Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-Finance | L1 | Accepted-Finance Stand First Lowest, hence Accepted. | |
| 2 | L2₹4.0 L+₹47,314 (13.5%)Rejected-Finance | L2 | Rejected-Finance Stand Second Lowest, hence Rejected. | |
| 3 | L3₹4.7 L+₹1.2 L (35.0%)Rejected-Finance KHUKURANI MANDAL | MEDINIPUR EAST | WEST BENGAL | 721130 | L3 | Rejected-Finance Stand Third Lowest, hence rejected. |
| Sl No | Description | Qty | Unit | KAUSHIK ENTERPRISE L2 | KAR ENTERPRISE L3 | SINHA ELECTRIC L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials) ( for 3 days w.e.f 14-08-2026 to 16-08-2026) a) 415 volt 100 Amp. TPNIC main switch with HRC/rewireable fuse | 3 | Each | 263 ₹789 | 292 ₹876 | 217 ₹651 Lowest |
| 1.20 | b) 415 volt 63 Amp. TPNIC main switch with HRC/rewireable fuse | 3 | Each | 190 ₹570 | 210 ₹630 | 157 ₹471 Lowest |
| 2.00 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials) ( for 3 days w.e.f 14-08-2026 to 16-08-2026) a) 240V, 2+12 Way SPNBDB With 6 - 32 amp SPMCB as Outgoing & 40/63 amp DPMCB as Incoming. | 6 | Each | 154 ₹924 | 175 ₹1,050 | 127 ₹762 Lowest |
| 2.10 | b) 415V, Upto 6 Way TPNBDB With 1 No. - 63 amp FPMCB as Incoming & 15No. 6-32 amp SPMCB as Outgoing. | 3 | Each | 232 ₹696 | 263 ₹789 | 192 ₹576 Lowest |
| 3.00 | Providing on hire main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same after function/programme and mending good the damages ( for 3 days w.e.f 14-08-2026 to 16-08-2026) a)4 core 50 sqmm. | 160 | Mtr | 20 ₹3,200 Lowest | 33 ₹5,280 | 25 ₹4,000 |
| 3.20 | b) 4 core 25 sqmm. | 190 | Mtr | 18 ₹3,420 Lowest | 29 ₹5,510 | 22 ₹4,180 |
| 3.30 | c) 4 core 16 sqmm. | 250 | Mtr | 18 ₹4,500 Lowest | 27 ₹6,750 | 20 ₹5,000 |
| 4.00 | Supply & fixing cable gland incl. finishing the ends for the following XLPE/PVC Al. Ar. cables by crimping method incl. S&F of solderless socket (Dowels make) , tapes, anticorrosive paste as to G.S. a) 4 core 50 sqmm. | 10 | Each | 167 ₹1,670 | 189 ₹1,890 | 137 ₹1,370 Lowest |
| 4.10 | 4 core 25 sqmm. | 8 | Each | 88 ₹704 | 100 ₹800 | 72 ₹576 Lowest |
| 4.20 | 4 core 16 sqmm. | 6 | Each | 80 ₹480 | 86 ₹516 | 62 ₹372 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,588
Closing Date
5 Aug 2026, 4:00 pmClosed
Assistant Engineer, P.W.Dte. High Court Elecl. SD
Office of the Assistant Engineer, P.W.Dte. High Court Electrical Sub-Division, 1st Floor, Sesqui-Centenary Building, High Court, Calcutta, KOLKATA-700001
Temporary Electrical Installation and Decorative Work at Main Building, Centenary Building and Sesquicentenary Building of Honorable Calcutta High Court in connection with celebration of Independence Day on 15th August 2026 (for 3 days w.e.f 14-08-2
2026_WBPWD_5017460_1
WBPWD/AE-HCESD/NIQ-27/2026-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
3 days
High Court Electrical Sub-Division PWDte.
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,588
13 Aug 2026
27 Jul 2026
7 Aug 2026
27 Jul 2026
5 Aug 2026
27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials) ( for 3 days w.e.f 14-08-2026 to 16-08-2026) a) 415 volt 100 Amp. TPNIC main switch with HRC/rewireable fuse | 3 | Each | - | - |
| 1.2 | b) 415 volt 63 Amp. TPNIC main switch with HRC/rewireable fuse | 3 | Each | - | - |
| 2 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials) ( for 3 days w.e.f 14-08-2026 to 16-08-2026) a) 240V, 2+12 Way SPNBDB With 6 - 32 amp SPMCB as Outgoing & 40/63 amp DPMCB as Incoming. | 6 | Each | - | - |
| 2.1 | b) 415V, Upto 6 Way TPNBDB With 1 No. - 63 amp FPMCB as Incoming & 15No. 6-32 amp SPMCB as Outgoing. | 3 | Each | - | - |
| 3 | Providing on hire main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same after function/programme and mending good the damages ( for 3 days w.e.f 14-08-2026 to 16-08-2026) a)4 core 50 sqmm. | 160 | Mtr | - | - |
| 3.2 | b) 4 core 25 sqmm. | 190 | Mtr | - | - |
| 3.3 | c) 4 core 16 sqmm. | 250 | Mtr | - | - |
| 4 | Supply & fixing cable gland incl. finishing the ends for the following XLPE/PVC Al. Ar. cables by crimping method incl. S&F of solderless socket (Dowels make) , tapes, anticorrosive paste as to G.S. a) 4 core 50 sqmm. | 10 | Each | - | - |
| 4.1 | 4 core 25 sqmm. | 8 | Each | - | - |
| 4.2 | 4 core 16 sqmm. | 6 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
BOQ_5087671.xls
BOQ • 0.26 MB
2911ii.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .