Executive Engineer Jal Shakti Mechanical Div Sgr
Office of the Ex Engineer JalShakti Mech Div Sgr
Repairs/ replacement to 1000 LPH Capacity RO Water Treatment Plant installed at Government SMHS Hospital Srinagar
2022_PHE_179656_1
PHE/MECH/e-NIT-24 of 07/2022
Open Tender
Miscellaneous Works
Item Rate
7 days
Smhs Hospital
As per NIT
2 documents required · 2 mandatory
₹100
Yes
Executive Engineer Jal Shakti Mechanical Div Sgr
₹2,100
Yes
16 Aug 2022
18 Jul 2022
9 Aug 2022
18 Jul 2022
8 Aug 2022
18 Jul 2022
Amount
RO Membranes
Replacement of old damaged RO membranes with new ones of following specifications:- a) Type--- Spiral Wound TFC b) Operating Pressure--- 10 kg/cm2 c) Flow Rate--- 250 LPH d) Housing Dia ---4.0” e) Housing ---Height 40” Process:- Hyper Filtration by Membranes Result:- Physical Impu. Removal: 100% Biological Impu. Removal: 100% Chemical Impu. Removal: 95-98%
Jumbo Filter /MICRON CARTRIDGE FILTER
Replacement of old damaged of Jumbo filter/MICRON CARTRIDGE FILTER with new one having follwing specifications:- a) Type--- Micron Cartridge/ Bag b) Operating Flow Rate--- 1000 lph c) Operating Pressure---- 2.5 kg/cm2 d) Micron Rating of Cartridge--- 5 micron e) MOC Cartridge ---0Polypropolylene f) Size Cartridge--- 20” Process Micron Filtration by Cartridge below Visilibility. Result Removal of physical impurity from 20 to 1 micron
Activated carbon
Providing and filling of activated carbon in the alreaby available activated carbon vessel and removing of old damaged one. The filter shall be able to remove the total colour , smell, odour, from the water. The dual media should be able to work at 2.5 kg/cm2 gauge pressure. All tools and tackles required shall have to be provided by the firm.
DUAL MEDIA FILTER (DMF)
Providing and filling of DUAL MEDIA FILTER (DMF) in the already DUAL MEDIA FILTER (DMF) vessel and removing of old damaged one. The dual filter shall be having media such as Dual, Sand, Pebbles and Supporting Media as Gravels, Silex. The DMF should be able to Remove Physical impurities from 250 to 50 micron & 50-30 micron , chemical impurities, colour, Odour and biological impurities. The dual media should be able to work at 2.5 kg/cm2 gauge pressure. All tools and tackles required shall have to be provided by the firm.
Raw Water Pump
Proving Fitting and testing of Raw water transfer pump of 01 hp capacity having Operating Flow of 1000 lph.All tools and tackles required shall have to be provided by the firm.
Multi-port Valve /MPV
Providing, and fitting of Multi-port Valve /MPV having size of 25NB of manual type along with following specifications:- MOC---Nary Type---Multiport Valve, Size---25mm Maximum flow rate--- 1500 LPH Working pressure ---4-6 bars Working---Down.
UPVC Pipe/ Fittings
Providing fitting and testing of UPVC Piping of various sizes of heavy grade able to withstand the working pressure along with allied fittings. All tools and tackles required for completion of the job shall have to be arranged by the firm.
Pressure gauges
Providing and fitting of high pressure gauges of 2" size and pressure range upto 3 MPA .All tools and tackles required for completion of the job shall have to be arranged by the firm.
Electrical Pannel
Repairs to electrical pannel by way of replacement of MCB'S Wires, timers, pushbuttons, and other allied items.All tools and tackles required for completion of the job shall have to be arranged by the firm.
GI Pipe/ Fittings
Providing and fitting of 15mm dia.C-class G.I Pipe as per IS 1239 for interconnecting RO with Storage Tank and subsequently to outlet along with allied fittings (TEES, ELBOWS,NIPPLES UNIONS REDUCERS etc).All tools and tackles required for completion of the job shall have to be arranged by the firm
PVC Water Storage tank
Providing and placing on terrace ( at all floor levels) Polyethylene water storage tank ISI: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank,.
Bib Cocks
Providing and fixing of brass bib cock (push type ).
Automatic Water Level Controller
Providing and fitting of Automatic Water Level Controller along with all allied acessorries. The Level Controller shall be able to shutt off/ let in the water from the RO Plant when the water reaches to maximum and minimum desired level respectivly in the water storage tank. All tools and tackles required for completion of the job shall have to be arranged by the firm
Akas ahmad Shah
ALTAF HUSSAIN LONE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .