| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.4 L+₹3.4 L (20.0%)Rejected-Finance | L2 | Rejected-Finance Higher bid value |
| Sl No | Description | Qty | Unit | M/S S. S CHETTRI AND SONS L1 | KARMA TSETEN BHUTIA L2 |
|---|---|---|---|---|---|
| 1.00 | Rough excavation not exc 1.5m deep and getting out in soft/ disintegrated rock for foundation of Retaining Wall complete all as specified and as directed. | 89 | CUBIC METRE | 200 ₹17,800 Lowest | 425 ₹37,825 |
| 2.00 | Excavation over areas not exceeding 1.5 deep in soft/ disintegrated rock for foundation of retaining wall complete all as specified and as directed. | 56 | CUBIC METRE | 200 ₹11,200 Lowest | 425 ₹23,800 |
| 3.00 | M&L for PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete complete all as specified and directed. | 21 | CUBIC METRE | 7,000 ₹1,47,000 Lowest | 8,150 ₹1,71,150 |
| 4.00 | M&L for PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in retaining walls etc complete all as specified and as directed. | 107 | CUBIC METRE | 9,000 ₹9,63,000 Lowest | 10,500 ₹11,23,500 |
| 5.00 | Material & labour for PCC (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. | 2 | CUBIC METRE | 8,000 ₹16,000 Lowest | 9,750 ₹19,500 |
| 6.00 | M&L for RCC M-25 (Design Mix) as in foundation, including rafts, footings, foundation beams, bases for columns etc complete all as specfied and as directed. | 10 | CUBIC METRE | 11,000 ₹1,10,000 Lowest | 12,750 ₹1,27,500 |
| 7.00 | Use and waste of formwork to faces of walls,retaining wall etc; vertical or batter for rough finished surfaces complete all as specified and as directed. | 205 | SQUARE METRE | 500 ₹1,02,500 Lowest | 625 ₹1,28,125 |
| 8.00 | S&F TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping of columns, hooking ends and biniding wireand including mild steelw wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed. | 400 | KG | 149 ₹59,600 Lowest | 185 ₹74,000 |
| 9.00 | All as per item No 8.00 here-in-above but 5 mm and over upto and including 10 mm dia in stirrups spacers and binders complete all as specified and directed. | 170 | KG | 150 ₹25,500 Lowest | 185 ₹31,450 |
| 10.00 | S&F PVC(SWR) pipe 75mm dia single socketed, in any length as in weep holes complete all as specified and directed. | 70 | RUNNING METRE | 425 ₹29,750 Lowest | 440 ₹30,800 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Sept 2025, 6:00 pmClosed
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim
PROVN OF RETAINING WALL NEAR BLDG NO N RES 06 AT NEW MIL STN UNDER GE GANGTOK
2025_MES_729260_1
8362A/A/E8
Open Tender
Miscellaneous Works
Works
182 days
GE Gangtok New Mil Stn Gangtok Sikkim
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹40,000
Yes
14 Oct 2025
3 Sept 2025
1 Oct 2025
4 Sept 2025
29 Sept 2025
10 Sept 2025
Amount
Rough excavation not exc 1.5m deep and getting out in soft/ disintegrated rock for foundation of Retaining Wall complete all as specified and as directed.
Excavation over areas not exceeding 1.5 deep in soft/ disintegrated rock for foundation of retaining wall complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in retaining walls etc complete all as specified and as directed.
Material & labour for PCC (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for RCC M-25 (Design Mix) as in foundation, including rafts, footings, foundation beams, bases for columns etc complete all as specfied and as directed.
Use and waste of formwork to faces of walls,retaining wall etc; vertical or batter for rough finished surfaces complete all as specified and as directed.
S&F TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping of columns, hooking ends and biniding wireand including mild steelw wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed.
All as per item No 8.00 here-in-above but 5 mm and over upto and including 10 mm dia in stirrups spacers and binders complete all as specified and directed.
S&F PVC(SWR) pipe 75mm dia single socketed, in any length as in weep holes complete all as specified and directed.
Labour only for hand packing using broken stone or boulders (any thickness) at back of block masonry retaining wall and raising or lowering to the required level complete all as specified and directed. (using item obtained from item No 1)
S&F of geosynthetic material 75mm dia as in weep holes cover complete all as specified and as directed.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in thick as in soft / loose soil complete all as specified and directed.
Removing excavated material exceeding 1.50 km but not exceeding 5 km and depositing complete all as specified and as directed.
S&F 110mm bore, PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or under floors , fixed on walls with necessary clips complete all as specified and as directed.
Supply and fix 110 mm bore PVC (SWR) bend of any radius for PVC (SWR) pipes, fixed to walls or fixed to steel gutter complete all as directed.
Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition to cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Surfaces excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, complete all as specified and as directed.
M&L Hardcore of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed.
M&L for 100mm thick PCC (1:2:4) type B2 (using 40mm graded curshed stone aggregate) as in hardstanding/ path etc including finish the surface even and fair without using extra cement complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/path etc finishing the surface even & smooth without using extra cement complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channels/drain including forming fair finished to drain channel complete all as specified and as directed.
M&L for raking out joints/pointing to random rubble masonary coursed or uncoursed work in walls on edge in floors, surface channels, roofs etc complete all as specified and as directed.
M&L for Flush pointing CM (1:4) to block in course or ashiar masonry or concrete block walling complete all as speicified and as directed.
KARMA TSETEN BHUTIA (BID ID -3431211)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .