Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹69.3 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹79.1 L+₹9.8 L (14.1%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹81.9 L+₹12.5 L (18.0%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹89.7 L+₹20.4 L (29.4%)Rejected-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | 4 | Rejected-Finance Not L1 |
Tender Value
₹96 L
EMD Value
₹1.7 L
Closing Date
5 Oct 2021, 6:00 pmClosed
CWE LUCKNOW
229 MG ROAD CWE LUCKNOW
PROVISION OF TRANSFORMER STAND BY DG SET HT/LT CABLES LT PANELS AND ALLIED WORKS FOR PSA OXYGEN GENERATION PLANTS AND OXYGEN AS PIPELINE FOR ACUTE COVID 19 CARE UNDER PARA 35 OF DWP 2020 IN VARIOUS WARDS OF COMD HOSP CC UNDER GE E/M LUCKNOW
2021_MES_473587_1
CWE/LKO/EM/T-43 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EM LUCKNOW
₹1.7 L
Yes
9 Oct 2021
7 Sept 2021
7 Oct 2021
7 Sept 2021
5 Oct 2021
22 Sept 2021
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
M&L for laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick, laid dry over electric cable for protection of cable all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm all as specifed and directed.
S & F 80 mm bore GI Pipes “light grade” with fittings laid in trench for protection of cable complete all as specified and directed.
S & F 50 mm bore GI Pipes “light grade” with fittings laid in trench for protection of cable complete all as specified and directed.
S&F cable route markers made out of PCC block (1:3:6) type C-1 using 20 mm graded stone aggregate size 900x300x100 mm thick (60 cm burried in ground with ` DANGER/11 KV UG cable MES' embossed on route marker including excavation and earth work complete all as specifiedand directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, size 20x15cm complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, size 25x20cm size complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 5652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and directed.
Same as item No 14 above but size 35 sq mm 3½ core
Same as item No 14 above but size 50 sq mm 3½ core
Same as item No 14 above but size 150 sq mm 3½ core
Same as item No 14 above but size 240 sq mm 3½ core
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size UP TO 150 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 240 sqmm,Indoor/Outdoor type complete all as specified and directed.
M&L for Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, Installation, testing and commissioning of 'Silent type' Diesel Generating set having Prime power rating of 200 KVA 415 Volts at 1500 RPM, 0.8 Lagging power factor at 415 V suitable for 50 Hz, 3 Phase system and for 0.8 load factor and consisting of the followings:- Diesel Engine offered shall be as per specification and with following accessories: Diesel Engine 4 stroke Radiator based water cooled,turbo charge, electric start, of suitable BHP at 1500 RPM suitable for above output with alternator and suitable for Lucknow and at site condition conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation.The engine will be fitted complete with all the required accessories Common Bed Plate -Engine and alternator shall be directly coupled or coupled by means of flexoplate/ flexible coupling as per manufacturer standard design and both units shall be mounted on a common bed plate together with all auxiliaries to ensure perfect alignment of engine and alternator with minimum vibrations. The base channel frame shall be suitable for installation on suitable anti-vibration mounting system. contd/...
Engine mounted Instrument Panel fitted with and having digital display forfollowing:Start- Stop switch with key (i) Start- Stop switch with key (ii)Water Temperature indication (iii) Lubrication oil pressure indication(iv)Lubrication oil temperature indication(v) Battery charging indication(vi) RPM Indication(vii) Over speed indication (viii) Low lub. Oil trip indication.(ix) Engine Hours indication FUEL TANK-As per OEM Alternator: Synchronous alternator rated at 320 KVA, 415 Volts at 1500 RPM, 3 Phase,4 wire, 50 Hz, AC supply with 0.8 lagging power factor suitable for Lucknow and at site condition. The alternator shall have SPDP enclosure, brushless,continuous duty, self excited and self- regulated through elctronic AVR conforming to IS: 4722 / BS 2613 suitable for tropical conditions and with class F/H insulation. 12V / 24V DC starting system comprising of starter motors: voltage regulator and arrangements for initial excitation complete with suitable nos of batteries as required as per specifications.Accoustic and weather proof enclosure with arrangements for fresh air intake for cooling of the engine & alternator,extraction, discharging hot air in to the atmosphere as per specifications. cont/...
Unloading, shifting & positioning of DG set.Site testing of DG set (The price shall include required quantity of diesel for site testing) DG PLC inbuilt panel & associated electrical works Supply, Installing, Testing and Commissioning of DG auto change over panel complete with all switchgear, control, protection and metering features as per specification suitable for 320 kVA silent type DG set complete with suitable MCCBs, relays, timers, set of CT's for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from panel to DG set and elsewhere if required, all complete failure to start lockout.Impulse counter with locking and reset facility.ON/OFF/Control circuit switch with indicator.Audio annunciation for 1. High water temperature. 2. Low lubricating oil pressure. 3. Engine Over speed. 4. Engine fails to start 5. Full load / max. load warning. Exhaust System: contd/...
Supply, installation, testing and commissioning of following MS exhaust piping, hospital grade heavy duty class-C complete with all accessories such as bends flanges, flexible connections at a suitable distance etc. and insulated with75 mm thick layer of LRB rock wool having 144 kg/m3 density, cladding with 0.63 mm aluminium sheet all-round the exhaust pipe complete as required at site E. AMF Panel : Auto mains failure panel board suitable for DG set of capacity 200 KVA microprocessor based,outdoor type dust and virmin proof made out of 3.15 mm thick CRCA sheet powder coated with TPN copper bus bar, suitable nos of contactors,microprocessor based relays, etc hooter for protection and comprising of the followings:- (i) CRCA sheet metal panel all as specified (ii) MCCB four pole suitable capacity 36 KA , 415 volts ,400 Amps with thermal and magnetic setting -02 Nos (iii) Power Contactor suitable capacity 4 Pole.02 Nos (iv) COMBINED METER FOR KW,KVA, PF etc -01 Nos (v) Digital Multifunction meter 3 Phase-02 Nos (vi) Current Transformer 200/5A 15 VA class of 1 Accuracy-06 Nos.(vii) PLA relays 12 V DC & 230 V AC-04 Nos (viii) Under and over Voltage Protection Relay-02 Nos (ix) Over Current Relay-02 Nos (x) Over Frequency Relay-02 Nos (xi) Phase Preventer Relay-02 Nos (xii) Digital amperemeter,voltmeter etc-02 Nos (xiii) Battery Charger 20 A, 230V AC/12 VDC-01 Nos
Supply, installation, testing and commissioning of energy efficient four star rating transformer suitable for 200 KVA step down floor mounted outdoor type 11/0.433 KV, 3 phase, 50 Hz AC double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with earthing and having tapping on HV side for constant out put so as to alter/vary secondary voltage by + 7.5% in eaual sep of 2.5% changed by means of manualy operated "Off Load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories as specified in SSR Part-I and IS-1180 Part-I of 2014 . The limit of temperature rise after continuous full load run as specified in IS-1180 Part-I of 2014 and BEE shall be suitably adjusted to suite the maximum ambient temperature of 40-50 degree centigrade as prevalent at Lucknow. The tramsformer shall be complete with as per SI and manufacturer norms & also following fittings and accessories :-(a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level guage. (b) Silicagel breather with connecting pipe, first fill of dehydrating agent. cont/...
(c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservatore air tank (pressure release valve) (d) Air release valve plug. (e ) Explosive vent. (f) 01 No 100 mm dial type thermometer vapour pressure type having ranage 0-120 degree centigrade with max temp indicator and resetting device incl, max reading pointer washer etc. (g) Dehydrating breather with first filling of dehydrating agent. First filling of oil conforming to IS and tested upto 60 KV dielectric strength.
M&L RCC foundation M20 for transformer base platform size 2mx2mx2.5m (1 mtr below ground level) complete all as specified and directed.
Supply and fix drop out fuse unit expulsion type for out door air break gang operated switch, single pole, mounted on and including insulators for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc synthetic bnounded fuse carrying tube complete with line taps and suitable for current carring capacity upto 25 Amps only, all as specified and directed.
S&F lightening arrestor explusion type complete with all fitting, transmission class, discharge capacity 65 kilo amps suitable for 11000 volts all as specified.
Triple pole, mechanically operated,mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 Amps
Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged welded poles complete with C.I. base plate of 6 mm thick of size 300mmx300mm, B 118 finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 Part II, type 410-SP-55 ( 11 meters long) H.T poles including drilling of holes of required size and NOs for fixing of cross arms, painting with one coat of red oxide primer and two coats of black bituminous paint for portion embeded in concrete, painting three black/red/bands at lower portion of pole each of 300mm height at 300mm spacing, painting pole No with black paint at suitable height, complete all as specified and directed and shown on drg ncluding necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 150 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
M& L for fabrication and fixing canopy headed junction box suitable for LT Pole made out 3.15 mm MS sheet of size 30x25x15 cm with cover, 04 nos aluminium bus bar of size 25x3 mm for phase and neutral 01 nos 06 Amps MCB SP mounting channel for control street light cable gland aluminium lug MS FIixing clamp -02 Nos with nut bolt washer painting with two coat of synthetic enamel paint over a coat of red oxide primer on external and internal surface complete all as specified and directed
Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed.
12 mm OD x 0.7 mm thick
15 mm OD x 0.9 mm thick
22 mm OD x 0.9 mm thick
S & F Manifold extendable type along with non-return valves for every cylinder and copper pig tail pipe (W/O) 4+4 emergency manifold oxygen supply with regulator all as specified and directed
S & F Isolation valve with dual fitting bras 12 mm all as specified and directed
S & F Isolation valve with dual fitting bras 15 mm all as specified and directed
S & F Isolation valve with dual fitting bras 22 mm all as specified and directed
S & F Medical gas alarm system 2 line for indicate low line pressure all as specified and directed .
S & F B.P.C Flow meter with bottle 0-15 LMP flow rating with humififier all as specified and directed
S & F Bed head pannel 3' length with 03 outlets and socket points all as specified and directed.
Installation testing and commissiong of copmlete plant and test of leakage of pipe line with hight pressure smoke testing including all installed parts as per Specification. Note During testing any pipe,part damage broken will be replaced by vender without any extra cost to department.
M/S S.B. Singh and Sons
Ashirwad Contractor and Supplier
BHARAT ELECTRICAL TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .