbish, sludge, weeds scum, liquid earth, mud etc.etc.from road side masonary drain/ hume pipe drain/ culvert etc. by mathor labour after removing concrete Slab/manhole cover etc. without damaging the same and refixing the same properly after cleaning as necessary and removing the sludge etc.etc.by using iron pans, buckets including all labour, tools & plants including removing the spoils in dry condition and disposing the same by truck beyond the road side in conformity with municipal/corporation rules for such disposal including loading into truck and cleaning the road side in all respects as per direction of the Engineer-in-Charge
Dismentalling the old and damaged wooden door asembely after dismentalling all mechanical fixture and supplying fitting fixing of 1 Nos Gl sheet door with MS angle frame fitting fixing in position with renewing brick work (1:4), 20 mm thick cement plaster (1:6), cement concreate (1:2:4) including painting in two coats over a coat of primer all concreate as per direction of EIC. (size of the door 2mtr/1mtr)
Chiping and removing the damaged portion cement concrete roof with engaging skillied masson and helper and removing the rubish from roof to suitable suitable place at a distance of 30 mtr from the site
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety (page No. 26, SL No.10)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface (ii) With 1:4 cement mortar 20 mm thick plaster G.F (pg.no. 189,it no. 1)
Neat cement punning about 1.5mm thick in all.dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.(pg.no. 192, it. No. 150
Earthwork in excavation for detection of possition of damage 100mm and 150mm dia sluice valve (size- 1.2mtr*1.2mtr*1.2mtr) removing sludge from trench dewatering the pipe line water maually and using tulu pump as required. Dismentalling the damage sluice valve and others Cl specials by cutting the nuts and bolts by cutter machine and placing the new sluice valve (Dept. supply) with new one end flange tail piece nuts and bolts, rubber insertion and new gland packing.Whole work should be done as emergency basis through out day and night in 24hours as per direction of EIC i) 200 mm dia sluice valve changing
Construction of different dia sluice valve/ air valve Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm/150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type: manufactuerers not specified] i) 200 mm dia pipe
Transporting of all rubish other raw metarials from the site to outside of the campus by hiring of a tructor and labour gang as per direction of EIC
Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) (VP-1; Pg. 198 It. no.-1]
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) [VP-1; Pg. 200 lt. no.-1 b]
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: a) On timber or plastered surface: With super gloss (hi-gloss) -(ii) Two coats (white in shade) (page No. 200, SL No. 2)
Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) a) One Coat i) Water based interior grade Acrylic Primer. [VP-1: Pg. 195 It. no.-7 (a) (i)]
Acrylic Distemper to Exterior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats [VP-1; Pg. 196 It. no. -10]
Washing cleaning the outside wall by bliching powder water solution by sparying with mechnical device as per direction of EIC
M/s. SOMA ENTERPRISE
MS S G Enterprise
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .