Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.0 LAccepted-AOC | L-1 | Accepted-AOC L-1 |
Tender Value
Refer Docs
EMD Value
₹69,705
Closing Date
27 Jul 2020, 5:00 pmClosed
EE WSSD NO 3 JALANDHAR
EE WSSD NO 3 JALANDHAR
AUGMENTATION OF WATER SUPPLY SCHEME RAIPUR GUJJRAN MH FC FROM HANDPUMP BLOCK MEHATPUR DISTT JALANDHAR UNDER PRWSSIP 1Aiii JJM PROJECT
2020_WB_48530_2
RAIPUR GUJJRAN 1A(III) 2020 DWSS-W-DIV79-8113-1
Open Tender
Civil Works
Item Rate
180 days
IN VILLAGE RAIPUR GUJJRAN
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
TIA
₹69,705
9 Sept 2020
15 Jul 2020
28 Jul 2020
15 Jul 2020
27 Jul 2020
15 Jul 2020
Amount
TUBEWELL Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as Telescopic/hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.
(a) Boring with 200mm id Housing pipe upto 150m depth BGL
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
(a) 150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness.
Supplying, fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked, duly welded with suitable grade S.S. welding electrode to lower the strainer into tubewell bore.
(a) 150mm steel strainer (slot size 0.15mm) 5.00 mm thickness
Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI marked duly welded with suitable grade ss welding electrode to lower the strainer into tubewell bore complete in all respect.
(a) 150mm Internal diameter
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.
(a) 150mm internal diameter
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.
(a) 150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
(a) 150mm internal diameter
Development and Stabilizing of the tubwell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
(a) Capacity of Air compressor 300 cfm at 250 PSI
Development and Stabilizing of the tubwell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
OHSR Constructing one No. of 15 KL (15000 litres) Capacity with sill level not less than14.50m height upto FSL 17.00 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing C.I. D/F expansion joints or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow C.I. double flanged pressure pipes horizontally as per IS 7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including overflow haudi complete in all respects including Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects including Construction of plinth protection around OHSR with 40mm thick C.C 1:2:4 on top over 100mm thick C.C 1:8:16 masonry toe wall & inside earth filling with lead 5 kms. complete in all respect
DISTRIBUTION Providing, Laying, Fixing and Jointing of P.V.C. Pipes as per ISI-4985 (ISI mark with the prior approval of Engineer in Charge along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including specials and excavations complete as per specifications. specifications for Manually Excavation including speicals (6kgf/ cm2) Pressure
(a) PVC pipe 63mm o/d PVC 6 kg/cm2
Providing, Laying, Fixing and Jointing of P.V.C. Pipes as per ISI-4985 (ISI mark with the prior approval of Engineer in Charge along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including specials and excavations complete as per specifications. for more than 3 mtr. Street width. (Mechanically ) (6kgf/ cm2) Pressure
(a) PVC pipe 63mm o/d PVC 6 kg/cm2
(b) PVC pipe 90mm o/d PVC 6 kg/cm2
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position.
(a) PVC pipe 63mm o/d
(b) PVC pipe 90mm o/d
Hand Boring Horizontally for crossing of pipe under Road or any other obstacle by using Auger/Bocki method including excavation, stringing and jointing of pipe upto 160mm complete.
Dismantling of metalled road and back filling with excavated earth, fully compacted. (Contractor shall quote rate only for the The restoration of the metalled road to its original condition will be done by the concerned department i.e. PWD B&R / PMB / Panchyati Raj)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) class PN-1 as per ISI
(a) 80mm I/d sluice valves flanged
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department of Size 0.6m x 0.6m (Including Carriage)
HOUSE SERVICE CONNECTIONS Water Connection with Water Meter Providing proposed water connection with multijet water meter to house hold upto wall with providing laying jointing testing G.I. Pipeline 15mm i/d = 2.5 mtr (B-Class) (Above G.L.) Prov and fixing 15mm i/d MDPE pipe with specials = 2.00 mtr (Below GL) including cost of specials such as Tees, Bends., Sockets, Elbow, Peet Valve, Union, Nipple and Hook etc. cutting and threading testing in trenches in the ground and ISI 15mm i/d GM Ferrule as per IS:2692 and 3 inches i/d Clamp with C.I. Bib Cock, 15mm i/d as per IS:210 with Stainless Steel Spindle of approved make
CHLORINATION & DISINFECTION Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
PUMPING MAIN Providing, Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete including specials and excavations as per specifications (Mechanically Excavation)
(a) 90 mm o/d pipe of 10kgf./sqcm
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nuts, Bolts & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) class PN-1 as per ISI
(a) 80mm i/d sluice valves flanged
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (Including Carriage)
(a) Size 0.6m. X 0.6m.
PUMPING MACHINERY Providing & installing, testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 121 LPM against a head of 67 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc. including G.I. column Pipe of IS 1239-2004 medium class size 50mm and Length 46 mtr. (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 100 Mtr Length and 2.50mm2 size as per IS694-1990 reaffirmed 2000. Including cost of Electronic over currant relay complete in all respects
(a) 121 LPM, 67 MTR HEAD (Motor with Pump)
(b) Panel Board
(c) Cable (Size/Cost) 2.50mm2
(d) Column Pipe (G.I. B-Class)( Size/Length) (50mm i/d)
D.I. FITTING Providing & Fixing 80mm dia delivery main (Tubwell to duck foot bend) including cost of D.I pipes & Specials, C.I S.V Non Retrun Valve, Double Air Valve, G.I pipes & Specials, G.M Peet Valve etc. complete in all respect as per standard drawing
PUMP CHAMBER Construction of Pump Chamber Below OHSR TANK size 2.20x2.20m Without gravel pit but including electric wiring, complete in all respects. (Including Carriage)
SOLAR PANEL Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc. in water works site including Bi-directional meter and inverter of suitable capaity as per guide lines issued by PEDA complete in all respects.
DEVELOPMENT OF HEADWORKS Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard drawing
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects including carriage. as per standard drawing
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard drawing
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects including carriage as per standard drawing
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr complete in all respect including carriage. as per standard drawing
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works complete in all respects including carriage. as per standard drawing
Providing & fixing MS Sign Board as per standard size of DWSS as per Engineer in Charge
OPERATION & MAINTENANCE COST WITHOUT ELECTRICITY CHARGES Operation and Maintenance water supply system for 3 Months including operating of machinery , repair of leakages, supplying of full time Pump Operator cum- Chowkidar, supply of Sodium Hypo Chlorite solution for disinfection for 3 months after completion.
ENVIROMENT Making lawns including ploughing & dragging with 'Sohaga' breaking of clods, removal of earth rubbish dressing & Supplying doob grass roots and planting at 15 cm. apart including Supplying and spreading of farm yard manure@ 0.18 cum per 100 sqm & loosening.
Supplying and planting permanent trees including digging of earth pits size 75cmx75cmx75 cm deep, refilling the excavated earth with manure supplied @ 0.113 cum each and watering Supplying through tractor tanker. (Trees like Neem, Ashoka, Dake, Arjun etc.)
Planting ground cover plants including digging and refilling of beds with excavated soil and FYM, Fertilizer and insecticides, planting of saplings at 30cm distance from plant to plant and row to row, providing and fixing brick tiles edging.
Planting flower beds including digging and refilling of beds with excavated soil and FYM, fertilizer and insecticides, planting of sapling at 30cm distance from plant to plant and row to row.
Provision for one way stand post with Khura complete in all respects
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .