Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.0 LAccepted-AOC | ₹15.0 L Quoted ₹15.2 L | L-1 | Accepted-AOC Lowest and Reasonable |
| 2 | L-2₹15.5 L+₹26,785 (1.76%)Rejected-Finance | ₹15.5 L+₹26,785 (1.76%) | L-2 | Rejected-Finance Other than Lowest |
| 3 | L-3₹16.6 L+₹1.3 L (8.72%)Rejected-AOC | ₹16.6 L+₹1.3 L (8.72%) | L-3 | Rejected-AOC Other than Lowest |
| 4 | L-4₹16.9 L+₹1.7 L (11.3%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹16.9 L+₹1.7 L (11.3%) | L-4 | Rejected-Finance Other than Lowest |
| 5 | L-5₹17.0 L+₹1.7 L (11.4%)Rejected-Finance | ₹17.0 L+₹1.7 L (11.4%) | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹21.8 L
EMD Value
₹43,500
Closing Date
20 Sept 2019, 6:00 pmClosed
Lt Col Dinesh Sharma
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
SPECIAL REPAIR TO UNDERGROUND CABLE AT DHARMUND, SECURITY LIGHTS AT BHALRA, PROVN OF LED SECURITY LIGHTS AT BHALRA, PROVN OF 01 x 200 AMPS SMPS WITH ALLIED INFRA AT RAMBAN AND PROVN OF ELECTRIC METERS AND CAPACITOR BANK AT JANGALWAR, DRABSHALLA, PATN
2019_MES_266775_2
NIT-12 of 19-20
Open Tender
Civil Works
Item Rate
180 days
Bhaderwah
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE (I) 873 EWS
₹43,500
Yes
7 Mar 2020
2 Aug 2019
21 Sept 2019
2 Aug 2019
20 Sept 2019
16 Aug 2019
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for laying of cable, foundation of Pole / Stay, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Taking down unserviceable cable any type / size and removing from site complete all as specified & directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 10 Sqmm 2 core on wall including taking down old cable, complete all as specified and as directed. Makes for Serial Item No '05' to '09' :- Finolex / Universal / RPG Cables / Polycab / Havells / Gloster / KEI
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Taking down defective Security / Street Light Fittings any type from any height, any place of any type, size, make and capacity including brackets and removing from site complete all as specified & directed.
Street Light fitting 45 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and impact resistance of IK07 with 10KV built-in-surge protection device complete all as specified and as directed. Make : Havells 'Endura Pearl Neo' Cat Part No SL45WLED757SASYTOPC or equivalent in Wipro / Philips / Crompton / Syska
Street Light fitting 60 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device all as specified and as directed. Make : Havells 'Endura Pearl Plus' Cat Part No SL60WLED757SASYTOPC or equivalent in Wipro / Philips / Crompton / Syska
Pole mounting bracket made out of medium grade GI pipe of 32mm dia, bent to 600 required shape of length 1.5 mtr with two No's of flat iron clamps made out of 32 x 6mm with 12mm dia bolts, nuts & washers duly painted with aluminium paint over a coat of primer all as specified and as directed.
Restringing / Restretching/ Tightening of old ACSR conductor of any size and make on HT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed.
Electronic Energy meter, single phase, ISI marked, tamper proof with inbuilt intelligence, two wire direct connected meter (whole current) instantaneous parameter (voltage P-n, PF, frequency, current line, KW Demand, LDC Display, Optical port class 1.0s (240 volts 10-60 Amps) complete with connection of suitable size wire including seal and sealing wire and furnishing details of Meter No. initial reading, writing with paint of MES No. all as directed. Make : L&T WM101BC7DL0 / Secure Meters Ltd Udaipur / Actaris / Elster / HPL INDIA LTD
Supply, installation, Commissioning and Testing Automatic Power Factor Correction Panel Board, out door type, factory made, cubical kiosk type, weather, dust and vermin proof, CPRI approved with locking arrangement, made out of CRCA sheet of 3.15mm thick with suitable size of channel for base complete with capacitor banks of capacity 20 KVAR reverse power relay 3 phase with tuned reactor for 63KVA transformer out door type suitable for 1100 Volt 3 phase 50 Hz AC supply floor mounted, connected with suitable size thimbles / lugs, PVC insulated multi-stranded copper wire of suitable size with PVC flexible conduit medium quality as required, comprising of copper bus bar 200Amps capacity fixed on insulators to achieved power factor 0.95 and duly powder coated in Siemens grey colour mounted on PCC platform of PCC 1:2:4 type B-1 on angle iron frame made of 50 x 50 x 6mm thick angle iron duly marked with incoming and outgoing controls, completed all as specified and as directed comprising of the following :-
Notes for Serial Item No 19 : 1. The drawing for APFC Panel shall be got approved by the Engineer-in-Charge. 2. The Pre-dispatch inspection of APFC Panel shall be done by the Rep of the Accepting Officer at factory site. 3. All the existing cables shall be fixed with glands, lugs etc. of the requisite size. Makes for Serial Item No 10 : Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear Make of MCCB & Star Delta Starter : L&T / Legrand / Schneider / Havells Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO Contactor : SECURE / L&T / ABB / SCHENEIDER / SEIMENS / LEGRAND / AE
Supply, install, testing and commissioning of SMPS Power Plant, LCD display, Rack mountable type, Fan Cooled, 48V DC 50 Amps (4 Modules of 50 Amps each connected in parallel for supply 200 Amps at 48V DC, 365 days operating duty, including 1 Hour back up by provision of 12 Volts 150AH Batteries 04 Nos connected in parallel mode alongwith charger and connected control cabling complete with AC/DC Ammeter and AC/DC Voltmeter suitable for operation on Three Phase 415V 50 Hz AC supply as incomer and output supply 48V DC 50 Amps including MCBs of suitable capacity on N/L on input and at least 10 Nos MCBs of 20 Amps each on output complete all as specified and directed.
Make of SMPS : Exicom / Power Pulse Make of Battery : Exide / Amaron / Luminous Note : The quoted rate for SMPS shall be deemed to be inclusive of the cost of batteries, charger, DC copper control cable off, sizes terminations thimbles, MCBs etc. and nothing extra from the department shall be admissible on this account.
Supply and fix Uninterruptible Power Supply (UPS) for 1 hour minimum backup, Three Phase of capacity 10 KVA (08 KW), suitable AC input 300 to 450V and output 415 V ± 1%, double conversion online UPS system, IGBT based fully microprocessor controller, transformer model with battery back up and battery rack suitable for and including accommodating 20 Nos of SMF batteries of 12V 26 AH and inter connecting cables complete all as specified and as directed. Make : Mega Power / Microtek / Numeric 'HP 133'. Make of Battery : Exide / Amaron / Luminous
MCCB 63 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) in steel sheet enclosure complete all as specified and as directed.
MCCB 12 to 63 Amps, breaking capacity 25 KA, Two Pole, 240V, AC (adjustable thermal and magnetic release) in steel sheet enclosure complete all as specified and as directed. Make for Serial Item No 22 & 23 : ABB / Siemens / Legrand / Schneider / L&T
Chemical Earthing complete with copper earth plate electrode 900mm x 60mm x 5mm thick buried directly in ground vertically to a depth not less than 3.5 metre deep below ground level with top edge of earth plate not less than 2.75m below normal ground level connected to copper strip of size 32 x 3mm and 50mm dia bore 7.5 metre long light grade GI protection pipe for earth strip and GI watering pipe 25mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 300mm x 300mm x 300mm etc. and 15 cms alternate layer of NABL lab certified back fill compound for filling of around all sides of earth plate all as shown in Electric Plate No 3 of SSR Part-I with mother soil mixed in 1:3 ratio (one part of back fill compound and three parts of mother soil)
so as to achieve earth resistance below 0.5 Ohm including excavation of Polypit Chamber with Polyplastic pit cover (cost of polypit chamber with polyplastic pit cover shall be deemed to be included in the rate quoted) complete all as specified and directed by Engineer-in-Charge. Notes : (a) Copper Strip beyond test point shall be measured and paid separately. (b) Earthing resistance result shall be less than 0.5 Ohm. If the result comes more than 0.5 Ohm the contractor shall carry out the earthing at separate location/site given by Engineer-in-Charge after taking out of earth electrode without any extra cost to the department. (c) Test point terminal shall be provided by the contractor and no extra cost shall be payable to the contractor on this account.
(d) Any other Fittings / Fixtures if technically required for achieving desired results (if not included above) shall be provided by the contractor without any extra cost to the Govt.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles for loop earthing as required 20 x 3mm copper strip complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Metre below the ground level with top edge of earth plate not less than 1.65 Metre below normal ground level connected to GI strip 25 x 4 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 metre and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
M/S Builders Indias
M/S Vishwa Mittar Pachyala
SINGH CONST CO
shivom builders
darshan kumar gandhi
VARDHMAN INTERNATIONAL
Bidder Name
SWASTIK TRADERS
SINGH CONST CO
VARDHMAN INTERNATIONAL
M/S Builders Indias
darshan kumar gandhi
M/S Vishwa Mittar Pachyala
shivom builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .