Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹36.3 L+₹28,831.20 (0.80%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 3 | L3₹42.0 L+₹6.0 L (16.6%)Rejected-Finance AT ROAD TINSUKIA HIJUGURI BASH BARI P O HIJUGURI DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 4 | L4₹42.8 L+₹6.9 L (19.1%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L4 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 5 | L5₹43.4 L+₹7.4 L (20.7%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
16 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
SPL REPAIR TO BLDG NO T 2 5A OR COOK HOUSE AND T 4 SM BARRAK OF 73 MTN BDE AT LAIPULI UNDER GE DINJAN
2025_MES_702034_1
84417/E8
Open Tender
Civil Works
Item Rate
180 days
GE DINJAN
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
GE DINJAN
₹77,000
Yes
15 Jul 2025
20 Mar 2025
23 Apr 2025
20 Mar 2025
16 Apr 2025
9 Apr 2025
Amount
Dismantling of Asbestos cement corrugated or Semi-corrugated etc sheet in roof covering all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,ridges, etc., fixed with self tapping screws all as specified and directed.
Except sheeting for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Except sheeting for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,ridges, etc., fixed with self tapping screws all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement or lime mortar including all quoints, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for sub class 'B' Brick built in CM 1:6, straight or curved on plan exc 6m mean radius on plan ,complete all as specified and directed.
M&L for sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4,complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc,complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 6 and finishing even and smooth without using extra cement,complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on other then fair faces of brick work or concrete surfaces and finishing even and smooth without using extra cement WPC @ 3 % by the weight of cement used complete all as specified and directed. (WPC paid in seprate item supply only)
Supply only water proofing compound ,complete all as specified and directed.
Dismantling timber scantling 40 sq.cm and over in section and in any position in unframed work complete all as specified and directed.
M&L 2nd class hardwood, scantling, wrought, timber fixed, complete all as specified and directed.
M&L for preparation of new wooden surface any description not otherwise described and exc 10 cm width or girth applying two coats of synthetic enamal paint over acoat of pink primer including anti termite treatment complete all as specified and diected.
M&L for preparation of old wooden surface any description not otherwise described and exc 10 cm width or girth applying one coats of synthetic enamal paint complete all as specified and diected.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed.
M&L for GI wire netting of 0.90mm dia and 12mm mesh lathing to wood or metal studding, joist, etc in walls, ceilings etc including all laps , cutting and waste fixed with tinned tacks of wire staples etc complete all as specified and directed.
M&L for rendering 15mm thick on one side of lathing in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement all as specified and directed.
M&L for rendering 20mm thick on other side of lathing in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement mixed with WPC all as specified and directed.
M&L preparation of new plastered surfaces of wall and applying three coat of white washing complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall surfaces and applying two coats of Distemper over and incuding a coat of white primer over Imm thick wall care putty complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of old decorative wall surfaces of wall and applying two coats of cement base paint incl complete removal of existing treatment complete all as specified and directed.
M&L for Complete removal of existing treatment and preparation of old decorative wall surfaces and applying two coats of Distemper over a coat of white primer including 1mm thick wallcare putty complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing service abletiles to store and rubbish off the premises all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including plastering 10mm thick on fair faces of brickwork or concrete surfaces in CM 1:4 to receive wall finishes all as specified and directed.
Material & Labour Non Skid ceramic colour tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of mortar for laying floor finishes in cm 1:6 complete all as specified and directed.
M & L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness , including cover fillets complete all as specified and directed.
S&F for 6 mm thick HPSC non asbestos fibre cement Standard Ceiling board (decorative type) with powder coated exposed GI grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Renners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the precut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tee's of 600mm shall be placed perpendicular to the Cross Tee 1200mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6mm dia GI wire from purlins/soffit. 6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density > 1200 Kg/m3) of size 595mm x 595mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8 should be placed in the Grid module to form all as specified and directed.
Demolition of cement concrete in ground floor n exc 15 cm thick (un reinforced) complete all as specified and directed.
Demolition of reinforced cement concrete of any of any description and in any position not otherwise specifically provided for all as specified and directed.
M&L Plain cement concrete 75 mm thick type C1, 1:3:6 (using 40mm graded stone aggregate) for plinth protection finishing even and smooth without using extra cement complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C2, as in surface channels and drains (using 40mm graded aggregate) including necesssary form work for sides all as specified and directed.
M&L Plain cement concrete 75mm thick type C-1, 1:3:6 (using 40mm graded stone aggregate) as in sub-base to receive floor finishes of path etc all as specified and directed.
M&L Chequered cement concrete tile 25mm x 25mm x 22 mm thick with grey cement and pigment set, jointed and pointed in neat cement slurry over and including 15 mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes all as specified and directed.
Use and waste of formwork to edges of concrete flats, breaks in floors, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20 cm wide all as specified and directed.
M&L for reinforcement cement concrete (nominal mix) type B-1, 1:11/2:3 (using 20mm graded aggregate) as in slabs supported on walls / beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding witgh and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips all as specified and directed.
S&F for mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips all as specified and directed.
Taking down wooden Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each but including builders hard ware complete all as specified and directed.
Taking down wooden Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but n exc 4 sq. m including builders hard ware complete all as specified and directed.
S&F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
S&F 35mm thick ,2nd class hardwood plain, framed , panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged),or of veneered particle board medium density,wood particle board with commercial face veneers, complete al as specified and directed
S&F 35mm thick skeliton/gauged shutter open rebated and prepared to recive glass gauged etc (with sash bars) edge of framingg plain,chamfered or rounded, fitted with cut mitred beads for securing glass, etc sizes of members of shutters as specified in SSR part I,Section 8, clause 8.24(a), supplied and fitted to chowkats all as specified and directed.
S&F in repair for stainless steel with cloth 0.36mm nominal dia of wire and average width of aparture 1.40 mm and fixed with stainless steel wire staples in window and door including wooden bids as fixed in repair as old door/window complete all as specified and directed.
S&F for stainless steel with cloth 0.36mm nominal dia of wire and average width of aparture 1.40 mm and fixed with stainless steel wire staples in window and door including wooden bids as fixed in repair as old door/window complete all as specified and directed.
S & F Aluminium Anodised Grill, design pattern as approved by GE fixed with and including standard aluminium frame of flat section of size as approved by GE complete all as per manufacturer instruction.
S&F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
M&L Butt hinges med weight cold rolled mild steel and fixed 100mm size all as specified and directed.
M&L 300mm long Aluminium alloy, anodised, sliding door bolt with hasp staple (Bolt type) and fixing clips of sheet, cast or extruded section or cast aluminium alloy and fixed all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section and fixed 150 mm long all as specified and directed.
S&F Aluminium alloy handles, extruded, fabricated type, anodised 150mm size all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring fixed in floor 140mm size neccesary screws complete.
Dismantling water tanks and removing to store Exe 500 and n.exe 1000 litre all as specified and directed.
S&F Rotational moulded polye thylene water storage tank 1000 Ltrs capacity (Cylindercal vertical with closed top) hoisted and fixed in position all as specified and directed.
S&F 15mm bore ball brass valave high pressure with polythene float & fly nuts complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Taking up or down 15mm dia steel tubing & connection including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm dia steel tubing & connection including cleaning for refixing or removal to store complete all as specified and directed.
S&F of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings 20mm outer diameter on walls/ceiling or layingin floors complete all as specified and directed.
S&F of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings 25mm outer diameter on walls/ceiling or layingin floors complete all as specified and directed.
S&F 600mmx450mm bevelled edges mirror consisting of 5.5mm thick commercial plywood and fixed to plug with chromium plated brass screwed and cup washer all as specified and directed.
S & F stop valve15mm bore cast copper alloy with screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified and directed.
S&F tubular towel rail brass chromium plated, 20mm dia, D type 60 cm long between flanges all as specified and directed.
S&F as in repairs for Bib taps, cast copper alloy with crutch or butterfly handles, screwed doen, screwed for iron pipe or for brass ferule, chromium palted fancy type for 15mm bore pipes, complete all as specified annd direccted.
S&F in repair for PVC (SWR) pipes single socketed of 75mm dia, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repairs 10 ltrs capacity PVC valveless, syphonic action type low level flushing cistern white ISI marked with inlet ball valve, float valve and handle including bracket with 32 mm dia PVC pipe 600mm long including 15mm CP pillar tap complete all as specified and as directed.
S & F in repairs, Vitreous China bowl urinal flat back, of size 465x355x265mm, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S & F in repairs, vitreous China squatting pan, 'Orissa' pattern, size 580mm x 440 mm, white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications all as specified and directed.
S&F in repair for PVC (SWR) pipes single socketed of 110mm dia, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door all as specified and directed.
S & F solid PVC door frames of sizes 50mm x 47mm made out of 5mm but single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with MS Square tube complete all as specified and as directed.
S & F factory made solid panel PVC door shutter 28 to 30mm thick (styles), with 2,4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain coor PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing all as specified and directed.
S&F for PVC (SWR) bends any radius 75mm bore complete all as specified and directed.
S&F for PVC (SWR) bends any radius 110mm bore completeall as specified and directed.
S&F for PVC (SWR) vent cowl 75mm bore complete all as specified and directed.
M&L for Writing letters & figures (Building Nos) (Block, Roman, Italic or Indian) not exc 30cm high complete all as specified and directed.
S&F in repair harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and directed.
M & L for preparation of new steel surfaces of any description exc. 10cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M & L for preparation of old steel surfaces of any description exc. 10cm width or girth & applying one coats of synthetic enamel paint all as specified and directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, including unserviceable fitting such as switches, ceiling roses, pendants, regulators, sockets, etc and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable sub-main wiring any type with rigid steel conduits/PVC Conduits/PVC casing-caping complete all as specified and directed.
M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated FRLSH, multistranded, single core, sheathed, copper conductor cables drawn through PVC casing capping not less than 20mm dia with all fittings and accessories (like Tee, bend etc.) complete for Phase, neutral and earth wire connecting to common earth point including PVC terminal box fixed on walls for housing switches, sockets, regulators, etc all as specified and as directed.
Description as per Ser item No 89 here-in-before but one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed.
Description as per Ser item No 89 here-in-before but for one 3/5 pin Switch socket combination, 5 Amps on Independent board complete all as specified and directed.
Description as per Ser item No 89 here-in-before but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 15 Amps switch socket combination on Independent board complete all as specified and directed.
M & L for Sub main wiring with two runs of 4 sqmm single core cable FRLSH PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC casing capping not less than 20mm dia with all fittings and accessories (like Tee, bend etc.)etc including 4 sqmm (nominal area) single core, FRLSH PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point complete all as specified and as directed by Engineer-in-charge. (Note : (a) PVC Casing-caping, two run cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.)
S&F switch piano, 5 Amp single pole, flush type one way 230 volts complete all as specified and directed.
S & F Bell push, flush type, 5 Amps 230 Volts, complete all as specified and directed.
S & F Socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed.
S&F Switch socket combination, 2 in 1, 5 Amps,flush type, 240 volt complete all as specified & directed.
S&F Switch socket combination, 5A/16A, 5 in 1, 240 volts, flush type complete all as specified & directed.
S & F call bell / Buzzer, Ding Dong AC. 230 volts, single pole all as specified and directed.
S & F lamp holder, insulated body with back plate suitable for batten fittings all as specified and directed.
S & F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and directed.
S&F in repair Stepped type electronic fan regulator flush type 230 volt 5 speed control and connecting up and fix position , complete all as specified & directed.
S & F new 18/20 W surface and wall mounted LED batten inverter type with minimum 04 hrs backup with Extruded aluminium housing having efficiency 125 lm/W and integrated driver all as specified and directed.
S&F 35 watt Supply and fixing LED street light fitting 35 Watt 230 V AC having efficiency 120lm/W and inclding 10 KV SPD outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection connected by 2.5 Sqmm wire complete all as specified & directed.
S&F 10W,LED, Energy saving new generation bulk head luminaire with opal diffuser including lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Havells Cat part no- RUGBYGENXFTS10WLED865SSYMBOPC, or equivalent from list of makes).
S&F in repair Recess 42 watt mounted deep drawn PLANO 2X2 feet CRCA housing with higher power LED Seamless front frame with flat white hight transmission acrylic cover with micro motion sensor technology complete all as per latest standard and all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, TPN, 4 way, 240 Volts , 200 amps suitable for housing MCBs complete all as specified and directed.
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts , 200 amps suitable for housing MCBs complete all as specified and directed.
S & F MCB, TPN, 240 Volts, 63 Amps, 'C' Series, 10KA capacity complete all as specified and directed.
S & F MCB, SPN, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and directed.
S & F MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and directed. (Make: Legrand, Cat No. 408587 to 408595 or equivalent make as per list of manufacturer)
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 350 x 300 x 50 mm deep, including taking down old unserviceable one complete all as specified and directed.
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one/ dismantling complete all as specified and as directed.
Taking down and Refixing of Ceiling fan 1200 mm sweep 230 volt after oiling, greasing, servicing, painting with existing colour including hanging arrangement of fan under different roof after repair made out of heavy duty MS rod/flat hook etc making connection by using 3 core 1 Sqmm flexible wire complete. Note- (1) GI Pipe for hanging of ceiling fan measured under relevent item of sch A all as specified and directed.
Supply and fixing 9W LED Retrofit lamps inverter type with 04 hrs backup complete including taking down old unsv fittings.
S&F street light bracket fabricated out of GI Tubing light grade 32 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron size 40X5mm of suitable length 02 pairs incl nut bolts etc of suitable size, including taking down old corroded one all as specified and directed.
Excavating in trenches n.exc 1.5 mtrs wide and n.exc 1.5 mtr in depth for for laying of cables,foundation etc and getting out in soft/loose soil complete all as specified and directed.
Supply and Laying well burnt bricks, sub class 'B' bricks laid breath wise along length of cable in trenches for cable protection laid for UG cable protection all as specified.
Material and labour for sand cushioning with clean dry sand in trenches for cable protection complete all as specified and as directed.(Note: Thickness after punning down shall be measured for payment)
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated materials n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point in soil, complete all as specified and as directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 4 core including taking out of old unserviceable cable as specified and directed
S & F in repairs, 40mm bore, steel tubes, galvanised, light grade with all fittings and fixtures complete fixed to walls, ceilings, pole using suitable clamp/holder bat complete all as specified and directed.
M/S A D ASSOCIATES (BID ID -3282735)
M/S R D CONSTRUCTION (BID ID -3282210)
R.D.CONSTRUCTION (BID ID -3281992)
M H KHAN (BID ID -3281882)
M/S. UDDUG CONSTRUCTION (BID ID -3281897)
SAHASRA CONSTRUCTION (BID ID -3282577)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .