Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC HOSHANGABAD M P | HOSHANGABAD | MADHYA PRADESH | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹5.2 L+₹2,732 (0.53%)Rejected-AOC | L2 | Rejected-AOC SECOND LOWEST |
Tender Value
₹5.2 L
EMD Value
₹10,400
Closing Date
15 Feb 2019, 5:00 pmClosed
NARESH SHARMA
12 ANUPAM NAGAR GWALIOR
EXTERNAL ELECTRIFICATION WORK OF 24 Gos QTRS AT GME WORKSHOP 2ND GWALIOR
2019_MPPHC_12849_1
24/2018-19
Open Tender
Electrical Works
Item Rate
60 days
12 ANUPAM NAGAR CITY CENTER GWALIOR
AS PER NIT
4 documents required · 4 mandatory
₹2,000
PROJECT ENGINEER MPPHIDCL GWALIOR DIV. 01
₹10,400
20 Feb 2020
8 Feb 2019
20 Feb 2019
8 Feb 2019
15 Feb 2019
8 Feb 2019
Amount
Supplying and erection of HT/LT over head line single length supports complete with digging and keeping it in truly vertical position i/c digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter dia. of required length around the pole i/c muffing of 0.45meter from ground level as per specification with 20cm.thick base foundation providing and busying 15mm.dia.G.I.pipe from bottom to 1.5meter above ground level on pole, refilling the pit i/c. painting of pole with bitumen paint in bottom and one coat of red oxide and two coat of aluminum paints etc. complete as per specification. The depth of foundation shall be1/6th of the length of pole. 'H' Beam 152x152 mm 37.1 kg/meter weight
(A) 11meter long.
Supplying and errection of stay set completed with stay rod, anchor plate, thimble, stay clamp, turn buckle etc. with stay wire strain insulator nut bolts as per specifications including concreting in required size and excavation in all type of soil! Rocks and also foundations in cement concrete 1:3:6 complete of required size and other necessary materials complete as per specification.
(A) Stay rod 20 mm with 7/4 mm stay wire
Supplying and erection of steel tubular pole swaged type as per IS:2713 1980 Complete with baseplate and top Canopy (with G.I. pipe bracket as required), supports complete with digging and keeping it in truly vertical position i/c digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter dia. of required length around the pole i/c muffing of 0.45meter from ground level as per specification with 20cm.thick base foundation providing and busying 15mm.dia.G.I.pipe from bottom to 1.5meter above ground level on pole, refilling the pit i/c. painting of pole with bitumen paint in bottom and one coat of red oxide and two coat of aluminum paints etc. complete as per specification. The depth of foundation shall be1/6th of the length of pole.
(A) 410 SP-29 - 9 meter length and 125 Kg Weight of Size 5000x139.7x4.85mm, 2000x114.3x4.5 mm 2000x88.9x3.25mm with base plate.
Supplying and fixing of Angle/ channel/flat iron, V cross Arms reinforcement of RSJ jolt/ flat iron fittings for overhead lines and poles such as cross arms/ bracket/ clamps/ stiffness for poles etc. all required steel work including' cutting to size making proper shapes drilling scan welding etc. including nuts & bolts plan & spring wisher and other necessary material including one coat of red oxide and two coat of aluminum paint etc. as required.
Supplying and fixing polymer type 11 KV/33KV disc (strain) insulator of approved make on existing pole or bracket with necessary materials and hardware complete as required.
11 KV Disc (Strain) Insulator
Supplying and fixing polymer type 11 KV/33KV HT disc (strain) insulator of approved make on existing pole or bracket with GI hardware and other necessary materials complete as required.
11 KV Strain insulator(hardware T/C type fitting)
Supplying and drawing ACSR/AAAC conductor of approved make with stringing, making off complete with binding at existing insulator, jointing , jumpering, billing off connecting, making 'D' loops connections etc. complete and clearing of obstacles (if any) as specified and directed.
(B) AAAC Conductor 0.075 Sq. inch ( 80 Sq.mm.) aluminum Equivalent (Raccon)
Providing and fixing ear thing arrangement for H.T./L.T. poles with G.I. wire of 115 turn of 50mm dia. connection with bracket/ cross arm/ pole with 4mm dia. G.I. lead through 20 mm dia. G.!. Protection pipe of length from bottom of pole to 2 meter above ground level, packing of charcoal powder and salt as per specification including excavation of pit in all type of soil / rock etc. complete.
Providing and fixing ear thing arrangement for H.T./L.T. poles with G.I. wire of 115 turn of 50mm dia. connection with bracket/ cross arm/ pole with 4mm dia. G.I. lead through 20 mm dia. G.!. Protection pipe of length from bottom of pole to 2 meter above ground level, packing of charcoal powder and salt as per specification including excavation of pit in all type of soil / rock etc. complete.
Supplying and fixing of danger/ caution Board as per specification with necessary materials complete for H.T. lines and other equipments as required.
Supplying and fixing 12x16 gauge barbed wire antidumping device (900 mm and3.5kg wire on pole) around the existing H.T. pole and sub station poles for safety measures as per IE rules including all staples and all other necessary materials complete as per mpseb specification.
Supplying, installing, connecting, testing and commissioning of approved make distribution transformer 3 Star /5 star rating of accepted standard specification oil filled, core type aluminum /Copper wound out door type 11/ 0.4: KV step down with drain and filler . Value with locking arrangement two ear thing terminals, lifting arrangements and first filling of oil, conventional unit, including installation on existing D.P. structure.
(D) 200 KVA 11 / 0.4 KV (Conventional) 3 Star/ 5 Star Rated.
Providing and fixing outdoor type pole mounting weather, dust and vermin proof L.T. distribution box made of 14/16 gauge, M.S. sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide antirust and corrosion treatment two coats of synthetic enamel paints of approved make and shade, consisting of following fittings. L.T. Distribution box suitable for 63/100/200/315 KVA.transformer (without TPN switches) with required Amp MCCB/Isolator on incoming side and PF HRC units on outgoing side. Or
(D) For 200 KVA Transformer (400 A. Isolator of 9 SP of 160/200 A. & 9 no J type al hook.) ,TPMCCB 315Amp. 35 KA Breaking Capacity Complete as required as per MP SEB latest Specification.
Commissioning of D P structure over existing support with panting in an approved manner consisting of following :- (A) D. C. cross arm with clamp, nuts & bolts (100 x 50 mm only ) - 1 set (B) 11 KV D. O. fuse unit, lightings arrangement and AB swich mounting channel with nuts and bolts (75 x 40 mm channel) of require - 1 set (C) 11 KV Polymer AB swich as required ( set of 3 Nos.) - 1 set (D) Transformer mounting cross arms / channels with clamps nuts and bolts (100 x 50 mm channel ) - 1 set (E) 11KV Polymer Do fuse unit ( set of 3 no.) - 1 set (F) Transformer clamping set (50x50x6 mm angle ) with nuts and bolts etc. complete - 1 set (G) Transformer belting set (50x50x6 mm angle) with nuts and bolts etc. complete - 1 set (H) 11 kv polymer lightning arrestor ( 9 kv gapless type ( 5 kA ) for DTR ) ( set of 3 No.) - 1 set (I) supplying , fixing, testing and connecting of complete earling set of 7 No. as per MPMKVVC.Ltd. circular No DS CO M/EZ/ WS/1516/DT 17-03-2008 and approved dwring for transformer sub - station including all materials GI Strips, GI wires, Charcoal power salt excavation of pits in all types of soils/rocks etc. as required complete .( 1 set of 7 Nos.) -1 set (J) Distribution panel mounting channel and clamp with nuts & bolts etc. (75 x 40 mm channel ) 1 – set (K) Supplying , fixing, testing and Commissioning of DTR Meter LT. 3 phase 4 wire 3X240 volts I 3 A. LTCT operated 3 phase 4 wire 3x63, 5 volts , LB = 5 amps lmax 10 amp trivector meter glass of accuracy 0.5s DLMS complaint category a meter along with GSM ( GPRS compactable ) modems with box i/c all accessories and formalities as per MPMKVVCL as required. or 3P 4w - 5A LTCT class 5s DLMS compliant type c. rs - 232. Port box MRI LTCT 100/5A i/c meter box with TTB etc as required. (L) SF & T and HT tape for covering LT bushing i/c windings and blower hitting complete minimum 30 meter or as required.
D.P. Structure Complete as above (A to L)
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification. (A) Supplying laying testing and commissioning.UnArmoured single core XLPE insulated aluminum conductor cable.
(d) 150 sq mm.
(e) 300 sq mm.
(C) Armoured 2 core XLPE insulated aluminum conductor cable. (confirming IS-7098 Part-I ) 1100 Volt grade,
(a) 10 sq mm.
Supplying and drawing single core PVC insulated cable FR with copper multi strand conductor ISI marked in existing rigid PVC Casing-N-Capping / conduit in surface or concealed as per specification.
2 X 2.5 Sqmm
Supplying fixing testing GI Wire(4.0mm) 8 SWG for gardings.
Supplying fixing testing GI Wire (5.0 mm) 6 SWG for gardings.
Supplying fixing testing and commissioning in propermannr street light timer switch with all required accessories complete with 110 Amps or req.amp switch.
Supplying fixing testing and commissioning in propermannr street light junction Box with all required accessories (D. P. ,S.P. ,Etc.)Complete.
Suppying & installing G.I. Pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc.complete in an approved manner as required to complete excluding cost of excavation/dismentalling & other finshed masonary Item complete. For 'B' Class pipe ISI Marked (IS-1161-68)
Providing and fixing chain link fencing sourriding existing DTR S/S finical (37 feet) of 6’ height with chain ling fencing on MS Angle (50X50X6) mm support 7 nos. 7’ height with following feature. (A) Upper & lower frame of fencing will be of MS angle (25X25X4) mm size. (B) MS strip of (25X5) mm flat shall be used fro cross bracing of fencing (C) Double Gate (2 Nos. 2.5’X5’) of MS angle (50X50X6)mm. bracing of 25X5 mm flat with mesh & locking arrangement.
(Complete as above AtoC) – one job.
Providing and fixing including Testing of LED fixture on street light pole, the fixture should be IP- 65, PF be 0.95 with 85% Power effecency at least of life span of (approxy)working 50,000 Hrs Housing be of Al. Dye cost including connection etc cable reqd. GI pipe braket nute & bolts etc. (Make Bajaj, Crompton, Havells, Syska, Energygreen,Surya, Philips, )
(A)85 watt
ARADHYA ENGINEERS AND CONSULTANTS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .